{"product_id":"8b0p0220hw00-0011","title":"B\u0026R 8B0P0220HW00-0011 | B\u0026R","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Motion control \u0026gt; ACOPOSmulti \u0026gt; Passive power supply modules \u0026gt; Wall mounting\u003c\/p\u003e\n\u003cp\u003eWide input voltage range Integrated connection for external braking resistor Passive motor short circuit brake A motor with a hanging load is connected to an ACOPOSmulti drive system with passive power supply module 8B0P with passive motor short circuit brake.\u003c\/p\u003e\n\u003cp\u003eIf the power supply to the drive system is disconnected and the hanging load begins sinking (due to failure of the motor holding brake, for example), then the motor axis rotates and the DC bus voltage increases.\u003c\/p\u003e\n\u003cp\u003eIf the DC bus voltage overshoots a value of 15 VDC, then the DC bus is shorted via a thyristor.\u003c\/p\u003e\n\u003cp\u003eThis limits the speed at which the hanging load sinks.\u003c\/p\u003e\n\u003cp\u003eThe passive motor short circuit brake is designed for up to 25 kW of power.\u003c\/p\u003e\n\u003cp\u003eOne fault event is permitted to occur maximum once every 15 minutes for this amount of power.\u003c\/p\u003e\n\u003cp\u003eThe passive motor short circuit brake is always active and cannot be influenced by the user! The passive motor short circuit brake works without current limiting.\u003c\/p\u003e\n\u003cp\u003eAs a result, irreparable damage to drive system components (passive power supply module 8B0P, motor, etc.) is possible at excessively high power values.\u003c\/p\u003e\n\u003cp\u003eThe passive motor short circuit brake is not monitored.\u003c\/p\u003e\n\u003cp\u003eIt therefore has no effect in the event of component failure! ACOPOSmulti power supply module passive, 22 A, AS, wall mounting, passive motor short circuit brake.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupport\u003c\/li\u003e\n\u003cli\u003eDynamic node allocation (DNA) = Yes\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = In preparation\u003c\/li\u003e\n\u003cli\u003eUL = cULus E225616 Power conversion equipment\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eNote = Integrated passive motor short circuit brake\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0xA988\u003c\/li\u003e\n\u003cli\u003eCooling and mounting type = Wall mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMains connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMax. chargeable DC bus capacitance depending on mains voltage\u003c\/li\u003e\n\u003cli\u003e400 VAC = 14.4 mF\u003c\/li\u003e\n\u003cli\u003e480 VAC = 10 mF\u003c\/li\u003e\n\u003cli\u003eExecution\u003c\/li\u003e\n\u003cli\u003eL1, L2, L3, PE = Connector\u003c\/li\u003e\n\u003cli\u003ePE = M5 threaded bolt\u003c\/li\u003e\n\u003cli\u003eShield connection = Yes\u003c\/li\u003e\n\u003cli\u003eTerminal connection cross section\u003c\/li\u003e\n\u003cli\u003eFlexible and fine-stranded wires\u003c\/li\u003e\n\u003cli\u003eWith wire end sleeve = 0.5 to 16 mm²\u003c\/li\u003e\n\u003cli\u003eApprobation data\u003c\/li\u003e\n\u003cli\u003eUL\/C-UL-US = 20 to 6 AWG\u003c\/li\u003e\n\u003cli\u003eCSA = 20 to 6 AWG\u003c\/li\u003e\n\u003cli\u003eNetwork configurations = TT, TN-S, TN-C-S\u003c\/li\u003e\n\u003cli\u003eMains input voltage = 3x 380 to 3x 500 VAC ±10%\u003c\/li\u003e\n\u003cli\u003eFrequency = 50 \/ 60 Hz ±4%\u003c\/li\u003e\n\u003cli\u003eInstalled load = Max. 15.6 kVA\u003c\/li\u003e\n\u003cli\u003ePower dissipation with continuous power = Approx. 130 W\u003c\/li\u003e\n\u003cli\u003eInrush current at 400 VAC = 10 A\u003c\/li\u003e\n\u003cli\u003eSwitch-on interval = \u0026gt;120 s\u003c\/li\u003e\n\u003cli\u003eIntegrated line filter per EN 61800-3, category C3 = No\u003c\/li\u003e\n\u003cli\u003eIntegrated regeneration choke = No\u003c\/li\u003e\n\u003cli\u003eRegenerative = No\u003c\/li\u003e\n\u003cli\u003ePower factor correction (PFC) = No\u003c\/li\u003e\n\u003cli\u003eLine fuse = Max. 66 A (gG fuses per IEC 60269-1 or Class CC, J, T) Max. 55 A (circuit breaker per EN 60947-2 or UL 489)\u003c\/li\u003e\n\u003cli\u003eTerminal cable cross section dimension of shield connection = 23 to 35 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDC bus connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage\u003c\/li\u003e\n\u003cli\u003eNominal = 537 to 707 VDC\u003c\/li\u003e\n\u003cli\u003eReduction of continuous power depending on mains input voltage\u003c\/li\u003e\n\u003cli\u003eMains input voltage \u0026lt;3x 400 VAC = 20 W\/V * (400 V - Mains input voltage)\u003c\/li\u003e\n\u003cli\u003eReduction of continuous power depending on installation elevation\u003c\/li\u003e\n\u003cli\u003eStarting at 500 m above sea level = 0.8 kW per 1000 m\u003c\/li\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eOverload protection = Yes\u003c\/li\u003e\n\u003cli\u003eShort-circuit and ground fault protection = No\u003c\/li\u003e\n\u003cli\u003eContinuous power = 8 kW\u003c\/li\u003e\n\u003cli\u003eReduction of continuous power depending on cooling method = In preparation\u003c\/li\u003e\n\u003cli\u003ePeak power output (supply) = 24 kW\u003c\/li\u003e\n\u003cli\u003ePower dissipation with continuous power = In preparation\u003c\/li\u003e\n\u003cli\u003eDC bus capacitance = 660 µF\u003c\/li\u003e\n\u003cli\u003eExecution = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput voltage = 25 VDC ±1.6%\u003c\/li\u003e\n\u003cli\u003eInput capacitance = 23.5 µF\u003c\/li\u003e\n\u003cli\u003eMax. power consumption = 12 W\u003c\/li\u003e\n\u003cli\u003eExecution = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMotor holding brake connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTerminal connection cross section\u003c\/li\u003e\n\u003cli\u003eFlexible and fine-stranded wires\u003c\/li\u003e\n\u003cli\u003eWith wire end sleeve = 0.5 to 6 mm²\u003c\/li\u003e\n\u003cli\u003eApprobation data\u003c\/li\u003e\n\u003cli\u003eUL\/C-UL-US = 20 to 6 AWG\u003c\/li\u003e\n\u003cli\u003eCSA = 20 to 6 AWG\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBraking resistor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExecution\u003c\/li\u003e\n\u003cli\u003eRB+, RB-, PE = Connector\u003c\/li\u003e\n\u003cli\u003eShield connection = Yes\u003c\/li\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eOverload protection = Yes\u003c\/li\u003e\n\u003cli\u003eShort-circuit and ground fault protection = Yes (with RB+ by externally replaceable melting fuse)\u003c\/li\u003e\n\u003cli\u003ePeak power output = 40 kW (max. 1 s)\u003c\/li\u003e\n\u003cli\u003eContinuous power = 3 kW\u003c\/li\u003e\n\u003cli\u003eMin. braking resistance = 12 Ω\u003c\/li\u003e\n\u003cli\u003eRated current of built-in fuse = 30 A (fast-acting)\u003c\/li\u003e\n\u003cli\u003eTerminal cable cross section dimension of shield connection = 23 to 35 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEnergy efficiency (IE classification)\u003c\/li\u003e\n\u003cli\u003ePower dissipation relative to continuous apparent power = IE2 (10;25) 0.4% IE2 (50;25) 0.5% IE2 (10;50) 0.4% IE2 (50;50) 0.6% IE2 (90;50) 0.8% IE2 (10;100) 0.5% IE2 (50;100) 0.8% IE2 (90;100) 1.5%\u003c\/li\u003e\n\u003cli\u003eNominal losses in standby mode = 6 W\u003c\/li\u003e\n\u003cli\u003eDischarge capacitance = 0.9 µF\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperating conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePermissible mounting orientations\u003c\/li\u003e\n\u003cli\u003eHanging vertically = Yes\u003c\/li\u003e\n\u003cli\u003eHorizontal, face up = Yes\u003c\/li\u003e\n\u003cli\u003eStanding horizontally = No\u003c\/li\u003e\n\u003cli\u003eInstallation elevation above sea level\u003c\/li\u003e\n\u003cli\u003eNominal = 0 to 500 m\u003c\/li\u003e\n\u003cli\u003eMaximum = 4000 m\u003c\/li\u003e\n\u003cli\u003ePollution degree per EN 61800-5-1 = 2 (non-conductive pollution)\u003c\/li\u003e\n\u003cli\u003eOvervoltage category per EN 61800-5-1 = III\u003c\/li\u003e\n\u003cli\u003eDegree of protection per EN 60529 = IP20\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature\u003c\/li\u003e\n\u003cli\u003eOperation\u003c\/li\u003e\n\u003cli\u003eNominal = 5 to 40°C\u003c\/li\u003e\n\u003cli\u003eMaximum = 55°C\u003c\/li\u003e\n\u003cli\u003eStorage = -25 to 55°C\u003c\/li\u003e\n\u003cli\u003eTransport = -25 to 70°C\u003c\/li\u003e\n\u003cli\u003eRelative humidity\u003c\/li\u003e\n\u003cli\u003eOperation = 5 to 85%\u003c\/li\u003e\n\u003cli\u003eStorage = 5 to 95%\u003c\/li\u003e\n\u003cli\u003eTransport = Max. 95% at 40°C\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"Never Used Surplus","offer_id":70984813838589,"sku":"8B0P0220HW00-0011","price":7749.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/8B0P0220HW00-0011.jpg?v=1785722811","url":"https:\/\/shly-plc.com\/products\/8b0p0220hw00-0011","provider":"Lianyou PLC","version":"1.0","type":"link"}