{"product_id":"8bve0500hc00-000-1","title":"B\u0026R 8BVE0500HC00-000-1 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Motion control \u0026gt; ACOPOSmulti \u0026gt; Expansion modules \u0026gt; Cold plate or feed-through mounting\u003c\/p\u003e\n\u003cp\u003eFor distributing the DC bus power supply and 24 VDC auxiliary supply to multiple mounting plates For setting up decentralized units in the ACOPOSmulti drive system Output for overload protection ACOPOSmulti expansion module 40 A, AS, cold plate or pass-through mounting.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = Not applicable\u003c\/li\u003e\n\u003cli\u003eUL = cULus E225616 Power conversion equipment\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eCooling and mounting type = Cold plate or pass-through mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDC bus connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage\u003c\/li\u003e\n\u003cli\u003eNominal = 750 VDC\u003c\/li\u003e\n\u003cli\u003eContinuous power depending on fuse\u003c\/li\u003e\n\u003cli\u003e10 A = 6 kW\u003c\/li\u003e\n\u003cli\u003e20 A = 12 kW\u003c\/li\u003e\n\u003cli\u003e50 A = 30 kW\u003c\/li\u003e\n\u003cli\u003eContinuous current depending on fuse\u003c\/li\u003e\n\u003cli\u003e10 A = 8 A eff\u003c\/li\u003e\n\u003cli\u003e20 A = 16 A eff\u003c\/li\u003e\n\u003cli\u003e50 A = 40 A eff\u003c\/li\u003e\n\u003cli\u003eReduction of continuous power depending on installation elevation\u003c\/li\u003e\n\u003cli\u003eStarting at 500 m above sea level = 10% per 1000 m\u003c\/li\u003e\n\u003cli\u003ePeak current depending on fuse\u003c\/li\u003e\n\u003cli\u003e10 A = 20 A\u003c\/li\u003e\n\u003cli\u003e20 A = 40 A\u003c\/li\u003e\n\u003cli\u003e50 A = 100 A\u003c\/li\u003e\n\u003cli\u003eReduction of continuous power at ambient temperatures starting at 40°C = 1.25% per °Kelvin\u003c\/li\u003e\n\u003cli\u003eReduction of continuous power depending on cooling method = No reduction\u003c\/li\u003e\n\u003cli\u003ePower dissipation with continuous power = 200 W\u003c\/li\u003e\n\u003cli\u003eVariant = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous power depending on fuse\u003c\/li\u003e\n\u003cli\u003e12 A = 240 W\u003c\/li\u003e\n\u003cli\u003e20 A = 400 W\u003c\/li\u003e\n\u003cli\u003e30 A = 600 W\u003c\/li\u003e\n\u003cli\u003eInput voltage = 25 VDC ±1.6%\u003c\/li\u003e\n\u003cli\u003eMax. power consumption = 5 W\u003c\/li\u003e\n\u003cli\u003eReduction of continuous power at ambient temperatures starting at 40°C = 1.25% per °Kelvin\u003c\/li\u003e\n\u003cli\u003eVariant = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDC bus cable outlet\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFuse protection\u003c\/li\u003e\n\u003cli\u003eType = 2x melting fuse ø 14 x 51 mm\u003c\/li\u003e\n\u003cli\u003eTripping characteristic = Ultra fast-acting\u003c\/li\u003e\n\u003cli\u003eRated current = 10 \/ 20 \/ 25 \/ 50 A\u003c\/li\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eFuse-dependent overload protection\u003c\/li\u003e\n\u003cli\u003e10 A = No (overload indicated via LED, dry alarm contacts present)\u003c\/li\u003e\n\u003cli\u003e20 A = No (overload indicated via LED, dry alarm contacts present)\u003c\/li\u003e\n\u003cli\u003e50 A = No (overload indicated via LED, dry alarm contacts present)\u003c\/li\u003e\n\u003cli\u003eShort-circuit and ground fault protection = Yes\u003c\/li\u003e\n\u003cli\u003eVariant\u003c\/li\u003e\n\u003cli\u003eDC+, DC-, PE = Connector\u003c\/li\u003e\n\u003cli\u003eShield connection = Yes\u003c\/li\u003e\n\u003cli\u003eTerminal connection cross section\u003c\/li\u003e\n\u003cli\u003eFlexible and fine-stranded wires\u003c\/li\u003e\n\u003cli\u003eWith wire end sleeve = 0.5 to 16 mm²\u003c\/li\u003e\n\u003cli\u003eApprobation data\u003c\/li\u003e\n\u003cli\u003eUL\/C-UL-US = 20 to 6 AWG\u003c\/li\u003e\n\u003cli\u003eCSA = 20 to 6 AWG\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eMax. line length between two expansion modules = 5 m\u003c\/li\u003e\n\u003cli\u003eTerminal cable cross section dimension of shield connection = 12 to 22 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC auxiliary supply cable outlet\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput voltage\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 260 to 315 VDC = 25 VDC * (DC bus voltage \/ 315)\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 315 to 800 VDC = 24 VDC ±6%\u003c\/li\u003e\n\u003cli\u003eFuse protection\u003c\/li\u003e\n\u003cli\u003eType = Melting fuse ø 10 x 38 mm\u003c\/li\u003e\n\u003cli\u003eTripping characteristic = Fast-acting\u003c\/li\u003e\n\u003cli\u003eRated current = 12 \/ 30 A\u003c\/li\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eOverload protection = Yes\u003c\/li\u003e\n\u003cli\u003eShort-circuit proof = Yes\u003c\/li\u003e\n\u003cli\u003eVariant\u003c\/li\u003e\n\u003cli\u003e24 VDC, COM = Connector\u003c\/li\u003e\n\u003cli\u003eShield connection = No\u003c\/li\u003e\n\u003cli\u003eTerminal connection cross section\u003c\/li\u003e\n\u003cli\u003eFlexible and fine-stranded wires\u003c\/li\u003e\n\u003cli\u003eWith wire end sleeve = 0.25 to 6 mm²\u003c\/li\u003e\n\u003cli\u003eApprobation data\u003c\/li\u003e\n\u003cli\u003eUL\/C-UL-US = 22 to 10 AWG\u003c\/li\u003e\n\u003cli\u003eCSA = 22 to 10 AWG\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eMax. line length between two expansion modules = 5 m\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAlarm contacts\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eType\u003c\/li\u003e\n\u003cli\u003eAlarm contact 1 = Normally closed contact\u003c\/li\u003e\n\u003cli\u003eAlarm contact 2 = Normally open contact\u003c\/li\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eAlarm contact - ACOPOSmulti module = Yes\u003c\/li\u003e\n\u003cli\u003eAlarm contact - Alarm contact = Yes\u003c\/li\u003e\n\u003cli\u003eProtection\u003c\/li\u003e\n\u003cli\u003eOverload-proof = No\u003c\/li\u003e\n\u003cli\u003eShort-circuit proof = No\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eNominal voltage = 30 VDC\u003c\/li\u003e\n\u003cli\u003eMaximum current = 1 A\u003c\/li\u003e\n\u003cli\u003eSwitching delay = 3 ms\u003c\/li\u003e\n\u003cli\u003eMax. number of switching cycles = 100,000\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperating conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePermissible mounting orientations\u003c\/li\u003e\n\u003cli\u003eHanging vertically = Yes\u003c\/li\u003e\n\u003cli\u003eHorizontal, face up = Yes\u003c\/li\u003e\n\u003cli\u003eStanding horizontally = No\u003c\/li\u003e\n\u003cli\u003eInstallation elevation above sea level\u003c\/li\u003e\n\u003cli\u003eNominal = 0 to 500 m\u003c\/li\u003e\n\u003cli\u003eMaximum = 4000 m\u003c\/li\u003e\n\u003cli\u003ePollution degree per EN 61800-5-1 = 2 (non-conductive pollution)\u003c\/li\u003e\n\u003cli\u003eOvervoltage category per EN 61800-5-1 = III\u003c\/li\u003e\n\u003cli\u003eDegree of protection per EN 60529 = IP20\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature\u003c\/li\u003e\n\u003cli\u003eOperation\u003c\/li\u003e\n\u003cli\u003eNominal = 5 to 40°C\u003c\/li\u003e\n\u003cli\u003eMaximum = 55°C\u003c\/li\u003e\n\u003cli\u003eStorage = -25 to 55°C\u003c\/li\u003e\n\u003cli\u003eTransport = -25 to 70°C\u003c\/li\u003e\n\u003cli\u003eRelative humidity\u003c\/li\u003e\n\u003cli\u003eOperation = 5 to 85%\u003c\/li\u003e\n\u003cli\u003eStorage = 5 to 95%\u003c\/li\u003e\n\u003cli\u003eTransport = Max. 95% at 40°C\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160963141885,"sku":"8BVE0500HC00-000-1","price":6013.35,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/8BVE0500HC00-000-1.jpg?v=1785723171","url":"https:\/\/shly-plc.com\/products\/8bve0500hc00-000-1","provider":"Lianyou PLC","version":"1.0","type":"link"}