{"product_id":"abb-ua75-30-00ra-220-230v-50hz-230-240v-60hz-1sbl411024r8000-installation-contactor","title":"ABB UA75-30-00RA 220-230V 50Hz \/ 230-240V 60Hz 1SBL411024R8000 Installation Contactor","description":"\u003cp\u003e\u003cstrong\u003eABB product — UA75-30-00RA 220-230V 50Hz \/ 230-240V 60Hz\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- \u003c!-- ABB-PIS-OFFICIAL-DATA-BLOCK --\u003e --\u0026gt;\n\u003ch2\u003eProduct identification\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel: UA75-30-00RA 220-230V 50Hz \/ 230-240V 60Hz\u003c\/li\u003e\n\u003cli\u003eGlobal material number: 1SBL411024R8000\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSource: ABB Product Information System (PIS) - official ABB product data\u003c\/p\u003e\n\u003cp\u003eEvidence URL: \u003ca href=\"https:\/\/www.abb.com\/global\/en\/products\/1sbl411024r8000\"\u003ehttps:\/\/www.abb.com\/global\/en\/products\/1sbl411024r8000\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eProduct description\u003c\/h2\u003e\n\u003cp\u003eUA75-30-00RA 220-230V 50Hz \/ 230-240V 60Hz Contactor\u003c\/p\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003cp\u003eSource: ABB Product Information System (PIS) - official ABB product data — https:\/\/www.abb.com\/global\/en\/products\/1sbl411024r8000\u003c\/p\u003e\n\u003ch3\u003eOrdering\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum Order Quantity\u003c\/th\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCustoms Tariff Number\u003c\/th\u003e\n\u003ctd\u003e85364900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Net Width\u003c\/th\u003e\n\u003ctd\u003e70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Net Depth \/ Length\u003c\/th\u003e\n\u003ctd\u003e140.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Net Height\u003c\/th\u003e\n\u003ctd\u003e150 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Net Weight\u003c\/th\u003e\n\u003ctd\u003e1.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimension Diagram\u003c\/th\u003e\n\u003ctd\u003eFPTE307844\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eTechnical\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Main Contacts NO\u003c\/th\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Main Contacts NC\u003c\/th\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Auxiliary Contacts NO\u003c\/th\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Auxiliary Contacts NC\u003c\/th\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Poles\u003c\/th\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eIEC\/EN 60947-1, IEC\/EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Operational Voltage\u003c\/th\u003e\n\u003ctd\u003eMain Circuit 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Frequency (f)\u003c\/th\u003e\n\u003ctd\u003eControl Circuit 50 \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Operational Power AC-6b (Pe)\u003c\/th\u003e\n\u003ctd\u003e(230 \/ 240 V) 40 °C, 50 \/ 60 Hz 35 kvar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShort-Circuit Protective Devices\u003c\/th\u003e\n\u003ctd\u003egG Type Fuses 200 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Breaking Capacity\u003c\/th\u003e\n\u003ctd\u003ecos phi=0.45 (cos phi=0.35 for Ie \u0026gt; 100 A) at 440 V 1300 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Insulation Voltage (Ui)\u003c\/th\u003e\n\u003ctd\u003eacc. to IEC 60947-4-1 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/th\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical Durability\u003c\/th\u003e\n\u003ctd\u003eUe =\u0026lt; 440 V 250000 cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Electrical Switching Frequency\u003c\/th\u003e\n\u003ctd\u003e240 cycles per hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Control Circuit Voltage (Uc)\u003c\/th\u003e\n\u003ctd\u003e50 Hz 220 ... 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCoil Consumption\u003c\/th\u003e\n\u003ctd\u003eAverage Holding Value 50 \/ 60 Hz 18 V·A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Loss\u003c\/th\u003e\n\u003ctd\u003eat Rated Operating Conditions per Pole 2.7 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperate Time\u003c\/th\u003e\n\u003ctd\u003eBetween Coil De-energization and NO Contact Opening 4 ... 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting on DIN Rail\u003c\/th\u003e\n\u003ctd\u003eTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting by Screws (not supplied)\u003c\/th\u003e\n\u003ctd\u003e2 x M6 Screws Placed Diagonally\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnecting Capacity Main Circuit\u003c\/th\u003e\n\u003ctd\u003eFlexible with Cable End 6 ... 10 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnecting Capacity Auxiliary Circuit\u003c\/th\u003e\n\u003ctd\u003eFlexible with Cable End 0.75 ... 2.5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of Protection\u003c\/th\u003e\n\u003ctd\u003eacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnecting Terminals (delivered in open position) Main Poles\u003c\/th\u003e\n\u003ctd\u003eM 6 (+,-) pozidriv 2 screws with 1x (13 x 10 mm) connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal Type\u003c\/th\u003e\n\u003ctd\u003eScrew Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Name\u003c\/th\u003e\n\u003ctd\u003eBlock Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eEnvironmental\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Air Temperature\u003c\/th\u003e\n\u003ctd\u003eClose to Contactor for Storage -60 ... +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClimatic Withstand\u003c\/th\u003e\n\u003ctd\u003eaccording to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 Specification II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Operating Altitude Permissible\u003c\/th\u003e\n\u003ctd\u003eWithout Derating 3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePollution Degree\u003c\/th\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eContainer Information\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePackage Level 1 Units\u003c\/th\u003e\n\u003ctd\u003ebox 1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePackage Level 1 Width\u003c\/th\u003e\n\u003ctd\u003e160 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePackage Level 1 Depth \/ Length\u003c\/th\u003e\n\u003ctd\u003e200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePackage Level 1 Height\u003c\/th\u003e\n\u003ctd\u003e85 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePackage Level 1 Gross Weight\u003c\/th\u003e\n\u003ctd\u003e1.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePackage Level 1 EAN\u003c\/th\u003e\n\u003ctd\u003e3471522305800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the rated supply voltage?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eMain Circuit 690 V\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSource: ABB Product Information System (PIS) - official ABB product data, field \"Rated Operational Voltage\" (https:\/\/www.abb.com\/global\/en\/products\/1sbl411024r8000)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow many poles \/ contacts does it have?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e3\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSource: ABB Product Information System (PIS) - official ABB product data, field \"Number of Main Contacts NO\" (https:\/\/www.abb.com\/global\/en\/products\/1sbl411024r8000)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the rated frequency?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eControl Circuit 50 \/ 60 Hz\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSource: ABB Product Information System (PIS) - official ABB product data, field \"Rated Frequency (f)\" (https:\/\/www.abb.com\/global\/en\/products\/1sbl411024r8000)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the degree of protection?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSource: ABB Product Information System (PIS) - official ABB product data, field \"Degree of Protection\" (https:\/\/www.abb.com\/global\/en\/products\/1sbl411024r8000)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the power rating?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(230 \/ 240 V) 40 °C, 50 \/ 60 Hz 35 kvar\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSource: ABB Product Information System (PIS) - official ABB product data, field \"Rated Operational Power AC-6b (Pe)\" (https:\/\/www.abb.com\/global\/en\/products\/1sbl411024r8000)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is it mounted?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSource: ABB Product Information System (PIS) - official ABB product data, field \"Mounting on DIN Rail\" (https:\/\/www.abb.com\/global\/en\/products\/1sbl411024r8000)\u003c\/em\u003e\u003c\/p\u003e\n\u003c!-- \u003c!-- \/ABB-PIS-OFFICIAL-DATA-BLOCK --\u003e --\u0026gt;","brand":"ABB","offers":[{"title":"New","offer_id":46125997949181,"sku":"AD1015","price":167.46,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/MaB5uyNmkauliRtV321rEB8W37DRDEOlsHWC8nD7RXU686RthQNpiBoWexPf.jpg?v=1742188017","url":"https:\/\/shly-plc.com\/products\/abb-ua75-30-00ra-220-230v-50hz-230-240v-60hz-1sbl411024r8000-installation-contactor","provider":"SHLY-PLC","version":"1.0","type":"link"}