{"product_id":"abb-2csk1309ch-industrial-component","title":"ABB 2CSK1309CH","description":"\u003ch3\u003eDC22 C16 A10\u003c\/h3\u003e\u003cp\u003eThe DC22 C16 A10 (2CSK1309CH) is a built-in residual current circuit breaker with overcurrent protection (RCBO) from ABB Chiara flush-mounting wiring accessories, featuring a 16 A current rating, C trip characteristic and a 10 mA residual current sensitivity (Type A). It combines short-circuit and overcurrent protection with earth-leakage (residual current) protection in a single compact device designed for installation inside Chiara wall boxes.\u003c\/p\u003e\u003cp\u003eThis RCBO is configured as a 2-module device with 230 V AC supply and a 1.5 kA breaking capacity per the Chiara RCBO series. The two-pole, Type A device trips for alternating and pulsating DC residual currents, protecting both persons and equipment against indirect and direct contact as well as against fire caused by insulation faults. Its single-module DIN-style construction inside the Chiara enclosure makes it suitable for residential and light-commercial circuits where in-box space is limited.\u003c\/p\u003e\u003cp\u003eThe Chiara built-in RCBO family (DC2x series) shares a common form factor across the Chiara flush-mounting range and is used for circuits requiring combined protection of cables, sockets and connected appliances, including the C25 A30 and C16 A10 members documented on new.abb.com.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable style=\"width:100%;border-collapse:collapse;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"width:38%;text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #e2e2e2;background:#f7f7f7;\"\u003eProduct ID\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #e2e2e2;vertical-align:top;\"\u003e2CSK1309CH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:38%;text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #e2e2e2;background:#f7f7f7;\"\u003eType Designation\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #e2e2e2;vertical-align:top;\"\u003eDC22 C16 A10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:38%;text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #e2e2e2;background:#f7f7f7;\"\u003eSeries\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #e2e2e2;vertical-align:top;\"\u003eChiara (built-in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:38%;text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #e2e2e2;background:#f7f7f7;\"\u003eDevice Type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #e2e2e2;vertical-align:top;\"\u003eRCBO – Residual current circuit breaker with overcurrent protection (MCB+RCD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:38%;text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #e2e2e2;background:#f7f7f7;\"\u003eRated Current (In)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #e2e2e2;vertical-align:top;\"\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:38%;text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #e2e2e2;background:#f7f7f7;\"\u003eTrip Curve\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #e2e2e2;vertical-align:top;\"\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:38%;text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #e2e2e2;background:#f7f7f7;\"\u003eResidual Current Sensitivity (Idn)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #e2e2e2;vertical-align:top;\"\u003e10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:38%;text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #e2e2e2;background:#f7f7f7;\"\u003eRCD Type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #e2e2e2;vertical-align:top;\"\u003eType A (AC and pulsating DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:38%;text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #e2e2e2;background:#f7f7f7;\"\u003eRated Voltage (Un)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #e2e2e2;vertical-align:top;\"\u003e230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:38%;text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #e2e2e2;background:#f7f7f7;\"\u003eNumber of Poles\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #e2e2e2;vertical-align:top;\"\u003e2 poles (2 modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:38%;text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #e2e2e2;background:#f7f7f7;\"\u003eSwitch Frequency\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #e2e2e2;vertical-align:top;\"\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:38%;text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #e2e2e2;background:#f7f7f7;\"\u003eBreaking Capacity\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #e2e2e2;vertical-align:top;\"\u003e1.5 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:38%;text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #e2e2e2;background:#f7f7f7;\"\u003eFront Protection\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #e2e2e2;vertical-align:top;\"\u003eIP4X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:38%;text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #e2e2e2;background:#f7f7f7;\"\u003eElectrical Service Life\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #e2e2e2;vertical-align:top;\"\u003e2,000 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:38%;text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #e2e2e2;background:#f7f7f7;\"\u003eTripping Curve\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #e2e2e2;vertical-align:top;\"\u003e6 In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:38%;text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #e2e2e2;background:#f7f7f7;\"\u003eMinimum Order \/ Packing\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #e2e2e2;vertical-align:top;\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eShipping \u0026amp; Warranty\u003c\/h3\u003e\u003cp\u003eThis unit is shipped as New Surplus — unused, original-condition industrial automation equipment. It is backed by a 12-month limited warranty provided by our company for your risk-free purchase. Please verify part number and technical compatibility before ordering; our technical support team is available to confirm selection. Worldwide export packaging is available and orders are dispatched promptly with reliable logistics and tracking.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"New","offer_id":46126226342141,"sku":"2CSK1309CH","price":176.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/cba2df92a9b51d0e923f901285bbe00f_7aba79e9-bd57-4259-a052-f7103fc92851.png?v=1789041665","url":"https:\/\/shly-plc.com\/products\/abb-2csk1309ch-industrial-component","provider":"SHLY-PLC","version":"1.0","type":"link"}