{"product_id":"allen-bradley-1756-cfm","title":"Allen-Bradley 1756-CFM | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eControlLogix Config Flowmeter Module\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e2 Channel\/2 Out Configurable Flowmeter (20Pin)\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConducted RF immunity:\u003c\/strong\u003e 10V rms with 1 kHz sine wave 80% AM from 150 kHz...80 MHz on shielded signal ports\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCount range, max:\u003c\/strong\u003e 2, 147, 483, 647\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent draw:\u003c\/strong\u003e 300mA @ 5.1V, 16mA @ 24V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital inputs configurable:\u003c\/strong\u003e true\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital outputs configurable:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEFT\/B immunity:\u003c\/strong\u003e ¡À4kV @ 5kHz on unshielded output and power ports, ¡À4kV @ 5kHz on shielded input ports\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmissions:\u003c\/strong\u003e IEC 61000-6-4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure type:\u003c\/strong\u003e None (open-style)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD immunity:\u003c\/strong\u003e 6 kV contact discharges, 8 kV air discharges\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFiltering (inputs F0 \u0026amp; F1):\u003c\/strong\u003e Firmware selectable: high-speed 100 kHz or low-pass filter for frequencies \u0026lt;70 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlowmeter input impedance:\u003c\/strong\u003e 5 k? ¡À30% resistive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlowmeter input voltage:\u003c\/strong\u003e ¡À30V, selectable input thresholds of 50mV @ 1.3V and 4V: ¡À30V peak unterminated open circuit voltage, magnetic pickup, TTL compatible, input voltage \u0026gt;1.3V DC is Logic 1 and -0.7...1.3V DC is Logic 0, 12...24V DC powered preA output, 4V DC threshold\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e Resolution: 0.0005 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGate input on-state current, min:\u003c\/strong\u003e 4 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGate input on-state current, nom:\u003c\/strong\u003e 15 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGate input voltage range:\u003c\/strong\u003e 5V ops: 4.5...5.5V DC @ 12\/24V ops: 10...26.4V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh resolution, max:\u003c\/strong\u003e 100 khz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput frequency, max:\u003c\/strong\u003e 100 kHz @ flowm inputs (overrange occurs at 100 kHz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput sampling period:\u003c\/strong\u003e User selectable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInputs:\u003c\/strong\u003e Two flowm (F) inputs used for all modes, Two gate inputs used in Totalizer mode for prover\/store count, 4 (2 per channel)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation voltage:\u003c\/strong\u003e 250V (continuous), reinforced insulation type, I\/O-to-backplane, 250V (continuous), basic insulation type, I\/O group-to-group\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical filter debouncing (Z0 \u0026amp; Z1 Inputs):\u003c\/strong\u003e Software selectable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule keying:\u003c\/strong\u003e Electronic, software configurable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNonoperating temperature:\u003c\/strong\u003e -40 ¡ãC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNorth American temperature code:\u003c\/strong\u003e T4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-state leakage current, max:\u003c\/strong\u003e \u0026lt;300 ¦ÌA @ 31.2V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-state voltage drop, max:\u003c\/strong\u003e 0.6 ? x current\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e 0 to 60 ¡ãC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput control:\u003c\/strong\u003e Any number of outputs is assignable to any of two flowm channels each output can have 2 ¡°turn-on¡± and ¡°turn-off¡± preset values\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput current per point:\u003c\/strong\u003e 1 @ 10...31.2V DC @ 20mA @ 4.5...5.5V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput reverse polarity protection:\u003c\/strong\u003e Yes (if wired incorrectly, module outputs can be permanently disabled.)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutputs:\u003c\/strong\u003e 2 current sourcing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput short circuit protection:\u003c\/strong\u003e Electronic (no indication of fault. remove overload and toggle output on\/off to restore.)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput switching time:\u003c\/strong\u003e \u0026lt;50 ¦Ìs turn on, \u0026lt;300 ¦Ìs turn off, Outputs triggered by Total, all other ¡°turn-on¡± and ¡°turn-off¡± times \u0026lt;1 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput type:\u003c\/strong\u003e IEC 1 A 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput voltage range, nom:\u003c\/strong\u003e 5V ops: 4.5...5.5V DC @ 3...20mA load per point, 12\/24V ops: 10...31.2V DC @ 40mA...1 A load per point\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput voltage source:\u003c\/strong\u003e Customer supplied\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload current:\u003c\/strong\u003e Electronic (\u0026lt;4 A)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower dissipation, max:\u003c\/strong\u003e 6 W @ 60 ¡ãC (140 ¡ãF)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRadiated RF immunity:\u003c\/strong\u003e 10 V\/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10 V\/m with 200 Hz 50% Pulse 100% AM @ 900 MHz, 10 V\/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz, 3 V\/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative humidity:\u003c\/strong\u003e 5...95% noncondensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReverse polarity protection:\u003c\/strong\u003e Outputs only\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRTB keying:\u003c\/strong\u003e User-defined mechanical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock:\u003c\/strong\u003e Operating: 30 G, Non operating: 50 G\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-circuit protection, outputs available:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot width:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable for safety functions:\u003c\/strong\u003e false\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurge current:\u003c\/strong\u003e 2 A @ 50 ms, repeatable every 2s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurge transient immunity:\u003c\/strong\u003e ¡À1 kV line-line (DM) and ¡À2 kV line-earth (CM) on unshielded output and power ports, ¡À2 kV line-earth (CM) on shielded input ports\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurrounding air temperature, max:\u003c\/strong\u003e 60 ¡ãC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal dissipation:\u003c\/strong\u003e 20.4 btu\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal backplane power:\u003c\/strong\u003e 1.7 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotalizer fill and prover:\u003c\/strong\u003e true\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType of electric connection:\u003c\/strong\u003e Screw connection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration:\u003c\/strong\u003e 2 G @ 10...500 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage type of supply voltage:\u003c\/strong\u003e DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire category:\u003c\/strong\u003e 2 on signal ports, 1 on power ports\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":47841210269949,"sku":"1756-CFM","price":1115.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/1756-CFM.jpg?v=1785381402","url":"https:\/\/shly-plc.com\/products\/allen-bradley-1756-cfm","provider":"Lianyou PLC","version":"1.0","type":"link"}