{"product_id":"abb-a300-30-11-84-1sfl551001r8411-contactor","title":"ABB A300-30-11-84 1SFL551001R8411 Contactor","description":"\u003cp\u003e\u003cstrong\u003eABB product — A300-30-11-84\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- \u003c!-- ABB-PLCDIRECT-DATA-BLOCK --\u003e --\u0026gt;\n\u003ch2\u003eProduct identification\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel: A300-30-11-84\u003c\/li\u003e\n\u003cli\u003eGlobal material number: 1SFL551001R8411\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSource: PLC Direct (third-party listing of ABB official product data)\u003c\/p\u003e\n\u003cp\u003eEvidence URL: \u003ca href=\"https:\/\/plc-direct.com\/products\/1sfl551001r8411\"\u003ehttps:\/\/plc-direct.com\/products\/1sfl551001r8411\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003cp\u003eSource: PLC Direct (third-party listing of ABB official product data) — https:\/\/plc-direct.com\/products\/1sfl551001r8411\u003c\/p\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Net Width\u003c\/th\u003e\n\u003ctd\u003e140 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Net Depth \/ Length\u003c\/th\u003e\n\u003ctd\u003e180.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Net Height\u003c\/th\u003e\n\u003ctd\u003e227 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Net Weight\u003c\/th\u003e\n\u003ctd\u003e5.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eTechnical\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Main Contacts NO\u003c\/th\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Main Contacts NC\u003c\/th\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Auxiliary Contacts NO\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Auxiliary Contacts NC\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Poles\u003c\/th\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Operational Voltage\u003c\/th\u003e\n\u003ctd\u003eMain Circuit 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Frequency (f)\u003c\/th\u003e\n\u003ctd\u003eMain Circuit 50 \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Breaking Capacity AC-3\u003c\/th\u003e\n\u003ctd\u003e8 x Ie AC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Making Capacity AC-3\u003c\/th\u003e\n\u003ctd\u003e10 x Ie AC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShort-Circuit Protective Devices\u003c\/th\u003e\n\u003ctd\u003egG Type Fuses 500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Breaking Capacity\u003c\/th\u003e\n\u003ctd\u003ecos phi=0.45 (cos phi=0.35 for Ie \u0026gt; 100 A) at 440 V 3000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Electrical Switching Frequency\u003c\/th\u003e\n\u003ctd\u003e(AC-1) 300 cycles per hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMechanical Durability\u003c\/th\u003e\n\u003ctd\u003e5 million\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Mechanical Switching Frequency\u003c\/th\u003e\n\u003ctd\u003e3600 cycles per hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCoil Operating Limits\u003c\/th\u003e\n\u003ctd\u003e(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCoil Consumption\u003c\/th\u003e\n\u003ctd\u003eHolding at Max. Rated Control Circuit Voltage 50 Hz 60 V·A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Loss\u003c\/th\u003e\n\u003ctd\u003eat Rated Operating Conditions per Pole 18 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperate Time\u003c\/th\u003e\n\u003ctd\u003eBetween Coil De-energization and NC Contact Closing 7 ... 13 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnecting Capacity Main Circuit\u003c\/th\u003e\n\u003ctd\u003eBar 32 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnecting Capacity Auxiliary Circuit\u003c\/th\u003e\n\u003ctd\u003eFlexible with Ferrule 1x 0.75 ... 2.5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnecting Capacity\u003c\/th\u003e\n\u003ctd\u003eBar 32 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of Protection\u003c\/th\u003e\n\u003ctd\u003eacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnecting Terminals (delivered in open position) Main Poles\u003c\/th\u003e\n\u003ctd\u003eFlat type c\/w screws and bolts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTightening Torque\u003c\/th\u003e\n\u003ctd\u003eMain Circuit 28 N·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal Type\u003c\/th\u003e\n\u003ctd\u003eMain Circuit: Bars\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Name\u003c\/th\u003e\n\u003ctd\u003eBlock Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eEnvironmental\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Air Temperature\u003c\/th\u003e\n\u003ctd\u003eClose to Contactor Fitted with Thermal O\/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Operating Altitude Permissible\u003c\/th\u003e\n\u003ctd\u003eWithout Derating 3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResistance to Shock acc. to IEC 60068-2-27\u003c\/th\u003e\n\u003ctd\u003eShock Direction: A 5 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the rated supply voltage?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eMain Circuit 690 V\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSource: PLC Direct (third-party listing of ABB official product data), field \"Rated Operational Voltage\" (https:\/\/plc-direct.com\/products\/1sfl551001r8411)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow many poles \/ contacts does it have?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e3\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSource: PLC Direct (third-party listing of ABB official product data), field \"Number of Main Contacts NO\" (https:\/\/plc-direct.com\/products\/1sfl551001r8411)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the rated frequency?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eMain Circuit 50 \/ 60 Hz\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSource: PLC Direct (third-party listing of ABB official product data), field \"Rated Frequency (f)\" (https:\/\/plc-direct.com\/products\/1sfl551001r8411)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the degree of protection?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSource: PLC Direct (third-party listing of ABB official product data), field \"Degree of Protection\" (https:\/\/plc-direct.com\/products\/1sfl551001r8411)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the power rating?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eat Rated Operating Conditions per Pole 18 W\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSource: PLC Direct (third-party listing of ABB official product data), field \"Power Loss\" (https:\/\/plc-direct.com\/products\/1sfl551001r8411)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the product weight?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e5.4 kg\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSource: PLC Direct (third-party listing of ABB official product data), field \"Product Net Weight\" (https:\/\/plc-direct.com\/products\/1sfl551001r8411)\u003c\/em\u003e\u003c\/p\u003e\n\u003c!-- \u003c!-- \/ABB-PLCDIRECT-DATA-BLOCK --\u003e --\u0026gt;","brand":"ABB","offers":[{"title":"New","offer_id":46128754688253,"sku":"1SFL551001R8411","price":400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/ToTVtRTIkBwaxuNarcXoOnFEgu23Qus0es7b4kzDgZRZF5RdxhRdOmFzHJPR_2aabb5c7-770a-4a80-a606-dd81a0fc9eb9.jpg?v=1742347373","url":"https:\/\/shly-plc.com\/products\/abb-a300-30-11-84-1sfl551001r8411-contactor","provider":"SHLY-PLC","version":"1.0","type":"link"}