{"product_id":"abb-1sap450300r0001-ai523-xc-analog-input-module","title":"ABB 1SAP450300R0001 AI523-XC Analog Input Module","description":"\u003c!-- ABB-OFFICIAL-DATA-BLOCK --\u003e\n\u003cp\u003e\u003cstrong\u003eProduct identification\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e AI523-XC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChina order number:\u003c\/strong\u003e 3ABD00029584\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlobal material number:\u003c\/strong\u003e 1SAP450300R0001\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct description\u003c\/h3\u003e\u003cp\u003eAnalog input module. 16 AI: U, I, RTD, DI (AI523-XC)\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eSource: \u003ca href=\"https:\/\/www.abb.com\/global\/en\/products\/1sap450300r0001\" rel=\"nofollow\"\u003eABB official product page\u003c\/a\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cem\u003eSource: \u003ca href=\"https:\/\/library.e.abb.com\/public\/b66eb51cd5dc45cdb723baeabff8088a\/3ADR010029%2C%2015%2C%20en-US%2C%20AI523_Data_Sheet.pdf\" rel=\"nofollow\"\u003eABB Data sheet 3ADR010029\u003c\/a\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical data\u003c\/h4\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRated value\u003c\/th\u003e\n\u003ctd\u003e24 V DC \u003csmall\u003e(3.1 Technical data of the module)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. ripple\u003c\/th\u003e\n\u003ctd\u003e5 % \u003csmall\u003e(3.1 Technical data of the module)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection against reversed voltage\u003c\/th\u003e\n\u003ctd\u003eYes \u003csmall\u003e(3.1 Technical data of the module)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated protection fuse on UP\u003c\/th\u003e\n\u003ctd\u003e10 A fast \u003csmall\u003e(3.1 Technical data of the module)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGalvanic isolation\u003c\/th\u003e\n\u003ctd\u003eYes, per module \u003csmall\u003e(3.1 Technical data of the module)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrom 24 V DC power supply at the terminals UP\/L+ and ZP\/M of the CPU\/communication interface module\u003c\/th\u003e\n\u003ctd\u003eCa. 2 m A \u003csmall\u003e(3.1 Technical data of the module)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrom UP at normal operation \/ with outputs\u003c\/th\u003e\n\u003ctd\u003e0.15 A + output loads \u003csmall\u003e(3.1 Technical data of the module)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInrush current from UP (at power up)\u003c\/th\u003e\n\u003ctd\u003e0.050 A2s \u003csmall\u003e(3.1 Technical data of the module)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. length of analog cables, conductor cross section \u0026gt; 0.14 mm2\u003c\/th\u003e\n\u003ctd\u003e100 m \u003csmall\u003e(3.1 Technical data of the module)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e300 g \u003csmall\u003e(3.1 Technical data of the module)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting position\u003c\/th\u003e\n\u003ctd\u003eHorizontal mounting or Vertical mounting with derating (output load reduced to 50 % at +40 °C per group) \u003csmall\u003e(3.1 Technical data of the module)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling\u003c\/th\u003e\n\u003ctd\u003eThe natural convection cooling must not be hindered by cable ducts or other parts in the control cabinet. \u003csmall\u003e(3.1 Technical data of the module)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInternal power supply\u003c\/th\u003e\n\u003ctd\u003eVia the I\/O bus interface (I\/O bus) \u003csmall\u003e(3.1 Technical data of the module)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExternal power supply\u003c\/th\u003e\n\u003ctd\u003eVia the terminals ZP and UP (process voltage 24 V DC) \u003csmall\u003e(3.1 Technical data of the module)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eMechanical data\u003c\/h4\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eHorizontal\/Vertical \u003csmall\u003e(4.5 Mechanical data)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWiring method\u003c\/th\u003e\n\u003ctd\u003eSpring\/screw terminals \u003csmall\u003e(4.5 Mechanical data)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003ePLC system: IP 20 ● With all modules or option boards plugged in. ● With all terminals plugged in. ● With all covers closed. \u003csmall\u003e(4.5 Mechanical data)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing\u003c\/th\u003e\n\u003ctd\u003eClassification V-2 according to UL 94 \u003csmall\u003e(4.5 Mechanical data)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration resistance (sinusoidal) acc. to IEC 60068-2-6\u003c\/th\u003e\n\u003ctd\u003eAll three axes 2 Hz ... 8.4 Hz, 3.5 mm peak, 8.4 Hz ... 150 Hz, 1 g \u003csmall\u003e(4.5 Mechanical data)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShock test acc. to IEC 60068-2-27\u003c\/th\u003e\n\u003ctd\u003eAll three axes 15 g, 11 ms, half-sinusoidal \u003csmall\u003e(4.5 Mechanical data)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting Rail Top Hat according to IEC 60715\u003c\/th\u003e\n\u003ctd\u003e35 mm, depth 7.5 mm or 15 mm \u003csmall\u003e(4.5 Mechanical data)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting with screws\u003c\/th\u003e\n\u003ctd\u003eM4 \u003csmall\u003e(4.5 Mechanical data)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eEnvironmental conditions\u003c\/h4\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e24 V (-15 %, +20 %) \u003csmall\u003e(5.1 Environmental conditions)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection against reverse polarity\u003c\/th\u003e\n\u003ctd\u003eYes \u003csmall\u003e(5.1 Environmental conditions)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e100 V ... 240 V (-15 %, +10 %) \u003csmall\u003e(5.1 Environmental conditions)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50\/60 Hz (-6 %, +4 %) \u003csmall\u003e(5.1 Environmental conditions)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC supply\u003c\/th\u003e\n\u003ctd\u003eInterruption \u0026lt; 10 ms, time between 2 interruptions \u0026gt; 1 s, PS2 \u003csmall\u003e(5.1 Environmental conditions)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAC supply\u003c\/th\u003e\n\u003ctd\u003eInterruption \u0026lt; 0.5 periods, time between 2 interruptions \u0026gt; 1 s \u003csmall\u003e(5.1 Environmental conditions)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating\u003c\/th\u003e\n\u003ctd\u003e-40 °C ... +70 °C -40 °C ... 0 °C: Due to the LCD technology, the display might respond very slowly. -40 °C ... +40 °C: Vertical mounting of modules possible, output load limited to 50 % per group +60 °C ... +70 °C with the following deratings: ● System is limited to maximum 2 communication modules per terminal base... \u003csmall\u003e(5.1 Environmental conditions)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage \/ Transport\u003c\/th\u003e\n\u003ctd\u003e-40 °C ... +85 °C \u003csmall\u003e(5.1 Environmental conditions)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003eOperating \/ Storage: 100 % r. H. with condensation \u003csmall\u003e(5.1 Environmental conditions)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAir pressure\u003c\/th\u003e\n\u003ctd\u003eOperating: -1000 m .... 5000 m (1080 h Pa ... 620 h Pa) \u0026gt; 2000 m (\u0026lt; 795 h Pa): ● Maximum operating temperature must be reducted by 10 K for each 1000 m exceeding 2000 m. ● I\/O module relay contacts must be operated with 24 V nominal only. \u003csmall\u003e(5.1 Environmental conditions)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch4\u003eAdditional data\u003c\/h4\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRadiated emission according to IEC 61000-6-4 CISPR11, class A\u003c\/th\u003e\n\u003ctd\u003eYes \u003csmall\u003e(4.4 Electromagnetic compatibility)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConducted emission according to IEC 61000-6-4 CISPR11, class A\u003c\/th\u003e\n\u003ctd\u003eYes \u003csmall\u003e(4.4 Electromagnetic compatibility)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrostatic discharge (ESD) according to IEC 61000-4-2, criterion B\u003c\/th\u003e\n\u003ctd\u003eAir discharge: 8 kV Contact discharge: 6 kV \u003csmall\u003e(4.4 Electromagnetic compatibility)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFast transient interference voltages (burst) according to IEC 61000-4-4, criterion B\u003c\/th\u003e\n\u003ctd\u003ePower supply (DC): 2 kV Digital inputs\/outputs (24 V DC): 1 kV Digital inputs\/outputs (240 V AC): 2 kV Analog inputs\/outputs: 1 kV Communication lines shielded: 1 kV \u003csmall\u003e(4.4 Electromagnetic compatibility)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHigh energy transient interference voltages (surge) according to IEC 61000-4-5, criterion B\u003c\/th\u003e\n\u003ctd\u003ePower supply (DC): - Line to ground: 1 kV - Line to line: 0,5 kV Digital inputs\/outputs\/relay: (24 V DC): - Line to ground: 1 kV (AC): - Line to ground: 2 kV - Line to line: 1 kV Analog inputs\/outputs: - Line to ground: 1 kV Communication lines: - Line to ground: 1 kV \u003csmall\u003e(4.4 Electromagnetic compatibility)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInfluence of radiated disturbances IEC 61000-4-3, criterion A\u003c\/th\u003e\n\u003ctd\u003eTest field strength: 10 V\/m \u003csmall\u003e(4.4 Electromagnetic compatibility)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInfluence of line-conducted interferences IEC 61000-4-6, criterion A\u003c\/th\u003e\n\u003ctd\u003eTest voltage: 10 V \u003csmall\u003e(4.4 Electromagnetic compatibility)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower frequency magnetic fields IEC 61000-4-8, criterion A\u003c\/th\u003e\n\u003ctd\u003e30 A\/m 50 Hz 30 A\/m 60 Hz \u003csmall\u003e(4.4 Electromagnetic compatibility)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFast transient interference voltages (burst) according to IEC 61000-4-4, criterion B\u003c\/th\u003e\n\u003ctd\u003ePower supply (DC): 4 kV Digital inputs\/outputs (24 V DC): 2 kV Digital inputs\/outputs (240 V AC): 4 kV Analog inputs\/outputs: 2 kV Communication lines shielded: 2 kV \u003csmall\u003e(5.4 Electromagnetic compatibility)\u003c\/small\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the AI523-XC?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eA: Analog input module. 16 AI: U, I, RTD, DI (AI523-XC) \u003cem\u003e(ABB official product page)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the degree of protection?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eA: PLC system: IP 20 ● With all modules or option boards plugged in. ● With all terminals plugged in. ● With all covers closed. \u003cem\u003e(Datasheet 3ADR010029, 4.5 Mechanical data)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How is it mounted?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eA: Horizontal mounting or Vertical mounting with derating (output load reduced to 50 % at +40 °C per group) \u003cem\u003e(Datasheet 3ADR010029, 3.1 Technical data of the module)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the housing material?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eA: Classification V-2 according to UL 94 \u003cem\u003e(Datasheet 3ADR010029, 4.5 Mechanical data)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What vibration and shock ratings does it meet?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eA: All three axes 2 Hz ... 8.4 Hz, 3.5 mm peak, 8.4 Hz ... 150 Hz, 1 g \u003cem\u003e(Datasheet 3ADR010029, 4.5 Mechanical data)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the weight?\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eA: 300 g \u003cem\u003e(Datasheet 3ADR010029, 3.1 Technical data of the module)\u003c\/em\u003e\u003c\/p\u003e\n\u003c!-- \/ABB-OFFICIAL-DATA-BLOCK --\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":71249135468797,"sku":"1SAP450300R0001","price":420.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/plc_1SAP450300R0001_800_93b77392-f01a-4511-acc2-dd60bac838ff.jpg?v=1792741425","url":"https:\/\/shly-plc.com\/products\/abb-1sap450300r0001-ai523-xc-analog-input-module","provider":"SHLY-PLC","version":"1.0","type":"link"}