{"product_id":"abb-a9-30-10-1sbl141001r8810-power-contactor","title":"ABB A9-30-10 1SBL141001R8810 Power Contactor","description":"\u003cp\u003e\u003cstrong\u003eABB product — A9-30-10\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- \u003c!-- ABB-DEALER-DATA-BLOCK --\u003e --\u0026gt;\n\u003ch2\u003eProduct identification\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel: A9-30-10\u003c\/li\u003e\n\u003cli\u003eGlobal material number: 1SBL141001R8810\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSource: ABB official product data (dealer mirror: santaclarasystems.com)\u003c\/p\u003e\n\u003cp\u003eEvidence URL: \u003ca href=\"https:\/\/www.santaclarasystems.com\/abb\/1sbl141001r8810\"\u003ehttps:\/\/www.santaclarasystems.com\/abb\/1sbl141001r8810\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003cp\u003eSource: ABB official product data (dealer mirror: santaclarasystems.com) — https:\/\/www.santaclarasystems.com\/abb\/1sbl141001r8810\u003c\/p\u003e\n\u003ch3\u003eTechnical\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct ID\u003c\/th\u003e\n\u003ctd\u003e1SBL141001R8810\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExtended Product Type\u003c\/th\u003e\n\u003ctd\u003e1SBL141001R8810\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Net Weight\u003c\/th\u003e\n\u003ctd\u003e0.340 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Net Width\u003c\/th\u003e\n\u003ctd\u003e44 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Net Height\u003c\/th\u003e\n\u003ctd\u003e74 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Net Depth\u003c\/th\u003e\n\u003ctd\u003e74 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of Protection\u003c\/th\u003e\n\u003ctd\u003eacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Air Temperature\u003c\/th\u003e\n\u003ctd\u003eClose to Contactor Fitted with Thermal O\/L Relay -25 ... +55 °C Close to Contactor for Storage -60 ... +80 °C Close to Contactor without Thermal O\/L Relay (0.85 ... 1.1 Uc) -40 ... +55 °C Close to Contactor without Thermal O\/L Relay (Uc) -40 ... +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eDevices complying with international standards IEC 947-1 \/ 947-4-1, and European standards EN 60 947-1 \/ 60 947-4-1. Electromagnetic compatibility (EMC) acc. to amendment A11 to IEC 947-1; EN 60 947-1 and amendment 2 to IEC 947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/th\u003e\n\u003ctd\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Insulation Voltage (Ui)\u003c\/th\u003e\n\u003ctd\u003eacc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL\/CSA 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal Type\u003c\/th\u003e\n\u003ctd\u003eScrew Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Frequency (f)\u003c\/th\u003e\n\u003ctd\u003eSupply Circuit 50 Hz Supply Circuit 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Auxiliary Contacts NO\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Auxiliary Contacts NC\u003c\/th\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMechanical Durability\u003c\/th\u003e\n\u003ctd\u003e10 million\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnecting Capacity Main Circuit\u003c\/th\u003e\n\u003ctd\u003eFlexible with Cable End 0.75 ... 2.5 mm² Rigid Cable 1 ... 4 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGOST Certificate\u003c\/th\u003e\n\u003ctd\u003eGOST_POCCFRME77B07175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Operating Altitude Permissible\u003c\/th\u003e\n\u003ctd\u003e3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Control Circuit Voltage (Uc)\u003c\/th\u003e\n\u003ctd\u003e50 Hz 230 … 240 V 60 Hz 240 … 260 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eClimatic Withstand\u003c\/th\u003e\n\u003ctd\u003eacc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Mechanical Switching Frequency\u003c\/th\u003e\n\u003ctd\u003e3600 cycles per hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnecting Capacity Auxiliary Circuit\u003c\/th\u003e\n\u003ctd\u003eFlexible with Cable End 0.75 ... 2.5 mm² Rigid Cable 1 ... 4 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperate Time\u003c\/th\u003e\n\u003ctd\u003eBetween Coil Energization and NO Contact Closing 10 ... 26 ms Between Coil De-energization and NO Contact Opening 4 ... 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Main Contacts NO\u003c\/th\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGL Certificate\u003c\/th\u003e\n\u003ctd\u003eDNV-GL_TAE00000TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Main Contacts NC\u003c\/th\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShort-Circuit Protective Devices\u003c\/th\u003e\n\u003ctd\u003eAuxiliary Circuit - gG Type Fuses 10 A gG Type Fuses 25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Breaking Capacity\u003c\/th\u003e\n\u003ctd\u003ecos phi=0.45 (cos phi=0.35 for Ie \u0026gt; 100 A) at 440 V 250 A cos phi=0.45 (cos phi=0.35 for Ie \u0026gt; 100 A) at 690 V 90 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCoil Consumption\u003c\/th\u003e\n\u003ctd\u003eAverage Holding Value 50 \/ 60 Hz 8 V·A Average Holding Value 50 \/ 60 Hz 2 W Average Pull-in Value 50 Hz 74 V·A Average Pull-in Value 60 Hz 70 V·A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCoil Operating Limits\u003c\/th\u003e\n\u003ctd\u003e(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C) °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnecting terminals (delivered in open position) Main poles\u003c\/th\u003e\n\u003ctd\u003eM 3.5 (+,-) pozidriv 2 screws with cable clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEAN\u003c\/th\u003e\n\u003ctd\u003e3471522031884\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Operational Voltage\u003c\/th\u003e\n\u003ctd\u003eMain Circuit 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConventional Free-air Thermal Current (Ith)\u003c\/th\u003e\n\u003ctd\u003eacc. to IEC 60947-4-1, Open Contactors q = 40 °C 26 A acc. to IEC 60947-5-1, q = 40 °C 16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Operational Current AC-1 (Ie)\u003c\/th\u003e\n\u003ctd\u003e(690 V) 40 °C 25 A (690 V) 55 °C 22 A (690 V) 70 °C 18 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Operational Current AC-3 (Ie)\u003c\/th\u003e\n\u003ctd\u003e(220 \/ 230 \/ 240 V) 55 °C 9 A (380 \/ 400 V) 55 °C 9 A (415 V) 55 °C 9 A (440 V) 55 °C 9 A (500 V) 55 °C 9 A (690 V) 55 °C 7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Operational Power AC-3 (Pe)\u003c\/th\u003e\n\u003ctd\u003e(220 \/ 230 \/ 240 V) 2.2 kW (380 \/ 400 V) 4 kW (415 V) 4 kW (440 V) 4 kW (500 V) 5.5 kW (690 V) 5.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Breaking Capacity AC-3 acc. to IEC 60947-4-1\u003c\/th\u003e\n\u003ctd\u003e8 x Ie AC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Making Capacity AC-3 acc. to IEC 60947-4-1\u003c\/th\u003e\n\u003ctd\u003e10 x Ie AC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Operational Current AC-15 (Ie)\u003c\/th\u003e\n\u003ctd\u003e(220 \/ 240 V) 4 A (24 \/ 127 V) 6 A (380 \/ 440 V) 3 A (500 V) 2 A (690 V) 2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Electrical Switching Frequency\u003c\/th\u003e\n\u003ctd\u003eAC-1 600 cycles per hour AC-2 \/ AC-4 300 cycles per hour AC-3 1200 cycles per hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Operational Current DC-13 (Ie)\u003c\/th\u003e\n\u003ctd\u003e(125 V) 1.1 \/ 138 A (24 V) 6 \/ 144 A (250 V) 0.55 \/ 138 A (48 V) 2.8 \/ 134 A (72 V) 2 \/ 144 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResistance to Shock acc. to IEC 60068-2-27\u003c\/th\u003e\n\u003ctd\u003eShock Direction: A 20 g Closed, Shock Direction: B1 10 g Open, Shock Direction: B1 5 g Shock Direction: B2 15 g Shock Direction: C1 20 g Shock Direction: C2 20 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInstructions and Manuals\u003c\/th\u003e\n\u003ctd\u003eFPTC407721P0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBV Certificate\u003c\/th\u003e\n\u003ctd\u003eBV_2634H07559D0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCB Certificate\u003c\/th\u003e\n\u003ctd\u003eCB_FR_602227A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCCC Certificate\u003c\/th\u003e\n\u003ctd\u003eCCC_2013010304615753 CCC_2004010309130463\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ecUL Certificate\u003c\/th\u003e\n\u003ctd\u003eUL_20160205-E312527-10-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eData Sheet, Technical Information\u003c\/th\u003e\n\u003ctd\u003e1SBC100122C0202_Ch02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDeclaration of Conformity - CE\u003c\/th\u003e\n\u003ctd\u003e1SBD250801U1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDNV Certificate\u003c\/th\u003e\n\u003ctd\u003eDNV-GL_TAE00000TX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEAC Certificate\u003c\/th\u003e\n\u003ctd\u003eEAC_RU C-FR ME77 B01010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLOVAG Certificate\u003c\/th\u003e\n\u003ctd\u003eLOVAG_FR97037\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLR Certificate\u003c\/th\u003e\n\u003ctd\u003eLRS_9830011E4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRINA Certificate\u003c\/th\u003e\n\u003ctd\u003eRINA_ELE128713XG001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRMRS Certificate\u003c\/th\u003e\n\u003ctd\u003eRMRS_0507015250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eE-nummer\u003c\/th\u003e\n\u003ctd\u003e3227685\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUNSPSC\u003c\/th\u003e\n\u003ctd\u003e39121529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eObject Classification Code\u003c\/th\u003e\n\u003ctd\u003eQ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the rated supply voltage?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e8 kV\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSource: ABB official product data (dealer mirror: santaclarasystems.com), field \"Rated Impulse Withstand Voltage (Uimp)\" (https:\/\/www.santaclarasystems.com\/abb\/1sbl141001r8810)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the rated current?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eacc. to IEC 60947-4-1, Open Contactors q = 40 °C 26 A acc. to IEC 60947-5-1, q = 40 °C 16 A\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSource: ABB official product data (dealer mirror: santaclarasystems.com), field \"Conventional Free-air Thermal Current (Ith)\" (https:\/\/www.santaclarasystems.com\/abb\/1sbl141001r8810)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow many poles \/ contacts does it have?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSource: ABB official product data (dealer mirror: santaclarasystems.com), field \"Number of Auxiliary Contacts NO\" (https:\/\/www.santaclarasystems.com\/abb\/1sbl141001r8810)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the rated frequency?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eSupply Circuit 50 Hz Supply Circuit 60 Hz\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSource: ABB official product data (dealer mirror: santaclarasystems.com), field \"Rated Frequency (f)\" (https:\/\/www.santaclarasystems.com\/abb\/1sbl141001r8810)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the degree of protection?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSource: ABB official product data (dealer mirror: santaclarasystems.com), field \"Degree of Protection\" (https:\/\/www.santaclarasystems.com\/abb\/1sbl141001r8810)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the power rating?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(220 \/ 230 \/ 240 V) 2.2 kW (380 \/ 400 V) 4 kW (415 V) 4 kW (440 V) 4 kW (500 V) 5.5 kW (690 V) 5.5 kW\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSource: ABB official product data (dealer mirror: santaclarasystems.com), field \"Rated Operational Power AC-3 (Pe)\" (https:\/\/www.santaclarasystems.com\/abb\/1sbl141001r8810)\u003c\/em\u003e\u003c\/p\u003e\n\u003c!-- \u003c!-- \/ABB-PIS-OFFICIAL-DATA-BLOCK --\u003e --\u0026gt;","brand":"ABB","offers":[{"title":"New","offer_id":46127663743229,"sku":"1SBL141001R8810","price":218.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/07f77bd59b938fa6675250d5e5723d0c_a5f47b10-9478-4d78-ba7d-3702df5af983.jpg?v=1791731839","url":"https:\/\/shly-plc.com\/products\/abb-a9-30-10-1sbl141001r8810-power-contactor","provider":"SHLY-PLC","version":"1.0","type":"link"}