{"product_id":"allen-bradley-1756-l81e-nsext-cpu-module","title":"Allen-Bradley 1756-L81E-NSEXT CPU Module","description":"\u003cdiv style=\"max-width:100%;margin:0 auto;font-family:Arial,Helvetica,sans-serif;color:#1a1a1a;font-size:15px;line-height:1.6;overflow-wrap:anywhere;\"\u003e\n\u003ch2 style=\"font-size:22px;line-height:1.3;margin:0 0 12px;color:#1a1a1a;\" class=\"desc-model-title\"\u003eAllen-Bradley 1756-L81E-NSEXT ControlLogix 5580 NSE XT Controller, 3MB User Memory, Conformal Coated, No RTC Backup\u003c\/h2\u003e\n\u003cp style=\"margin:0 0 12px;line-height:1.6;\"\u003eThe \u003cstrong\u003eAllen-Bradley 1756-L81E-NSEXT\u003c\/strong\u003e is ControlLogix 5580 NSE XT extreme environment controller, NSE = No Stored Energy, no RTC battery backup. It features 3 MB user memory, conformal coated PCB, wide operating temperature range -25°C ~ +70°C, integrated 1Gigabit EtherNet\/IP port, local USB 2.0 programming port, 4-character alpha\/numeric front LED display. Supports up to 100 EtherNet\/IP devices, total 128,000 I\/O points and maximum 256 motion axes. Lifecycle: Active. Technical data sourced from official Rockwell Automation ControlLogix 5580 datasheet. Supplied by SHLY-PLC, an independent industrial automation distributor; each unit undergoes visual inspection and functional testing before shipment. Contact our team for compatibility verification.\u003c\/p\u003e\n\u003ch2 style=\"font-size:18px;line-height:1.3;margin:22px 0 10px;padding:0 0 6px;border-bottom:2px solid #cc0000;color:#1a1a1a;\"\u003eFeatures\u003c\/h2\u003e\n\u003cul style=\"margin:6px 0 14px 20px;padding:0;\"\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e\n\u003cstrong\u003eCatalog Number:\u003c\/strong\u003e 1756-L81E-NSEXT\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e\n\u003cstrong\u003eProduct Family:\u003c\/strong\u003e ControlLogix 5580 NSE XT Controller, Logix5000 Platform\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e\n\u003cstrong\u003eUser Memory:\u003c\/strong\u003e 3 MB\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e\n\u003cstrong\u003eNSE Feature:\u003c\/strong\u003e No Stored Energy, no RTC battery backup, no residual stored energy after power off\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e\n\u003cstrong\u003eConformal Coating:\u003c\/strong\u003e Yes, protected against dust, humidity \u0026amp; corrosive gas\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -25°C to +70°C (XT wide temperature range)\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e\n\u003cstrong\u003eEmbedded Communication:\u003c\/strong\u003e 1 x Gigabit EtherNet\/IP port (10\/100\/1000Mbps)\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e\n\u003cstrong\u003eLocal Port:\u003c\/strong\u003e USB 2.0 full-speed programming port Type B\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e\n\u003cstrong\u003eFront Display:\u003c\/strong\u003e 4-character alpha\/numeric LED display\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e\n\u003cstrong\u003eMax EtherNet\/IP Devices:\u003c\/strong\u003e 100\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e\n\u003cstrong\u003eMaximum Total I\/O Points:\u003c\/strong\u003e 128,000\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e\n\u003cstrong\u003eMotion Axis Support:\u003c\/strong\u003e Up to 256 motion axes\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e\n\u003cstrong\u003eNon-Volatile Storage:\u003c\/strong\u003e Compatible with SD card (1784-SD1 \/ 1784-SD2)\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e\n\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e 6.2 W (21.2 BTU\/h)\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e\n\u003cstrong\u003eLifecycle:\u003c\/strong\u003e Active\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e\n\u003cstrong\u003eTypical Use:\u003c\/strong\u003e Harsh industrial environments requiring no residual stored energy after power loss, wide temperature fluctuations, dust and moisture\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size:18px;line-height:1.3;margin:22px 0 10px;padding:0 0 6px;border-bottom:2px solid #cc0000;color:#1a1a1a;\"\u003eSpecifications\u003c\/h2\u003e\n\u003cp style=\"font-size:13px;color:#666666;margin:0 0 4px;\"\u003eOfficial Rockwell Automation ControlLogix 5580 XT NSE Data\u003c\/p\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;table-layout:fixed;margin:6px 0 18px;font-size:14px;\"\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#cc0000;color:#ffffff;padding:7px 11px;text-align:left;vertical-align:top;word-break:break-word;font-weight:700;\"\u003eTechnical Specifications\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eCatalog Number\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;vertical-align:top;word-break:break-word;\"\u003e1756-L81E-NSEXT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;vertical-align:top;word-break:break-word;\"\u003eControlLogix 5580 NSE XT Extreme Environment Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eUser Memory\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003e3 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eNSE Function\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eNo Stored Energy, no RTC battery backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003e-25°C ~ +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eIntegrated Network\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003e1 x Gigabit EtherNet\/IP (10\/100\/1000 Mbps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eLocal Programming Port\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eUSB 2.0 Type B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eMax Total I\/O\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003e128,000 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eMax Motion Axes\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003e256 axes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003e6.2 W (21.2 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eFront Display\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003e4-character alpha\/numeric LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eCompatible SD Card\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003e1784-SD1, 1784-SD2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"background:#eef1f4;color:#1a1a1a;padding:6px 11px;font-weight:700;text-align:left;vertical-align:top;word-break:break-word;border-bottom:1px solid #e6e8eb;\"\u003eAgency Certifications\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width:42%;padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003eCertifications\u003c\/td\u003e\n\u003ctd style=\"padding:7px 11px;border-bottom:1px solid #e6e8eb;background:#fafbfc;color:#333333;font-weight:600;text-align:left;vertical-align:top;word-break:break-word;\"\u003ecULus, CE, C-Tick\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cdiv style=\"font-size:13px;line-height:1.5;color:#990000;background:#fef0f0;border-left:3px solid #cc0000;padding:9px 12px;margin:12px 0;\"\u003e\n\u003cstrong\u003eModel note:\u003c\/strong\u003e NSE = No Stored Energy, no RTC battery backup, no residual stored energy after power removal. XT = conformal coated PCB with -25~70°C wide temperature range. Not safety controller, not PlantPAx process controller. Programming software: Studio5000 Logix Designer V33+.\u003c\/div\u003e\n\u003ch3 style=\"font-size:15px;line-height:1.4;margin:14px 0 3px;color:#1a1a1a;\"\u003eCompatibility \u0026amp; Cross-References\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 12px;line-height:1.6;\"\u003e1756-L81E-NSEXT works with standard ControlLogix 1756 chassis, 1756 power supplies, standard 1756 I\/O modules. Supports EtherNet\/IP motion control. This listing is provided by an independent industrial automation distributor; brand names and part numbers are used for product identification only.\u003c\/p\u003e\n\u003ch2 style=\"font-size:18px;line-height:1.3;margin:22px 0 10px;padding:0 0 6px;border-bottom:2px solid #cc0000;color:#1a1a1a;\"\u003eApplications\u003c\/h2\u003e\n\u003cul style=\"margin:6px 0 14px 20px;padding:0;\"\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003eHazardous \/ high safety requirement cabinets where no residual stored energy is required after power off\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003eWide temperature range industrial automation with dust, humidity and mild corrosive atmosphere\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003eEtherNet\/IP multi-axis motion control up to 256 axes\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003eSystem retrofits requiring XT harsh environment and NSE no stored energy feature\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"font-size:18px;line-height:1.3;margin:22px 0 10px;padding:0 0 6px;border-bottom:2px solid #cc0000;color:#1a1a1a;\"\u003eWarranty\u003c\/h2\u003e\n\u003cul style=\"margin:6px 0 14px 20px;padding:0;\"\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e\n\u003cstrong\u003eAvailability:\u003c\/strong\u003e Active model, in stock available; contact us for real-time stock status.\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e\n\u003cstrong\u003eInspection \u0026amp; testing:\u003c\/strong\u003e each unit is visually inspected and functionally checked before packing.\u003c\/li\u003e\n\u003cli style=\"margin:0 0 6px;line-height:1.55;\"\u003e\n\u003cstrong\u003eDelivery:\u003c\/strong\u003e orders are processed within 2-4 business days after payment confirmation; standard worldwide delivery is about 5-8 business days, express shipping available, orders over $500 ship free.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12-month seller warranty provided by SHLY-PLC. See our \u003ca href=\"\/pages\/return-policy\"\u003eReturn Policy\u003c\/a\u003e for coverage and claims.\u003c\/p\u003e\n\u003cdiv style=\"font-size:13px;line-height:1.5;color:#555555;background:#f7f7f8;border-left:3px solid #cc0000;padding:9px 12px 0 12px;margin:12px 0;\"\u003eIndependent supplier: Allen-Bradley part 1756-L81E-NSEXT is supplied by SHLY-PLC, an independent industrial automation distributor. Brand names and part numbers are used for product identification and remain the property of their respective owners; this listing is not affiliated with, sponsored or endorsed by the manufacturer.\u003c\/div\u003e\n\u003ch2 style=\"font-size:18px;line-height:1.3;margin:22px 0 10px;padding:0 0 6px;border-bottom:2px solid #cc0000;color:#1a1a1a;\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3 style=\"font-size:15px;line-height:1.4;margin:14px 0 3px;color:#1a1a1a;\"\u003eQ: What is Allen-Bradley 1756-L81E-NSEXT?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 12px;line-height:1.6;\"\u003eA: ControlLogix 5580 NSE XT PLC,3MB memory,conformal coating,-25~70°C wide temp,No Stored Energy (no RTC battery),max 100 EtherNet\/IP devices,active product.\u003c\/p\u003e\n\u003ch3 style=\"font-size:15px;line-height:1.4;margin:14px 0 3px;color:#1a1a1a;\"\u003eQ: What does NSE stand for?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 12px;line-height:1.6;\"\u003eA: NSE = No Stored Energy. No RTC backup battery, no residual stored energy after power removal, meets special safety requirements.\u003c\/p\u003e\n\u003ch3 style=\"font-size:15px;line-height:1.4;margin:14px 0 3px;color:#1a1a1a;\"\u003eQ: What software programs this controller?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 12px;line-height:1.6;\"\u003eA: Studio5000 Logix Designer version 33.04 or newer.\u003c\/p\u003e\n\u003ch3 style=\"font-size:15px;line-height:1.4;margin:14px 0 3px;color:#1a1a1a;\"\u003eQ: Is 1756-L81E-NSEXT safety controller?\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 12px;line-height:1.6;\"\u003eA: No. It is standard general-purpose NSE XT controller, not GuardLogix safety controller and not PlantPAx process controller.\u003c\/p\u003e\n\n\u003cp style=\"font-size:12px;color:#888888;text-align:center;margin:18px 0 4px;\"\u003e1756-L81E-NSEXT · Technical reference data · Independently supplied by SHLY-PLC\u003c\/p\u003e\n\u003c\/div\u003e\n","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46350163607805,"sku":"1756-L81E-NSEXT","price":4998.88,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/1756-L81E-NSEXT.jpg?v=1792125994","url":"https:\/\/shly-plc.com\/products\/allen-bradley-1756-l81e-nsext-cpu-module","provider":"SHLY-PLC","version":"1.0","type":"link"}