{"product_id":"abb-acs150-01e-04a7-2-3abd68865573-vfd-drive","title":"ABB ACS150-01E-04A7-2 3ABD68865573 VFD Drive","description":"\u003cstyle\u003e.shly-pdp{--ink:#1c2024;--muted:#5b6570;--line:#dfe3e8;--bg:#fff;--soft:#f6f7f9;--accent:#C8102E;max-width:1000px;margin:0 auto;padding:4px 0 32px;color:var(--ink);font-family:-apple-system,\"Segoe UI\",Roboto,Helvetica,Arial,sans-serif;line-height:1.62;font-size:15.5px;-webkit-text-size-adjust:100%;}\n.shly-pdp *{box-sizing:border-box;}\n.shly-pdp h3{font-size:17px;font-weight:700;margin:34px 0 12px;padding:0 0 8px;border-bottom:1px solid var(--line);letter-spacing:.2px;}\n.shly-pdp p{margin:0 0 12px;}\n.shly-pdp .shly-eyebrow{font-size:11.5px;letter-spacing:1.6px;text-transform:uppercase;color:var(--accent);font-weight:700;margin:0 0 8px;}\n.shly-pdp .shly-lead{font-size:16.5px;line-height:1.68;color:#2b3138;margin:0 0 4px;}\n.shly-pdp .shly-lead b{font-weight:700;}\n.shly-pdp .shly-facts{list-style:none;margin:14px 0 0;padding:0;display:grid;grid-template-columns:repeat(4,1fr);gap:1px;background:var(--line);border:1px solid var(--line);border-radius:6px;overflow:hidden;}\n.shly-pdp .shly-facts li{background:var(--soft);padding:12px 14px;font-size:13.5px;line-height:1.45;}\n.shly-pdp .shly-facts span{display:block;font-size:11px;text-transform:uppercase;letter-spacing:.9px;color:var(--muted);margin-bottom:4px;}\n.shly-pdp .shly-facts strong{font-weight:700;font-size:14.5px;}\n.shly-pdp table{width:100%;border-collapse:collapse;margin:6px 0 10px;font-size:14.5px;table-layout:fixed;}\n.shly-pdp th,.shly-pdp td{text-align:left;vertical-align:top;padding:9px 12px;border-bottom:1px solid var(--line);word-break:break-word;}\n.shly-pdp th{width:38%;font-weight:600;color:#333a41;background:#fafbfc;}\n.shly-pdp tr.shly-group td{background:#eef1f4;font-size:11.5px;letter-spacing:1.3px;text-transform:uppercase;font-weight:700;color:#48525c;padding:7px 12px;}\n.shly-pdp .shly-note{font-size:13.5px;color:var(--muted);border-left:3px solid var(--line);padding:2px 0 2px 12px;margin:10px 0 0;}\n.shly-pdp ul.shly-list{margin:8px 0 0;padding:0 0 0 20px;}\n.shly-pdp ul.shly-list li{margin:0 0 8px;}\n.shly-pdp .shly-q{border-top:1px solid var(--line);padding:14px 0 2px;}\n.shly-pdp .shly-q:first-of-type{border-top:none;}\n.shly-pdp .shly-q p{margin:0 0 6px;}\n.shly-pdp .shly-q .shly-qq{font-weight:700;color:#1c2024;}\n.shly-pdp .shly-q .shly-qq em{font-style:normal;color:var(--accent);margin-right:6px;}\n@media (max-width:720px){\n.shly-pdp{font-size:15px;}\n.shly-pdp .shly-facts{grid-template-columns:repeat(2,1fr);}\n.shly-pdp th,.shly-pdp td{padding:8px 10px;font-size:14px;}\n.shly-pdp th{width:42%;}\n}\u003c\/style\u003e\u003cdiv class=\"shly-pdp\"\u003e\n\u003cp class=\"shly-eyebrow\"\u003eABB · ACS150 micro drive\u003c\/p\u003e\n\u003cp class=\"shly-lead\"\u003e\u003cb\u003eACS150-01E-04A7-2\u003c\/b\u003e is an ABB variable-frequency drive with Overload capacity 150 % for 60 s (IEC 61800-2); Enclosure rating IP20 (IEC 60529); Frequency 50\/60 Hz (IEC 61800-2). It is used in pump sets, conveyor belts, fan and compressor drives where the installed unit is matched to the original catalog number and a compact, documented part is required.\u003c\/p\u003e\n\u003cul class=\"shly-facts\"\u003e\n\u003cli\u003e\n\u003cspan\u003eOverload capacity\u003c\/span\u003e\u003cstrong\u003e150 % for 60 s (IEC 61800-2)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eEnclosure rating\u003c\/span\u003e\u003cstrong\u003eIP20 (IEC 60529)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eFrequency\u003c\/span\u003e\u003cstrong\u003e50\/60 Hz (IEC 61800-2)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eRated current Ie\u003c\/span\u003e\u003cstrong\u003e4.7 A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eElectrical\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated current Ie\u003c\/th\u003e\n\u003ctd\u003e4.7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply voltage\u003c\/th\u003e\n\u003ctd\u003e1-phase 200...240 V \/ 3-phase 380...480 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput voltage range\u003c\/th\u003e\n\u003ctd\u003e200 ... 240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower consumption\u003c\/th\u003e\n\u003ctd\u003e54 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEfficiency\u003c\/th\u003e\n\u003ctd\u003eIE2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz (IEC 61800-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl method\u003c\/th\u003e\n\u003ctd\u003eV\/f, sensorless vector (IEC 61800-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOverload capacity\u003c\/th\u003e\n\u003ctd\u003e150 % for 60 s (IEC 61800-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eI\/O and communication\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication ports\u003c\/th\u003e\n\u003ctd\u003eModbus, PROFINET, Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eMechanical\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e1.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eModule for cabinet building\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure rating\u003c\/th\u003e\n\u003ctd\u003eIP20 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"2\"\u003eEnvironment and compliance\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-10...+60 °C (IEC 60068-2-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertifications\u003c\/th\u003e\n\u003ctd\u003eCE, UL, CSA, CCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp class=\"shly-note\"\u003eValues follow the ABB ACS150 micro drive specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.\u003c\/p\u003e\n\u003cp class=\"shly-note\"\u003eLifecycle: discontinued by the manufacturer. Current-production replacement: \u003cb\u003eACS180\u003c\/b\u003e. Cross-reference by function and ratings, not by label alone.\u003c\/p\u003e\n\u003ch3\u003eModel comparison in the same family\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr class=\"shly-group\"\u003e\u003ctd colspan=\"4\"\u003eABB ACS150 micro drive variants\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:26%\"\u003eCatalog number\u003c\/th\u003e\n\u003cth style=\"width:24%\"\u003eOverload capacity\u003c\/th\u003e\n\u003cth style=\"width:24%\"\u003eFrequency\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cb\u003eACS150-01E-04A7-2\u003c\/b\u003e (this page)\u003c\/td\u003e\n\u003ctd\u003e150 % for 60 s (IEC 61800-2)\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz (IEC 61800-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/abb-acs150-01e-02a4-2-3abd00046470-ac-frequency-drive-variable-speed-drive\"\u003eACS150-01E-02A4-2\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/abb-acs150-01e-09a8-2-3abd68581991-ac-micro-drive\"\u003eACS150-01E-09A8-2\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2.2 kW\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/abb-acs-ap-s-acs580-control-panel\"\u003eACS-AP-S\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp class=\"shly-note\"\u003eAll variants share the same ACS150 micro drive footprint and terminal layout; the columns above show where they differ. Selecting a different catalog number changes the electrical interface, not the mounting.\u003c\/p\u003e\n\u003ch3\u003eWhere it sits in the control system\u003c\/h3\u003e\n\u003cp\u003eThe ACS150-01E-04A7-2 is the device-level element in an ABB variable-frequency drive installation. It receives the field signals and control supply listed above — 1-phase 200...240 V \/ 3-phase 380...480 V AC — and switches or conditions the load within the 4.7 A ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.\u003c\/p\u003e\n\u003cp\u003eTypical installations place it in pump sets, conveyor belts, fan and compressor drives, where the unit is matched to the original catalog number and the enclosure provides Module for cabinet building support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.\u003c\/p\u003e\n\u003ch3\u003eBefore you specify\u003c\/h3\u003e\n\u003cul class=\"shly-list\"\u003e\n\u003cli\u003e\n\u003cb\u003eRatings.\u003c\/b\u003e Confirm the rated current and voltage match the circuit before specifying; sizing from the nameplate avoids field mismatch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMounting.\u003c\/b\u003e Check the Module for cabinet building fit against the existing enclosure before ordering.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMarking.\u003c\/b\u003e Record the catalog number and revision from the nameplate of the installed unit for a like-for-like spare.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhat supply does this device require?\u003c\/p\u003e\n\u003cp\u003eIt requires 1-phase 200...240 V \/ 3-phase 380...480 V AC. Size the supply source to the same rating shown in the Specifications table.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhat are the key electrical ratings?\u003c\/p\u003e\n\u003cp\u003eThe confirmed ratings include 4.7 A and CE, UL, CSA, CCC marking. Cross-check them against the installed unit's nameplate.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eHow is this device mounted?\u003c\/p\u003e\n\u003cp\u003eIt mounts by Module for cabinet building. Confirm the cutout or rail before ordering a like-for-like spare.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eWhat is the operating temperature range?\u003c\/p\u003e\n\u003cp\u003eThe confirmed operating range is -10...+60 °C (IEC 60068-2-1). Panels running beyond it need derated sizing.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"shly-q\"\u003e\n\u003cp class=\"shly-qq\"\u003e\u003cem\u003eQ.\u003c\/em\u003eIs this catalog number still in production, and what replaces it?\u003c\/p\u003e\n\u003cp\u003eIt is discontinued by the manufacturer; the current-production replacement is ACS180. Cross-reference by function and ratings, not by label alone.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"New","offer_id":46125960528125,"sku":"ACS150-01E-04A7-2","price":252.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/ACS150-01E-04A7-2.png?v=1790178712","url":"https:\/\/shly-plc.com\/products\/abb-acs150-01e-04a7-2-3abd68865573-vfd-drive","provider":"SHLY-PLC","version":"1.0","type":"link"}