{"product_id":"abb-1sda068221r1-moulded-case-circuit-breaker","title":"ABB 1SDA068221R1 Moulded Case Circuit Breaker","description":"\n\u003cstyle\u003e\n.desc-model-title{display:block;border:none;outline:none;text-transform:none;padding:0;background:none;margin:inherit;}\n.desc-model-title {font-size:30px;margin:6px 0 4px;letter-spacing:.5px;}\n:root{--abb-red:#E2231A;--abb-dark:#1A1A1A;--ink:#222;--muted:#5f6368;--line:#e3e5e8;--bg:#f5f6f8;--card:#fff;--accent-soft:#fdeceb;--blue:#4a6cf7;--info-bg:#eef3ff;--info-line:#4a6cf7;--info-ink:#22345e;}*{box-sizing:border-box;}body{margin:0;font-family:\"Segoe UI\",Arial,Helvetica,sans-serif;color:var(--ink);background:var(--bg);line-height:1.55;font-size:15px;}.wrap{max-width:1080px;margin:0 auto;padding:0 24px 64px;}header.hero{background:linear-gradient(120deg,#1a1a1a,#333);color:#fff;padding:38px 0 30px;margin-bottom:24px;border-bottom:6px solid var(--abb-red);}header.hero .wrap{padding-bottom:0;}.brand{display:flex;align-items:center;gap:12px;margin-bottom:18px;}.brand .logo{background:var(--abb-red);color:#fff;font-weight:800;letter-spacing:1px;padding:4px 10px;border-radius:3px;font-size:20px;}.brand .fam{font-size:14px;color:#cfcfcf;text-transform:uppercase;letter-spacing:2px;}h1{font-size:30px;margin:6px 0 4px;letter-spacing:.5px;}.subtitle{color:#bdbdbd;font-size:15px;margin:0 0 18px;}.chips{display:flex;flex-wrap:wrap;gap:8px;}.chip{background:rgba(255,255,255,.1);border:1px solid rgba(255,255,255,.25);border-radius:20px;padding:4px 14px;font-size:13px;color:#f1f1f1;}.chip b{color:#fff;}section{background:var(--card);border:1px solid var(--line);border-radius:10px;padding:22px 26px;margin:18px 0;}h2{font-size:19px;margin:0 0 14px;padding-bottom:10px;border-bottom:2px solid var(--abb-red);display:inline-block;}h3{font-size:15px;margin:18px 0 8px;color:var(--abb-dark);}table{border-collapse:collapse;width:100%;margin:8px 0 6px;font-size:14px;}th,td{text-align:left;padding:9px 12px;border-bottom:1px solid var(--line);vertical-align:top;}th{background:#f0f1f3;font-weight:600;color:#333;}tr:last-child td,tr:last-child th{border-bottom:none;}td.val{font-weight:500;}.grid2{display:grid;grid-template-columns:1fr 1fr;gap:0 28px;}.cards{display:grid;grid-template-columns:repeat(4,1fr);gap:12px;margin:6px 0 4px;}.stat{border:1px solid var(--line);border-radius:8px;padding:14px;background:#fafbfc;}.stat .k{font-size:12px;color:var(--muted);text-transform:uppercase;letter-spacing:.6px;margin-bottom:6px;}.stat .v{font-size:20px;font-weight:700;color:var(--abb-dark);}.stat .v small{font-size:12px;font-weight:500;color:var(--muted);}.infonote{background:var(--info-bg);border-left:4px solid var(--info-line);padding:12px 16px;border-radius:0 6px 6px 0;font-size:14px;color:var(--info-ink);margin:0;}.infonote b{color:#16264d;}footer{text-align:center;color:var(--muted);font-size:12px;margin-top:26px;}@media (max-width:820px){.grid2{grid-template-columns:1fr;}.cards{grid-template-columns:repeat(2,1fr);}}\u003c\/style\u003e\n\u003cheader class=\"hero\"\u003e\u003cdiv class=\"wrap\"\u003e\n\u003cdiv class=\"brand\"\u003e\n\u003cspan class=\"logo\"\u003eABB\u003c\/span\u003e\u003cspan class=\"fam\"\u003eSACE Tmax XT\u003c\/span\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"desc-model-title\"\u003e1SDA068221R1\u003c\/h2\u003e\n\u003cp class=\"subtitle\"\u003e3-Pole Moulded Case Circuit Breaker — 50 kA Breaking Capacity at 415V AC\u003c\/p\u003e\n\u003cdiv class=\"chips\"\u003e\n\u003cspan class=\"chip\"\u003e\u003cb\u003e250 A\u003c\/b\u003e Rated\u003c\/span\u003e\n\u003cspan class=\"chip\"\u003e\u003cb\u003e3P\u003c\/b\u003e Configuration\u003c\/span\u003e\n\u003cspan class=\"chip\"\u003e\u003cb\u003e50 kA\u003c\/b\u003e @ 415V\u003c\/span\u003e\n\u003cspan class=\"chip\"\u003e\u003cb\u003eTMD\u003c\/b\u003e Release\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/header\u003e\n\u003cdiv class=\"wrap\"\u003e\n\u003csection\u003e\u003ch2\u003eKey Ratings at a Glance\u003c\/h2\u003e\n\u003cdiv class=\"cards\"\u003e\n\u003cdiv class=\"stat\"\u003e\n\u003cdiv class=\"k\"\u003eRated Current\u003c\/div\u003e\n\u003cdiv class=\"v\"\u003e250 \u003csmall\u003eA\u003c\/small\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"stat\"\u003e\n\u003cdiv class=\"k\"\u003eBreaking Capacity\u003c\/div\u003e\n\u003cdiv class=\"v\"\u003e50 \u003csmall\u003ekA @ 415V\u003c\/small\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"stat\"\u003e\n\u003cdiv class=\"k\"\u003ePoles\u003c\/div\u003e\n\u003cdiv class=\"v\"\u003e3\u003csmall\u003eP\u003c\/small\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"stat\"\u003e\n\u003cdiv class=\"k\"\u003ePerformance Level\u003c\/div\u003e\n\u003cdiv class=\"v\"\u003eS\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\n\u003csection\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd class=\"val\"\u003eMoulded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd class=\"val\"\u003eXT3S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Unit\u003c\/td\u003e\n\u003ctd class=\"val\"\u003eTMD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd class=\"val\"\u003e250 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd class=\"val\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage (Ur)\u003c\/td\u003e\n\u003ctd class=\"val\"\u003e690 V AC \/ 500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd class=\"val\"\u003e800 V (XT1\/XT2) \/ 1000 V (XT3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Impulse Withstand (Uimp)\u003c\/td\u003e\n\u003ctd class=\"val\"\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIcs @ 220V AC\u003c\/td\u003e\n\u003ctd class=\"val\"\u003e100 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIcs @ 380-415V AC\u003c\/td\u003e\n\u003ctd class=\"val\"\u003e50 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIcs @ 440V AC\u003c\/td\u003e\n\u003ctd class=\"val\"\u003e25 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIcs @ 690V AC\u003c\/td\u003e\n\u003ctd class=\"val\"\u003e7 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd class=\"val\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd class=\"val\"\u003eFront \/ Bolt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W×D×H)\u003c\/td\u003e\n\u003ctd class=\"val\"\u003e114 × 103 × 205 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"val\"\u003e3.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd class=\"val\"\u003eDIN Rail \/ Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd class=\"val\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd class=\"val\"\u003eIEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/section\u003e\n\u003csection\u003e\u003ch2\u003eApplications \u0026amp; Features\u003c\/h2\u003e\n\u003cdiv class=\"grid2\"\u003e\n\u003cdiv\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial power distribution boards and switchgear\u003c\/li\u003e\n\u003cli\u003eCommercial building electrical distribution systems\u003c\/li\u003e\n\u003cli\u003eMotor protection and control circuits\u003c\/li\u003e\n\u003cli\u003eGenerator set protection\u003c\/li\u003e\n\u003cli\u003eUPS and battery backup systems\u003c\/li\u003e\n\u003cli\u003eInfrastructure and utility installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompact design: only 114 mm width for 3P\u003c\/li\u003e\n\u003cli\u003eHigh breaking capacity: 50 kA at 415V AC\u003c\/li\u003e\n\u003cli\u003eThermo-magnetic (TMD) trip unit for reliable overload and short-circuit protection\u003c\/li\u003e\n\u003cli\u003eVisually clear rotary handle with ON\/OFF indication\u003c\/li\u003e\n\u003cli\u003eLockable handle for safety (padlock accessory available)\u003c\/li\u003e\n\u003cli\u003eFull selectivity coordination with upstream\/downstream devices\u003c\/li\u003e\n\u003cli\u003eExpandable with auxiliary contacts, shunt trips, and undervoltage releases\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/section\u003e\n\u003csection\u003e\u003ch2\u003eCompliance \u0026amp; Approvals\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE Marking\u003c\/td\u003e\n\u003ctd class=\"val\"\u003eYes — Low Voltage Directive 2014\/35\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS\u003c\/td\u003e\n\u003ctd class=\"val\"\u003eCompliant — Directive 2011\/65\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL\/cUL\u003c\/td\u003e\n\u003ctd class=\"val\"\u003eListed (applicable standards)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIEC Standards\u003c\/td\u003e\n\u003ctd class=\"val\"\u003eIEC\/EN 60947 series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarine Approvals\u003c\/td\u003e\n\u003ctd class=\"val\"\u003eABS, DNV, LR, BV, RINA (where applicable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\n\u003c\/section\u003e\n\n\u003c\/div\u003e\n\u003cdiv class=\"faq-section\" style=\"margin-top:30px;padding:20px;background:#f8f9fa;border-radius:8px;\"\u003e\n\u003ch3 style=\"font-size:18px;margin-bottom:12px;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdiv class=\"faq-item\" style=\"margin-bottom:12px;\"\u003e\n\u003cstrong style=\"color:#333;\"\u003eQ: What is the warranty for ABB XT3S 250A TMD 3P MCCB?\u003c\/strong\u003e\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12-month seller warranty provided by SHLY-PLC. See our \u003ca href=\"\/pages\/return-policy\"\u003eReturn Policy\u003c\/a\u003e for coverage and claims.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\" style=\"margin-bottom:12px;\"\u003e\n\u003cstrong style=\"color:#333;\"\u003eQ: How fast can you ship XT3S 250A TMD 3P MCCB?\u003c\/strong\u003e\u003cp style=\"margin:4px 0 0;\"\u003eA: Orders are processed within 2-4 business days after payment confirmation. Standard delivery: 5-8 business days to the United States and Canada. Express available (2–4 business days).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"faq-item\" style=\"margin-bottom:12px;\"\u003e\n\u003cstrong style=\"color:#333;\"\u003eQ: Is XT3S 250A TMD 3P MCCB compatible with ABB systems?\u003c\/strong\u003e\u003cp style=\"margin:4px 0 0;\"\u003eA: Sold by SHLY-PLC, an independent distributor. New surplus stock; condition and compatibility confirmed on request.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eModel Specifications\u003c\/h3\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;background:#f2f2f2;font-weight:bold;\"\u003econverted_model\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1SDA068221R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;background:#f2f2f2;font-weight:bold;\"\u003efamily\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eSACE Tmax XT3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;background:#f2f2f2;font-weight:bold;\"\u003eextended_product_type\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eXT3S 250 TMD 250-2500 3p F F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;background:#f2f2f2;font-weight:bold;\"\u003eframe_current_Iu_A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;background:#f2f2f2;font-weight:bold;\"\u003erated_current_In_A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;background:#f2f2f2;font-weight:bold;\"\u003enumber_of_poles\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;background:#f2f2f2;font-weight:bold;\"\u003etrip_unit\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eTMD (thermal-magnetic, fixed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;background:#f2f2f2;font-weight:bold;\"\u003emagnetic_trip_setting_Ii_A\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e2500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;background:#f2f2f2;font-weight:bold;\"\u003eIcu_at_415V_AC_kA\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;background:#f2f2f2;font-weight:bold;\"\u003eIcs_percent_of_Icu\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e50%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;background:#f2f2f2;font-weight:bold;\"\u003emounting\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003eFixed, front terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;background:#f2f2f2;font-weight:bold;\"\u003eweight_kg\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd;padding:8px;\"\u003e1.632\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp style=\"font-size:12px;color:#666;\"\u003eSource: \u003ca href=\"https:\/\/www.kempstoncontrols.co.uk\/1SDA068221R1\/ABB\/sku\/696400\"\u003edatasheet \/ product page\u003c\/a\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"New","offer_id":46127565046013,"sku":"1SDA068221R1","price":354.28,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/product_8844104171773.jpg?v=1784974314","url":"https:\/\/shly-plc.com\/products\/abb-1sda068221r1-moulded-case-circuit-breaker","provider":"SHLY-PLC","version":"1.0","type":"link"}