{"product_id":"abb-af80-30-00-41-1sbl397001r4100-af-contactor-af80","title":"ABB AF80-30-00-41 1SBL397001R4100 AF Contactor - AF80","description":"\u003cp\u003e\u003cstrong\u003eABB product — AF80-30-00-41\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- \u003c!-- ABB-DEALER-DATA-BLOCK --\u003e --\u0026gt;\n\u003ch2\u003eProduct identification\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel: AF80-30-00-41\u003c\/li\u003e\n\u003cli\u003eGlobal material number: 1SBL397001R4100\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSource: ABB official product data (dealer mirror: santaclarasystems.com)\u003c\/p\u003e\n\u003cp\u003eEvidence URL: \u003ca href=\"https:\/\/www.santaclarasystems.com\/abb\/1sbl397001r4100\"\u003ehttps:\/\/www.santaclarasystems.com\/abb\/1sbl397001r4100\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003cp\u003eSource: ABB official product data (dealer mirror: santaclarasystems.com) — https:\/\/www.santaclarasystems.com\/abb\/1sbl397001r4100\u003c\/p\u003e\n\u003ch3\u003eTechnical\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct ID\u003c\/th\u003e\n\u003ctd\u003e1SBL397001R4100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExtended Product Type\u003c\/th\u003e\n\u003ctd\u003e1SBL397001R4100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Net Weight\u003c\/th\u003e\n\u003ctd\u003e1.220 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Net Width\u003c\/th\u003e\n\u003ctd\u003e70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Net Height\u003c\/th\u003e\n\u003ctd\u003e125.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Net Depth\u003c\/th\u003e\n\u003ctd\u003e116 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of Protection\u003c\/th\u003e\n\u003ctd\u003eacc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Air Temperature\u003c\/th\u003e\n\u003ctd\u003eClose to Contactor for Storage -60...+80 °C Close to Contactor Fitted with Thermal O\/L Relay -25 ... +60 °C Close to Contactor without Thermal O\/L Relay -40 ... +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/th\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Insulation Voltage (Ui)\u003c\/th\u003e\n\u003ctd\u003eacc. to UL\/CSA 600 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal Type\u003c\/th\u003e\n\u003ctd\u003eScrew Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Frequency (f)\u003c\/th\u003e\n\u003ctd\u003eMain Circuit 50 \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Auxiliary Contacts NO\u003c\/th\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Auxiliary Contacts NC\u003c\/th\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnecting Capacity Main Circuit\u003c\/th\u003e\n\u003ctd\u003eFlexible with Insulated Ferrule 1\/2x 6...50 mm² Flexible with Ferrule 1\/2x 6...50 mm² Rigid 1x 6...70 mm² Rigid 2x 6...50 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Operating Altitude Permissible\u003c\/th\u003e\n\u003ctd\u003e3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Control Circuit Voltage (Uc)\u003c\/th\u003e\n\u003ctd\u003e50 Hz 24 ... 60 V 60 Hz 24 ... 60 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClimatic Withstand\u003c\/th\u003e\n\u003ctd\u003eCategory B according to IEC 60947-1 Annex Q\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTightening Torque UL\/CSA\u003c\/th\u003e\n\u003ctd\u003eControl Circuit 11 in·lb Main Circuit 53 in·lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Mechanical Switching Frequency\u003c\/th\u003e\n\u003ctd\u003e3600 cycles per hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperate Time\u003c\/th\u003e\n\u003ctd\u003eBetween Coil De-energization and NC Contact Closing 19 ... 105 ms Between Coil De-energization and NO Contact Opening 17 ... 100 ms Between Coil Energization and NC Contact Opening 38 ... 95 ms Between Coil Energization and NO Contact Closing 42 ... 100 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWire Stripping Length\u003c\/th\u003e\n\u003ctd\u003eMain Circuit 17 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Main Contacts NO\u003c\/th\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGL Certificate\u003c\/th\u003e\n\u003ctd\u003eDNV-GL_E13871\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Main Contacts NC\u003c\/th\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Breaking Capacity\u003c\/th\u003e\n\u003ctd\u003ecos phi=0.45 (cos phi=0.35 for Ie \u0026gt; 100 A) at 440 V 1150 A cos phi=0.45 (cos phi=0.35 for Ie \u0026gt; 100 A) at 690 V 750 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnecting Capacity Control Circuit\u003c\/th\u003e\n\u003ctd\u003eFlexible with Ferrule 1\/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² Rigid 1\/2x 1 ... 2.5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHorsepower Rating UL\/CSA\u003c\/th\u003e\n\u003ctd\u003e(120 V AC) Single Phase 7-1\/2 Hp (240 V AC) Single Phase 15 Hp (200 ... 208 V AC) Three Phase 25 Hp (220 ... 240 V AC) Three Phase 30 Hp (440 ... 480 V AC) Three Phase 60 Hp (550 ... 600 V AC) Three Phase 75 Hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGeneral Use Rating UL\/CSA\u003c\/th\u003e\n\u003ctd\u003e(600 V AC) 105 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEAN\u003c\/th\u003e\n\u003ctd\u003e3471523132900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Operational Voltage\u003c\/th\u003e\n\u003ctd\u003eMain Circuit 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConventional Free-air Thermal Current (Ith)\u003c\/th\u003e\n\u003ctd\u003eacc. to IEC 60947-4-1, Open Contactors q = 40 °C 130 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Operational Current AC-1 (Ie)\u003c\/th\u003e\n\u003ctd\u003e(690 V) 40 °C 125 A (690 V) 60 °C 100 A (690 V) 70 °C 85 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Operational Current AC-3 (Ie)\u003c\/th\u003e\n\u003ctd\u003e(220 \/ 230 \/ 240 V) 60 °C 80 A (380 \/ 400 V) 60 °C 80 A (415 V) 60 °C 80 A (440 V) 60 °C 80 A (500 V) 60 °C 65 A (690 V) 60 °C 49 A (1000 V) 60 °C 25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Operational Power AC-3 (Pe)\u003c\/th\u003e\n\u003ctd\u003e(220 \/ 230 \/ 240 V) 22 kW (380 \/ 400 V) 37 kW (400 V) 37 kW (415 V) 45 kW (440 V) 45 kW (500 V) 45 kW (690 V) 45 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Electrical Switching Frequency\u003c\/th\u003e\n\u003ctd\u003eAC-1 600 cycles per hour AC-2 \/ AC-4 150 cycles per hour AC-3 1200 cycles per hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResistance to Vibrations acc. to IEC 60068-2-6\u003c\/th\u003e\n\u003ctd\u003e5...300 Hz 3 g closed position \/ 3 g open position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResistance to Shock acc. to IEC 60068-2-27\u003c\/th\u003e\n\u003ctd\u003eClosed, Shock Direction: A 25 g Closed, Shock Direction: B1 25 g Closed, Shock Direction: B2 15 g Closed, Shock Direction: C1 25 g Closed, Shock Direction: C2 25 g Open, Shock Direction: B1 5 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstructions and Manuals\u003c\/th\u003e\n\u003ctd\u003e1SBC101036M6801\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eABS Certificate\u003c\/th\u003e\n\u003ctd\u003eABS_15-GE1349500-PDA_90682247\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBV Certificate\u003c\/th\u003e\n\u003ctd\u003eBV_2634H36994A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCB Certificate\u003c\/th\u003e\n\u003ctd\u003eCB_SE-77417M1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCCC Certificate\u003c\/th\u003e\n\u003ctd\u003eCCC_2013010304646569\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ecUL Certificate\u003c\/th\u003e\n\u003ctd\u003eUL_20130926-E312527_14_1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eData Sheet, Technical Information\u003c\/th\u003e\n\u003ctd\u003e1SBC100173C0201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDeclaration of Conformity - CE\u003c\/th\u003e\n\u003ctd\u003e1SBD250000U1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDNV Certificate\u003c\/th\u003e\n\u003ctd\u003eDNV-GL_E13871\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEAC Certificate\u003c\/th\u003e\n\u003ctd\u003eEAC_RU C-FR ME77 B01010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLR Certificate\u003c\/th\u003e\n\u003ctd\u003eLRS_1300087E1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRINA Certificate\u003c\/th\u003e\n\u003ctd\u003eRINA_ELE084013XG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRMRS Certificate\u003c\/th\u003e\n\u003ctd\u003eRMRS_1400682124\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUNSPSC\u003c\/th\u003e\n\u003ctd\u003e39121529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eObject Classification Code\u003c\/th\u003e\n\u003ctd\u003eQ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the rated supply voltage?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e8 kV\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSource: ABB official product data (dealer mirror: santaclarasystems.com), field \"Rated Impulse Withstand Voltage (Uimp)\" (https:\/\/www.santaclarasystems.com\/abb\/1sbl397001r4100)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the rated current?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eacc. to IEC 60947-4-1, Open Contactors q = 40 °C 130 A\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSource: ABB official product data (dealer mirror: santaclarasystems.com), field \"Conventional Free-air Thermal Current (Ith)\" (https:\/\/www.santaclarasystems.com\/abb\/1sbl397001r4100)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow many poles \/ contacts does it have?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e0\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSource: ABB official product data (dealer mirror: santaclarasystems.com), field \"Number of Auxiliary Contacts NO\" (https:\/\/www.santaclarasystems.com\/abb\/1sbl397001r4100)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the rated frequency?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eMain Circuit 50 \/ 60 Hz\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSource: ABB official product data (dealer mirror: santaclarasystems.com), field \"Rated Frequency (f)\" (https:\/\/www.santaclarasystems.com\/abb\/1sbl397001r4100)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the degree of protection?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eacc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSource: ABB official product data (dealer mirror: santaclarasystems.com), field \"Degree of Protection\" (https:\/\/www.santaclarasystems.com\/abb\/1sbl397001r4100)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the power rating?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(120 V AC) Single Phase 7-1\/2 Hp (240 V AC) Single Phase 15 Hp (200 ... 208 V AC) Three Phase 25 Hp (220 ... 240 V AC) Three Phase 30 Hp (440 ... 480 V AC) Three Phase 60 Hp (550 ... 600 V AC) Three Phase 75 Hp\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSource: ABB official product data (dealer mirror: santaclarasystems.com), field \"Horsepower Rating UL\/CSA\" (https:\/\/www.santaclarasystems.com\/abb\/1sbl397001r4100)\u003c\/em\u003e\u003c\/p\u003e\n\u003c!-- \u003c!-- \/ABB-PIS-OFFICIAL-DATA-BLOCK --\u003e --\u0026gt;","brand":"ABB","offers":[{"title":"New","offer_id":46127698444541,"sku":"1SBL397001R4100","price":149.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/915075b081707517e197e57bef78c8ba_bd16f11c-7532-4785-8f62-36021646e8b8.jpg?v=1791731066","url":"https:\/\/shly-plc.com\/products\/abb-af80-30-00-41-1sbl397001r4100-af-contactor-af80","provider":"SHLY-PLC","version":"1.0","type":"link"}