{"product_id":"abb-xt2n-160-mf-8-5-im-120-3p-f-f-1sda067047r1-molded-case-circuit-breaker","title":"ABB XT2N 160 MF 8.5 Im=120 3p F F 1SDA067047R1 Molded Case Circuit Breaker","description":"\u003cstyle\u003e.shly-pdp{--ink:#1c2024;--muted:#5b6570;--line:#dfe3e8;--bg:#fff;--soft:#f6f7f9;--accent:#C8102E;max-width:1000px;margin:0 auto;padding:4px 0 32px;color:var(--ink);font-family:-apple-system,\"Segoe UI\",Roboto,Helvetica,Arial,sans-serif;line-height:1.62;font-size:15.5px;-webkit-text-size-adjust:100%;}\n.shly-pdp *{box-sizing:border-box;}\n.shly-pdp h3{font-size:17px;font-weight:700;margin:34px 0 12px;padding:0 0 8px;border-bottom:1px solid var(--line);letter-spacing:.2px;}\n.shly-pdp p{margin:0 0 12px;}\n.shly-pdp .shly-eyebrow{font-size:11.5px;letter-spacing:1.6px;text-transform:uppercase;color:var(--accent);font-weight:700;margin:0 0 8px;}\n.shly-pdp .shly-lead{font-size:16.5px;line-height:1.68;color:#2b3138;margin:0 0 4px;}\n.shly-pdp .shly-lead b{font-weight:700;}\n.shly-pdp .shly-facts{list-style:none;margin:14px 0 0;padding:0;display:grid;grid-template-columns:repeat(4,1fr);gap:1px;background:var(--line);border:1px solid var(--line);border-radius:6px;overflow:hidden;}\n.shly-pdp .shly-facts li{background:var(--soft);padding:12px 14px;font-size:13.5px;line-height:1.45;}\n.shly-pdp .shly-facts span{display:block;font-size:11px;text-transform:uppercase;letter-spacing:.9px;color:var(--muted);margin-bottom:4px;}\n.shly-pdp .shly-facts strong{font-weight:700;font-size:14.5px;}\n.shly-pdp table{width:100%;border-collapse:collapse;margin:6px 0 10px;font-size:14.5px;table-layout:fixed;}\n.shly-pdp th,.shly-pdp td{text-align:left;vertical-align:top;padding:9px 12px;border-bottom:1px solid var(--line);word-break:break-word;}\n.shly-pdp th{width:38%;font-weight:600;color:#333a41;background:#fafbfc;}\n.shly-pdp tr.shly-group td{background:#eef1f4;font-size:11.5px;letter-spacing:1.3px;text-transform:uppercase;font-weight:700;color:#48525c;padding:7px 12px;}\n.shly-pdp .shly-note{font-size:13.5px;color:var(--muted);border-left:3px solid var(--line);padding:2px 0 2px 12px;margin:10px 0 0;}\n.shly-pdp ul.shly-list{margin:8px 0 0;padding:0 0 0 20px;}\n.shly-pdp ul.shly-list li{margin:0 0 8px;}\n.shly-pdp .shly-q{border-top:1px solid var(--line);padding:14px 0 2px;}\n.shly-pdp .shly-q:first-of-type{border-top:none;}\n.shly-pdp .shly-q p{margin:0 0 6px;}\n.shly-pdp .shly-q .shly-qq{font-weight:700;color:#1c2024;}\n.shly-pdp .shly-q .shly-qq em{font-style:normal;color:var(--accent);margin-right:6px;}\n@media (max-width:720px){\n.shly-pdp{font-size:15px;}\n.shly-pdp .shly-facts{grid-template-columns:repeat(2,1fr);}\n.shly-pdp th,.shly-pdp td{padding:8px 10px;font-size:14px;}\n.shly-pdp th{width:42%;}\n}\u003c\/style\u003e\n\u003cdiv class=\"shly-pdp\"\u003e\n\u003cp class=\"shly-eyebrow\"\u003eABB · SACE Tmax XT2N · Moulded Case Circuit Breaker\u003c\/p\u003e\n\u003cp class=\"shly-lead\"\u003e\u003cb\u003e1SDA067047R1\u003c\/b\u003e is an ABB \u003cb\u003eSACE Tmax XT2N 160\u003c\/b\u003e moulded case circuit breaker (MCCB), fixed three-pole version with front terminals and a magnetic-only MF 8.5 release (fixed instantaneous protection) — rated 8.5 A and 36 kA ultimate breaking capacity at 415 V AC.\u003c\/p\u003e\n\u003cul class=\"shly-facts\"\u003e\n\u003cli\u003e\n\u003cspan\u003eCatalog number\u003c\/span\u003e\u003cstrong\u003e1SDA067047R1\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eFrame\u003c\/span\u003e\u003cstrong\u003eXT2N 160\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eRated current In\u003c\/span\u003e\u003cstrong\u003e8.5 A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eBreaking capacity Icu\u003c\/span\u003e\u003cstrong\u003e36 kA @ 415 V AC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eElectrical\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated current In\u003c\/th\u003e\n\u003ctd\u003e8.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated operational voltage Ue\u003c\/th\u003e\n\u003ctd\u003e690 V AC \/ 500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated insulation voltage Ui\u003c\/th\u003e\n\u003ctd\u003e1000 V (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated impulse withstand Uimp\u003c\/th\u003e\n\u003ctd\u003e8 kV (IEC 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBreaking capacity Icu (415 V AC)\u003c\/th\u003e\n\u003ctd\u003e36 kA (Ics = 100% Icu; 65 kA @ 240 V AC, 10 kA @ 690 V AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of poles\u003c\/th\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelease\u003c\/th\u003e\n\u003ctd\u003eMF 8.5 magnetic-only — instantaneous I3 fixed at 120 A; no thermal (overload) function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eMechanical\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVersion\u003c\/th\u003e\n\u003ctd\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminals\u003c\/th\u003e\n\u003ctd\u003eFront terminals (bolt connection, M6, 6 N·m; busbar 32.5...100 mm²)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (H × W × D)\u003c\/th\u003e\n\u003ctd\u003e130 × 90 × 82.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApprox. weight\u003c\/th\u003e\n\u003ctd\u003e1.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMechanical durability\u003c\/th\u003e\n\u003ctd\u003e25,000 operations (240 cycles\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eEnvironment \u0026amp; compliance\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-25...+70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure rating\u003c\/th\u003e\n\u003ctd\u003eIP20 (higher ratings with terminals\/ accessories per catalogue)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertifications\u003c\/th\u003e\n\u003ctd\u003eCE, LR, GL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp class=\"shly-note\"\u003eValues follow the official ABB SACE Tmax XT catalogue data for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.\u003c\/p\u003e\n\u003ch3\u003eModel comparison in the same family\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"4\"\u003eABB SACE Tmax XT2 160-frame variants\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCatalog number\u003c\/th\u003e\n\u003cth\u003eRelease\u003c\/th\u003e\n\u003cth\u003eBreaking capacity Icu @415 V\u003c\/th\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1SDA067047R1 — XT2N 160 MF 8.5 Im=120 3p F F (this page)\u003c\/td\u003e\n\u003ctd\u003eMF magnetic-only (fixed)\u003c\/td\u003e\n\u003ctd\u003e36 kA\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXT2N 160 Ekip LSI (1SDA067071R1)\u003c\/td\u003e\n\u003ctd\u003eEkip LSI electronic\u003c\/td\u003e\n\u003ctd\u003e36 kA\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXT2L 160 TMA (1SDA067648R1)\u003c\/td\u003e\n\u003ctd\u003eTMA thermomagnetic\u003c\/td\u003e\n\u003ctd\u003e120 kA\u003c\/td\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXT2V 160 TMA (1SDA067715R1)\u003c\/td\u003e\n\u003ctd\u003eTMA thermomagnetic\u003c\/td\u003e\n\u003ctd\u003e150 kA\u003c\/td\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eWhere it sits in the power distribution system\u003c\/h3\u003e\n\u003cp\u003eThe XT2N 160 is the standard 36 kA member of the ABB SACE Tmax XT2 160-frame family. This catalog number pairs the 3-pole fixed body with the MF 8.5 magnetic-only release: it provides fixed instantaneous short-circuit protection at 120 A but no thermal overload function, so it is used where overload protection is provided by another device — typically small motor feeders or circuits with a separate overload relay. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.\u003c\/p\u003e\n\u003ch3\u003eBefore you specify\u003c\/h3\u003e\n\u003cul class=\"shly-list\"\u003e\n\u003cli\u003e\n\u003cb\u003eBreaking capacity.\u003c\/b\u003e Confirm the prospective fault current at the installation point does not exceed 36 kA at 415 V AC; coordination with upstream\/downstream devices depends on it.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eRelease.\u003c\/b\u003e MF is magnetic-only with a fixed 120 A pick-up — verify the fault current and the separate overload protection before substituting an adjustable MA unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePoles.\u003c\/b\u003e This is the 3P version — match it to a three-phase system without neutral switching.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMounting and connection.\u003c\/b\u003e Fixed body with front terminals — confirm panel depth and terminal clearances before ordering.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhat is 1SDA067047R1?\u003c\/p\u003e\n\u003cp\u003eIt is the ABB catalog number for the SACE Tmax XT2N 160 MF 8.5 Im=120 fixed 3-pole moulded case circuit breaker with front terminals — an 8.5 A-frame MCCB with fixed magnetic-only release (I3 = 120 A) and 36 kA ultimate breaking capacity at 415 V AC.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhich release does this breaker use?\u003c\/p\u003e\n\u003cp\u003eThe MF 8.5 magnetic-only release: instantaneous short-circuit pick-up fixed at 120 A. It has no thermal overload function — pair it with a separate overload relay where overload protection is needed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eHow does XT2N differ from XT2S\/XT2H\/XT2L in the same frame?\u003c\/p\u003e\n\u003cp\u003eSame 160-frame footprint, different breaking capacity: XT2N = 36 kA, XT2S = 50 kA, XT2H = 70 kA, XT2L = 120 kA, XT2V = 150 kA at 415 V AC.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eHow is this unit mounted and connected?\u003c\/p\u003e\n\u003cp\u003eFixed mounting with front bolt terminals (M6, 6 N·m) accepting busbars 32.5...100 mm². Dimensions are 130 × 90 × 82.5 mm (H × W × D) and net weight approx. 1.1 kg.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":71124878655741,"sku":"1SDA067047R1","price":257.68,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/9IBA248849_master_9fc11609-d7d5-4f13-867e-95870ec05c9e.png?v=1789032026","url":"https:\/\/shly-plc.com\/products\/abb-xt2n-160-mf-8-5-im-120-3p-f-f-1sda067047r1-molded-case-circuit-breaker","provider":"SHLY-PLC","version":"1.0","type":"link"}