{"product_id":"abb-a145-30-11-84-1sfl471001r8411-contactor","title":"ABB A145-30-11-84 1SFL471001R8411 Contactor","description":"\u003cp\u003e\u003cstrong\u003eABB product — A145-30-11-84\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- \u003c!-- ABB-PIS-OFFICIAL-DATA-BLOCK --\u003e --\u0026gt;\n\u003ch2\u003eProduct identification\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModel: A145-30-11-84\u003c\/li\u003e\n\u003cli\u003eGlobal material number: 1SFL471001R8411\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSource: ABB Product Information System (PIS) - official ABB product data\u003c\/p\u003e\n\u003cp\u003eEvidence URL: \u003ca href=\"https:\/\/www.abb.com\/global\/en\/products\/1sfl471001r8411\"\u003ehttps:\/\/www.abb.com\/global\/en\/products\/1sfl471001r8411\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003cp\u003eSource: ABB Product Information System (PIS) - official ABB product data — https:\/\/www.abb.com\/global\/en\/products\/1sfl471001r8411\u003c\/p\u003e\n\u003ch3\u003eOrdering\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum Order Quantity\u003c\/th\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCustoms Tariff Number\u003c\/th\u003e\n\u003ctd\u003e85364900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReplacement Product ID (NEW)\u003c\/th\u003e\n\u003ctd\u003e1SFL447002R1311\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Net Width\u003c\/th\u003e\n\u003ctd\u003e111.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Net Depth \/ Length\u003c\/th\u003e\n\u003ctd\u003e160 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Net Height\u003c\/th\u003e\n\u003ctd\u003e196 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Net Weight\u003c\/th\u003e\n\u003ctd\u003e2.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimension Diagram\u003c\/th\u003e\n\u003ctd\u003e53540923-7.PDF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eTechnical\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Main Contacts NO\u003c\/th\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Main Contacts NC\u003c\/th\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Auxiliary Contacts NO\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Auxiliary Contacts NC\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of Poles\u003c\/th\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Operational Voltage\u003c\/th\u003e\n\u003ctd\u003eMain Circuit 690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Frequency (f)\u003c\/th\u003e\n\u003ctd\u003eMain Circuit 50 \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConventional Free-air Thermal Current (Ith)\u003c\/th\u003e\n\u003ctd\u003eacc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 250 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Operational Current AC-1 (Ie)\u003c\/th\u003e\n\u003ctd\u003e(1000 V) 40 °C 180 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Operational Current AC-3 (Ie)\u003c\/th\u003e\n\u003ctd\u003e(415 V) 55 °C 145 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Operational Current DC-1 (Ie)\u003c\/th\u003e\n\u003ctd\u003e(110 V) 2 Poles in Series, 40 °C 250 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Operational Current DC-3 (Ie)\u003c\/th\u003e\n\u003ctd\u003e(110 V) 2 Poles in Series, 40 °C 250 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Operational Current DC-5 (Ie)\u003c\/th\u003e\n\u003ctd\u003e(110 V) 2 Poles in Series, 40 °C 250 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Operational Power AC-3 (Pe)\u003c\/th\u003e\n\u003ctd\u003e(415 V) 75 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Breaking Capacity AC-3\u003c\/th\u003e\n\u003ctd\u003e8 x Ie AC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Making Capacity AC-3\u003c\/th\u003e\n\u003ctd\u003e10 x Ie AC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShort-Circuit Protective Devices\u003c\/th\u003e\n\u003ctd\u003egG Type Fuses 315 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Short-time Withstand Current Low Voltage (Icw)\u003c\/th\u003e\n\u003ctd\u003eat 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1200 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Breaking Capacity\u003c\/th\u003e\n\u003ctd\u003ecos phi=0.45 (cos phi=0.35 for Ie \u0026gt; 100 A) at 440 V 1500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Insulation Voltage (Ui)\u003c\/th\u003e\n\u003ctd\u003eacc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/th\u003e\n\u003ctd\u003eMain Circuit 8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Electrical Switching Frequency\u003c\/th\u003e\n\u003ctd\u003e(AC-1) 300 cycles per hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMechanical Durability\u003c\/th\u003e\n\u003ctd\u003e5 million\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Mechanical Switching Frequency\u003c\/th\u003e\n\u003ctd\u003e3600 cycles per hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCoil Operating Limits\u003c\/th\u003e\n\u003ctd\u003e(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Control Circuit Voltage (Uc)\u003c\/th\u003e\n\u003ctd\u003e50 Hz 110 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCoil Consumption\u003c\/th\u003e\n\u003ctd\u003eAverage Holding Value, from Warm State 12.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Loss\u003c\/th\u003e\n\u003ctd\u003eat Rated Operating Conditions per Pole 5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperate Time\u003c\/th\u003e\n\u003ctd\u003eBetween Coil De-energization and NC Contact Closing 5 ... 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnecting Capacity Main Circuit\u003c\/th\u003e\n\u003ctd\u003eBar 24 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnecting Capacity Auxiliary Circuit\u003c\/th\u003e\n\u003ctd\u003eFlexible with Ferrule 2x 0.75 ... 2.5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnecting Capacity\u003c\/th\u003e\n\u003ctd\u003eBar 24 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of Protection\u003c\/th\u003e\n\u003ctd\u003eacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnecting Terminals (delivered in open position) Main Poles\u003c\/th\u003e\n\u003ctd\u003eFlat type c\/w screws and bolts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTightening Torque\u003c\/th\u003e\n\u003ctd\u003eMain Circuit 18 N·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTerminal Type\u003c\/th\u003e\n\u003ctd\u003eMain Circuit: Bars\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Name\u003c\/th\u003e\n\u003ctd\u003eBlock Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eEnvironmental\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient Air Temperature\u003c\/th\u003e\n\u003ctd\u003eClose to Contactor Fitted with Thermal O\/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Operating Altitude Permissible\u003c\/th\u003e\n\u003ctd\u003eWithout Derating 3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResistance to Shock acc. to IEC 60068-2-27\u003c\/th\u003e\n\u003ctd\u003eShock Direction: A 5 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eContainer Information\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePackage Level 1 Units\u003c\/th\u003e\n\u003ctd\u003ebox 1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePackage Level 1 Width\u003c\/th\u003e\n\u003ctd\u003e178 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePackage Level 1 Depth \/ Length\u003c\/th\u003e\n\u003ctd\u003e232 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePackage Level 1 Height\u003c\/th\u003e\n\u003ctd\u003e167 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePackage Level 1 Gross Weight\u003c\/th\u003e\n\u003ctd\u003e3.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePackage Level 1 EAN\u003c\/th\u003e\n\u003ctd\u003e7320500203293\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the rated supply voltage?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eMain Circuit 690 V\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSource: ABB Product Information System (PIS) - official ABB product data, field \"Rated Operational Voltage\" (https:\/\/www.abb.com\/global\/en\/products\/1sfl471001r8411)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the rated current?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eacc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 250 A\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSource: ABB Product Information System (PIS) - official ABB product data, field \"Conventional Free-air Thermal Current (Ith)\" (https:\/\/www.abb.com\/global\/en\/products\/1sfl471001r8411)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow many poles \/ contacts does it have?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e3\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSource: ABB Product Information System (PIS) - official ABB product data, field \"Number of Main Contacts NO\" (https:\/\/www.abb.com\/global\/en\/products\/1sfl471001r8411)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the rated frequency?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eMain Circuit 50 \/ 60 Hz\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSource: ABB Product Information System (PIS) - official ABB product data, field \"Rated Frequency (f)\" (https:\/\/www.abb.com\/global\/en\/products\/1sfl471001r8411)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the degree of protection?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSource: ABB Product Information System (PIS) - official ABB product data, field \"Degree of Protection\" (https:\/\/www.abb.com\/global\/en\/products\/1sfl471001r8411)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the power rating?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(415 V) 75 kW\u003c\/p\u003e\u003cp\u003e\u003cem\u003eSource: ABB Product Information System (PIS) - official ABB product data, field \"Rated Operational Power AC-3 (Pe)\" (https:\/\/www.abb.com\/global\/en\/products\/1sfl471001r8411)\u003c\/em\u003e\u003c\/p\u003e\n\u003c!-- \u003c!-- \/ABB-PIS-OFFICIAL-DATA-BLOCK --\u003e --\u0026gt;","brand":"ABB","offers":[{"title":"New","offer_id":46128752394493,"sku":"1SFL471001R8411","price":753.64,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/09_03_2023_10_48_28_1SFL471001R8411_ABB_A145_30_11_84_5edb577a-5e8c-469f-b2b0-ab60e65eda33.jpg?v=1742347328","url":"https:\/\/shly-plc.com\/products\/abb-a145-30-11-84-1sfl471001r8411-contactor","provider":"SHLY-PLC","version":"1.0","type":"link"}