{"product_id":"abb-pm5012-r-eth-1sap122700r0072-ac500-programmable-controller","title":"ABB PM5012-R-ETH 1SAP122700R0072 AC500 Programmable Controller","description":"\u003c!-- ABB-OFFICIAL-DATA-BLOCK --\u003e\n\u003cp\u003e\u003cstrong\u003eProduct identification\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e PM5012-R-ETH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlobal material number:\u003c\/strong\u003e 1SAP122700R0072\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct description\u003c\/h3\u003e\u003cp\u003eProcessor module. Memory 1MB. 6 DI 24 VDC. 4 DO-Relay. Ethernet interface. 1 option slot (PM5012-R-ETH)\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eSource: \u003ca href=\"https:\/\/www.abb.com\/global\/en\/products\/1sap122700r0072\" rel=\"nofollow\"\u003eABB official product page\u003c\/a\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cem\u003eSource: \u003ca href=\"https:\/\/library.e.abb.com\/public\/ddcd5b9a980b462cb7c5e0e67e978447\/3ADR010585_en_I_Data%20sheet%20PM50xx.pdf\" rel=\"nofollow\"\u003eABB Data sheet 3ADR010585\u003c\/a\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003ch4\u003eMechanical data\u003c\/h4\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eHorizontal\/vertical \u003csmall\u003e(4.5 Mechanical data)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWiring method\u003c\/th\u003e\n\u003ctd\u003eSpring\/screw terminals \u003csmall\u003e(4.5 Mechanical data)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003ePLC system: IP 20 ● With all modules or option boards plugged in. ● With all terminals plugged in. ● With all covers closed. \u003csmall\u003e(4.5 Mechanical data)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing\u003c\/th\u003e\n\u003ctd\u003eClassification V-0 according to UL 94 \u003csmall\u003e(4.5 Mechanical data)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration resistance (sinusoidal) acc. to IEC 60068-2-6\u003c\/th\u003e\n\u003ctd\u003eAll three axes 2 Hz ... 8.4 Hz, 3.5 mm peak, 8.4 Hz ... 150 Hz, 1 g \u003csmall\u003e(4.5 Mechanical data)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShock test acc. to IEC 60068-2-27\u003c\/th\u003e\n\u003ctd\u003eAll three axes 15 g, 11 ms, half-sinusoidal \u003csmall\u003e(4.5 Mechanical data)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting Rail Top Hat according to IEC 60715\u003c\/th\u003e\n\u003ctd\u003e35 mm, depth 7.5 mm or 15 mm \u003csmall\u003e(4.5 Mechanical data)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting with screws\u003c\/th\u003e\n\u003ctd\u003eM4 \u003csmall\u003e(4.5 Mechanical data)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eEnvironmental conditions\u003c\/h4\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e24 V (-15 %, +20 %) \u003csmall\u003e(4.1 Environmental conditions)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection against reverse polarity\u003c\/th\u003e\n\u003ctd\u003eYes \u003csmall\u003e(4.1 Environmental conditions)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e24 V (-15 %, +10 %) \u003csmall\u003e(4.1 Environmental conditions)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz (-6 %, +4 %) \u003csmall\u003e(4.1 Environmental conditions)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e100 V ... 240 V (-15 %, +10 %) \u003csmall\u003e(4.1 Environmental conditions)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC supply\u003c\/th\u003e\n\u003ctd\u003eInterruption \u0026lt; 10 ms, time between 2 interruptions \u0026gt; 1 s, PS2 \u003csmall\u003e(4.1 Environmental conditions)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC supply (only for analog option boards TA512x)\u003c\/th\u003e\n\u003ctd\u003eInterruption \u0026lt; 1 ms, time between 2 interruptions \u0026gt; 1s, PS1 \u003csmall\u003e(4.1 Environmental conditions)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eAdditional data\u003c\/h4\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eTable 7: Wide temperature ranges Option boards Configuration Processor \/ Operating tempera\u003c\/th\u003e\n\u003ctd\u003eDerating \u003csmall\u003e(4.1.2 Option boards)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHorizontal mounting Digital I\/O option boards TA5101-4DIW Not relevant PM5072-T-2ETHW \/ -40 °C ... +60 °C\u003c\/th\u003e\n\u003ctd\u003eNo derating \u003csmall\u003e(4.1.2 Option boards)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTA5105-4DOTW TA5110-2DI2DOW \/ +60 °C ... +70 °C\u003c\/th\u003e\n\u003ctd\u003eI\/O derating to 75 % Only 3 of 4 I\/O channels are allowed to be \u003csmall\u003e(4.1.2 Option boards)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAnalog input option boards TA5120-2AI-UIW Not relevant PM5072-T-2ETHW TA5123-2AI-RTW \/ -40 °C ... +60 °C\u003c\/th\u003e\n\u003ctd\u003eenergized simultaneously . No derating \u003csmall\u003e(4.1.2 Option boards)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTA5122-2AI-TCW Not relevant PM5072-T-2ETHW Analog output option boards \/ -40 °C ... +70 °C\u003c\/th\u003e\n\u003ctd\u003eNo derating \u003csmall\u003e(4.1.2 Option boards)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTA5126-2AO-UIW 0 V ... +10 V PM5072-T-2ETHW \/ -40 °C ... +60 °C\u003c\/th\u003e\n\u003ctd\u003eNo derating \u003csmall\u003e(4.1.2 Option boards)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e0 m A ... +20 m A PM5072-T-2ETHW \/ -40 °C ... +45 °C\u003c\/th\u003e\n\u003ctd\u003eNo derating Load: 0 W ... \u003csmall\u003e(4.1.2 Option boards)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e+45 °C ... +50 °C\u003c\/th\u003e\n\u003ctd\u003e500 W 50 % Load: 250 W ... 500 W \u003csmall\u003e(4.1.2 Option boards)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e2026\/08\/19 3ADR010585, 8, en_US\u003c\/th\u003e\n\u003ctd\u003e15 \u003csmall\u003e(4.1.2 Option boards)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRadiated emission according to IEC 61000-6-4 CISPR11, class A\u003c\/th\u003e\n\u003ctd\u003eYes \u003csmall\u003e(4.4 Electromagnetic compatibility)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConducted emission according to IEC 61000-6-4 CISPR11, class A\u003c\/th\u003e\n\u003ctd\u003eYes \u003csmall\u003e(4.4 Electromagnetic compatibility)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrostatic discharge (ESD) according to IEC 61000-4-2, criterion B\u003c\/th\u003e\n\u003ctd\u003eAir discharge: 8 kV Contact discharge: 6 kV \u003csmall\u003e(4.4 Electromagnetic compatibility)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the PM5012-R-ETH?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eA: Processor module. Memory 1MB. 6 DI 24 VDC. 4 DO-Relay. Ethernet interface. 1 option slot (PM5012-R-ETH) \u003cem\u003e(ABB official product page)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the degree of protection?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eA: PLC system: IP 20 ● With all modules or option boards plugged in. ● With all terminals plugged in. ● With all covers closed. \u003cem\u003e(Datasheet 3ADR010585, 4.5 Mechanical data)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the operating temperature range?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eA: Derating \u003cem\u003e(Datasheet 3ADR010585, 4.1.2 Option boards)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How is it mounted?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eA: Horizontal\/vertical \u003cem\u003e(Datasheet 3ADR010585, 4.5 Mechanical data)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the housing material?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eA: Classification V-0 according to UL 94 \u003cem\u003e(Datasheet 3ADR010585, 4.5 Mechanical data)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What vibration and shock ratings does it meet?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eA: All three axes 2 Hz ... 8.4 Hz, 3.5 mm peak, 8.4 Hz ... 150 Hz, 1 g \u003cem\u003e(Datasheet 3ADR010585, 4.5 Mechanical data)\u003c\/em\u003e\u003c\/p\u003e\n\u003c!-- \/ABB-OFFICIAL-DATA-BLOCK --\u003e","brand":"ABB","offers":[{"title":"New","offer_id":46125943521533,"sku":"1SAP122700R0072","price":325.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/plc_1SAP122700R0072_800_7040ee1e-0ba9-4038-957a-d93f40ab5c75.jpg?v=1792742191","url":"https:\/\/shly-plc.com\/products\/abb-pm5012-r-eth-1sap122700r0072-ac500-programmable-controller","provider":"SHLY-PLC","version":"1.0","type":"link"}