{"product_id":"abb-xt2n-160-tma-80-800-4p-f-f-1sda067038r1-molded-case-circuit-breaker","title":"ABB XT2N 160 TMA 80-800 4p F F 1SDA067038R1 Molded Case Circuit Breaker","description":"\u003cstyle\u003e.shly-pdp{--ink:#1c2024;--muted:#5b6570;--line:#dfe3e8;--bg:#fff;--soft:#f6f7f9;--accent:#C8102E;max-width:1000px;margin:0 auto;padding:4px 0 32px;color:var(--ink);font-family:-apple-system,\"Segoe UI\",Roboto,Helvetica,Arial,sans-serif;line-height:1.62;font-size:15.5px;-webkit-text-size-adjust:100%;}\n.shly-pdp *{box-sizing:border-box;}\n.shly-pdp h3{font-size:17px;font-weight:700;margin:34px 0 12px;padding:0 0 8px;border-bottom:1px solid var(--line);letter-spacing:.2px;}\n.shly-pdp p{margin:0 0 12px;}\n.shly-pdp .shly-eyebrow{font-size:11.5px;letter-spacing:1.6px;text-transform:uppercase;color:var(--accent);font-weight:700;margin:0 0 8px;}\n.shly-pdp .shly-lead{font-size:16.5px;line-height:1.68;color:#2b3138;margin:0 0 4px;}\n.shly-pdp .shly-lead b{font-weight:700;}\n.shly-pdp .shly-facts{list-style:none;margin:14px 0 0;padding:0;display:grid;grid-template-columns:repeat(4,1fr);gap:1px;background:var(--line);border:1px solid var(--line);border-radius:6px;overflow:hidden;}\n.shly-pdp .shly-facts li{background:var(--soft);padding:12px 14px;font-size:13.5px;line-height:1.45;}\n.shly-pdp .shly-facts span{display:block;font-size:11px;text-transform:uppercase;letter-spacing:.9px;color:var(--muted);margin-bottom:4px;}\n.shly-pdp .shly-facts strong{font-weight:700;font-size:14.5px;}\n.shly-pdp table{width:100%;border-collapse:collapse;margin:6px 0 10px;font-size:14.5px;table-layout:fixed;}\n.shly-pdp th,.shly-pdp td{text-align:left;vertical-align:top;padding:9px 12px;border-bottom:1px solid var(--line);word-break:break-word;}\n.shly-pdp th{width:38%;font-weight:600;color:#333a41;background:#fafbfc;}\n.shly-pdp tr.shly-group td{background:#eef1f4;font-size:11.5px;letter-spacing:1.3px;text-transform:uppercase;font-weight:700;color:#48525c;padding:7px 12px;}\n.shly-pdp .shly-note{font-size:13.5px;color:var(--muted);border-left:3px solid var(--line);padding:2px 0 2px 12px;margin:10px 0 0;}\n.shly-pdp ul.shly-list{margin:8px 0 0;padding:0 0 0 20px;}\n.shly-pdp ul.shly-list li{margin:0 0 8px;}\n.shly-pdp .shly-q{border-top:1px solid var(--line);padding:14px 0 2px;}\n.shly-pdp .shly-q:first-of-type{border-top:none;}\n.shly-pdp .shly-q p{margin:0 0 6px;}\n.shly-pdp .shly-q .shly-qq{font-weight:700;color:#1c2024;}\n.shly-pdp .shly-q .shly-qq em{font-style:normal;color:var(--accent);margin-right:6px;}\n@media (max-width:720px){\n.shly-pdp{font-size:15px;}\n.shly-pdp .shly-facts{grid-template-columns:repeat(2,1fr);}\n.shly-pdp th,.shly-pdp td{padding:8px 10px;font-size:14px;}\n.shly-pdp th{width:42%;}\n}\u003c\/style\u003e\n\u003cdiv class=\"shly-pdp\"\u003e\n\u003cp class=\"shly-eyebrow\"\u003eABB · SACE Tmax XT2N · Moulded Case Circuit Breaker\u003c\/p\u003e\n\u003cp class=\"shly-lead\"\u003e\u003cb\u003e1SDA067038R1\u003c\/b\u003e is an ABB \u003cb\u003eSACE Tmax XT2N 160\u003c\/b\u003e moulded case circuit breaker (MCCB), fixed four-pole version with front terminals and a thermomagnetic TMA R 80 release — rated 80 A and 36 kA ultimate breaking capacity at 415 V AC.\u003c\/p\u003e\n\u003cul class=\"shly-facts\"\u003e\n\u003cli\u003e\n\u003cspan\u003eCatalog number\u003c\/span\u003e\u003cstrong\u003e1SDA067038R1\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eFrame\u003c\/span\u003e\u003cstrong\u003eXT2N 160\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eRated current In\u003c\/span\u003e\u003cstrong\u003e80 A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eBreaking capacity Icu\u003c\/span\u003e\u003cstrong\u003e36 kA @ 415 V AC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eElectrical\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated current In\u003c\/th\u003e\n\u003ctd\u003e80 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated operational voltage Ue\u003c\/th\u003e\n\u003ctd\u003e690 V AC \/ 500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui\u003c\/th\u003e\n\u003ctd\u003e1000 V (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated impulse withstand Uimp\u003c\/th\u003e\n\u003ctd\u003e8 kV (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreaking capacity Icu (415 V AC)\u003c\/th\u003e\n\u003ctd\u003e36 kA (Ics = 100% Icu; 65 kA @ 240 V AC, 10 kA @ 690 V AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of poles\u003c\/th\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelease\u003c\/th\u003e\n\u003ctd\u003eTMA R 80 thermomagnetic — thermal Ir adjustable 0.7...1×In (56...80 A); magnetic I3 adjustable 5...10×In (400...800 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eMechanical\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVersion\u003c\/th\u003e\n\u003ctd\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminals\u003c\/th\u003e\n\u003ctd\u003eFront terminals (bolt connection, M6, 6 N·m; busbar 32.5...100 mm²)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (H × W × D)\u003c\/th\u003e\n\u003ctd\u003e130 × 120 × 82.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApprox. weight\u003c\/th\u003e\n\u003ctd\u003e1.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMechanical durability\u003c\/th\u003e\n\u003ctd\u003e25,000 operations (240 cycles\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eEnvironment \u0026amp; compliance\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-25...+70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure rating\u003c\/th\u003e\n\u003ctd\u003eIP20 (higher ratings with terminals\/ accessories per catalogue)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertifications\u003c\/th\u003e\n\u003ctd\u003eCE, LR, GL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp class=\"shly-note\"\u003eValues follow the official ABB SACE Tmax XT catalogue data for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.\u003c\/p\u003e\n\u003ch3\u003eModel comparison in the same family\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"4\"\u003eABB SACE Tmax XT2 160-frame variants\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCatalog number\u003c\/th\u003e\n\u003cth\u003eRelease\u003c\/th\u003e\n\u003cth\u003eBreaking capacity Icu @415 V\u003c\/th\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1SDA067038R1 — XT2N 160 TMA 80-800 4p F F (this page)\u003c\/td\u003e\n\u003ctd\u003eTMA thermomagnetic\u003c\/td\u003e\n\u003ctd\u003e36 kA\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXT2N 160 Ekip LSI (1SDA067071R1)\u003c\/td\u003e\n\u003ctd\u003eEkip LSI electronic\u003c\/td\u003e\n\u003ctd\u003e36 kA\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXT2L 160 TMA (1SDA067648R1)\u003c\/td\u003e\n\u003ctd\u003eTMA thermomagnetic\u003c\/td\u003e\n\u003ctd\u003e120 kA\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXT2V 160 TMA (1SDA067715R1)\u003c\/td\u003e\n\u003ctd\u003eTMA thermomagnetic\u003c\/td\u003e\n\u003ctd\u003e150 kA\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eWhere it sits in the power distribution system\u003c\/h3\u003e\n\u003cp\u003eThe XT2N 160 is the standard 36 kA member of the ABB SACE Tmax XT2 160-frame family. This catalog number pairs the 4-pole fixed body (fully rated neutral) with the TMA R 80 thermomagnetic release: both the thermal (overload) and magnetic (instantaneous) thresholds are adjustable, and the 4P configuration switches all three phases plus the neutral. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.\u003c\/p\u003e\n\u003ch3\u003eBefore you specify\u003c\/h3\u003e\n\u003cul class=\"shly-list\"\u003e\n\u003cli\u003e\n\u003cb\u003eBreaking capacity.\u003c\/b\u003e Confirm the prospective fault current at the installation point does not exceed 36 kA at 415 V AC; coordination with upstream\/downstream devices depends on it.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eRelease.\u003c\/b\u003e TMA R 80 gives an adjustable thermal setting of 56...80 A and an adjustable magnetic pick-up of 400...800 A; verify the settings match the downstream cable protection study.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePoles.\u003c\/b\u003e This is the 4P fully-rated-neutral version — match it to a 3-phase + neutral system. A 3P unit must not be substituted on a 4-wire board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMounting and connection.\u003c\/b\u003e Fixed body with front terminals — confirm panel depth and terminal clearances before ordering.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhat is 1SDA067038R1?\u003c\/p\u003e\n\u003cp\u003eIt is the ABB catalog number for the SACE Tmax XT2N 160 TMA 80-800 fixed 4-pole (fully rated neutral) moulded case circuit breaker with front terminals — an 80 A MCCB with 36 kA ultimate breaking capacity at 415 V AC.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhich release does this breaker use?\u003c\/p\u003e\n\u003cp\u003eThe TMA R 80 thermomagnetic release: thermal (overload) protection adjustable 0.7...1×In (56...80 A) and magnetic (instantaneous) pick-up adjustable 5...10×In (400...800 A).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhy is this the 4-pole version?\u003c\/p\u003e\n\u003cp\u003eThe 4P body switches all three phases plus the neutral of a 3-phase + neutral system — required where the neutral must be broken with the phases (e.g. TT earthing or mixed loads). A 3P unit must not be substituted on a 4-wire board.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eHow is this unit mounted and connected?\u003c\/p\u003e\n\u003cp\u003eFixed mounting with front bolt terminals (M6, 6 N·m) accepting busbars 32.5...100 mm². Dimensions are 130 × 120 × 82.5 mm (H × W × D) and net weight approx. 1.45 kg.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":71124878950653,"sku":"1SDA067038R1","price":349.33,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/1SDA067038R1.webp?v=1793774861","url":"https:\/\/shly-plc.com\/products\/abb-xt2n-160-tma-80-800-4p-f-f-1sda067038r1-molded-case-circuit-breaker","provider":"SHLY-PLC","version":"1.0","type":"link"}