{"product_id":"8b0c0320hw00-000-1","title":"B\u0026R 8B0C0320HW00-000-1 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Motion control \u0026gt; ACOPOSmulti \u0026gt; Auxiliary supply modules 800W \u0026gt; Wall mounting\u003c\/p\u003e\n\u003cp\u003eExtensive protective measures ACOPOSmulti auxiliary supply module, 32 A, AS, wall mounting.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = In preparation\u003c\/li\u003e\n\u003cli\u003eUL = cULus E225616 Power conversion equipment\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eCooling and mounting type = Wall mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDC bus connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage\u003c\/li\u003e\n\u003cli\u003eNominal = 750 VDC\u003c\/li\u003e\n\u003cli\u003eOperating range in continuous operation = 260 to 800 VDC\u003c\/li\u003e\n\u003cli\u003eFull continuous power = 315 to 800 VDC\u003c\/li\u003e\n\u003cli\u003eContinuous power consumption = Max. 880 W\u003c\/li\u003e\n\u003cli\u003ePower dissipation with continuous power = 22 W (0% continuous power) 35 W (50% continuous power) 80 W (100% continuous power)\u003c\/li\u003e\n\u003cli\u003eDC bus capacitance = 220 nF\u003c\/li\u003e\n\u003cli\u003eVariant = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC output\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput voltage\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 260 to 315 VDC = 25 VDC * (U DC \/ 315)\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 315 to 800 VDC = 24 VDC ±6%\u003c\/li\u003e\n\u003cli\u003eReduction of continuous power depending on installation elevation\u003c\/li\u003e\n\u003cli\u003eStarting at 500 m above sea level = 80 W per 1000 m\u003c\/li\u003e\n\u003cli\u003eContinuous power = 800 W\u003c\/li\u003e\n\u003cli\u003eContinuous current = 32 ADC\u003c\/li\u003e\n\u003cli\u003eReduction of continuous power at ambient temperatures starting at 40°C = No reduction\u003c\/li\u003e\n\u003cli\u003eReduction of continuous power depending on cooling method = No reduction\u003c\/li\u003e\n\u003cli\u003eStartup delay = Max. 1 s\u003c\/li\u003e\n\u003cli\u003eStartup time = Approx. 5 to 20 ms\u003c\/li\u003e\n\u003cli\u003eResidual ripple = Typ. 50 mV SS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC internal system power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePeak current (\u0026lt;4 s)\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 350 to 800 VDC = 42 ADC\u003c\/li\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eNo-load proof = Yes\u003c\/li\u003e\n\u003cli\u003eOverload-proof = Yes\u003c\/li\u003e\n\u003cli\u003eShort-circuit proof = Yes\u003c\/li\u003e\n\u003cli\u003eFeedback protection = Max. 26 VDC (also when the power is switched off)\u003c\/li\u003e\n\u003cli\u003eOvertemperature protection = Yes\u003c\/li\u003e\n\u003cli\u003eDielectric strength to ground = ±50 VDC\u003c\/li\u003e\n\u003cli\u003eOutput\/Input isolation = SELV \/ PELV requirements\u003c\/li\u003e\n\u003cli\u003eOutput voltage = 25 VDC ±1.6%\u003c\/li\u003e\n\u003cli\u003eVariant = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperating conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePermissible mounting orientations\u003c\/li\u003e\n\u003cli\u003eHanging vertically = Yes\u003c\/li\u003e\n\u003cli\u003eHorizontal, face up = Yes\u003c\/li\u003e\n\u003cli\u003eStanding horizontally = No\u003c\/li\u003e\n\u003cli\u003eInstallation elevation above sea level\u003c\/li\u003e\n\u003cli\u003eNominal = 0 to 500 m\u003c\/li\u003e\n\u003cli\u003eMaximum = 4000 m\u003c\/li\u003e\n\u003cli\u003ePollution degree per EN 61800-5-1 = 2 (non-conductive pollution)\u003c\/li\u003e\n\u003cli\u003eOvervoltage category per EN 61800-5-1 = III\u003c\/li\u003e\n\u003cli\u003eDegree of protection per EN 60529 = IP20\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature\u003c\/li\u003e\n\u003cli\u003eOperation\u003c\/li\u003e\n\u003cli\u003eNominal = 5 to 40°C\u003c\/li\u003e\n\u003cli\u003eMaximum = 55°C\u003c\/li\u003e\n\u003cli\u003eStorage = -25 to 55°C\u003c\/li\u003e\n\u003cli\u003eTransport = -25 to 70°C\u003c\/li\u003e\n\u003cli\u003eRelative humidity\u003c\/li\u003e\n\u003cli\u003eOperation = 5 to 85%\u003c\/li\u003e\n\u003cli\u003eStorage = 5 to 95%\u003c\/li\u003e\n\u003cli\u003eTransport = Max. 95% at 40°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDimensions\u003c\/li\u003e\n\u003cli\u003eDepth\u003c\/li\u003e\n\u003cli\u003eWall mounting = 263 mm\u003c\/li\u003e\n\u003cli\u003eWidth = 53 mm\u003c\/li\u003e\n\u003cli\u003eHeight = 317 mm\u003c\/li\u003e\n\u003cli\u003eWeight = Approx. 3 kg\u003c\/li\u003e\n\u003cli\u003eModule width = 1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160964911357,"sku":"8B0C0320HW00-000-1","price":3927.55,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/8B0C0320HW00-000-1.jpg?v=1785723144","url":"https:\/\/shly-plc.com\/products\/8b0c0320hw00-000-1","provider":"Lianyou PLC","version":"1.0","type":"link"}