{"product_id":"abb-1sda067579r1-circuit-breaker","title":"ABB 1SDA067579R1","description":"\u003ch3 style=\"margin: 22px 0 10px;\"\u003eABB Tmax XT2S 160 Molded Case Circuit Breaker\u003c\/h3\u003e\n\u003cp\u003eThe XT2S 160 TMA 100-1000 is a four-pole molded case circuit breaker (MCCB) from the ABB SACE Tmax XT family. It features a TMA thermomagnetic trip unit set to 100 A continuous current with an adjustable magnetic threshold of 500–1000 A, providing both overload and short-circuit protection for distribution, motor and feeder circuits.\u003c\/p\u003e\n\u003cp\u003eThe frame current (Iu) is 160 A and the breaking capacity reaches 50 kA at 400 V (85 kA at 230 V), making the XT2S suitable for demanding industrial and commercial switchboards in a compact footprint. Rated insulation voltage is 1000 V with 8 kV impulse withstand.\u003c\/p\u003e\n\u003cp\u003eThe fixed four-pole breaker is built and tested according to IEC 60947-2 and integrates with the full Tmax XT accessory range (auxiliary contacts, shunt releases, motor operators and interlocks) for panel builders and system integrators.\u003c\/p\u003e\n\u003ch3 style=\"margin: 22px 0 10px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;margin:12px 0 20px;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #e5e7eb;padding:8px 12px;background:#f9fafb;font-weight:600;width:38%;\"\u003eProduct ID\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #e5e7eb;padding:8px 12px;\"\u003e1SDA067579R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #e5e7eb;padding:8px 12px;background:#f9fafb;font-weight:600;width:38%;\"\u003eProduct Series\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #e5e7eb;padding:8px 12px;\"\u003eSACE Tmax XT2 (XT2S)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #e5e7eb;padding:8px 12px;background:#f9fafb;font-weight:600;width:38%;\"\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #e5e7eb;padding:8px 12px;\"\u003e4 (fixed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #e5e7eb;padding:8px 12px;background:#f9fafb;font-weight:600;width:38%;\"\u003eFrame Current (Iu)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #e5e7eb;padding:8px 12px;\"\u003e160 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #e5e7eb;padding:8px 12px;background:#f9fafb;font-weight:600;width:38%;\"\u003eTrip Unit\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #e5e7eb;padding:8px 12px;\"\u003eTMA thermomagnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #e5e7eb;padding:8px 12px;background:#f9fafb;font-weight:600;width:38%;\"\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #e5e7eb;padding:8px 12px;\"\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #e5e7eb;padding:8px 12px;background:#f9fafb;font-weight:600;width:38%;\"\u003eMagnetic Threshold (I3)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #e5e7eb;padding:8px 12px;\"\u003e500–1000 A, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #e5e7eb;padding:8px 12px;background:#f9fafb;font-weight:600;width:38%;\"\u003eBreaking Capacity (Icu)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #e5e7eb;padding:8px 12px;\"\u003e50 kA at 400 V; 85 kA at 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #e5e7eb;padding:8px 12px;background:#f9fafb;font-weight:600;width:38%;\"\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #e5e7eb;padding:8px 12px;\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #e5e7eb;padding:8px 12px;background:#f9fafb;font-weight:600;width:38%;\"\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #e5e7eb;padding:8px 12px;\"\u003e8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #e5e7eb;padding:8px 12px;background:#f9fafb;font-weight:600;width:38%;\"\u003eElectrical Endurance\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #e5e7eb;padding:8px 12px;\"\u003e8,000 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #e5e7eb;padding:8px 12px;background:#f9fafb;font-weight:600;width:38%;\"\u003eMechanical Endurance\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #e5e7eb;padding:8px 12px;\"\u003e25,000 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #e5e7eb;padding:8px 12px;background:#f9fafb;font-weight:600;width:38%;\"\u003eStandards\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #e5e7eb;padding:8px 12px;\"\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #e5e7eb;padding:8px 12px;background:#f9fafb;font-weight:600;width:38%;\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #e5e7eb;padding:8px 12px;\"\u003eApprox. 1.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp style=\"margin-top:18px;\"\u003e\u003cb\u003eShipping \u0026amp; Warranty:\u003c\/b\u003e Fast order processing with worldwide delivery available. This item is sold as \u003cb\u003eNew Surplus\u003c\/b\u003e and backed by our \u003cb\u003e12-month warranty\u003c\/b\u003e, which covers quality-related replacement or refund. Contact our team for compatibility checks, bulk pricing, or spare-parts sourcing support.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"New","offer_id":46127551119613,"sku":"1SDA067579R1","price":229.63,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/9IBA255267_400x400_187dbc39-db4a-4018-9a47-6fbd402af48d.png?v=1788762466","url":"https:\/\/shly-plc.com\/products\/abb-1sda067579r1-circuit-breaker","provider":"SHLY-PLC","version":"1.0","type":"link"}