{"product_id":"8bvi0014hwd0-000-1","title":"B\u0026R 8BVI0014HWD0-000-1 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Motion control \u0026gt; ACOPOSmulti \u0026gt; Inverter modules (two-axis modules) \u0026gt; Wall mounting\u003c\/p\u003e\n\u003cp\u003eUncontrolled stops and safe stop integrated Integrated connection for motor motor holding brake and temperature sensor 2 slots for ACOPOSmulti plug-in modules Double axis modules contain two complete standalone inverters in an inverter module ACOPOSmulti inverter module, 1.9 A, AS, wall mounting, 2 axes.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupport\u003c\/li\u003e\n\u003cli\u003eDynamic node allocation (DNA) = Yes\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = Evaluation ongoing\u003c\/li\u003e\n\u003cli\u003eFunctional safety = Yes\u003c\/li\u003e\n\u003cli\u003eUL = cULus E225616 Power conversion equipment\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0x26DF\u003c\/li\u003e\n\u003cli\u003eCooling and mounting type = Wall mounting\u003c\/li\u003e\n\u003cli\u003eSlots for plug-in modules = 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDC bus connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage\u003c\/li\u003e\n\u003cli\u003eNominal = 750 VDC\u003c\/li\u003e\n\u003cli\u003ePower dissipation depending on switching frequency\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz = [1.2 * I M ² + 2.62 * I M + 100] W\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz = [2.56 * I M ² + 2.8 * I M + 200] W\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 20 kHz = [6 * I M ² - 9.4 * I M + 430] W\u003c\/li\u003e\n\u003cli\u003eContinuous power consumption = 2.91 kW\u003c\/li\u003e\n\u003cli\u003eDC bus capacitance = 165 µF\u003c\/li\u003e\n\u003cli\u003eVariant = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput voltage = 25 VDC ±1.6%\u003c\/li\u003e\n\u003cli\u003eInput capacitance = 23.5 µF\u003c\/li\u003e\n\u003cli\u003eMax. power consumption = 16 W + P SLOT1 + P SLOT2 + P 24 V Out + P HoldingBrake(s)\u003c\/li\u003e\n\u003cli\u003eVariant = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC output\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput voltage\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 260 to 315 VDC = 25 VDC * (U DC \/315)\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 315 to 800 VDC = 24 VDC ±6%\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eFuse protection = 250 mA (slow-blow) electronic, automatic reset\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMotor connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReduction of continuous current depending on switching frequency\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz = No reduction\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz = No reduction\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 20 kHz = 0.11 A\/K (starting at 15°C)\u003c\/li\u003e\n\u003cli\u003eReduction of continuous current depending on installation elevation\u003c\/li\u003e\n\u003cli\u003eStarting at 500 m above sea level = 0.19 A eff per 1000 m\u003c\/li\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eOverload protection = Yes\u003c\/li\u003e\n\u003cli\u003eShort-circuit and ground fault protection = Yes\u003c\/li\u003e\n\u003cli\u003eVariant\u003c\/li\u003e\n\u003cli\u003eU, V, W, PE = Connector\u003c\/li\u003e\n\u003cli\u003eShield connection = Yes\u003c\/li\u003e\n\u003cli\u003eTerminal connection cross section\u003c\/li\u003e\n\u003cli\u003eFlexible and fine-stranded wires\u003c\/li\u003e\n\u003cli\u003eWith wire end sleeve = 0.25 to 6 mm²\u003c\/li\u003e\n\u003cli\u003eApprobation data\u003c\/li\u003e\n\u003cli\u003eUL\/C-UL-US = 30 to 10 AWG\u003c\/li\u003e\n\u003cli\u003eCSA = 28 to 10 AWG\u003c\/li\u003e\n\u003cli\u003eMax. motor line length depending on switching frequency\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz = 25 m\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz = 25 m\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 20 kHz = 10 m\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eContinuous power per motor connection = 1.4 kW\u003c\/li\u003e\n\u003cli\u003eContinuous current per motor connection = 1.9 A eff\u003c\/li\u003e\n\u003cli\u003ePeak current per motor connection = 4.7 A eff\u003c\/li\u003e\n\u003cli\u003eNominal switching frequency = 5 kHz\u003c\/li\u003e\n\u003cli\u003ePossible switching frequencies = 5 \/ 10 \/ 20 kHz\u003c\/li\u003e\n\u003cli\u003eInsulation stress of the connected motor per IEC TS 60034-25:2004 = Limit value curve A\u003c\/li\u003e\n\u003cli\u003eMax. output frequency = 598 Hz\u003c\/li\u003e\n\u003cli\u003eTerminal cable cross section dimension of shield connection = 12 to 22 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMotor holding brake connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eOverload and short-circuit protection = Yes\u003c\/li\u003e\n\u003cli\u003eOpen-circuit monitoring = Yes\u003c\/li\u003e\n\u003cli\u003eUndervoltage monitoring = Yes\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eOutput voltage = 24 VDC +5.8% \/ -0%\u003c\/li\u003e\n\u003cli\u003eContinuous current per connection = 1.1 A\u003c\/li\u003e\n\u003cli\u003eMax. internal resistance = 0.5 Ω\u003c\/li\u003e\n\u003cli\u003eExtinction potential = Approx. 30 V\u003c\/li\u003e\n\u003cli\u003eMax. extinction energy per switching operation = 1.5 Ws\u003c\/li\u003e\n\u003cli\u003eMax. switching frequency = 0.5 Hz\u003c\/li\u003e\n\u003cli\u003eResponse threshold for open-circuit monitoring = Approx. 0.25 A\u003c\/li\u003e\n\u003cli\u003eResponse threshold for undervoltage monitoring = 24 VDC +0% \/ -4%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnable inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eInput - Inverter module = Yes\u003c\/li\u003e\n\u003cli\u003eInput - Input = Yes\u003c\/li\u003e\n\u003cli\u003eInput voltage\u003c\/li\u003e\n\u003cli\u003eNominal = 24 VDC\u003c\/li\u003e\n\u003cli\u003eMaximum = 30 VDC\u003c\/li\u003e\n\u003cli\u003eSwitching threshold\u003c\/li\u003e\n\u003cli\u003eLow = \u0026lt;5 V\u003c\/li\u003e\n\u003cli\u003eHigh = \u0026gt;15 V\u003c\/li\u003e\n\u003cli\u003eSwitching delay at nominal input voltage\u003c\/li\u003e\n\u003cli\u003eEnable 1 → 0, PWM off = Max. 20.5 ms\u003c\/li\u003e\n\u003cli\u003eEnable 0 → 1, ready for PWM = Max. 100 µs\u003c\/li\u003e\n\u003cli\u003eQuantity = 4 (2 per axis)\u003c\/li\u003e\n\u003cli\u003eCircuit = Sink\u003c\/li\u003e\n\u003cli\u003eInput current at nominal voltage = Approx. 30 mA\u003c\/li\u003e\n\u003cli\u003eModulation compared to ground potential = Max. ±38 V\u003c\/li\u003e\n\u003cli\u003eOSSD signal connections = Permitted Max. test pulse length: 500 µs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrigger inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eInput - Inverter module = Yes\u003c\/li\u003e\n\u003cli\u003eInput - Input = Yes\u003c\/li\u003e\n\u003cli\u003eInput voltage\u003c\/li\u003e\n\u003cli\u003eNominal = 24 VDC\u003c\/li\u003e\n\u003cli\u003eMaximum = 30 VDC\u003c\/li\u003e\n\u003cli\u003eSwitching threshold\u003c\/li\u003e\n\u003cli\u003eLow = \u0026lt;5 V\u003c\/li\u003e\n\u003cli\u003eHigh = \u0026gt;15 V\u003c\/li\u003e\n\u003cli\u003eSwitching delay\u003c\/li\u003e\n\u003cli\u003eRising edge = 52 µs ±0.5 µs (digitally filtered)\u003c\/li\u003e\n\u003cli\u003eFalling edge = 53 µs ±0.5 µs (digitally filtered)\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eCircuit = Sink\u003c\/li\u003e\n\u003cli\u003eInput current at nominal voltage = Approx. 10 mA\u003c\/li\u003e\n\u003cli\u003eModulation compared to ground potential = Max. ±38 V\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160963305725,"sku":"8BVI0014HWD0-000-1","price":4892.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/8BVI0014HWD0-000-1.jpg?v=1785723187","url":"https:\/\/shly-plc.com\/products\/8bvi0014hwd0-000-1","provider":"Lianyou PLC","version":"1.0","type":"link"}