{"product_id":"8bvp0880hc00-004-1","title":"B\u0026R 8BVP0880HC00-004-1 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Motion control \u0026gt; ACOPOSmulti \u0026gt; Power supply modules \u0026gt; Cold plate or feed-through mounting\u003c\/p\u003e\n\u003cp\u003eExtensive input voltage range Capable of regeneration Integrated connection for temperature sensors 2 slots for ACOPOSmulti plug-in modules ACOPOSmulti power supply module, 88 A, AS, cold plate or pass-through mounting.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupport\u003c\/li\u003e\n\u003cli\u003eDynamic node allocation (DNA) = Yes\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eUL = cULus E225616 Power conversion equipment\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0xA6A1\u003c\/li\u003e\n\u003cli\u003eCooling and mounting type = Cold plate or pass-through mounting\u003c\/li\u003e\n\u003cli\u003eSlots for plug-in modules = 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMains connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMax. chargeable DC bus capacitance depending on mains voltage\u003c\/li\u003e\n\u003cli\u003e230 VAC = 34.8 mF\u003c\/li\u003e\n\u003cli\u003e400 VAC = 11.5 mF\u003c\/li\u003e\n\u003cli\u003e480 VAC = 8 mF\u003c\/li\u003e\n\u003cli\u003eVariant\u003c\/li\u003e\n\u003cli\u003eL1, L2, L3, PE = M8 threaded bolts\u003c\/li\u003e\n\u003cli\u003eShield connection = Yes\u003c\/li\u003e\n\u003cli\u003eConnection cross section range\u003c\/li\u003e\n\u003cli\u003eFlexible and fine-stranded wires = ---\u003c\/li\u003e\n\u003cli\u003eNetwork configurations = TT, TN-S, TN-C-S\u003c\/li\u003e\n\u003cli\u003eMains input voltage = 3x 220 to 3x 480 VAC ±10%\u003c\/li\u003e\n\u003cli\u003eFrequency = 50 \/ 60 Hz ±4%\u003c\/li\u003e\n\u003cli\u003eTotal harmonic distortion current (THDi) = \u0026lt;0.2%\u003c\/li\u003e\n\u003cli\u003eTotal harmonic distortion voltage (THDu) = \u0026lt;1%\u003c\/li\u003e\n\u003cli\u003eInstalled load = Max. 62 kW\u003c\/li\u003e\n\u003cli\u003eInrush current at 400 VAC = Max. 133 A\u003c\/li\u003e\n\u003cli\u003eSwitch-on interval = \u0026gt;300 s\u003c\/li\u003e\n\u003cli\u003eNominal switching frequency = 5 kHz\u003c\/li\u003e\n\u003cli\u003ePossible switching frequencies = 5 \/ 10 kHz\u003c\/li\u003e\n\u003cli\u003eIntegrated line filter per EN 61800-3, category C3 = No\u003c\/li\u003e\n\u003cli\u003eIntegrated regeneration choke = No\u003c\/li\u003e\n\u003cli\u003eRegenerative = Yes\u003c\/li\u003e\n\u003cli\u003ePower factor correction (PFC) = Yes\u003c\/li\u003e\n\u003cli\u003eLine fuse = Max. 264 A (gG fuses per IEC 60269-1 or Class CC, J, T) Max. 220 A (circuit breaker per EN 60947-2 or UL 489)\u003c\/li\u003e\n\u003cli\u003eTerminal cable cross section dimension of shield connection = 32 to 50 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDC bus connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage\u003c\/li\u003e\n\u003cli\u003eNominal = 750 VDC\u003c\/li\u003e\n\u003cli\u003eReduction of continuous power depending on mains input voltage\u003c\/li\u003e\n\u003cli\u003eMains input voltage \u0026lt;3x 400 VAC = 150 W\/V * (400 V - Mains input voltage)\u003c\/li\u003e\n\u003cli\u003eReduction of continuous power depending on DC bus voltage (U DC )\u003c\/li\u003e\n\u003cli\u003eU DC \u0026lt;750 VDC = 0.08 kW\/V\u003c\/li\u003e\n\u003cli\u003eReduction of continuous power depending on switching frequency and mounting type\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz\u003c\/li\u003e\n\u003cli\u003eCold plate mounting = 1.3 kW\/K (starting at 58°C)\u003c\/li\u003e\n\u003cli\u003ePass-through mounting = In preparation\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz\u003c\/li\u003e\n\u003cli\u003eCold plate mounting = 0.95 kW\/K (starting at 27°C)\u003c\/li\u003e\n\u003cli\u003eReduction of continuous power depending on installation elevation\u003c\/li\u003e\n\u003cli\u003eStarting at 500 m above sea level = 6 kW per 1000 m\u003c\/li\u003e\n\u003cli\u003ePower dissipation depending on switching frequency\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz = [0.065*P²+11.4*P+90] W\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz = [0.22*P²+16.1*P+185] W\u003c\/li\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eOverload protection = Yes\u003c\/li\u003e\n\u003cli\u003eShort-circuit and ground fault protection = No\u003c\/li\u003e\n\u003cli\u003eContinuous power (supply and regeneration) = 60 kW\u003c\/li\u003e\n\u003cli\u003ePeak power (supply and regeneration) = 120 kW\u003c\/li\u003e\n\u003cli\u003eDC bus capacitance = 1650 µF\u003c\/li\u003e\n\u003cli\u003eVariant = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput voltage = 25 VDC ±1.6%\u003c\/li\u003e\n\u003cli\u003eInput capacitance = 4.7 µF\u003c\/li\u003e\n\u003cli\u003eMax. power consumption = 27 W + P SLOT1 + P SLOT2 + P 24 V Out + P Fan8BVF...\u003c\/li\u003e\n\u003cli\u003eVariant = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC Out\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput voltage\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 260 to 315 VDC = 25 VDC * (U DC \/ 315)\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 315 to 800 VDC = 24 VDC ±6%\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eFuse protection = 250 mA (slow-blow) electronic, automatic reset\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFilter fan connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eOverload protection = No\u003c\/li\u003e\n\u003cli\u003eShort-circuit proof = Yes\u003c\/li\u003e\n\u003cli\u003eOpen-circuit monitoring = No\u003c\/li\u003e\n\u003cli\u003eUndervoltage monitoring = No\u003c\/li\u003e\n\u003cli\u003eOutput voltage = 24 V +5.8% \/ -0.1%\u003c\/li\u003e\n\u003cli\u003eContinuous current = 4.2 A\u003c\/li\u003e\n\u003cli\u003eMax. overcurrent limiting = 10 A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrigger inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eInput - Power supply module = Yes\u003c\/li\u003e\n\u003cli\u003eInput - Input = Yes\u003c\/li\u003e\n\u003cli\u003eInput voltage\u003c\/li\u003e\n\u003cli\u003eNominal = 24 VDC\u003c\/li\u003e\n\u003cli\u003eMaximum = 30 VDC\u003c\/li\u003e\n\u003cli\u003eSwitching threshold\u003c\/li\u003e\n\u003cli\u003eLow = \u0026lt;5 V\u003c\/li\u003e\n\u003cli\u003eHigh = \u0026gt;15 V\u003c\/li\u003e\n\u003cli\u003eSwitching delay\u003c\/li\u003e\n\u003cli\u003eRising edge = 52 μs ±0.5 μs (digitally filtered)\u003c\/li\u003e\n\u003cli\u003eFalling edge = 53 μs ±0.5 μs (digitally filtered)\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eCircuit = Sink\u003c\/li\u003e\n\u003cli\u003eInput current at nominal voltage = Approx. 10 mA\u003c\/li\u003e\n\u003cli\u003eModulation compared to ground potential = Max. ±38 V\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160959799549,"sku":"8BVP0880HC00-004-1","price":13877.73,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/8BVP0880HC00-004-1.jpg?v=1785723297","url":"https:\/\/shly-plc.com\/products\/8bvp0880hc00-004-1","provider":"Lianyou PLC","version":"1.0","type":"link"}