{"product_id":"80sd100xd-c0xx-01","title":"B\u0026R 80SD100XD-C0XX-01 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Motion control \u0026gt; ACOPOSmicro \u0026gt; Stepper motor modules\u003c\/p\u003e\n\u003cp\u003eControl for 2 stepper motors (2-phase bipolar, full bridge) 256 microsteps per step 2 trigger inputs Motor holding brake connection Enable input Automatic motor identification Holding, boost and continuous current can be defined independent of one another ACOPOSmicro stepper motor module, X2X Link interface, 24-64 VDC ±25% power supply, 2 motor connections, 10 A continuous current, 2 digital inputs 24 VDC, sink, can be used as trigger inputs, 1 digital output 24 VDC, 1 A, order terminal blocks separately!.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eShort description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStepper motor module = Connection for two stepper motors without encoder, 2-phase bipolar\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDiagnostics\u003c\/li\u003e\n\u003cli\u003eModule run\/error = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003eModule temperature \/ Cooling unit temperature = Yes, using software\u003c\/li\u003e\n\u003cli\u003eMotor status = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003eX2X Link = Yes, using LED status indicator\u003c\/li\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eCPU - 24 VDC power supply = No\u003c\/li\u003e\n\u003cli\u003eCPU - Power supply = Yes\u003c\/li\u003e\n\u003cli\u003eCPU - Motor connection = Yes\u003c\/li\u003e\n\u003cli\u003eCPU - Digital inputs = Yes\u003c\/li\u003e\n\u003cli\u003eCPU - Enable inputs = Yes\u003c\/li\u003e\n\u003cli\u003eCPU - Motor holding brake = No\u003c\/li\u003e\n\u003cli\u003eCPU - X2X Link = Yes\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = In preparation\u003c\/li\u003e\n\u003cli\u003eFunctional safety = Yes\u003c\/li\u003e\n\u003cli\u003eUL = cULus E225616 Power conversion equipment\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0xA4A4\u003c\/li\u003e\n\u003cli\u003eStatus indicators = X2X Link, operating state, module status, motor information\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower consumption\u003c\/li\u003e\n\u003cli\u003eCPU = Max. 6 W\u003c\/li\u003e\n\u003cli\u003eX2X Link power supply = Generated internally from the CPU power supply\u003c\/li\u003e\n\u003cli\u003eInput voltage = 24 VDC ±25%\u003c\/li\u003e\n\u003cli\u003eVoltage monitoring = Yes\u003c\/li\u003e\n\u003cli\u003eReverse polarity protection = Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower consumption\u003c\/li\u003e\n\u003cli\u003eIdle (no motor powered) = Max. 0.5 W\u003c\/li\u003e\n\u003cli\u003eFull load = See diagram \"Dimensioning - Power dissipation from the power unit for each powered axis\"\u003c\/li\u003e\n\u003cli\u003eInput voltage = 24 to 64 VDC ±25%\u003c\/li\u003e\n\u003cli\u003eInrush current = Max. 10 A\u003c\/li\u003e\n\u003cli\u003eInrush current limiting = Yes, PTC (min. 9 Ω), is bypassed during operation by means of relay contact.\u003c\/li\u003e\n\u003cli\u003eUndervoltage cutoff = \u0026lt;18 VDC\u003c\/li\u003e\n\u003cli\u003eOvervoltage cutoff = \u0026gt;95 VDC\u003c\/li\u003e\n\u003cli\u003eVoltage measurement = Yes\u003c\/li\u003e\n\u003cli\u003eLine protection = Must occur externally\u003c\/li\u003e\n\u003cli\u003eReverse polarity protection = Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMotor connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eNominal current = 10 A Peak\u003c\/li\u003e\n\u003cli\u003eMax. current\/motor = 15 A Peak (2 s)\u003c\/li\u003e\n\u003cli\u003eMax. current\/module = 30 A Peak\u003c\/li\u003e\n\u003cli\u003eNominal switching frequency = 38.5 kHz\u003c\/li\u003e\n\u003cli\u003eMax. motor line length = 25 m\u003c\/li\u003e\n\u003cli\u003eStep resolution = 256 microsteps per full step\u003c\/li\u003e\n\u003cli\u003eDC bus capacitance = 940 µF\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMotor holding brake connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSwitching frequency\u003c\/li\u003e\n\u003cli\u003eResistive load = 100 Hz\u003c\/li\u003e\n\u003cli\u003eInductive load = See section \"Switching inductive loads\"\u003c\/li\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eOverload and short-circuit protection = Yes\u003c\/li\u003e\n\u003cli\u003eOpen-circuit monitoring = No\u003c\/li\u003e\n\u003cli\u003eUndervoltage monitoring = Yes\u003c\/li\u003e\n\u003cli\u003eQuantity = 1\u003c\/li\u003e\n\u003cli\u003eNominal voltage = 24 VDC\u003c\/li\u003e\n\u003cli\u003eInput voltage = 24 VDC ±25%\u003c\/li\u003e\n\u003cli\u003eContinuous current per connection = 1 A\u003c\/li\u003e\n\u003cli\u003eMax. internal resistance = 0.3 Ω\u003c\/li\u003e\n\u003cli\u003eMax. overcurrent limiting = 8 A\u003c\/li\u003e\n\u003cli\u003eResponse threshold for undervoltage monitoring = ≤11 VDC\u003c\/li\u003e\n\u003cli\u003eReference potential = GND for module power supply (X2 terminal, pin 10)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInterfaces\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eX2X\u003c\/li\u003e\n\u003cli\u003eExecution = 4-pin male connector\u003c\/li\u003e\n\u003cli\u003eMin. X2X Link cycle time = 250 μs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnable inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSwitching threshold\u003c\/li\u003e\n\u003cli\u003eLow = \u0026lt;5 VDC\u003c\/li\u003e\n\u003cli\u003eHigh = \u0026gt;15 VDC\u003c\/li\u003e\n\u003cli\u003eSwitching delay at nominal input voltage\u003c\/li\u003e\n\u003cli\u003eEnable 1 → 0, PWM off\u003c\/li\u003e\n\u003cli\u003eMaximum = 450 ms (Rev. \u0026lt; L0: 452 ms)\u003c\/li\u003e\n\u003cli\u003eEnable 0 → 1, ready for PWM\u003c\/li\u003e\n\u003cli\u003eMaximum = 500 ms\u003c\/li\u003e\n\u003cli\u003eQuantity = 1\u003c\/li\u003e\n\u003cli\u003eNominal voltage = 24 VDC\u003c\/li\u003e\n\u003cli\u003eInput voltage = 24 VDC ±25%\u003c\/li\u003e\n\u003cli\u003eInput current at nominal voltage = Typ. 60 mA\u003c\/li\u003e\n\u003cli\u003eInput circuit = Sink\u003c\/li\u003e\n\u003cli\u003eInsulation voltage between input and bus = 500 V eff\u003c\/li\u003e\n\u003cli\u003eInput capacitance = 10 nF (Rev. \u0026lt; L0: 100 µF)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital inputs \/ Trigger inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput voltage\u003c\/li\u003e\n\u003cli\u003eNominal = 24 VDC\u003c\/li\u003e\n\u003cli\u003eMaximum = 30 VDC\u003c\/li\u003e\n\u003cli\u003eSwitching threshold\u003c\/li\u003e\n\u003cli\u003eLow = \u0026lt;5 VDC\u003c\/li\u003e\n\u003cli\u003eHigh = \u0026gt;15 VDC\u003c\/li\u003e\n\u003cli\u003eSwitching delay\u003c\/li\u003e\n\u003cli\u003eRising edge = [Instant recording] Typ. 3 µs\u003c\/li\u003e\n\u003cli\u003eFalling edge = [Instant recording] Typ. 4 µs\u003c\/li\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eInput - ACOPOS = Yes, 500 V eff\u003c\/li\u003e\n\u003cli\u003eInput - Input = Yes, 500 V eff\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eAdditional functions = Can be used as trigger input\u003c\/li\u003e\n\u003cli\u003eInput circuit = Sink\u003c\/li\u003e\n\u003cli\u003eInput current at nominal voltage = Approx. 7.5 mA\u003c\/li\u003e\n\u003cli\u003eInput resistance = Approx. 3.2 kΩ\u003c\/li\u003e\n\u003cli\u003eModulation compared to ground potential = Max. ±38 V\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160966320381,"sku":"80SD100XD-C0XX-01","price":5372.51,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/80SD100XD-C0XX-01.jpg?v=1785723082","url":"https:\/\/shly-plc.com\/products\/80sd100xd-c0xx-01","provider":"Lianyou PLC","version":"1.0","type":"link"}