{"product_id":"abb-ls31p51b11-1sbv010151r1211-switch-disconnector","title":"ABB LS31P51B11 1SBV010151R1211 Switch-Disconnector","description":"\u003cp\u003e\u003cstrong\u003eABB product — LS31P51B11\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- \u003c!-- ABB-PIS-OFFICIAL-DATA-BLOCK --\u003e --\u0026gt;\n\u003ch2\u003eProduct identification\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel: LS31P51B11\u003c\/li\u003e\n\u003cli\u003eGlobal material number: 1SBV010151R1211\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSource: ABB Product Information System (PIS) - official ABB product data\u003c\/p\u003e\n\u003cp\u003eEvidence URL: \u003ca href=\"https:\/\/www.abb.com\/global\/en\/products\/1sbv010151r1211\"\u003ehttps:\/\/www.abb.com\/global\/en\/products\/1sbv010151r1211\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003cp\u003eSource: ABB Product Information System (PIS) - official ABB product data — https:\/\/www.abb.com\/global\/en\/products\/1sbv010151r1211\u003c\/p\u003e\n\u003ch3\u003eOrdering\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum Order Quantity\u003c\/th\u003e\n\u003ctd\u003e10 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCustoms Tariff Number\u003c\/th\u003e\n\u003ctd\u003e85364900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Net Width\u003c\/th\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Net Height\u003c\/th\u003e\n\u003ctd\u003e98.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Net Depth \/ Length\u003c\/th\u003e\n\u003ctd\u003e45.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Net Weight\u003c\/th\u003e\n\u003ctd\u003e0.092 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eTechnical\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eAction Type of the Contact Element (acc. to IEC 60947-5-1)\u003c\/th\u003e\n\u003ctd\u003eSnap Action Contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation Speed\u003c\/th\u003e\n\u003ctd\u003eacc. to IEC 60947-5-1 Max. 1.5 m\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation Torque\u003c\/th\u003e\n\u003ctd\u003eacc. to IEC 60947-5-1 Min. 0.1 N·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAngular Head Adjustment\u003c\/th\u003e\n\u003ctd\u003eadjustable head every 90°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAngular Lever Adjustment\u003c\/th\u003e\n\u003ctd\u003e10° in 10°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eB10d Value\u003c\/th\u003e\n\u003ctd\u003eOperations 30 Millions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClimatic Withstand\u003c\/th\u003e\n\u003ctd\u003eaccording to IEC 68-2-3 and Salty Mist according to IEC 68-2-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConventional Free-air Thermal Current (Ith)\u003c\/th\u003e\n\u003ctd\u003eacc. to IEC 60947-5-1, Θ = 40 °C 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnecting Capacity\u003c\/th\u003e\n\u003ctd\u003eBar AWG 20 ... AWG 14 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConsistency (Measured over 1 Million Operations)\u003c\/th\u003e\n\u003ctd\u003e0.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContact Element Form\u003c\/th\u003e\n\u003ctd\u003eZb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnecting Terminals (delivered in open position)\u003c\/th\u003e\n\u003ctd\u003eM3.5 (+,-) pozidriv 2 screw with cable clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of Protection\u003c\/th\u003e\n\u003ctd\u003eacc. to IEC 60529 IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical Shock Protection acc. to IEC 536\u003c\/th\u003e\n\u003ctd\u003eDouble insulation - Class II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlammability According to UL94\u003c\/th\u003e\n\u003ctd\u003eV-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Electrical Switching Frequency\u003c\/th\u003e\n\u003ctd\u003e3600 cycles per hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMechanical Durability\u003c\/th\u003e\n\u003ctd\u003e10 million\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting by Screws (not supplied)\u003c\/th\u003e\n\u003ctd\u003e2 x M4 Screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMovement to be Detected\u003c\/th\u003e\n\u003ctd\u003e30° Cam Translation Movement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Auxiliary Contacts NC\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Auxiliary Contacts NO\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber and Type of Bottom Cable Glands\u003c\/th\u003e\n\u003ctd\u003ePg 11 cable gland\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePilot Duty UL\/CSA\u003c\/th\u003e\n\u003ctd\u003eA600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePositive Opening Operation of NC Contact(s)\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/th\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Operational Current AC-15 (Ie)\u003c\/th\u003e\n\u003ctd\u003e(230 V AC) 3.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Frequency (f)\u003c\/th\u003e\n\u003ctd\u003eSupply Circuit 50 \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Insulation Voltage (Ui)\u003c\/th\u003e\n\u003ctd\u003eacc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Operational Current DC-13 (Ie)\u003c\/th\u003e\n\u003ctd\u003e(24 V) 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResistance Between Contacts\u003c\/th\u003e\n\u003ctd\u003e25 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShort-Circuit Protective Devices\u003c\/th\u003e\n\u003ctd\u003egG Type Fuses 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal Marking\u003c\/th\u003e\n\u003ctd\u003eaccording to EN 50013\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eEnvironmental\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Air Temperature\u003c\/th\u003e\n\u003ctd\u003eOperation -25 ... +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResistance to Shock acc. to IEC 60068-2-27\u003c\/th\u003e\n\u003ctd\u003eHalf-sine Pulse for 11 ms, No Change in Contact Position 50 m\/s²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResistance to Vibrations\u003c\/th\u003e\n\u003ctd\u003eNo Change in Position of Contacts Greater than 100 µs: 25g 10 ... 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eContainer Information\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePackage Level 1 Units\u003c\/th\u003e\n\u003ctd\u003ebox 1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePackage Level 1 Width\u003c\/th\u003e\n\u003ctd\u003e54 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePackage Level 1 Depth \/ Length\u003c\/th\u003e\n\u003ctd\u003e32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePackage Level 1 Height\u003c\/th\u003e\n\u003ctd\u003e118 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePackage Level 1 Gross Weight\u003c\/th\u003e\n\u003ctd\u003e0.106 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePackage Level 1 EAN\u003c\/th\u003e\n\u003ctd\u003e3471522000972\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the rated supply voltage?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e6 kV\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSource: ABB Product Information System (PIS) - official ABB product data, field \"Rated Impulse Withstand Voltage (Uimp)\" (https:\/\/www.abb.com\/global\/en\/products\/1sbv010151r1211)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the rated current?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eacc. to IEC 60947-5-1, Θ = 40 °C 10 A\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSource: ABB Product Information System (PIS) - official ABB product data, field \"Conventional Free-air Thermal Current (Ith)\" (https:\/\/www.abb.com\/global\/en\/products\/1sbv010151r1211)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow many poles \/ contacts does it have?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSource: ABB Product Information System (PIS) - official ABB product data, field \"Number of Auxiliary Contacts NC\" (https:\/\/www.abb.com\/global\/en\/products\/1sbv010151r1211)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the rated frequency?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e3600 cycles per hour\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSource: ABB Product Information System (PIS) - official ABB product data, field \"Maximum Electrical Switching Frequency\" (https:\/\/www.abb.com\/global\/en\/products\/1sbv010151r1211)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the degree of protection?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eacc. to IEC 60529 IP65\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSource: ABB Product Information System (PIS) - official ABB product data, field \"Degree of Protection\" (https:\/\/www.abb.com\/global\/en\/products\/1sbv010151r1211)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is it mounted?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e2 x M4 Screws\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSource: ABB Product Information System (PIS) - official ABB product data, field \"Mounting by Screws (not supplied)\" (https:\/\/www.abb.com\/global\/en\/products\/1sbv010151r1211)\u003c\/em\u003e\u003c\/p\u003e\n\u003c!-- \u003c!-- \/ABB-PIS-OFFICIAL-DATA-BLOCK --\u003e --\u0026gt;","brand":"ABB","offers":[{"title":"New","offer_id":46127709192445,"sku":"1SBV010151R1211","price":51.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/fixed_d0adce69-b4d6-4f53-938e-8d54009b7b87.jpg?v=1784955787","url":"https:\/\/shly-plc.com\/products\/abb-ls31p51b11-1sbv010151r1211-switch-disconnector","provider":"SHLY-PLC","version":"1.0","type":"link"}