{"product_id":"abb-esb63-40n-14-1sae351111r1440-installation-contactor","title":"ABB ESB63-40N-14 1SAE351111R1440 Installation Contactor","description":"\u003cp\u003e\u003cstrong\u003eABB product — ESB63-40N-14\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- \u003c!-- ABB-PLCDIRECT-DATA-BLOCK --\u003e --\u0026gt;\n\u003ch2\u003eProduct identification\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel: ESB63-40N-14\u003c\/li\u003e\n\u003cli\u003eGlobal material number: 1SAE351111R1440\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSource: PLC Direct (third-party listing of ABB official product data)\u003c\/p\u003e\n\u003cp\u003eEvidence URL: \u003ca href=\"https:\/\/plc-direct.com\/products\/1sae351111r1440\"\u003ehttps:\/\/plc-direct.com\/products\/1sae351111r1440\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003cp\u003eSource: PLC Direct (third-party listing of ABB official product data) — https:\/\/plc-direct.com\/products\/1sae351111r1440\u003c\/p\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Net Width\u003c\/th\u003e\n\u003ctd\u003e54 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Net Depth \/ Length\u003c\/th\u003e\n\u003ctd\u003e65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Net Height\u003c\/th\u003e\n\u003ctd\u003e85 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Net Weight\u003c\/th\u003e\n\u003ctd\u003e0.405 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eTechnical\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Main Contacts NO\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Main Contacts NC\u003c\/th\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Auxiliary Contacts NO\u003c\/th\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Auxiliary Contacts NC\u003c\/th\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Poles\u003c\/th\u003e\n\u003ctd\u003e4P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eIEC\/EN 60947-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Operational Voltage\u003c\/th\u003e\n\u003ctd\u003eMain Circuit 220 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Frequency (f)\u003c\/th\u003e\n\u003ctd\u003eControl Circuit 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Breaking Capacity AC-3\u003c\/th\u003e\n\u003ctd\u003e8 x Ie \/ AC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Making Capacity AC-3\u003c\/th\u003e\n\u003ctd\u003e10 x Ie \/ AC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical Durability\u003c\/th\u003e\n\u003ctd\u003eAC-1 (NO) 100000 cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Electrical Switching Frequency\u003c\/th\u003e\n\u003ctd\u003e(AC-1) 300 cycles per hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMechanical Durability\u003c\/th\u003e\n\u003ctd\u003eNr. Operations 1000000 cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCoil Operating Limits\u003c\/th\u003e\n\u003ctd\u003e(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCoil Consumption\u003c\/th\u003e\n\u003ctd\u003eAverage Holding Value 50 \/ 60 Hz 4.5 V·A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Loss\u003c\/th\u003e\n\u003ctd\u003eat Rated Operating Conditions AC-1 per Pole 4.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting on DIN Rail\u003c\/th\u003e\n\u003ctd\u003eTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnecting Capacity Main Circuit\u003c\/th\u003e\n\u003ctd\u003eFlexible with Ferrule 1x 1.5 ... 16 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnecting Capacity Control Circuit\u003c\/th\u003e\n\u003ctd\u003eFlexible with Ferrule 1x 0.75 ... 2.5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWire Stripping Length\u003c\/th\u003e\n\u003ctd\u003eControl Circuit 7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of Protection\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRecommended Screw Driver\u003c\/th\u003e\n\u003ctd\u003eControl Circuit Pozidriv 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTightening Torque\u003c\/th\u003e\n\u003ctd\u003eControl Circuit 0.9 N·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal Type\u003c\/th\u003e\n\u003ctd\u003eScrew Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth in Number of Modular Spacings\u003c\/th\u003e\n\u003ctd\u003e3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Name\u003c\/th\u003e\n\u003ctd\u003eInstallation Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eEnvironmental\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Air Temperature\u003c\/th\u003e\n\u003ctd\u003eOperation -25 ... +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Operating Altitude Permissible\u003c\/th\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResistance to Shock acc. to IEC 60068-2-27\u003c\/th\u003e\n\u003ctd\u003e11 ms Pulse 15g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePollution Degree\u003c\/th\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the rated supply voltage?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eMain Circuit 220 V DC\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSource: PLC Direct (third-party listing of ABB official product data), field \"Rated Operational Voltage\" (https:\/\/plc-direct.com\/products\/1sae351111r1440)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow many poles \/ contacts does it have?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e4\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSource: PLC Direct (third-party listing of ABB official product data), field \"Number of Main Contacts NO\" (https:\/\/plc-direct.com\/products\/1sae351111r1440)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the rated frequency?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eControl Circuit 400 Hz\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSource: PLC Direct (third-party listing of ABB official product data), field \"Rated Frequency (f)\" (https:\/\/plc-direct.com\/products\/1sae351111r1440)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the degree of protection?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIP20\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSource: PLC Direct (third-party listing of ABB official product data), field \"Degree of Protection\" (https:\/\/plc-direct.com\/products\/1sae351111r1440)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the power rating?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eat Rated Operating Conditions AC-1 per Pole 4.5 W\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSource: PLC Direct (third-party listing of ABB official product data), field \"Power Loss\" (https:\/\/plc-direct.com\/products\/1sae351111r1440)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is it mounted?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSource: PLC Direct (third-party listing of ABB official product data), field \"Mounting on DIN Rail\" (https:\/\/plc-direct.com\/products\/1sae351111r1440)\u003c\/em\u003e\u003c\/p\u003e\n\u003c!-- \u003c!-- \/ABB-PLCDIRECT-DATA-BLOCK --\u003e --\u0026gt;","brand":"ABB","offers":[{"title":"New","offer_id":46127568912637,"sku":"1SAE351111R1440","price":297.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/da7c5fee207cee63282f7960209cf1b2_0043fe1e-8ba3-4b9c-b671-5c76951808eb.jpg?v=1791730851","url":"https:\/\/shly-plc.com\/products\/abb-esb63-40n-14-1sae351111r1440-installation-contactor","provider":"SHLY-PLC","version":"1.0","type":"link"}