{"product_id":"abb-2cds252001r0014-safety-module","title":"ABB 2CDS252001R0014","description":"\u003ch3\u003eS202-C1\u003c\/h3\u003e\u003cp\u003eThe S202-C1 (2CDS252001R0014) is a two-pole miniature circuit breaker from the ABB System pro M compact S200 series, with a C trip characteristic and a 1 A rated current. It provides overcurrent and short-circuit protection for cables and appliances in residential and commercial installations, with a 6 kA short-circuit breaking capacity per IEC\/EN 60898-1.\u003c\/p\u003e\u003cp\u003eThe S200 MCB family is ABB System pro M compact and is DIN-rail mountable. The S202-C1 breaks 6 kA at 230\/400 V and is IEC 60898-1 and 60947-2 certified for low-voltage circuit protection. Rated impulse withstand voltage (Uimp) is 6 kV and the frame features ABB standard busbar-ready terminals.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable style=\"width:100%;border-collapse:collapse;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"width:38%;text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #e2e2e2;background:#f7f7f7;\"\u003eProduct ID\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #e2e2e2;vertical-align:top;\"\u003e2CDS252001R0014\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:38%;text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #e2e2e2;background:#f7f7f7;\"\u003eType Designation\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #e2e2e2;vertical-align:top;\"\u003eS202-C1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:38%;text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #e2e2e2;background:#f7f7f7;\"\u003eSeries\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #e2e2e2;vertical-align:top;\"\u003eSystem pro M compact S200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:38%;text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #e2e2e2;background:#f7f7f7;\"\u003eDevice Type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #e2e2e2;vertical-align:top;\"\u003eMiniature circuit breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:38%;text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #e2e2e2;background:#f7f7f7;\"\u003eRated Current (In)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #e2e2e2;vertical-align:top;\"\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:38%;text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #e2e2e2;background:#f7f7f7;\"\u003eTrip Curve\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #e2e2e2;vertical-align:top;\"\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:38%;text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #e2e2e2;background:#f7f7f7;\"\u003eRated Voltage (Un)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #e2e2e2;vertical-align:top;\"\u003e400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:38%;text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #e2e2e2;background:#f7f7f7;\"\u003eNumber of Poles\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #e2e2e2;vertical-align:top;\"\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:38%;text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #e2e2e2;background:#f7f7f7;\"\u003eShort-circuit Breaking Capacity (Icn)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #e2e2e2;vertical-align:top;\"\u003e6 kA (IEC\/EN 60898-1, 230\/400 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:38%;text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #e2e2e2;background:#f7f7f7;\"\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #e2e2e2;vertical-align:top;\"\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:38%;text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #e2e2e2;background:#f7f7f7;\"\u003eStandards\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #e2e2e2;vertical-align:top;\"\u003eIEC\/EN 60898-1, IEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:38%;text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #e2e2e2;background:#f7f7f7;\"\u003eFrequency\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #e2e2e2;vertical-align:top;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:38%;text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #e2e2e2;background:#f7f7f7;\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #e2e2e2;vertical-align:top;\"\u003eDIN rail (35 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:38%;text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #e2e2e2;background:#f7f7f7;\"\u003eDegree of Protection\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #e2e2e2;vertical-align:top;\"\u003eIP40 (housing) \/ IP20 (terminals)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:38%;text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #e2e2e2;background:#f7f7f7;\"\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #e2e2e2;vertical-align:top;\"\u003e-25 °C ... +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:38%;text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #e2e2e2;background:#f7f7f7;\"\u003eDimensions\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #e2e2e2;vertical-align:top;\"\u003e2 modules (W×D×H 35×70×88 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:38%;text-align:left;vertical-align:top;padding:6px 10px;border:1px solid #e2e2e2;background:#f7f7f7;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #e2e2e2;vertical-align:top;\"\u003e0.28 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eShipping \u0026amp; Warranty\u003c\/h3\u003e\u003cp\u003eThis unit is shipped as New Surplus — unused, original-condition industrial automation equipment. It is backed by a 12-month limited warranty provided by our company for your risk-free purchase. Please verify part number and technical compatibility before ordering; our technical support team is available to confirm selection. Worldwide export packaging is available and orders are dispatched promptly with reliable logistics and tracking.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"New","offer_id":46126014529789,"sku":"2CDS252001R0014","price":33.11,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/9PAA00000081818_400x400_5d1aacdf-69d8-412c-8c88-f8e468d7e1e6.png?v=1788762325","url":"https:\/\/shly-plc.com\/products\/abb-2cds252001r0014-safety-module","provider":"SHLY-PLC","version":"1.0","type":"link"}