{"title":"Mitsubishi","description":"\u003cp\u003eBrowse Mitsubishi industrial automation products including MELSEC PLCs (Q series, FX series), GOT HMI panels, servo amplifiers, inverters, and I\/O modules. Quality Mitsubishi parts in stock with fast global delivery.\u003c\/p\u003e","products":[{"product_id":"qy10","title":"Mitsubishi QY10 | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi QY10\u003c\/h2\u003e\n\u003cp\u003eQY10\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cp\u003eContact output: 16 points, 24 V DC\/240 V AC, 2 A\/point, 8 A\/common, response time: 12 ms, 16 points\/common, 18-point terminal block | Conformance: UL cUL CE(EMC) CE(LVD) CE(RoHS) KC(EMC) LR NK DNV ABS RINA BV\u003c\/p\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eContact output: 16 points, 24 V DC\/240 V AC, 2 A\/point, 8 A\/common, response time: 12 ms, 16 points\/common, 18-point terminal block\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137177571581,"sku":"QY10","price":25.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/VaquqRacyJADimahgAKNpeN80yGJjlzu12Xwy8AuNuWHLRTXAQymxnGWCCvd.jpg?v=1742537116"},{"product_id":"qj71e71100","title":"Mitsubishi QJ71E71100 | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi QJ71E71-100\u003c\/h2\u003e\n\u003cp\u003eMELSEC-Q Series QJ71E71-100\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTransmission specifications - Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100BASE-TX\/10BASE-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTransmission specifications - Data transmission speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 Mbps\/10 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTransmission specifications - Flow control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100BASE-TX: None 10BASE-T: Back pressure congestion control(Half-duplex)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTransmission specifications - Communication mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100BASE-TX: Full-duplex\/half-duplex 10BASE-T: Half-duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTransmission specifications - Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRJ45 (Fixed to MDI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTransmission specifications - Transmission method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase band\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTransmission specifications - Maximum segment length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 m (length between hub and node)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSending\/receiving data storage memory - Number of simultaneously open connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 connections (connections usable on a program)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSending\/receiving data storage memory - Fixed buffer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1K words × 16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSending\/receiving data storage memory - Random access buffer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6K words × 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSending\/receiving data storage memory - E-mail - Attached file\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6K words × 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSending\/receiving data storage memory - E-mail - Main text\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e960 words × 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNumber of occupied I\/O points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 points (I\/O assignment: Intelligent 32 points)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInternal current consumption (5 V DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal dimensions - Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e98 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal dimensions - Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal dimensions - Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.11 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eGeneral specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRefer to the general specifications of the CPU module.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137177637117,"sku":"QJ71E71100","price":142.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/04_10_2022_13_29_12_QJ71E71_100_Mitsubishi.jpg?v=1742537119"},{"product_id":"fx3u-3a-adp","title":"Mitsubishi FX3U-3A-ADP | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi FX3U-3A-ADP\u003c\/h2\u003e\n\u003cp\u003eMELSEC-F Series FX3U-3A-ADP\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eApplicable PLC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFX3S, FX3G (Ver. 1.20 or later), FX3U (Ver. 2.61 or later), FX3GC, FX3UC (Ver. 2.61 or later) The FX3S-CNV-ADP is required to connect the FX3S PLC. The FX3G-CNV-ADP is required to connect the FX3G PLC. An expansion board is required to connect the FX3U,FX3UC-32MT-LT(-2).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNumber of occupied I\/O points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 point (This number is not related to the maximum number of input\/output points of the PLC.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMass (weight)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - Analog input range - Voltage input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 10 V DC (Input resistance 198.7 kΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - Analog input range - Current input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA DC (Input resistance 250 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - Number of input channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - Absolute maximum input - Voltage input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-0.5 V, +15 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - Absolute maximum input - Current input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-2 mA, +30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - Input characteristics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThe input mode (voltage\/current input) can be set for each channel.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - Digital output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 bits, binary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - Resolution - Voltage input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 mV (10 V × 1\/4000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - Resolution - Current input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 μA (16 mA × 1\/3200)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - Total accuracy - Voltage input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAmbient temperature: 25°C±5°C ±0.5% (±50 mV) for 10 V full scale Ambient temperature: 0°C to 55°C ±1.0% (±100 mV) for 10 V full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - Total accuracy - Current input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAmbient temperature: 25°C±5°C ±0.5% (±80 μA) for 16 mA full scale Ambient temperature: 0°C to 55°C ±1.0% (±160 μA) for 16 mA full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - A\/D conversion time - When FX3U\/FX3UC PLC is connected\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 μs for each selected input channel + 40 μs for each selected output channel (Operation synchronized with sequence program)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - A\/D conversion time - When FX3S\/FX3G\/FX3GC PLC is connected\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 μs for each selected input channel + 50 μs for each selected output channel (Operation synchronized with sequence program)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog output - Analog output range - Voltage output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 V to 10 V DC (External load resistance: 5 k to 1 MΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog output - Analog output range - Current output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA DC (External load resistance: 500 Ω or less)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog output - No. of output channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog output - Output characteristics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThe output mode (voltage\/current output) can be set.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog output - Digital input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 bits, binary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog output - Resolution - Voltage output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 mV (10 V × 1\/4000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog output - Resolution - Current output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 μA (16 mA × 1\/4000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog output - Total accuracy - Voltage output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAmbient temperature: 25°C±5°C ±0.5% (±50 mV) for 10 V full scale Ambient temperature: 0°C to 55°C ±1.0% (±100 mV) for 10 V full scale If the external load resistance (Rs) is less than 5 kΩ, the accuracy increases as shown in the following formula: (Increase: 100 mV per 1%) 47 × 100\/(Rs+47) - 0.9 (%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog output - Total accuracy - Current output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAmbient temperature: 25°C±5°C ±0.5% (±80 μA) for 16 mA full scale Ambient temperature: 0°C to 55°C ±1.0% (±160 μA) for 16 mA full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog output - Time required for D\/A conversion - When FX3U\/FX3UC PLC is connected\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 μs for each selected input channel + 40 μs for each selected output channel (Operation synchronized with sequence program)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog output - Time required for D\/A conversion - When FX3S\/FX3G\/FX3GC PLC is connected\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 μs for each selected input channel + 50 μs for each selected output channel (Operation synchronized with sequence program)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e  \/ 24 V DC +20% -15% 90 mA It is necessary to connect a 24 V DC power supply to the terminal block.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply - Conversion circuit driving power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 V DC 20 mA Internal power supply from the 5 V DC power supply unit of the main unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 55°C (32 to 131 °F) when operating and -25 to 75°C (-13 to 167 °F) when stored\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAmbient humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 to 95%RH (no condensation) when operating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eVibration resistance - Installed on DIN rail - Frequency: 10 to 57 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHalf amplitude: 0.035 mm Sweep Count for X, Y, Z: 10 times (80 min in each direction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eVibration resistance - Installed on DIN rail - Frequency: 57 to 150 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAcceleration: 4.9 m\/s 2 Sweep Count for X, Y, Z: 10 times (80 min in each direction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eVibration resistance - Direct installing - Frequency: 10 to 57 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHalf amplitude: 0.075 mm Sweep Count for X, Y, Z: 10 times (80 min in each direction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eVibration resistance - Direct installing - Frequency: 57 to 150 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAcceleration: 9.8 m\/s 2 Sweep Count for X, Y, Z: 10 times (80 min in each direction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eShock resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e147 m\/s 2 Acceleration, Action time: 11 ms, 3 times by half-sine pulse in each direction X, Y, and Z\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNoise resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBy noise simulator at noise voltage of 1,000 Vp-p, noise width of 1 μs, rise time of 1 ns and period of 30 to 100 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDielectric withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBetween batch of all terminals and ground terminal: 500 V AC for 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBetween batch of all terminals and ground terminal: 5 MΩ or higher by 500 V DC insulation resistance tester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eGrounding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass D grounding (grounding resistance: 100 Ω or less) (Common grounding with a heavy electrical system is not allowed) Ground the PLC independently or jointly.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eWorking atmosphere\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFree from corrosive or flammable gas and excessive conductive dusts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eWorking altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m or less Do not use the PLC under pressure higher than the atmospheric pressure. Doing so may damage the PLC.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eFX3S, FX3G (Ver. 1.20 or later), FX3U (Ver. 2.61 or later), FX3GC, FX3UC (Ver. 2.61 or later) The FX3S-CNV-ADP is required to connect the FX3S PLC. The FX3G-CNV-ADP is required to connect the FX3G PLC\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137177702653,"sku":"FX3U-3A-ADP","price":97.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/221549-1.jpg?v=1742537122"},{"product_id":"aj65sbtb2n16r","title":"Mitsubishi AJ65SBTB2N16R | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi AJ65SBTB2N16R\u003c\/h2\u003e\n\u003cp\u003eAJ65SBTB2N-16R\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cp\u003eContact output: 16 points, 24 V DC\/240 V AC, 2 A\/point, 8 A\/common, response time: 12 ms, 16 points\/common, 2-wire terminal block type, number of occupied stations: 1 station | Conformance: UL cUL CE(EMC) CE(LVD) CE(RoHS) KC(EMC)\u003c\/p\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eContact output: 16 points, 24 V DC\/240 V AC, 2 A\/point, 8 A\/common, response time: 12 ms, 16 points\/common, 2-wire terminal block type, number of occupied stations: 1 station\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137177800957,"sku":"AJ65SBTB2N16R","price":68.22,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/T3nUDR6FiRPZZ22Cc8w0jtXCA02GhMT0lH03BiTZl6axTotGZ7A33t8y8YtJ.jpg?v=1742537124"},{"product_id":"fx3u-usb-bd","title":"Mitsubishi FX3U-USB-BD | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi FX3U-USB-BD\u003c\/h2\u003e\n\u003cp\u003eFX3U-USB-BD\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cp\u003eUSB communication (FX3UC PLC can be installed only on FX3UC-32MT-LT(-2)) | Conformance: CE(EMC) CE(RoHS) KC(EMC) LR NK DNV ABS RINA BV KR\u003c\/p\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eConnect with a personal computer equipped with a USB interface to conduct programming or monitoring. (1) No. of channels: 1 (2) Insulation: Yes (3) Maximum transmission distance: 5 m at most (Included cable is 3 m.) (4) Control method: Programming communication\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137177866493,"sku":"FX3U-USB-BD","price":21.07,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/165284.jpg?v=1742537127"},{"product_id":"r60adi8","title":"Mitsubishi R60ADI8 | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi R60ADI8\u003c\/h2\u003e\n\u003cp\u003eMELSEC iQ-R Series R60ADI8\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInput specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e  \/ 8 points (8 channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNumber of analog input points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0...20 mA DC (input resistance 250 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16-bit signed binary value (-32768...32767)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDigital output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital output value (resolution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eI\/O characteristics, resolution - Input range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0...32000 (625.0 nA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eI\/O characteristics, resolution - Current input - 0...20 mA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0...32000 (500.0 nA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eI\/O characteristics, resolution - Current input - 4...20 mA\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-8000...32000 (500.0 nA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eI\/O characteristics, resolution - Current input - 4...20 mA (extended mode)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-32000...32000 (190.7 nA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eI\/O characteristics, resolution - Current input - User range setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithin ±0.1 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAccuracy (accuracy relative to maximum value of the digital output value) - Ambient temperature: 25±5 ﾟC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithin ±0.3 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAccuracy (accuracy relative to maximum value of the digital output value) - Ambient temperature: 0...55 ﾟC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 µs\/channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eA\/D conversion speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAbsolute maximum input - Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e  \/ Between I\/O terminals and programmable controller power supply: Photocoupler Between input channels: Non-isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eCommon specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBetween I\/O terminals and programmable controller power supply: 500 V AC rms for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eIsolation method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBetween I\/O terminals and programmable controller power supply: 500 V DC 10 MΩ or higher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDielectric withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18-point terminal block (M3 screw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 points (I\/O assignment: Intelligent 16 points)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal interface -  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.22 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNumber of occupied I\/O points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e106 mm (base unit mounting side: 98 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInternal current consumption (5 V DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal dimensions - Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e131 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal dimensions - Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.17 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eGeneral specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRefer to the general specifications of the CPU module or remote head module.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137177932029,"sku":"R60ADI8","price":207.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/W1siZiIsIjIwMjAvMDIvMDQvMTQvNDAvMTcvZTA3NTc1ZjAtYzkxNi00OTQ2LWI4ODMtMmIzMWZkMzhiYmNjL3I2MGFkNC5qcGciXSxbInAiLCJ0aHVtYiIsIjQwMHg0MDBcdTAwM2UiXV0.jpg?v=1742537129"},{"product_id":"hgkr13","title":"Mitsubishi HGKR13 | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi HGKR13\u003c\/h2\u003e\n\u003cp\u003eHG-KR13\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cp\u003eServo motor, low inertia, small capacity, rated speed of 3000 r\/min, rated output of 0.1 kW, standard servo motor | Conformance: UL CSA CE(EMC) CE(LVD) CE(RoHS) UKCA ChinaRoHS\u003c\/p\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eSuitable for general industrial machines. (Example: X-Y tables, semiconductor manufacturing systems, etc.)\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137178030333,"sku":"HGKR13","price":93.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/248652.jpg?v=1742537132"},{"product_id":"q68adi","title":"Mitsubishi Q68ADI | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi Q68ADI\u003c\/h2\u003e\n\u003cp\u003eQ68ADI\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cp\u003e8 channels, input: 0...20 mA DC, output (resolution): 0...4000, -4000...4000, 0...12000, -12000...12000, conversion speed: 80 μs\/channel, 18-point terminal block | Conformance: UL cUL CE(EMC) CE(RoHS) KC(EMC) LR NK DNV ABS RINA BV\u003c\/p\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003e8 channels, input: 0...20 mA DC, output (resolution): 0...4000, -4000...4000, 0...12000, -12000...12000, conversion speed: 80 μs\/channel, 18-point terminal block\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137178095869,"sku":"Q68ADI","price":160.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/k2BK5Efx511FIQiI0swcLrVAmlBsdebmAAHknGB54ryrJ3hJG3Ic8pSChtG2.jpg?v=1742537134"},{"product_id":"qj71mt91","title":"Mitsubishi QJ71MT91 | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi QJ71MT91\u003c\/h2\u003e\n\u003cp\u003eMELSEC-Q Series QJ71MT91\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTransmission specifications - Data transmission speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100BASE-TX: 100 Mbps 10BASE-T: 10 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTransmission specifications - Flow control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100BASE-TX: None(Full-duplex), Back pressure congestion control(Half-duplex) 10BASE-T: Back pressure congestion control(Half-duplex)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTransmission specifications - Transmission method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase band\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTransmission specifications - Maximum node-to-node distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTransmission specifications - Maximum segment length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTransmission specifications - Number of cascaded connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaximum 4 stages (10BASE-T)\/Maximum 2 stages (100BASE-TX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTransmission specifications - Maximum number of connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTransmission specifications - Number of routers that can be set\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 default router + any 8 routers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTransmission specifications - Connector applicable to external wiring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaster function - Automatic communication function - Number of slaves\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 slaves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaster function - Automatic communication function - Function (for send)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7 functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaster function - Automatic communication function - Input area size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4K words\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaster function - Automatic communication function - Output area size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4K words\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaster function - Communication by dedicated instructions - Number of instructions that can be executed concurrently\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 8 instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaster function - Communication by dedicated instructions - Function (for send)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMBRW instruction: 9 functions MBREQ instruction: 19 functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaster function - Communication by dedicated instructions - Input area size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaximum 253 bytes per instruction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaster function - Communication by dedicated instructions - Output area size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaximum 253 bytes per instruction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSlave function - Automatic response function - Function (for receive)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSlave function - MODBUS ® device size - Coil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64K points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSlave function - MODBUS ® device size - Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64K points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSlave function - MODBUS ® device size - Input register\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64K points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSlave function - MODBUS ® device size - Holding register\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64K points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSlave function - MODBUS ® device size - Extended file register\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaximum 4086K points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSlave function - No. of simultaneously acceptable request messages\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eGX Developer connection function - Number of simultaneously connectable GX Developers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaximum 8 GX Developers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNumber of occupied I\/O points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 points (I\/O assignment: Intelligent 32 points)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInternal current consumption (5 V DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.52 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal dimensions - Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e98 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal dimensions - Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal dimensions - Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.11 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eGeneral specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRefer to the general specifications of the CPU module.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137178226941,"sku":"QJ71MT91","price":180.42,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/SY5uNkwOdySF8huAUhq5WibhuUK176WsHjzicqB8fABCAwIP3yNKsvo7k66W.jpg?v=1742537137"},{"product_id":"aj65sbtb116dt","title":"Mitsubishi AJ65SBTB116DT | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi AJ65SBTB116DT\u003c\/h2\u003e \u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e AJ65SBTB116DT\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eMitsubishi Communication Module\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eMitsubishi Electric industrial automation product. Japanese quality, designed for reliable motion control and factory automation applications.\u003c\/p\u003e \u003ch3\u003eSpecifications:\u003c\/h3\u003e \u003ctable\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eType:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003ePLC Communication Module\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eProduct Category:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eCommunication\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eProduct Series:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eMitsubishi QJ71\/RJ71\/AJ Series\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eFunctions:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eNetwork Communication, Data Exchange\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eCommunication Protocols:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eEtherNet\/IP, CC-Link IE, Modbus, PROFIBUS, DeviceNet\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eRecommended Use:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003ePLC Networking, SCADA Integration\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eSuitable Space:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eControl Cabinet\u003c\/td\u003e \u003c\/tr\u003e \u003c\/table\u003e \u003ch3\u003eCompatibility:\u003c\/h3\u003e \u003cp\u003eMitsubishi products support MELSEC PLC platforms (FX, Q, iQ-R series) and MELSERVO servo systems. Compatible with CC-Link, CC-Link IE, EtherNet\/IP, and SSCNET networks.\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137178292477,"sku":"AJ65SBTB116DT","price":45.96,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/AJ65SBTB1-16DT.jpg?v=1784944103"},{"product_id":"fr-a840-00620-2-60","title":"Mitsubishi FR-A840-00620-2-60 | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi FR-A840-00620-2-60\u003c\/h2\u003e\n\u003cp\u003eInverters-FREQROL FR-A840-00620-2-60\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThree-phase 400 V class Standard model RS-485 model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eModel name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-A840-00620-2-60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInverter capacity (kW)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eApplicable motor capacity (kW) *1 - SLD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eApplicable motor capacity (kW) *1 - LD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eApplicable motor capacity (kW) *1 - ND\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eApplicable motor capacity (kW) *1 - HD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput - Rated capacity (kVA) *3 - SLD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput - Rated capacity (kVA) *3 - LD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e43.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput - Rated capacity (kVA) *3 - ND\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e34.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput - Rated capacity (kVA) *3 - HD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e29.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput - Rated current (A) - SLD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e62.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput - Rated current (A) - LD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e57.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput - Rated current (A) - ND\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e44.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput - Rated current (A) - HD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e38.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput - Overload current rating *4 - SLD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 % 60 s, 120 % 3 s (inverse-time characteristics) at surrounding air temperature of 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput - Overload current rating *4 - LD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 % 60 s, 150 % 3 s (inverse-time characteristics) at surrounding air temperature of 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput - Overload current rating *4 - ND\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 % 60 s, 200 % 3 s (inverse-time characteristics) at surrounding air temperature of 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput - Overload current rating *4 - HD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 % 60 s, 250 % 3 s (inverse-time characteristics) at surrounding air temperature of 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput - Voltage *5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThree-phase 380 to 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput - Regenerative braking - Brake transistor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput - Regenerative braking - Maximum brake torque (ND reference)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 % torque, continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply - Rated input AC voltage and frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThree-phase 380 to 500 V, 50\/60 Hz *10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply - Permissible AC voltage fluctuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e323 to 550 V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply - Permissible frequency fluctuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply - Rated input current (A) without DC reactor *7 - SLD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e76.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply - Rated input current (A) without DC reactor *7 - LD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply - Rated input current (A) without DC reactor *7 - ND\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply - Rated input current (A) without DC reactor *7 - HD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply - Rated input current (A) with DC reactor *7 - SLD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e62.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply - Rated input current (A) with DC reactor *7 - LD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e57.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply - Rated input current (A) with DC reactor *7 - ND\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e44.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply - Rated input current (A) with DC reactor *7 - HD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e38.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply - Power supply capacity (kVA) without DC reactor *8 - SLD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e59.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply - Power supply capacity (kVA) without DC reactor *8 - LD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e57.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply - Power supply capacity (kVA) without DC reactor *8 - ND\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e43.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply - Power supply capacity (kVA) without DC reactor *8 - HD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply - Power supply capacity (kVA) with DC reactor *8 - SLD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply - Power supply capacity (kVA) with DC reactor *8 - LD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e43.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply - Power supply capacity (kVA) with DC reactor *8 - ND\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e34.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply - Power supply capacity (kVA) with DC reactor *8 - HD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e29.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProtective structure - IEC 60529 *9\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eCooling system\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eForced air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eApprox. mass (kg)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - Control method - Common\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSoft-PWM control\/High carrier frequency PWM control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - Control method - Induction motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelectable among V\/F control, Advanced magnetic flux vector control, Real sensorless vector control, and Vector control *12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - Control method - PM motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelectable among PM sensorless vector control, and Vector control *12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - Output frequency range - Induction motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 to 590 Hz (The upper-limit frequency is 400 Hz under Advanced magnetic flux vector control, Real sensorless vector control, and Vector control *12 .)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - Output frequency range - PM motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 to 400 Hz (not operable at a frequency higher than the maximum motor frequency)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - Frequency setting and resolution - Analog input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.015 Hz\/60 Hz at 0 to 10 V\/12 bits (terminals 2 and 4) 0.03 Hz\/60 Hz at 0 to 5 V\/11 bits or 0 to 20 mA\/11 bits (terminals 2 and 4), at 0 to ±10 V\/12 bits (terminal 1) 0.06 Hz\/60 Hz at 0 to ±5 V\/11 bits (terminal 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - Frequency setting and resolution - Digital input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - Frequency accuracy - Analog input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithin ±0.2 % of the maximum output frequency (25 °C±10 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - Frequency accuracy - Digital input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 % or less of the set output frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - Voltage\/frequency characteristics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase frequency can be set from 0 to 590 Hz. Constant-torque\/variable-torque pattern or adjustable 5 points V\/F can be selected.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - Starting torque - Induction motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThe following is the specifications for the ND rating. 30 % or less at 1 Hz, 30 % at 3 Hz, 80 % at 6 Hz (V\/F control) 150 % at 0.5 Hz (Advanced magnetic flux vector control) 200 % at 0.3 Hz (0.4K to 3.7K), 150 % at 0.3 Hz (5.5K or higher) (Real sensorless vector control) 200 % at 0 Hz (0.4K to 3.7K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - Torque boost\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual torque boost (induction motor only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - Acceleration\/deceleration time setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 3600 s (acceleration and deceleration can be set individually), linear or S-pattern acceleration\/deceleration mode, backlash countermeasures acceleration\/deceleration modes are available.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - DC injection brake - Induction motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation frequency (0 to 120 Hz), operation time (0 to 10 s), operation voltage (0 to 30 %) variable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - DC injection brake - PM motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation time (0 to 10 s) variable. Operating voltage (operating current) fixed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - Stall prevention operation level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eActivation range of stall prevention operation (SLD rating : 0 to 120 %, LD rating : 0 to 150 %, ND rating : 0 to 220 %, HD rating : 0 to 280 %). Whether to use the stall prevention or not can be selected. (V\/F control, Advanced magnetic flux vector control)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - Torque limit level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTorque limit value can be set (0 to 400 % variable). (Real sensorless vector control, Vector control *12 , PM sensorless vector control)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOperation - Frequency setting signal - Number of analog input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOperation - Frequency setting signal - Specification of analog input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminals 2 and 4 : 0 to 10 V\/0 to 5 V\/4 to 20 mA (0 to 20 mA) Terminal 1 : -10 to +10 V\/-5 to +5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOperation - Frequency setting signal - Digital input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput using the setting dial of the operation panel or parameter unit. Input of four-digit BCD (Binary-coded decimal) or 16-bit binary (when the option FR-A8AX is installed).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOperation - Start signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eForward and reverse rotation or start signal automatic self-holding input (3-wire input) can be selected.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOperation - Input signal - Number of input signal (Contact input)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOperation - Input signal - Pulse train input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 k pulses\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOperation - Input signal - Input terminal function selectable signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLow-speed operation command, Middle-speed operation command, High-speed operation command, Second function selection, Terminal 4 input selection, Jog operation selection, Selection of automatic restart after instantaneous power failure\/flying start, Output stop, Start self-holding selection, Forward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOperation - Operational function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaximum and minimum frequency settings, Multi-speed operation, Acceleration\/deceleration pattern, Thermal protection, DC injection brake, Starting frequency, JOG operation, Output stop (MRS), Stall prevention, Regeneration avoidance, Increased magnetic excitation deceleration, DC feeding, Frequency \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOperation - Output signal - Number of output signal (Open collector output)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOperation - Output signal - Number of output signal (Relay output)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOperation - Output signal - Output terminal function selectable signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInverter running, Up to frequency, Instantaneous power failure\/undervoltage, Overload warning, Output frequency detection, Fault The signal to be output can be changed using Pr.190 to Pr.196 (Output terminal function selection). Fault codes (4 bits) of the inverter can be output from the open collec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOperation - Output signal - Pulse train output (FM type inverter)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 k pulses\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eIndication - For indication on external meters - Number of output signal for indication on external meters\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eIndication - For indication on external meters - Pulse train output (FM type inverter)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax. 2.4 kHz via one terminal (for the indication of inverter output frequency). The item for monitoring can be changed using Pr.54 FM\/CA terminal function selection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eIndication - For indication on external meters - Current output (CA type inverter)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax. 20 mA DC via one terminal (for the indication of inverter output frequency). The item for monitoring can be changed using Pr.54 FM\/CA terminal function selection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eIndication - For indication on external meters - Voltage output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax. 10 V DC via one terminal (for the indication of inverter output frequency). The item for monitoring can be changed using Pr.158 AM terminal function selection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eIndication - Operation panel - Status monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOutput frequency, output current, output voltage, and frequency setting value are monitored. The item for monitoring can be changed using Pr.52 Operation panel main monitor selection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eIndication - Operation panel - Fault monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWhen a protective function is activated, a fault indication is displayed and the output voltage, output current, output frequency, cumulative energization time, date (year, month, day) and time at the occurrence of the fault are stored. Each fault is recorded and the last 8 records can be displayed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProtective\/warning function - Protective function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOvercurrent trip during acceleration, Overcurrent trip during constant speed, Overcurrent trip during deceleration or stop, Regenerative overvoltage trip during acceleration, Regenerative overvoltage trip during constant speed, Regenerative overvoltage trip during deceleration or stop, Inverter over\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProtective\/warning function - Warning function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFan alarm, Stall prevention (overcurrent), Stall prevention (overvoltage), Regenerative brake pre-alarm *14 , Electronic thermal relay function pre-alarm, PU stop, Speed limit indication *14 , Parameter copy, Safety stop, Maintenance timer *14 , USB host error, Home position return setting error *14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment - Surrounding air temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10 °C to +50 °C (non-freezing) (LD, ND, HD ratings) -10 °C to +40 °C (non-freezing) (SLD rating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment - Surrounding air humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 % RH or less (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment - Storage temperature *15\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 °C to +65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment - Ambience\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndoors (free from corrosive gas, flammable gas, oil mist, dust and dirt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment - Altitude\/vibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaximum 2500 m *16 , 5.9 m\/s 2 or less *17 at 10 to 55 Hz in X, Y, and Z directions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNetwork\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-485 : Mitsubishi inverter protocol, MODBUS RTU Option unit : CC-Link IE TSN, CC-Link IE Field Network, CC-Link, SSCNETIII(\/H), DeviceNet, PROFIBUS-DPV0, FL remote, EtherCAT, EtherNet\/IP, PROFINET, PROFIBUS-DPV1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137178358013,"sku":"FR-A840-00620-2-60","price":1100.47,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/297576.jpg?v=1742537141"},{"product_id":"fr-f840-00470-2-60","title":"Mitsubishi FR-F840-00470-2-60 | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi FR-F840-00470-2-60\u003c\/h2\u003e\n\u003cp\u003eInverters-FREQROL FR-F840-00470-2-60\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-F800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThree-phase 400 V class Standard model RS-485 model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eModel name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFR-F840-00470-2-60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInverter capacity (kW)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eApplicable motor capacity (kW) *1 - SLD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eApplicable motor capacity (kW) *1 - LD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput - Rated capacity (kVA) *2 - SLD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput - Rated capacity (kVA) *2 - LD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput - Rated current (A) - SLD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput - Rated current (A) - LD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e43.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput - Overload current rating *3 - SLD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 % 60 s, 120 % 3 s (inverse-time characteristics) at surrounding air temperature of 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput - Overload current rating *3 - LD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 % 60 s, 150 % 3 s (inverse-time characteristics) at surrounding air temperature of 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput - Voltage *4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThree-phase 380 to 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply - Rated input AC voltage and frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThree-phase 380 to 500 V, 50\/60 Hz *8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply - Permissible AC voltage fluctuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e323 to 550 V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply - Permissible frequency fluctuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply - Rated input current (A) without DC reactor *5 - SLD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e58.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply - Rated input current (A) without DC reactor *5 - LD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e53.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply - Rated input current (A) with DC reactor *5 - SLD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply - Rated input current (A) with DC reactor *5 - LD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e43.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply - Power supply capacity (kVA) without DC reactor *6 - SLD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e44.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply - Power supply capacity (kVA) without DC reactor *6 - LD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e41.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply - Power supply capacity (kVA) with DC reactor *6 - SLD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply - Power supply capacity (kVA) with DC reactor *6 - LD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProtective structure - IEC 60529 *7\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eCooling system\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eForced air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eApprox. mass (kg)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - Control method - Common\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSoft-PWM control\/High carrier frequency PWM control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - Control method - Induction motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelectable among V\/F control, and Advanced magnetic flux vector control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - Control method - PM motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePM motor control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - Output frequency range - Induction motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 to 590 Hz (The upper-limit frequency is 400 Hz under Advanced magnetic flux vector control.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - Output frequency range - PM motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 to 400 Hz (not operable at a frequency higher than the maximum motor frequency)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - Frequency setting and resolution - Analog input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.015 Hz\/60 Hz at 0 to 10 V\/12 bits (terminals 2 and 4) 0.03 Hz\/60 Hz at 0 to 5 V\/11 bits or 0 to 20 mA\/11 bits (terminals 2 and 4), at 0 to ±10 V\/12 bits (terminal 1) 0.06 Hz\/60 Hz at 0 to ±5 V\/11 bits (terminal 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - Frequency setting and resolution - Digital input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - Frequency accuracy - Analog input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWithin ±0.2 % of the maximum output frequency (25 °C ±10 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - Frequency accuracy - Digital input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 % or less of the set output frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - Voltage\/frequency characteristics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase frequency can be set from 0 to 590 Hz. Constant-torque\/variable-torque pattern or adjustable 5 points V\/F can be selected.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - Starting torque - Induction motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThe following is the specifications for the LD rating. 30 % or less at 1 Hz, 30 % at 3 Hz, 80 % at 6 Hz (V\/F control) 120 % at 0.5 Hz (Advanced magnetic flux vector control)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - Starting torque - PM motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThe following is the specifications for the LD rating. 50 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - Torque boost\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual torque boost (induction motor only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - Acceleration\/deceleration time setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 3600 s (acceleration and deceleration can be set individually), linear or S-pattern acceleration\/deceleration mode, backlash countermeasures acceleration\/deceleration modes are available.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - DC injection brake - Induction motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation frequency (0 to 120 Hz), operation time (0 to 10 s), operation voltage (0 to 30 %) variable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - DC injection brake - PM motor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation time (0 to 10 s) variable. Operating voltage (operating current) fixed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl - Stall prevention operation level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eActivation range of stall prevention operation (SLD rating : 0 to 120 %, LD rating : 0 to 150 %). Whether to use the stall prevention or not can be selected. (V\/F control, Advanced magnetic flux vector control)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOperation - Frequency setting signal - Number of analog input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOperation - Frequency setting signal - Specification of analog input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminals 2 and 4 : 0 to 10 V\/0 to 5 V\/4 to 20 mA (0 to 20 mA) Terminal 1 : -10 to +10 V\/-5 to +5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOperation - Frequency setting signal - Digital input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInput using the setting dial of the operation panel or parameter unit. Input of four-digit BCD (Binary-coded decimal) or 16-bit binary (when the option FR-A8AX is installed).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOperation - Start signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eForward and reverse rotation or start signal automatic self-holding input (3-wire input) can be selected.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOperation - Input signal - Number of input signal (Contact input)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOperation - Input signal - Pulse train input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 k pulses\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOperation - Input signal - Input terminal function selectable signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLow-speed operation command, Middle-speed operation command, High-speed operation command, Second function selection, Terminal 4 input selection, Jog operation selection, Output stop, Start self-holding selection, Forward rotation command, Reverse rotation command, Inverter reset The signal to be in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOperation - Operational function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaximum and minimum frequency settings, Multi-speed operation, Acceleration\/deceleration pattern, Thermal protection, DC injection brake, Starting frequency, JOG operation, Output stop (MRS), Stall prevention, Regeneration avoidance, Increased magnetic excitation deceleration, DC feeding, Frequency \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOperation - Output signal - Number of output signal (Open collector output)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOperation - Output signal - Number of output signal (Relay output)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOperation - Output signal - Output terminal function selectable signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInverter running, Up to frequency, Instantaneous power failure\/undervoltage, Overload warning, Output frequency detection, Fault The signal to be output can be changed using Pr.190 to Pr.196 (Output terminal function selection). Fault codes (4 bits) of the inverter can be output from the open collec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOperation - Output signal - Pulse train output (FM type inverter)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 k pulses\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eIndication - For indication on external meters - Number of output signal for indication on external meters\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eIndication - For indication on external meters - Pulse train output (FM type inverter)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax. 2.4 kHz via one terminal (for the indication of inverter output frequency). The item for monitoring can be changed using Pr.54 FM\/CA terminal function selection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eIndication - For indication on external meters - Current output (CA type inverter)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax. 20 mA DC via one terminal (for the indication of inverter output frequency). The item for monitoring can be changed using Pr.54 FM\/CA terminal function selection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eIndication - For indication on external meters - Voltage output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax. 10 V DC via one terminal (for the indication of inverter output frequency). The item for monitoring can be changed using Pr.158 AM terminal function selection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eIndication - Operation panel - Status monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOutput frequency, output current, output voltage, and frequency setting value are monitored. The item for monitoring can be changed using Pr.52 Operation panel main monitor selection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eIndication - Operation panel - Fault monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWhen a protective function is activated, a fault indication is displayed and the output voltage, output current, output frequency, cumulative energization time, date (year, month, day) and time at the occurrence of the fault are stored. Each fault is recorded and the last 8 records can be displayed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProtective\/warning function - Protective function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOvercurrent trip during acceleration, Overcurrent trip during constant speed, Overcurrent trip during deceleration or stop, Regenerative overvoltage trip during acceleration, Regenerative overvoltage trip during constant speed, Regenerative overvoltage trip during deceleration or stop, Inverter over\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProtective\/warning function - Warning function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFan alarm, Stall prevention (overcurrent), Stall prevention (overvoltage), Electronic thermal relay function pre-alarm, PU stop, Parameter copy, Safety stop, Maintenance timer *9 , USB host error, Operation panel lock *9 , Password locked *9 , Parameter write error, Copy operation error, 24 V extern\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment - Surrounding air temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10 °C to +50 °C (non-freezing) (LD rating) -10 °C to +40 °C (non-freezing) (SLD rating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment - Surrounding air humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 % RH or less (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment - Storage temperature *10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 °C to +65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment - Ambience\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndoors (free from corrosive gas, flammable gas, oil mist, dust and dirt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment - Altitude\/vibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaximum 2500 m *12 , 5.9 m\/s 2 or less *11 at 10 to 55 Hz in X, Y, and Z directions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNetwork\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-485 : Mitsubishi inverter protocol, MODBUS RTU, BACnet MS\/TP Option unit : CC-Link IE TSN, CC-Link IE Field Network, CC-Link, DeviceNet, PROFIBUS-DPV0, LONWORKS, FL remote, EtherCAT, EtherNet\/IP, PROFINET, PROFIBUS-DPV1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137178423549,"sku":"FR-F840-00470-2-60","price":997.56,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/307220.jpg?v=1742537144"},{"product_id":"fx2n-16eyt","title":"Mitsubishi FX2N-16EYT | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi FX2N-16EYT\u003c\/h2\u003e\n\u003cp\u003eMELSEC-F Series FX2N-16EYT\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eApplicable PLC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFX1N, FX3G, FX2N, FX3U, FX1NC, FX3GC, FX2NC, FX3UC [Connecting to the connector-type PLC] The FX2NC-CNV-IF is required to connect the FX1NC, FX2NC. The FX2NC-CNV-IF or FX3UC-1PS-5V is required to connect the FX3GC, FX3UC.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMass (weight)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e  \/ PLC internal power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eRated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e  \/ 16 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVertical terminal block (M3 screws)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of output points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTransistor\/sink output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput connection type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 V to 30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 A\/1 point The total load current per common terminal should be the following value. ・4 output points\/common terminal: 0.8 A or less ・8 output points\/common terminal: 1.6 A or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal power supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 W\/24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMax. load - Resistance load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mA\/30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMax. load - Inductive load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 V or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOpen circuit leakage current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 ms or less for 200 mA (at 24 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eON voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 ms or less for 200 mA (at 24 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eResponse time - OFF→ON\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhotocoupler insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eResponse time - ON→OFF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWhen photocoupler is driven, LED on panel is lit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 55°C when operating and -25 to 75°C when stored\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAmbient humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 to 95%RH (no condensation) when operating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eVibration resistance - Installed on DIN rail - Frequency: 10 to 57 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHalf amplitude: 0.035mmnSweep Count for X, Y, Z: 10 times (80 min in each direction) The criterion is shown in IEC61131-2.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eVibration resistance - Installed on DIN rail - Frequency: 57 to 150 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAcceleration: 4.9 m\/s 2 Sweep Count for X, Y, Z: 10 times (80 min in each direction) The criterion is shown in IEC61131-2.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eVibration resistance - Direct installing - Frequency: 10 to 57 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHalf amplitude: 0.075 mm Sweep Count for X, Y, Z: 10 times (80 min in each direction) The criterion is shown in IEC61131-2.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eVibration resistance - Direct installing - Frequency: 57 to 150 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAcceleration: 9.8 m\/s 2 Sweep Count for X, Y, Z: 10 times (80 min in each direction) The criterion is shown in IEC61131-2.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eShock resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e147 m\/s 2 Acceleration, Action time: 11 ms, 3 times by half-sine pulse in each direction X, Y, and Z The criterion is shown in IEC61131-2.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNoise resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBy noise simulator at noise voltage of 1,000 Vp-p, noise width of 1 μs, rise time of 1 ns and period of 30 to 100 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDielectric withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBetween output terminal (transistor) of extension output block and ground terminal: 500 V AC for 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBetween output terminal (transistor) of extension output block and ground terminal: 5 MΩ or higher by 500 V DC insulation resistance tester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eWorking atmosphere\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFree from corrosive or flammable gas and excessive conductive dusts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eWorking altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m or less Do not use the PLC under pressure higher than the atmospheric pressure. Doing so may damage the PLC.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eFX1N, FX3G, FX2N, FX3U, FX1NC, FX3GC, FX2NC, FX3UC [Connecting to the connector-type PLC] The FX2NC-CNV-IF is required to connect the FX1NC, FX2NC. The FX2NC-CNV-IF or FX3UC-1PS-5V is required to conn\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137178521853,"sku":"FX2N-16EYT","price":26.63,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/F3209115-01.jpg?v=1742537146"},{"product_id":"r08cpu","title":"Mitsubishi R08CPU | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi R08CPU\u003c\/h2\u003e\n\u003cp\u003eR08CPU\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cp\u003eNumber of I\/O points: 4096, program capacity: 80K steps, basic operation processing speed (LD X0): 0.98 ns, program memory capacity: 320K bytes, external interface: USB\/Ethernet | Conformance: UL cUL CE(EMC) CE(RoHS) KC(EMC) LR NK DNV ABS RINA BV\u003c\/p\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eNumber of I\/O points: 4096, program capacity: 80K steps, basic operation processing speed (LD X0): 0.98 ns, program memory capacity: 320K bytes, external interface: USB\/Ethernet\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137178620157,"sku":"R08CPU","price":523.42,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/W1siZiIsIjIwMjAvMDIvMDQvMTQvMzkvNTUvZjFmZTNmNDYtNDkwYi00MzM3LTg3MDUtZWViZWRiZjA2OWZiL3IxMjBjcHUuanBnIl0sWyJwIiwidGh1bWIiLCI0MDB4NDAwXHUwMDNlIl1d.jpg?v=1742537149"},{"product_id":"rj71en71","title":"Mitsubishi RJ71EN71 | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi RJ71EN71\u003c\/h2\u003e\n\u003cp\u003eMELSEC iQ-R Series RJ71EN71\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEthernet specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e  \/ 1 Gbps\/100 Mbps\/10 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTransmission specifications - Data transmission speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000BASE-T: Full-duplex 100BASE-TX: Full-duplex\/half-duplex 10BASE-T: Full-duplex\/half-duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTransmission specifications - Communication mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRJ45 (AUTO MDI\/MDI-X)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTransmission specifications - Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase band\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTransmission specifications - Maximum frame size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAvailable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTransmission specifications - Jumbo frame\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 m (length between hub and node)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTransmission specifications - Maximum segment length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIPv4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTransmission specifications - IP version\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e128 connections (connections usable on a program)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSending\/receiving data storage memory - Number of simultaneously open connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5K words × 16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSending\/receiving data storage memory - Socket communications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6K words × 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSending\/receiving data storage memory - Random access buffer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e  \/ 32K points (32768 points, 4K bytes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eCC-Link IE Controller Network specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e128K points (131072 points, 256K bytes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of link points per network - LB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8K points (8192 points, 1K bytes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of link points per network - LW\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8K points (8192 points, 1K bytes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of link points per network - LX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16K points (16384 points, 2K bytes), extended mode: 32K points (32768 points, 4K bytes))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of link points per network - LY\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16K points (16384 points, 2K bytes), extended mode: 128K points (131072 points, 256K bytes))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of link points per station - LB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8K points (8192 points, 1K bytes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of link points per station - LW\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8K points (8192 points, 1K bytes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of link points per station - LX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaximum 1920 bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of link points per station - LY\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTransient transmission capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLine topology, star topology (Coexistence of line topology and star topology is possible.), and ring topology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eCommunication speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEthernet cable which satisfies 1000BASE-T standard: Category 5e or higher, straight cable (double shielded, STP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNetwork topology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 m (compliant with ANSI\/TIA\/EIA-568-B (Category 5e))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eCommunication cable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLine topology: 11900 m (when 120 stations are connected) Star topology: Depends on the system configuration Ring topology: 12000 m (when 120 stations are connected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum station-to-station distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 levels maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOverall cable distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 stations (control station: 1, normal station: 119)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNumber of cascade connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e239\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of connectable stations\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of networks\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToken passing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of groups\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRJ45 connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eCommunication method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e  \/ 16K points (16384 points, 2K bytes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eApplicable connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16K points (16384 points, 2K bytes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eCC-Link IE Field Network specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8K points (8192 points, 16K bytes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of link points per network - RX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8K points (8192 points, 16K bytes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of link points per network - RY\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16K points (16384 points, 2K bytes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of link points per network - RWr\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16K points (16384 points, 2K bytes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of link points per network - RWw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8K points (8192 points, 16K bytes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of link points per station - Manager station - RX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8K points (8192 points, 16K bytes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of link points per station - Manager station - RY\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2K points (2048 points, 256K bytes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of link points per station - Manager station - RWr\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2K points (2048 points, 256K bytes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of link points per station - Manager station - RWw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1K points (1024 points, 2K bytes) 256 points (512 bytes) when communication mode is \"High-Speed\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of link points per station - Local station - RX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1K points (1024 points, 2K bytes) 256 points (512 bytes) when communication mode is \"High-Speed\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of link points per station - Local station - RY\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaximum 1920 bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of link points per station - Local station - RWr\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of link points per station - Local station - RWw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLine topology, star topology (Coexistence of line topology and star topology is possible.), and ring topology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eHardware specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNumber of occupied I\/O points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInternal current consumption (5 V DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.17 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eGeneral specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRefer to the general specifications of the CPU module or remote head module.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137178685693,"sku":"RJ71EN71","price":310.46,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/W1siZiIsIjIwMjAvMDIvMDQvMTQvNDAvMjYvODEyOTQ3MjYtNTQ0Mi00NDk0LTllOGItMTg4NGE4NzQ2N2VhL3JqNzFlbjcxLmpwZyJdLFsicCIsInRodW1iIiwiNDAweDQwMFx1MDAzZSJdXQ.jpg?v=1742537151"},{"product_id":"rj71gf11t2","title":"Mitsubishi RJ71GF11-T2 | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi RJ71GF11-T2\u003c\/h2\u003e\n\u003cp\u003eMELSEC iQ-R Series RJ71GF11-T2\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of link points per network - RX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16K points (16384 points, 2K bytes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of link points per network - RY\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16K points (16384 points, 2K bytes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of link points per network - RWr\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8K points (8192 points, 16K bytes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of link points per network - RWw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8K points (8192 points, 16K bytes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of link points per station - Manager station - RX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16K points (16384 points, 2K bytes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of link points per station - Manager station - RY\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16K points (16384 points, 2K bytes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of link points per station - Manager station - RWr\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8K points (8192 points, 16K bytes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of link points per station - Manager station - RWw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8K points (8192 points, 16K bytes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of link points per station - Local station - RX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2K points (2048 points, 256K bytes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of link points per station - Local station - RY\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2K points (2048 points, 256K bytes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of link points per station - Local station - RWr\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1K points (1024 points, 2K bytes) 256 points (512 bytes) when communication mode is \"High-Speed\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of link points per station - Local station - RWw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1K points (1024 points, 2K bytes) 256 points (512 bytes) when communication mode is \"High-Speed\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSafety communication function - Maximum number of safety connections per network\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1814 connections For the system with the SIL2 Process CPU: 120 connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSafety communication function - Maximum number of safety connections per station\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSafety communication function - Maximum number of safety connections per the same communication destination station\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 connection For the system with the SIL2 Process CPU: 32 connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSafety communication function - Maximum number of link points per safety connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003einput: 8 words output: 8 words\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTransient transmission capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaximum 1920 bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eCommunication speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNetwork topology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLine topology, star topology (Coexistence of line topology and star topology is possible.), and ring topology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eCommunication cable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEthernet cable which satisfies 1000BASE-T standard: Category 5e or higher, straight cable (double shielded, STP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum station-to-station distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 m (conforms to ANSI\/TIA\/EIA-568-B (Category 5e))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOverall cable distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLine topology: 12000 m (when 121 stations are connected) Star topology: Depends on the system configuration Ring topology: 12100 m (when 121 stations are connected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNumber of cascade connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 levels maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of connectable stations\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e121 stations (manager station: 1, device station: 120)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of networks\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e239\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eCommunication method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eToken passing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNumber of occupied I\/O points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInternal current consumption (5 V DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.82 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal dimensions - Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e106 mm (base unit mounting side: 98 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal dimensions - Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal dimensions - Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.17 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eGeneral specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRefer to the general specifications of the CPU module.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137178751229,"sku":"RJ71GF11-T2","price":167.13,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/W1siZiIsIjIwMjAvMDIvMDQvMTQvNDAvMjcvY2UyY2FlZGMtZGRjYS00OGZiLWIwZDUtYmNjMDczNTAyNjZkL3JqNzFnZjExLXQyLmpwZyJdLFsicCIsInRodW1iIiwiNDAweDQwMFx1MDAzZSJdXQ_2d36250f-66ea-4a5a-88ac-31434798.jpg?v=1742537153"},{"product_id":"ry40pt5p","title":"Mitsubishi RY40PT5P | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi RY40PT5P\u003c\/h2\u003e\n\u003cp\u003eMELSEC iQ-R Series RY40PT5P\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e  \/ Transistor output (source type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNumber of output points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\/24 V DC (allowable voltage range: 10.2...28.8 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eRated load voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 A\/point, Pilot Duty, 5 A\/common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum load current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCurrent is limited by the overload protection function.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum inrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mA or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eLeakage current at OFF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 V DC (TYP.) 0.5 A, 0.3 V DC (MAX.) 0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum voltage drop at ON\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 ms or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput response time - OFF to ON\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 ms or less (rated load, resistive load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput response time - ON to OFF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZener diode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSurge suppressor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eFuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAvailable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProtection function - Overheat protection function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAvailable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProtection function - Overload protection function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\/24 V DC (ripple ratio: within 5 %) (allowable voltage range: 10.2...28.8 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal power supply - Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 mA TYP. (at 24 V DC), 44 mA MAX. (at 24 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal power supply - Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 points\/common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput common terminal arrangement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e  \/ 510 V AC rms for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eCommon specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 MΩ or higher by insulation resistance tester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDielectric withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18-point terminal block (M3 screw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProtection degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 points (I\/O assignment: Output 16 points)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal interface -  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 mA (TYP. all points ON)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNumber of occupied I\/O points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e106 mm (base unit mounting side: 98 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInternal current consumption (5 V DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal dimensions - Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e131 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal dimensions - Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.16 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eGeneral specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRefer to the general specifications of the CPU module or remote head module.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eCurrent is limited by the overload protection function.\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137178816765,"sku":"RY40PT5P","price":106.84,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/W1siZiIsIjIwMjAvMDIvMDQvMTQvNDAvMTUvNjY1ZmQ0MDAtNGQ1OC00MzZmLWEwZGYtOWQ2ZDBhNGFkODllL3J5NDBwdDVwLmpwZyJdLFsicCIsInRodW1iIiwiNDAweDQwMFx1MDAzZSJdXQ_def9cd7a-b9b3-439b-83a3-a48c2753ab18.jpg?v=1742537156"},{"product_id":"qj71c24n","title":"Mitsubishi QJ71C24N | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi QJ71C24N\u003c\/h2\u003e\n\u003cp\u003eQJ71C24N\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cp\u003eRS-232: 1 channel, RS-422\/485: 1 channel, transmission speed: 230.4 kbps with 2 channels | Conformance: UL cUL CE(EMC) CE(RoHS) KC(EMC) LR NK DNV ABS RINA BV\u003c\/p\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eRS-232: 1 channel, RS-422\/485: 1 channel, transmission speed: 230.4 kbps with 2 channels\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137178915069,"sku":"QJ71C24N","price":47.57,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/GqPuuIBxJ4gxTV7w78FONeLixbqgl44JNJmLq6Mfcdlo6abWbaga74SLV7bf.jpg?v=1742537158"},{"product_id":"aj65sbtb116t","title":"Mitsubishi AJ65SBTB116T | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi AJ65SBTB116T\u003c\/h2\u003e \u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e AJ65SBTB116T\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eMitsubishi Communication Module\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eMitsubishi Electric industrial automation product. Japanese quality, designed for reliable motion control and factory automation applications.\u003c\/p\u003e \u003ch3\u003eSpecifications:\u003c\/h3\u003e \u003ctable\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eType:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003ePLC Communication Module\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eProduct Category:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eCommunication\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eProduct Series:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eMitsubishi QJ71\/RJ71\/AJ Series\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eFunctions:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eNetwork Communication, Data Exchange\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eCommunication Protocols:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eEtherNet\/IP, CC-Link IE, Modbus, PROFIBUS, DeviceNet\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eRecommended Use:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003ePLC Networking, SCADA Integration\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eSuitable Space:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eControl Cabinet\u003c\/td\u003e \u003c\/tr\u003e \u003c\/table\u003e \u003ch3\u003eCompatibility:\u003c\/h3\u003e \u003cp\u003eMitsubishi products support MELSEC PLC platforms (FX, Q, iQ-R series) and MELSERVO servo systems. Compatible with CC-Link, CC-Link IE, EtherNet\/IP, and SSCNET networks.\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137178980605,"sku":"AJ65SBTB116T","price":41.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/lPbNiXWBbOLan4XZdzRrg5jJqcNP4zwhgw1PkkpmFGIhMoX3EvKSyJB2sVzy.jpg?v=1742537161"},{"product_id":"a1sy10","title":"Mitsubishi A1SY10 | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi A1SY10\u003c\/h2\u003e \u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e A1SY10\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eMitsubishi PLC Module\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eMitsubishi Electric industrial automation product. Japanese quality, designed for reliable motion control and factory automation applications.\u003c\/p\u003e \u003ch3\u003eSpecifications:\u003c\/h3\u003e \u003ctable\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eType:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003ePLC Function Module\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eProduct Category:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003ePLCs\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eFunctions:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eAnalog I\/O, Temperature Control, High-Speed Counter\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eRecommended Use:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eProcess Control, Measurement\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eSuitable Space:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eControl Cabinet\u003c\/td\u003e \u003c\/tr\u003e \u003c\/table\u003e \u003ch3\u003eCompatibility:\u003c\/h3\u003e \u003cp\u003eMitsubishi products support MELSEC PLC platforms (FX, Q, iQ-R series) and MELSERVO servo systems. Compatible with CC-Link, CC-Link IE, EtherNet\/IP, and SSCNET networks.\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137179111677,"sku":"A1SY10","price":33.72,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/A1S-Y10.jpg?v=1784944125"},{"product_id":"q06udvcpu","title":"Mitsubishi Q06UDVCPU | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi Q06UDVCPU\u003c\/h2\u003e\n\u003cp\u003eMELSEC-Q Series Q06UDVCPU\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStored program cyclic operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eI\/O control mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRefresh mode (The direct access input\/output is available by specifying the direct access input\/output (DX, DY).)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProgramming language - Sequence control language\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRelay symbol language, logic symbolic language, MELSAP3 (SFC), MELSAP-L, function block and structured text (ST)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProcessing speed - Sequence instruction - LD X0\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.9 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProcessing speed - Sequence instruction - MOV D0 D1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.9 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eConstant scan\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5...2000 ms (setting is available in increments of 0.1 ms by parameter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProgram capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60K steps (240K bytes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMemory capacity - Program memory (drive 0)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240K bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMemory capacity - Standard RAM (drive 3) - Without an extended SRAM cassette\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e768K bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMemory capacity - Standard RAM (drive 3) - With an extended SRAM cassette\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCapacities of the memory in the module + extended SRAM cassette (The maximum capacity of an extended SRAM cassettes is 8M bytes.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMemory capacity - Standard ROM (drive 4)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1025.5K bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMemory capacity - CPU shared memory - QCPU standard memory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8K bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMemory capacity - CPU shared memory - Multiple CPU high speed transmission area\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32K bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of storable files - Program memory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e124\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of storable files - Memory card (SD) - SD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRoot directory: 512 (maximum) Subdirectory: 65534 (maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of storable files - Memory card (SD) - SDHC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRoot directory: 65535 (maximum) Subdirectory: 65534 (maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of storable files - Standard RAM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e323\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of storable files - Standard ROM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e256\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of intelligent function module parameters - Initial setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4096 parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of intelligent function module parameters - Refresh\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2048 parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNumber of I\/O device points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8192 points (X\/Y0...1FFF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNumber of I\/O points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4096 points (X\/Y0...FFF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - Internal relay (M)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15360 points (M0...15359) by default (changeable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - Latch relay (L)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8192 points (L0...8191) by default (changeable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - Link relay (B)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8192 points (B0...1FFF) by default (changeable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - Timer (T)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2048 points (T0...2047) by default (changeable) (Low-speed and high-speed timers available) Low-speed or high-speed is specified by an instruction. The measurement unit is set by parameter. (Low-speed timer: 1...1000 ms (in increments of 1 ms), default: 100 ms) (High-speed timer: 0.01...100 ms (in i\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - Retentive timer (ST)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 points by default (changeable) (Low-speed and high-speed retentive timers available) Low-speed or high-speed is specified by an instruction. The measurement unit is set by parameter. (Low-speed retentive timer: 1...1000 ms (in increments of 1 ms), default: 100 ms) (High-speed retentive timer: 0.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - Counter (C)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNormal counter: 1024 points (C0...1023) by default (changeable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - Data register (D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22528 points (D0...22527) by default (changeable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - Extended data register (D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 points by default (changeable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - Link register (W)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8192 points (W0...1FFF) by default (changeable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - Extended link register (W)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 points by default (changeable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - Annunciator (F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2048 points (F0...2047) by default (changeable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - Edge relay (V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2048 points (V0...2047) by default (changeable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - File register (R) - Without an extended SRAM cassette\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32768 points (R0...32767) (Maximum 393216 points are available by switching blocks.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - File register (R) - With Q4MCA-1MBS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32768 points (R0...32767) (Maximum 917504 points are available by switching blocks.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - File register (R) - With Q4MCA-2MBS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32768 points (R0...32767) (Maximum 1441792 points are available by switching blocks.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - File register (R) - With Q4MCA-4MBS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32768 points (R0...32767) (Maximum 2490368 points are available by switching blocks.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - File register (R) - With Q4MCA-8MBS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32768 points (R0...32767) (Maximum 4587520 points are available by switching blocks.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - File register (ZR) - Without an extended SRAM cassette\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e393216 points (ZR0...393215) (Blocks do not need to be switched.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - File register (ZR) - With Q4MCA-1MBS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e917504 points (ZR0...917503) (Blocks do not need to be switched.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - File register (ZR) - With Q4MCA-2MBS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1441792 points (ZR0...1441791) (Blocks do not need to be switched.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - File register (ZR) - With Q4MCA-4MBS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2490368 points (ZR0...2490367) (Blocks do not need to be switched.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - File register (ZR) - With Q4MCA-8MBS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4587520 points (ZR0...4587519) (Blocks do not need to be switched.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - Link special relay (SB)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2048 points (SB0...7FF) by default (changeable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - Link special register (SW)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2048 points (SW0...7FF) by default (changeable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - Step relay (S)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8192 points (S0...8191) by default (changeable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - Index register\/standard device register (Z)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 points (Z0...19) (maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - Pointer (P)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4096 points (P0...4095) (The number of device points is fixed.) (The local pointer range and the common pointer range can be set by parameter.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - Interrupt pointer (I)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e256 points (I0...255) (The number of device points is fixed.) (The fixed scan interval for the system interrupt pointer I28 to 31 can be set by parameter.) 0.5...1000.0 ms (in increments of 0.5 ms) Default I28: 100 ms, I29: 40 ms, I30: 20 ms, I31: 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - Special relay (SM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2048 points (SM0...2047) (The number of device points is fixed.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - Special register (SD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2048 points (SD0...2047) (The number of device points is fixed.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - Function input (FX)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 points (FX0...F) (The number of device points is fixed.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - Function output (FY)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 points (FY0...F) (The number of device points is fixed.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - Function register (FD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 points (FD0...4) (The number of device points is fixed.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eLink direct device\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDevice that directly accesses the link device of a network module Specification format: J□□\\X□□, J□□\\Y□□, J□□\\SB□□, J□□\\W□□, J□□\\SW□□\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eIntelligent function module device\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDevice that directly accesses the buffer memory of an intelligent function module Specified form: U...\\G...\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eLatch (data retention during power failure) range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8192 points (L0...8191) by default (The latch range can be set for the devices, B, F, V, T, ST, C, D, and W.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eRUN\/PAUSE contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOne contact can be set up in X0 to X1FFF for each of RUN and PAUSE.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eClock function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYear, month, date, hour, minute, second, and day of week (automatic leap year detection) Accuracy: -2.97...+3.75 s (TYP. +0.39 s)\/d at 0 ˚C Accuracy: -2.97...+3.75 s (TYP. +0.39 s)\/d at 25 ˚C Accuracy: -12.77...+2.13 s (TYP. -5.32 s)\/d at 55 ˚C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInternal current consumption (5 V DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.58 A (only CPU module), 0.6 A (with an extended SRAM cassette)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal dimensions - Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e98 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal dimensions - Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal dimensions - Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.20 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSpecifications of the built-in Ethernet function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e  \/ 100\/10 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTransmission specifications - Data transmission speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFull-duplex\/Half-duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTransmission specifications - Communication mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase band\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTransmission specifications - Transmission method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTransmission specifications - Maximum distance between hub and node\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotal of 16 for Socket communications, MELSOFT connections, and MC protocols. 1 for FTP.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOperating ambient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0...55 ˚C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eStorage ambient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...75 ˚C (The storage ambient temperature is -20 to 75 ˚C if the system includes the AnS\/A Series modules.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOperating ambient humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5...95 %RH, non-condensing (The operating ambient humidity and storage ambient humidity are 10 to 90 %RH if the system includes the AnS\/A Series modules.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eStorage ambient humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5...95 %RH, non-condensing (The operating ambient humidity and storage ambient humidity are 10 to 90 %RH if the system includes the AnS\/A Series modules.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eVibration resistance - Compliant with JIS B 3502 and IEC 61131-2 - Under intermittent vibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFrequency: 5...8.4 Hz, Half amplitude: 3.5 mm Frequency: 8.4...150 Hz, Constant acceleration: 9.8 m\/s 2 Sweep count: 10 times each in X, Y, Z directions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eVibration resistance - Compliant with JIS B 3502 and IEC 61131-2 - Under continuous vibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFrequency: 5...8.4 Hz, Half amplitude: 1.75 mm Frequency: 8.4...150 Hz, Constant acceleration: 4.9 m\/s 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eShock resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompliant with JIS B 3502 and IEC 61131-2 (147 m\/s 2 , 3 times each in 3 directions X, Y, Z)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOperating atmosphere\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo corrosive gases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0...2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInstallation location\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInside a control panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOvervoltage category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eII or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEquipment class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eRelay symbol language, logic symbolic language, MELSAP3 (SFC), MELSAP-L, function block and structured text (ST)\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137179177213,"sku":"Q06UDVCPU","price":392.72,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/Q06UDVCPU.jpg?v=1742537165"},{"product_id":"hgkr73","title":"Mitsubishi HGKR73 | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi HG-KR73\u003c\/h2\u003e\n\u003cp\u003eAC Servos-MELSERVO HG-KR73\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMELSERVO-J4 series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eModel name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHG-KR73\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eCompatible servo amplifier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRefer to \" Combinations of Rotary Servo Motors and Servo Amplifiers \" for compatible servo amplifier.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply capacity [kVA] *50\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eContinuous running duty *1 - Rated output [kW]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eContinuous running duty *1 - Rated torque [N・m] *2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum torque [N・m]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eRated speed [r\/min] *1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum speed [r\/min] *1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePermissible instantaneous speed [r\/min]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower rate at continuous rated torque [kW\/s]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eRated current [A]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum current [A]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMoment of inertia J [x 10 -4 kg・m 2 ]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eRecommended load to motor inertia ratio *3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17 times or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSpeed・position detector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAbsolute\/incremental 22-bit encoder (resolution: 4194304 pulses\/rev)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePermanent magnet synchronous motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOil seal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone (Servo motors with an oil seal are available. (HG-KR_J))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eThermistor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInsulation class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 (B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eStructure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotally enclosed, natural cooling (IP rating: IP65) *4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Ambient temperature - Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C to 40 °C (non-freezing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Ambient temperature - Strage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-15 °C to 70 °C (non-freezing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Ambient humidity - Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 %RH to 80 %RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Ambient humidity - Strage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 %RH to 90 %RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Ambience\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndoors (no direct sunlight); no corrosive gas, inflammable gas, oil mist or dust\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m or less above sea level *5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Vibration resistance *50\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eX: 49 m\/s 2 Y: 49 m\/s 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eVibration rank\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eV10 *50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSatisfied standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRefer to \" Standards and certifications (by product) Products \" for compliance with global standards and regulations.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePermissible load for the shaft *50 - L [mm]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePermissible load for the shaft *50 - Radial [N]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e392\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePermissible load for the shaft *50 - Thrust [N]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e147\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMass [kg]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eRefer to \" Combinations of Rotary Servo Motors and Servo Amplifiers \" for compatible servo amplifier.\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137179242749,"sku":"HGKR73","price":233.73,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/248655.jpg?v=1742537168"},{"product_id":"qd70p4","title":"Mitsubishi QD70P4 | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi QD70P4\u003c\/h2\u003e\n\u003cp\u003eMELSEC-Q Series QD70P4\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of control axes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 axes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInterpolation function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePTP (Point To Point) control, path control (linear only), speed-position switching control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003epulse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePositioning data\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 data \/axis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eData backup\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePositioning - Positioning system - PTP control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIncremental system\/absolute system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePositioning - Positioning system - Speed-position switching control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIncremental system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePositioning - Positioning system - Path control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIncremental system\/absolute system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePositioning - Positioning range - In absolute system\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e･ -2147483648...2147483647 pulse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePositioning - Positioning range - In incremental system\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e･ -2147483648...2147483647 pulse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePositioning - Positioning range - Speed-position switching control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e･ 0...2147483647 pulse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePositioning - Speed command\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0...200000 pulse\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePositioning - Acceleration\/deceleration process\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrapezoidal acceleration\/deceleration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePositioning - Acceleration\/deceleration time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0...32767 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eStarting time - Position control - 1-axis start\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eStarting time - Position control - 4-axes simultaneous start\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePulse output system\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOpen collector output system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum output pulse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200k pulse\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum connection distance between drive units\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal power supply - Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal power supply - Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.065 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal interface -  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40-pin connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal interface - Applicable connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA6CON1, A6CON2, A6CON4 (sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNumber of occupied I\/O points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 points (I\/O assignment: Intelligent 32 points)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInternal current consumption (5 V DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.55 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal dimensions - Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e98 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal dimensions - Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal dimensions - Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eGeneral specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRefer to the general specifications of the CPU module.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137179308285,"sku":"QD70P4","price":81.55,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/QD70P4.jpg?v=1784944132"},{"product_id":"fx5u32mres","title":"FX5U-32MR\/ES Mitsubishi Electric","description":"\u003ch2\u003eMitsubishi FX5U32MRES\u003c\/h2\u003e \u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e FX5U32MRES\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eMitsubishi FX Series PLC\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eMitsubishi Electric industrial automation product. Japanese quality, designed for reliable motion control and factory automation applications.\u003c\/p\u003e \u003ch3\u003eSpecifications:\u003c\/h3\u003e \u003ctable\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eType:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eCompact Programmable Logic Controller\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eProduct Category:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003ePLCs\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eProduct Series:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eMitsubishi FX1N\/FX3G\/FX3U\/FX5U Series\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eFunctions:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eProgrammable Logic Control, I\/O Processing\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eCommunication Protocols:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eRS-422, RS-485, Ethernet, CC-Link\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eI\/O Capacity:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eUp to 256 I\/O points (model dependent)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003ePower Source:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eAC 100-240V \/ 24V DC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eRecommended Use:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eSmall-Medium Automation, Machine Control\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eSuitable Space:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eControl Cabinet, Machine Panel\u003c\/td\u003e \u003c\/tr\u003e \u003c\/table\u003e \u003ch3\u003eCompatibility:\u003c\/h3\u003e \u003cp\u003eMitsubishi products support MELSEC PLC platforms (FX, Q, iQ-R series) and MELSERVO servo systems. Compatible with CC-Link, CC-Link IE, EtherNet\/IP, and SSCNET networks.\u003c\/p\u003e","brand":"Mitsubishi Electric","offers":[{"title":"New","offer_id":46137179373821,"sku":"FX5U32MRES","price":275.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/FX5U32MRES.jpg?v=1742537173"},{"product_id":"frd720s025scec","title":"FR-D720S-025SC-EC Mitsubishi Electric - 247597","description":"\u003ch2\u003eMitsubishi FRD720S025SCEC\u003c\/h2\u003e \u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e FRD720S025SCEC\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eMitsubishi VFD Accessory\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eMitsubishi Electric industrial automation product. Japanese quality, designed for reliable motion control and factory automation applications.\u003c\/p\u003e \u003ch3\u003eSpecifications:\u003c\/h3\u003e \u003ctable\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eType:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eVFD Option \/ Accessory\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eProduct Category:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eAccessories\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eFunctions:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eVFD Communication, Filtering, Braking\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eRecommended Use:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eVFD System Expansion, EMC Compliance\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eSuitable Space:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eControl Cabinet\u003c\/td\u003e \u003c\/tr\u003e \u003c\/table\u003e \u003ch3\u003eCompatibility:\u003c\/h3\u003e \u003cp\u003eMitsubishi products support MELSEC PLC platforms (FX, Q, iQ-R series) and MELSERVO servo systems. Compatible with CC-Link, CC-Link IE, EtherNet\/IP, and SSCNET networks.\u003c\/p\u003e","brand":"Mitsubishi Electric","offers":[{"title":"New","offer_id":46137179439357,"sku":"FRD720S025SCEC","price":237.87,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/FRD720S025SCEC.jpg?v=1742537175"},{"product_id":"hg-kr23","title":"Mitsubishi HG-KR23 | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi HG-KR23\u003c\/h2\u003e\n\u003cp\u003eAC Servos-MELSERVO HG-KR23\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMELSERVO-J4 series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eModel name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHG-KR23\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eCompatible servo amplifier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRefer to \" Combinations of Rotary Servo Motors and Servo Amplifiers \" for compatible servo amplifier.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply capacity [kVA] *50\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eContinuous running duty *1 - Rated output [kW]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eContinuous running duty *1 - Rated torque [N・m] *2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum torque [N・m]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eRated speed [r\/min] *1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum speed [r\/min] *1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePermissible instantaneous speed [r\/min]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower rate at continuous rated torque [kW\/s]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eRated current [A]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum current [A]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMoment of inertia J [x 10 -4 kg・m 2 ]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.221\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eRecommended load to motor inertia ratio *3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e26 times or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSpeed・position detector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAbsolute\/incremental 22-bit encoder (resolution: 4194304 pulses\/rev)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePermanent magnet synchronous motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOil seal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone (Servo motors with an oil seal are available. (HG-KR_J))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eThermistor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInsulation class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 (B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eStructure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotally enclosed, natural cooling (IP rating: IP65) *4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Ambient temperature - Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C to 40 °C (non-freezing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Ambient temperature - Strage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-15 °C to 70 °C (non-freezing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Ambient humidity - Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 %RH to 80 %RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Ambient humidity - Strage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 %RH to 90 %RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Ambience\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndoors (no direct sunlight); no corrosive gas, inflammable gas, oil mist or dust\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m or less above sea level *5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Vibration resistance *50\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eX: 49 m\/s 2 Y: 49 m\/s 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eVibration rank\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eV10 *50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSatisfied standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRefer to \" Standards and certifications (by product) Products \" for compliance with global standards and regulations.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePermissible load for the shaft *50 - L [mm]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePermissible load for the shaft *50 - Radial [N]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e245\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePermissible load for the shaft *50 - Thrust [N]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e98\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMass [kg]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.91\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eRefer to \" Combinations of Rotary Servo Motors and Servo Amplifiers \" for compatible servo amplifier.\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137179570429,"sku":"HG-KR23","price":37.11,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/HG-KR23.jpg?v=1784944140"},{"product_id":"mr-j2s-70cp","title":"Mitsubishi MR-J2S-70CP | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi MR-J2S-70CP\u003c\/h2\u003e \u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e MR-J2S-70CP\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eMitsubishi Servo Amplifier \/ Drive\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eMitsubishi Electric industrial automation product. Japanese quality, designed for reliable motion control and factory automation applications.\u003c\/p\u003e \u003ch3\u003eSpecifications:\u003c\/h3\u003e \u003ctable\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eType:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eAC Servo Amplifier \/ Drive\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eProduct Category:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eServo Drives\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eProduct Series:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eMitsubishi MR-J4\/J3\/J2S\/J2\/JE\/E\/C\/H Series\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eFunctions:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eServo Motor Control, Position\/Speed\/Torque Control\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eControl Method:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eVector Control, SSCNET III\/IV\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eCommunication Protocols:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eSSCNET, EtherCAT, CC-Link, RS-422\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003ePower Source:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eAC 200-240V \/ 380-480V\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eRecommended Use:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eIndustrial Motion Control, CNC, Robotics\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eSuitable Space:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eControl Cabinet\u003c\/td\u003e \u003c\/tr\u003e \u003c\/table\u003e \u003ch3\u003eCompatibility:\u003c\/h3\u003e \u003cp\u003eMitsubishi products support MELSEC PLC platforms (FX, Q, iQ-R series) and MELSERVO servo systems. Compatible with CC-Link, CC-Link IE, EtherNet\/IP, and SSCNET networks.\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137179668733,"sku":"MR-J2S-70CP","price":198.56,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/MR-J2S-70CP.jpg?v=1784944149"},{"product_id":"mr-j2s-40cp","title":"Mitsubishi MR-J2S-40CP | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi MR-J2S-40CP\u003c\/h2\u003e \u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e MR-J2S-40CP\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eMitsubishi Servo Amplifier \/ Drive\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eMitsubishi Electric industrial automation product. Japanese quality, designed for reliable motion control and factory automation applications.\u003c\/p\u003e \u003ch3\u003eSpecifications:\u003c\/h3\u003e \u003ctable\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eType:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eAC Servo Amplifier \/ Drive\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eProduct Category:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eServo Drives\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eProduct Series:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eMitsubishi MR-J4\/J3\/J2S\/J2\/JE\/E\/C\/H Series\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eFunctions:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eServo Motor Control, Position\/Speed\/Torque Control\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eControl Method:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eVector Control, SSCNET III\/IV\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eCommunication Protocols:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eSSCNET, EtherCAT, CC-Link, RS-422\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003ePower Source:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eAC 200-240V \/ 380-480V\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eRecommended Use:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eIndustrial Motion Control, CNC, Robotics\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eSuitable Space:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eControl Cabinet\u003c\/td\u003e \u003c\/tr\u003e \u003c\/table\u003e \u003ch3\u003eCompatibility:\u003c\/h3\u003e \u003cp\u003eMitsubishi products support MELSEC PLC platforms (FX, Q, iQ-R series) and MELSERVO servo systems. Compatible with CC-Link, CC-Link IE, EtherNet\/IP, and SSCNET networks.\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137179734269,"sku":"MR-J2S-40CP","price":146.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/MR-J2S-40CP.jpg?v=1784944158"},{"product_id":"mr-j2s-40b","title":"Mitsubishi MR-J2S-40B | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi MR-J2S-40B\u003c\/h2\u003e \u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e MR-J2S-40B\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eMitsubishi Servo Amplifier \/ Drive\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eMitsubishi Electric industrial automation product. Japanese quality, designed for reliable motion control and factory automation applications.\u003c\/p\u003e \u003ch3\u003eSpecifications:\u003c\/h3\u003e \u003ctable\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eType:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eAC Servo Amplifier \/ Drive\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eProduct Category:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eServo Drives\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eProduct Series:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eMitsubishi MR-J4\/J3\/J2S\/J2\/JE\/E\/C\/H Series\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eFunctions:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eServo Motor Control, Position\/Speed\/Torque Control\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eControl Method:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eVector Control, SSCNET III\/IV\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eCommunication Protocols:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eSSCNET, EtherCAT, CC-Link, RS-422\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003ePower Source:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eAC 200-240V \/ 380-480V\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eRecommended Use:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eIndustrial Motion Control, CNC, Robotics\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eSuitable Space:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eControl Cabinet\u003c\/td\u003e \u003c\/tr\u003e \u003c\/table\u003e \u003ch3\u003eCompatibility:\u003c\/h3\u003e \u003cp\u003eMitsubishi products support MELSEC PLC platforms (FX, Q, iQ-R series) and MELSERVO servo systems. Compatible with CC-Link, CC-Link IE, EtherNet\/IP, and SSCNET networks.\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137179832573,"sku":"MR-J2S-40B","price":94.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/MR-J2S-40B.jpg?v=1784944165"},{"product_id":"mr-j2s-200a","title":"Mitsubishi MR-J2S-200A | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi MR-J2S-200A\u003c\/h2\u003e \u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e MR-J2S-200A\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eMitsubishi Servo Amplifier \/ Drive\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eMitsubishi Electric industrial automation product. Japanese quality, designed for reliable motion control and factory automation applications.\u003c\/p\u003e \u003ch3\u003eSpecifications:\u003c\/h3\u003e \u003ctable\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eType:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eAC Servo Amplifier \/ Drive\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eProduct Category:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eServo Drives\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eProduct Series:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eMitsubishi MR-J4\/J3\/J2S\/J2\/JE\/E\/C\/H Series\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eFunctions:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eServo Motor Control, Position\/Speed\/Torque Control\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eControl Method:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eVector Control, SSCNET III\/IV\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eCommunication Protocols:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eSSCNET, EtherCAT, CC-Link, RS-422\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003ePower Source:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eAC 200-240V \/ 380-480V\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eRecommended Use:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eIndustrial Motion Control, CNC, Robotics\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eSuitable Space:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eControl Cabinet\u003c\/td\u003e \u003c\/tr\u003e \u003c\/table\u003e \u003ch3\u003eCompatibility:\u003c\/h3\u003e \u003cp\u003eMitsubishi products support MELSEC PLC platforms (FX, Q, iQ-R series) and MELSERVO servo systems. Compatible with CC-Link, CC-Link IE, EtherNet\/IP, and SSCNET networks.\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137179898109,"sku":"MR-J2S-200A","price":256.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/MRJ2S200A.jpg?v=1742537190"},{"product_id":"fx0n-3a","title":"Mitsubishi FX0N-3A | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi FX0N-3A\u003c\/h2\u003e\n\u003cp\u003eMELSEC-F Series FX0N-3A\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eApplicable PLC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFX1N, FX2N, FX3U, FX1NC, FX2NC, FX3UC [Connecting to the connector-type PLC] The FX2NC-CNV-IF is required to connect the FX1NC and FX2NC. The FX2NC-CNV-IF or FX3UC-1PS-5V is required to connect the FX3UC.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNumber of occupied I\/O points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 points (Taken from either the input or output points of the PLC.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMass (weight)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - Analog input range - Voltage input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 V to 10 V DC, 0 V to 5 V DC(Input resistance 200kΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - Analog input range - Current input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA DC (Input resistance 250 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - Number of input channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - Absolute maximum input - Voltage input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-0.5 V, +15 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - Absolute maximum input - Current input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-2 mA, +60 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - Digital output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 bits binary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - Resolution - Voltage input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWhen 0 V to 10 V: 40 mV (10 V × 1\/250) When 0 V to 5 V: 20 mV (5 V × 1\/250)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - Resolution - Current input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 μA (16 mA × 1\/250)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - Total accuracy - Voltage input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±1% (±0.1 V) for 10 V full scale Same for 0 V to 5 V DC input (±0.1V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - Total accuracy - Current input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±1% (±0.16 mA) for 16 mA full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - A\/D conversion time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTO instruction processing time × 2 + FROM instruction processing time (Operation synchronized with sequence program)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog output - Analog output range - Voltage output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 V to 10 V DC, 0 V to 5 V DC (External load resistance: 1 kΩ to 1 MΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog output - Analog output range - Current output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 mA to 20 mA DC (External load resistance: 500 Ω or less)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog output - No. of output channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog output - Output characteristics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThe output characteristics can be adjusted with the OFFSET\/GAIN volume.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog output - Digital input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 bits binary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog output - Resolution - Voltage output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWhen 0 V to 10 V: 40 mV (10 V × 1\/250) When 0 V to 5 V: 20 mV (5 V × 1\/250)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog output - Resolution - Current output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWhen 4 mA to 20 mA DC: 64 μA (16 mA × 1\/250)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog output - Total accuracy - Voltage output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog output - Total accuracy - Current output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.16 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog output - Time required for D\/A conversion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTO instruction processing time × 3 (Operation synchronized with sequence program)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e  \/ 5 V DC 30 mA (internal power supply from PLC main unit) 24 V DC ±10% 90 mA(internal power supply from PLC main unit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 55°C (32 to 131 °F) when operating and -25 to 75°C (-13 to 167 °F) when stored\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAmbient humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 to 95%RH (no condensation) when operating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eVibration resistance - Installed on DIN rail - Frequency: 10 to 57 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHalf amplitude: 0.035 mm Sweep Count for X, Y, Z: 10 times (80 min in each direction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eVibration resistance - Installed on DIN rail - Frequency: 57 to 150 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAcceleration: 4.9 m\/s 2 Sweep Count for X, Y, Z: 10 times (80 min in each direction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eVibration resistance - Direct installing - Frequency: 10 to 57 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHalf amplitude: 0.075 mm Sweep Count for X, Y, Z: 10 times (80 min in each direction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDirect installing - Frequency: 57 to 150 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAcceleration: 9.8 m\/s 2 Sweep Count for X, Y, Z: 10 times (80 min in each direction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eShock resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e147 m\/s 2 Acceleration, Action time: 11 ms, 3 times by half-sine pulse in each direction X, Y, and Z\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNoise resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBy noise simulator at noise voltage of 1,000 Vp-p, noise width of 1 μs, rise time of 1 ns and period of 30 to 100 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDielectric withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBetween batch of all terminals and ground terminal: 500 V AC for 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBetween batch of all terminals and ground terminal: 5 MΩ or higher by 500 V DC insulation resistance tester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eWorking atmosphere\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFree from corrosive or flammable gas and excessive conductive dusts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eWorking altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m or less Do not use the PLC under pressure higher than the atmospheric pressure. Doing so may damage the PLC.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eFX1N, FX2N, FX3U, FX1NC, FX2NC, FX3UC [Connecting to the connector-type PLC] The FX2NC-CNV-IF is required to connect the FX1NC and FX2NC. The FX2NC-CNV-IF or FX3UC-1PS-5V is required to connect the FX\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137179963645,"sku":"FX0N-3A","price":49.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/mitsubishi_generic_brand_68f08cf8-4182-49d1-a69d-f34745ce3df9.jpg?v=1784955412"},{"product_id":"fx3u-4ad","title":"Mitsubishi FX3U-4AD | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi FX3U-4AD\u003c\/h2\u003e\n\u003cp\u003eMELSEC-F Series FX3U-4AD\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eApplicable PLC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFX5U, FX5UC, FX3U (Ver.2.20 or later), FX3UC(FX3UC-32MT-LT is Ver.1.30 or later) [Connecting to the FX5U, FX5UC CPU module] FX5-CNV-BUS or FX5-CNV-BUSC is required to connect to the FX5U\/FX5UC CPU module. Select one of the modules according to the system configuration. [Connecting to the connector-t\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNumber of occupied I\/O points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 points (Taken from either the input or output points of the PLC.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMass (weight)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - Analog input range - Voltage input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10 V to +10 V DC(Input resistance 200 kΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - Analog input range - Current input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 mA to +20 mA DC, 4 mA to 20 mA DC (Input resistance 250 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - Number of input channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - Absolute maximum input - Voltage input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±15 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - Absolute maximum input - Current input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - Input characteristics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThe input mode (voltage\/current input) can be set for each channel.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - Digital output - Voltage input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 bits binary + sign 1 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - Digital output - Current input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 bits binary + sign 1 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - Resolution - Voltage input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.32 mV (20 V × 1\/64000) 2.5 mV (20 V × 1\/8000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - Resolution - Current input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.25 μA (40 mA × 1\/32000) 5.00 μA (40 mA × 1\/8000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - Total accuracy - Voltage input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAmbient temperature: 25°C±5°C ±0.3% (±60 mV) for 20 V full scale Ambient temperature: 0°C to 55°C ±0.5% (±100 mV) for 20 V full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - Total accuracy - Current input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAmbient temperature: 25°C±5°C ±0.5% (±200 μA) for 40 mA full scale, Same accuracy (±200 μA) for 4 mA to 20 mA input Ambient temperature: 0°C to 55°C ±1% (±400 μA) for 40 mA full scale, Same accuracy for 4 mA to 20 mA input (±400 μA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog input - A\/D conversion time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 μs x number of channels in use (When using a digital filter on one or more channels, 5 ms x number of channels in use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e  \/ 5 V DC 110 mA (internal power supply from PLC main unit) 24 V DC ±10% 90 mA (External power supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAmbient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 55°C (32 to 131 °F) when operating and -25 to 75°C (-13 to 167 °F) when stored\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAmbient humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 to 95%RH (no condensation) when operating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eVibration resistance - Installed on DIN rail - Frequency: 10 to 57 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHalf amplitude: 0.035 mm Sweep Count for X, Y, Z: 10 times (80 min in each direction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eVibration resistance - Installed on DIN rail - Frequency: 57 to 150 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAcceleration: 4.9 m\/s 2 Sweep Count for X, Y, Z: 10 times (80 min in each direction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eVibration resistance - Direct installing - Frequency: 10 to 57 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHalf amplitude: 0.075 mm Sweep Count for X, Y, Z: 10 times (80 min in each direction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eVibration resistance - Direct installing - Frequency: 57 to 150 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAcceleration: 9.8 m\/s 2 Sweep Count for X, Y, Z: 10 times (80 min in each direction)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eShock resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e147 m\/s 2 Acceleration, Action time: 11 ms, 3 times by half-sine pulse in each direction X, Y, and Z\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNoise resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBy noise simulator at noise voltage of 1,000 Vp-p, noise width of 1 μs, rise time of 1 ns and period of 30 to 100 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDielectric withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBetween batch of all terminals and ground terminal: 500 V AC for 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBetween batch of all terminals and ground terminal: 5 MΩ or higher by 500 V DC insulation resistance tester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eGrounding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass D grounding (grounding resistance: 100 Ω or less) (Common grounding with a heavy electrical system is not allowed) Ground the PLC independently or jointly.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eWorking atmosphere\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFree from corrosive or flammable gas and excessive conductive dusts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eWorking altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m or less Do not use the PLC under pressure higher than the atmospheric pressure. Doing so may damage the PLC.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eFX5U, FX5UC, FX3U (Ver.2.20 or later), FX3UC(FX3UC-32MT-LT is Ver.1.30 or later) [Connecting to the FX5U, FX5UC CPU module] FX5-CNV-BUS or FX5-CNV-BUSC is required to connect to the FX5U\/FX5UC CPU mod\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137180029181,"sku":"FX3U-4AD","price":76.12,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/169508.jpg?v=1742537194"},{"product_id":"rx40c7","title":"Mitsubishi RX40C7 | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi RX40C7\u003c\/h2\u003e\n\u003cp\u003eMELSEC iQ-R Series RX40C7\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInput specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e  \/ DC input (positive\/negative shared common type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInput type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNumber of input points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC (ripple ratio: within 5 %) (allowable voltage range: 20.4...28.8 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eRated input voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.0 mA TYP. (24 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eRated input current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 V or more\/4 mA or more\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eON voltage\/ON current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 V or less\/2 mA or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOFF voltage\/OFF current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.3 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInput resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 ms, 0.2 ms, 0.4 ms, 0.6 ms, 1 ms, 5 ms, 10 ms, 20 ms, 70 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInput response time - OFF to ON\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.35 ms, 0.4 ms, 0.5 ms, 0.7 ms, 1 ms, 5 ms, 10 ms, 20 ms, 70 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInput response time - ON to OFF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 points\/common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInput common terminal arrangement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAvailable (set by module parameters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInterrupt function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e  \/ 510 V AC rms for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eCommon specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 MΩ or higher by insulation resistance tester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDielectric withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18-point terminal block (M3 screw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProtection degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 points (I\/O assignment: Input 16 points)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal interface -  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNumber of occupied I\/O points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e106 mm (base unit mounting side: 98 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInternal current consumption (5 V DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal dimensions - Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e131 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal dimensions - Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.16 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eGeneral specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRefer to the general specifications of the CPU module or remote head module.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137180094717,"sku":"RX40C7","price":71.26,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/W1siZiIsIjIwMjAvMDIvMDQvMTQvNDAvMDcvY2E5YzllZDYtOGQxNS00NWNlLWI0MTgtZTc4MzM1ODVkYzZjL3J4NDBjNy5qcGciXSxbInAiLCJ0aHVtYiIsIjQwMHg0MDBcdTAwM2UiXV0_dfe6574f-f3ee-4c0a-b100-75624dd66ce0.jpg?v=1742537197"},{"product_id":"mrj470b","title":"Mitsubishi MRJ470B | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi MR-J4-70B\u003c\/h2\u003e\n\u003cp\u003eAC Servos-MELSERVO MR-J4-70B\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMELSERVO-J4 series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eModel name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMR-J4-70B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eCapacity [kW]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eCommand interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSSCNET III\/H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput - Rated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-phase 170 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput - Rated current [A]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMain circuit power supply input - Voltage\/frequency *1 - AC input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-phase or 1-phase 200 V AC to 240 V AC, 50 Hz\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMain circuit power supply input - Rated current [A] *3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMain circuit power supply input - Permissible voltage fluctuation - AC input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-phase or 1-phase 170 V AC to 264 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMain circuit power supply input - Permissible frequency fluctuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±5 % maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl circuit power supply input - Voltage\/frequency - AC input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-phase 200 V AC to 240 V AC, 50 Hz\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl circuit power supply input - Rated current [A]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl circuit power supply input - Permissible voltage fluctuation - AC input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-phase 170 V AC to 264 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl circuit power supply input - Permissible frequency fluctuation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±5 % maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl circuit power supply input - Power consumption [W]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInterface power supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC ± 10 % (required current capacity: 0.3 A (including CN8 connector signals))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSine-wave PWM control\/current control method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePermissible regenerative power - Built-in regenerative resistor [W] *4 *5\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePermissible regenerative power - External regenerative resistor (standard accessory) [W] *4 *5 *6 *7\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDynamic brake *8\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eCommand communication cycle *10\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.222 ms, 0.444 ms, 0.888 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eCommunication function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB: Connect a personal computer (MR Configurator2 compatible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eA\/B\/Z-phase pulse output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eAnalog monitor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eFully closed loop control *11\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo-wire type communication method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eLoad-side encoder interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMitsubishi Electric high-speed serial communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eServo functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdvanced vibration suppression control II, adaptive filter II, robust filter, auto tuning, one-touch tuning, tough drive function, drive recorder function, tightening \u0026amp; press-fit control, machine diagnosis function, power monitoring function, driver communication function *12 , scale measurement fun\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProtective functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOvercurrent shut-off, regenerative overvoltage shut-off, overload shut-off (electronic thermal), servo motor overheat protection, encoder error protection, regenerative error protection, undervoltage protection, instantaneous power failure protection, overspeed protection, error excessive protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSafety sub-function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSTO (IEC\/EN 61800-5-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSafety performance - Satisfied standards *14\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN ISO 13849-1:2015 Category 3 PL e, IEC 61508 SIL 3, EN 62061 SIL CL 3, EN 61800-5-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSafety performance - Response performance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 ms or less (STO input OFF → energy shut-off)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSafety performance - Test pulse input (STO) *15\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTest pulse interval: 1 Hz to 25 Hz, test pulse off time: 1 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSafety performance - Mean time to dangerous failure (MTTFd)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMTTFd ≥ 100 [years] (314a)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSafety performance - Diagnostic coverage (DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC = Medium, 97.6 [%]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSafety performance - Probability of dangerous Failure per Hour (PFH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePFH = 6.4 × 10 -9 [1\/h]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSatisfied standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRefer to \" Standards and certifications (by product) Products \" for compliance with global standards and regulations.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eStructure (IP rating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eForce cooling, open (IP20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eClose mounting - 3-phase power supply input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePossible *17\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eClose mounting - 1-phase power supply input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePossible *17\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment - Ambient temperature - Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C to 55 °C (non-freezing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment - Ambient temperature - Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 °C to 65 °C (non-freezing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment - Ambient humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOperation\/storage: 5 %RH to 90 %RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment - Ambience\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndoors (no direct sunlight); no corrosive gas, inflammable gas, oil mist or dust\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment - Altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m or less above sea level *18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment - Vibration resistance -  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.9 m\/s 2 at 10 Hz to 55 Hz (directions of X, Y, and Z axes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMass [kg]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137180160253,"sku":"MRJ470B","price":239.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/MRJ470B.jpg?v=1742537199"},{"product_id":"aj65bt64ad","title":"Mitsubishi AJ65BT64AD | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi AJ65BT64AD\u003c\/h2\u003e \u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e AJ65BT64AD\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eMitsubishi Communication Module\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eMitsubishi Electric industrial automation product. Japanese quality, designed for reliable motion control and factory automation applications.\u003c\/p\u003e \u003ch3\u003eSpecifications:\u003c\/h3\u003e \u003ctable\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eType:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003ePLC Communication Module\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eProduct Category:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eCommunication\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eProduct Series:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eMitsubishi QJ71\/RJ71\/AJ Series\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eFunctions:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eNetwork Communication, Data Exchange\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eCommunication Protocols:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eEtherNet\/IP, CC-Link IE, Modbus, PROFIBUS, DeviceNet\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eRecommended Use:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003ePLC Networking, SCADA Integration\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eSuitable Space:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eControl Cabinet\u003c\/td\u003e \u003c\/tr\u003e \u003c\/table\u003e \u003ch3\u003eCompatibility:\u003c\/h3\u003e \u003cp\u003eMitsubishi products support MELSEC PLC platforms (FX, Q, iQ-R series) and MELSERVO servo systems. Compatible with CC-Link, CC-Link IE, EtherNet\/IP, and SSCNET networks.\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137180225789,"sku":"AJ65BT64AD","price":89.14,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/AJ65BT64AD.jpg?v=1742537201"},{"product_id":"qy42p","title":"Mitsubishi QY42P | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi QY42P\u003c\/h2\u003e\n\u003cp\u003eMELSEC-Q Series QY42P\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e  \/ Transistor output (sink type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNumber of output points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12...24 V DC (+20\/-15 %)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eRated load voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 A\/point, 2 A\/common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum load current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7 A, 10 ms or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum inrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mA or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eLeakage current at OFF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 V DC (TYP.) 0.1 A, 0.2 V DC (MAX.) 0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum voltage drop at ON\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 ms or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput response time - OFF to ON\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 ms or less (rated load, resistive load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput response time - ON to OFF\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eZener diode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSurge suppressor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eFuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAvailable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProtection function - Overheat protection function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAvailable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProtection function - Overload protection function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12...24 V DC (+20\/-15 %) (ripple ratio within 5 %)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal power supply - Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 mA (at 24 V DC)\/common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal power supply - Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 points\/common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOutput common terminal arrangement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e  \/ Photocoupler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eCommon specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e560 V AC rms\/3 cycles (altitude 2000 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eIsolation method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 MΩ or higher by insulation resistance tester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDielectric withstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eON indication (LED), 32 point switch-over using switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProtection degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40-pin connector × 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOperation indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA6CON1, A6CON2, A6CON3, A6CON4 (sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal interface -  \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 points (I\/O assignment: Output 64 points)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal interface - Applicable connector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 mA (TYP. all points ON)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNumber of occupied I\/O points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e98 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInternal current consumption (5 V DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal dimensions - Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal dimensions - Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.17 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eGeneral specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRefer to the general specifications of the CPU module.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137180389629,"sku":"QY42P","price":33.26,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/XYeTLHIglBeauhUOQHcHidxOaJQ6C4hworSONidfloKCJkOj2SNqxZno2uE6.jpg?v=1742537204"},{"product_id":"a1sy41","title":"Mitsubishi A1SY41 | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi A1SY41\u003c\/h2\u003e \u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e A1SY41\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eMitsubishi PLC Module\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eMitsubishi Electric industrial automation product. Japanese quality, designed for reliable motion control and factory automation applications.\u003c\/p\u003e \u003ch3\u003eSpecifications:\u003c\/h3\u003e \u003ctable\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eType:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003ePLC Function Module\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eProduct Category:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003ePLCs\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eFunctions:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eAnalog I\/O, Temperature Control, High-Speed Counter\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eRecommended Use:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eProcess Control, Measurement\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eSuitable Space:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eControl Cabinet\u003c\/td\u003e \u003c\/tr\u003e \u003c\/table\u003e \u003ch3\u003eCompatibility:\u003c\/h3\u003e \u003cp\u003eMitsubishi products support MELSEC PLC platforms (FX, Q, iQ-R series) and MELSERVO servo systems. Compatible with CC-Link, CC-Link IE, EtherNet\/IP, and SSCNET networks.\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137180520701,"sku":"A1SY41","price":26.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/mitsubishi_generic_brand_bd996f1b-4077-4a6f-9f84-ddf8429b20a3.jpg?v=1784950177"},{"product_id":"hgkr73b","title":"Mitsubishi HGKR73B | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi HG-KR73B\u003c\/h2\u003e\n\u003cp\u003eAC Servos-MELSERVO HG-KR73B\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMELSERVO-J4 series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eModel name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHG-KR73B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eCompatible servo amplifier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRefer to \" Combinations of Rotary Servo Motors and Servo Amplifiers \" for compatible servo amplifier.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply capacity [kVA] *50\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eContinuous running duty *1 - Rated output [kW]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eContinuous running duty *1 - Rated torque [N・m] *2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum torque [N・m]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eRated speed [r\/min] *1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum speed [r\/min] *1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePermissible instantaneous speed [r\/min]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower rate at continuous rated torque [kW\/s]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e41.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eRated current [A]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum current [A]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMoment of inertia J [x 10 -4 kg・m 2 ]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eRecommended load to motor inertia ratio *3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17 times or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSpeed・position detector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAbsolute\/incremental 22-bit encoder (resolution: 4194304 pulses\/rev)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePermanent magnet synchronous motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOil seal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone (Servo motors with an oil seal are available. (HG-KR_J))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eThermistor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInsulation class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 (B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eStructure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotally enclosed, natural cooling (IP rating: IP65) *4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Ambient temperature - Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C to 40 °C (non-freezing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Ambient temperature - Strage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-15 °C to 70 °C (non-freezing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Ambient humidity - Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 %RH to 80 %RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Ambient humidity - Strage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 %RH to 90 %RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Ambience\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndoors (no direct sunlight); no corrosive gas, inflammable gas, oil mist or dust\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m or less above sea level *5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Vibration resistance *50\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eX: 49 m\/s 2 Y: 49 m\/s 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eVibration rank\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eV10 *50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSatisfied standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRefer to \" Standards and certifications (by product) Products \" for compliance with global standards and regulations.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePermissible load for the shaft *50 - L [mm]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePermissible load for the shaft *50 - Radial [N]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e392\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePermissible load for the shaft *50 - Thrust [N]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e147\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMass [kg]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eElectromagnetic Brake *6 - Servo motor model name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHG-KR73B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eElectromagnetic Brake *6 - Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpring actuated type safety brake\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eElectromagnetic Brake *6 - Rated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC (-10 % to 0 %)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eElectromagnetic Brake *6 - Power consumption [W] at 20 ﾟC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eElectromagnetic Brake *6 - Electromagnetic brake static friction torque [N・m]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.4 or higher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eElectromagnetic Brake *6 - Permissible braking work - Per braking [J]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eElectromagnetic Brake *6 - Permissible braking work - Per hour [J]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e640\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eElectromagnetic Brake *6 - Electromagnetic brake life *7 - Number of braking times\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eElectromagnetic Brake *6 - Electromagnetic brake life *7 - Work per braking [J]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eRefer to \" Combinations of Rotary Servo Motors and Servo Amplifiers \" for compatible servo amplifier.\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137180586237,"sku":"HGKR73B","price":239.03,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/HGKR73B.jpg?v=1742537210"},{"product_id":"q35b","title":"Mitsubishi Q35B | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi Q35B\u003c\/h2\u003e\n\u003cp\u003eMELSEC-Q Series Q35B\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNumber of mountable I\/O modules\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePossibility of extension\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExtendable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eApplicable module\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMELSEC-Q series modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eApplicable power supply module\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMELSEC-Q series power supply module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInternal current consumption (5 V DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.11 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMounting hole size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eM4 screw hole or ø4.5 hole (for M4 screw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal dimensions - Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e98 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal dimensions - Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e245 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal dimensions - Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e44.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.27 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eDIN rail mounting adapter type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQ6DIN2 (sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eGeneral specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRefer to the general specifications of the CPU module.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eMELSEC-Q series power supply module\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137180684541,"sku":"Q35B","price":57.79,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/0ns26UNVjKYVTu7NG6rJnBJEE7iUEwwQVMclkQkwYsCNYVUAbG3bNyhMmVMr.jpg?v=1742537214"},{"product_id":"q03udcpu","title":"Mitsubishi Q03UDCPU | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi Q03UDCPU\u003c\/h2\u003e\n\u003cp\u003eMELSEC-Q Series Q03UDCPU\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eControl method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStored program cyclic operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eI\/O control mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRefresh mode (The direct access input\/output is available by specifying the direct access input\/output (DX, DY).)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProgramming language - Sequence control language\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRelay symbol language, logic symbolic language, MELSAP3 (SFC), MELSAP-L, function block and structured text (ST)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProcessing speed - Sequence instruction - LD X0\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProcessing speed - Sequence instruction - MOV D0 D1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eConstant scan\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5...2000 ms (setting is available in increments of 0.5 ms by parameter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eProgram capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30K steps (120K bytes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMemory capacity - Program memory (drive 0)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120K bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMemory capacity - Memory card (RAM) (drive 1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSize of the installed memory card (8M bytes max.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMemory capacity - Memory card (ROM) (drive 2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSize of the installed memory card (Flash card: 4M bytes max., ATA card: 32M bytes max.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMemory capacity - Standard RAM (drive 3)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e192K bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMemory capacity - Standard ROM (drive 4)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1024K bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMemory capacity - CPU shared memory - QCPU standard memory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8K bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMemory capacity - CPU shared memory - Multiple CPU high speed transmission area\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32K bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of storable files - Program memory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e124\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of storable files - Memory card (ROM) - Flash card\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e288\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of storable files - Memory card (ROM) - ATA card\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e511\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of storable files - Standard RAM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of storable files - Standard ROM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e256\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of intelligent function module parameters - Initial setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4096 parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of intelligent function module parameters - Refresh\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2048 parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNumber of I\/O device points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8192 points (X\/Y0...1FFF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNumber of I\/O points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4096 points (X\/Y0...FFF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - Internal relay (M)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8192 points (M0...8191) by default (changeable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - Latch relay (L)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8192 points (L0...8191) by default (changeable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - Link relay (B)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8192 points (B0...1FFF) by default (changeable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - Timer (T)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2048 points (T0...2047) by default (changeable) (Low-speed and high-speed timers available) Low-speed or high-speed is specified by an instruction. The measurement unit is set by parameter. (Low-speed timer: 1...1000 ms (in increments of 1 ms), default: 100 ms) (High-speed timer: 0.1...100.0 ms (in \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - Retentive timer (ST)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 points by default (changeable) (Low-speed and high-speed retentive timers available) Low-speed or high-speed is specified by an instruction. The measurement unit is set by parameter. (Low-speed retentive timer: 1...1000 ms (in increments of 1 ms), default: 100 ms) (High-speed retentive timer: 0.1.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - Counter (C)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNormal counter: 1024 points (C0...1023) by default (changeable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - Data register (D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12288 points (D0...12287) by default (changeable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - Extended data register (D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 points by default (changeable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - Link register (W)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8192 points (W0...1FFF) by default (changeable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - Extended link register (W)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 points by default (changeable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - Annunciator (F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2048 points (F0...2047) by default (changeable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - Edge relay (V)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2048 points (V0...2047) by default (changeable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - File register (R) - Standard RAM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32768 points (R0...32767) (Maximum 98304 points are available by switching blocks.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - File register (R) - SRAM card (1M byte)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32768 points (R0...32767) (Maximum 517120 points are available by switching blocks.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - File register (R) - SRAM card (2M bytes)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32768 points (R0...32767) (Maximum 1041408 points are available by switching blocks.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - File register (R) - SRAM card (4M bytes)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32768 points (R0...32767) (Maximum 2087936 points are available by switching blocks.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - File register (R) - SRAM card (8M bytes)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32768 points (R0...32767) (Maximum 4184064 points are available by switching blocks.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - File register (R) - Flash card (2M bytes)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32768 points (R0...32767) (Maximum 1041408 points are available by switching blocks.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - File register (R) - Flash card (4M bytes)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32768 points (R0...32767) (Maximum 2087936 points are available by switching blocks.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - File register (ZR) - Standard RAM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e98304 points (ZR0...98303) (Blocks do not need to be switched.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - File register (ZR) - SRAM card (1M byte)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e517120 points (ZR0...517119) (Blocks do not need to be switched.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - File register (ZR) - SRAM card (2M bytes)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1041408 points (ZR0...1041407) (Blocks do not need to be switched.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - File register (ZR) - SRAM card (4M bytes)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2087936 points (ZR0...2087935) (Blocks do not need to be switched.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - File register (ZR) - SRAM card (8M bytes)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4184064 points (ZR0...4184063) (Blocks do not need to be switched.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - File register (ZR) - Flash card (2M bytes)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1041408 points (ZR0...1041407) (Blocks do not need to be switched.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - File register (ZR) - Flash card (4M bytes)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2087936 points (ZR0...2087935) (Blocks do not need to be switched.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - Link special relay (SB)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2048 points (SB0...7FF) by default (changeable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - Link special register (SW)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2048 points (SW0...7FF) by default (changeable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - Step relay (S)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8192 points (S0...8191) by default (changeable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - Index register\/standard device register (Z)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 points (Z0...19) (maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - Pointer (P)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4096 points (P0...4095) (The number of device points is fixed.) (The local pointer range and the common pointer range can be set by parameter.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - Interrupt pointer (I)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e256 points (I0...255) (The number of device points is fixed.) (The fixed scan interval for the system interrupt pointer I28 to 31 can be set by parameter.) 0.5...1000.0 ms (in increments of 0.5 ms) Default I28: 100 ms, I29: 40 ms, I30: 20 ms, I31: 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - Special relay (SM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2048 points (SM0...2047) (The number of device points is fixed.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - Special register (SD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2048 points (SD0...2047) (The number of device points is fixed.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - Function input (FX)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 points (FX0...F) (The number of device points is fixed.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - Function output (FY)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 points (FY0...F) (The number of device points is fixed.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNo. of device points - Function register (FD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 points (FD0...4) (The number of device points is fixed.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eLink direct device\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDevice that directly accesses the link device of a network module Specification format: J□□\\X□□, J□□\\Y□□, J□□\\SB□□, J□□\\W□□, J□□\\SW□□\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eIntelligent function module device\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDevice that directly accesses the buffer memory of an intelligent function module Specified form: U...\\G...\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eLatch (data retention during power failure) range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8192 points (L0...8191) by default (The latch range can be set for the devices, B, F, V, T, ST, C, D, and W.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eRUN\/PAUSE contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOne contact can be set up in X0 to X1FFF for each of RUN and PAUSE.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eClock function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYear, month, date, hour, minute, second, and day of week (automatic leap year detection) Accuracy: -2.96...+3.74 s (TYP. +1.42 s)\/d at 0 ˚C Accuracy: -3.18...+3.74 s (TYP. +1.50 s)\/d at 25 ˚C Accuracy: -13.20...+2.12 s (TYP. -3.54 s)\/d at 55 ˚C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInternal current consumption (5 V DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.33 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal dimensions - Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e98 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal dimensions - Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal dimensions - Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e89.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.20 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOperating ambient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0...55 ˚C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eStorage ambient temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...75 ˚C (The storage ambient temperature is -20 to 75 ˚C if the system includes the AnS\/A Series modules.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOperating ambient humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5...95 %RH, non-condensing (The operating ambient humidity and storage ambient humidity are 10 to 90 %RH if the system includes the AnS\/A Series modules.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eStorage ambient humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5...95 %RH, non-condensing (The operating ambient humidity and storage ambient humidity are 10 to 90 %RH if the system includes the AnS\/A Series modules.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eVibration resistance - Compliant with JIS B 3502 and IEC 61131-2 - Under intermittent vibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFrequency: 5...8.4 Hz, Half amplitude: 3.5 mm Frequency: 8.4...150 Hz, Constant acceleration: 9.8 m\/s 2 Sweep count: 10 times each in X, Y, Z directions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eVibration resistance - Compliant with JIS B 3502 and IEC 61131-2 - Under continuous vibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFrequency: 5...8.4 Hz, Half amplitude: 1.75 mm Frequency: 8.4...150 Hz, Constant acceleration: 4.9 m\/s 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eShock resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompliant with JIS B 3502 and IEC 61131-2 (147 m\/s 2 , 3 times each in 3 directions X, Y, Z)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOperating atmosphere\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo corrosive gases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOperating altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0...2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInstallation location\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInside a control panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOvervoltage category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eII or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEquipment class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eRelay symbol language, logic symbolic language, MELSAP3 (SFC), MELSAP-L, function block and structured text (ST)\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137180750077,"sku":"Q03UDCPU","price":114.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/Q03UDCPU.jpg?v=1742537217"},{"product_id":"a1sx40","title":"Mitsubishi A1SX40 | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi A1SX40\u003c\/h2\u003e \u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e A1SX40\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eMitsubishi PLC Module\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eMitsubishi Electric industrial automation product. Japanese quality, designed for reliable motion control and factory automation applications.\u003c\/p\u003e \u003ch3\u003eSpecifications:\u003c\/h3\u003e \u003ctable\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eType:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003ePLC Function Module\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eProduct Category:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003ePLCs\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eFunctions:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eAnalog I\/O, Temperature Control, High-Speed Counter\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eRecommended Use:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eProcess Control, Measurement\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eSuitable Space:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eControl Cabinet\u003c\/td\u003e \u003c\/tr\u003e \u003c\/table\u003e \u003ch3\u003eCompatibility:\u003c\/h3\u003e \u003cp\u003eMitsubishi products support MELSEC PLC platforms (FX, Q, iQ-R series) and MELSERVO servo systems. Compatible with CC-Link, CC-Link IE, EtherNet\/IP, and SSCNET networks.\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137180815613,"sku":"A1SX40","price":23.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/product_8846606565629.jpg?v=1784974455"},{"product_id":"qj61bt11n","title":"Mitsubishi QJ61BT11N | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi QJ61BT11N\u003c\/h2\u003e\n\u003cp\u003eMELSEC-Q Series QJ61BT11N\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTransmission speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e156 kbps\/625 kbps\/2.5 Mbps\/5 Mbps\/10 Mbps (selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum overall cable distance (Maximum transmission distance) - Ver. 1.10 - 156 kbps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1200 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum overall cable distance (Maximum transmission distance) - Ver. 1.10 - 625 kbps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e900 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum overall cable distance (Maximum transmission distance) - Ver. 1.10 - 2.5 Mbps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum overall cable distance (Maximum transmission distance) - Ver. 1.10 - 5 Mbps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e160 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum overall cable distance (Maximum transmission distance) - Ver. 1.10 - 10 Mbps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eStation type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManager station (Ver. 1 manager station or Ver. 2 manager station) Local station (Ver. 1 local station or Ver. 2 local station)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of connected stations - Manager station\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNumber of occupied stations - Local station\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1...4 stations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of link points per system - CC-Link Ver.1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote I\/O (RX, RY) : 2048 points Remote register (RWw) : 256 points Remote register (RWr) : 256 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum number of link points per system - CC-Link Ver.2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote I\/O (RX, RY) : 8192 points Remote register (RWw) : 2048 points Remote register (RWr) : 2048 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNumber of link points per station - CC-Link Ver.1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote I\/O (RX, RY) : 32 points (local station is 30 points) Remote register (RWw) : 4 points Remote register (RWr) : 4 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNumber of link points per station - CC-Link Ver.2 - Expanded cyclic setting: Single\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote I\/O (RX, RY) : 32 points (local station is 30 points) Remote register (RWw) : 4 points Remote register (RWr) : 4 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNumber of link points per station - CC-Link Ver.2 - Expanded cyclic setting: Double\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote I\/O (RX, RY) : 32 points (local station is 30 points) Remote register (RWw) : 8 points Remote register (RWr) : 8 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNumber of link points per station - CC-Link Ver.2 - Expanded cyclic setting: Quadruple\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote I\/O (RX, RY) : 64 points (local station is 62 points) Remote register (RWw) : 16 points Remote register (RWr) : 16 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNumber of link points per station - CC-Link Ver.2 - Expanded cyclic setting: Octuple\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote I\/O (RX, RY) : 128 points (local station is 126 points) Remote register (RWw) : 32 points Remote register (RWr) : 32 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eCommunication method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBroadcast polling method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSynchronization method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFrame synchronization method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEncoding method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNRZI method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNetwork topology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBus (RS-485)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eTransmission format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHDLC compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eError control system\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCRC (X 16 + X 12 + X 5 + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eCommunication cable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVer.1.10 compatible CC-Link dedicated cable CC-Link dedicated cable (Ver.1.00 compatible) CC-Link dedicated high-performance cable (Ver.1.00 compatible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eNumber of occupied I\/O points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 points (I\/O assignment: Intelligent 32 points)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInternal current consumption (5 V DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.46 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal dimensions - Height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e98 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal dimensions - Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eExternal dimensions - Depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.12 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eGeneral specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRefer to the general specifications of the CPU module.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137180913917,"sku":"QJ61BT11N","price":46.79,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/28_11_2022_10_57_20_QJ61BT11N_Mitsubishi.jpg?v=1742537223"},{"product_id":"hgsr702b","title":"Mitsubishi HGSR702B | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi HG-SR702B\u003c\/h2\u003e\n\u003cp\u003eAC Servos-MELSERVO HG-SR702B\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMELSERVO-J4 series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eModel name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHG-SR702B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eCompatible servo amplifier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRefer to \" Combinations of Rotary Servo Motors and Servo Amplifiers \" for compatible servo amplifier.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply capacity [kVA] *50\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eContinuous running duty *1 - Rated output [kW]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eContinuous running duty *1 - Rated torque [N・m] *2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum torque [N・m]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 (134) *3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eRated speed [r\/min] *1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum speed [r\/min] *1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePermissible instantaneous speed [r\/min]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3450\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower rate at continuous rated torque [kW\/s]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e69.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eRated current [A]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum current [A]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e83 (116) *3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMoment of inertia J [x 10 -4 kg・m 2 ]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e161\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eRecommended load to motor inertia ratio *4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 times or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSpeed・position detector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAbsolute\/incremental 22-bit encoder (resolution: 4194304 pulses\/rev)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePermanent magnet synchronous motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOil seal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone (Servo motors with an oil seal are available. (HG-SR_J))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eThermistor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInsulation class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e155 (F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eStructure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotally enclosed, natural cooling (IP rating: IP67) *5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Ambient temperature - Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C to 40 °C (non-freezing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Ambient temperature - Strage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-15 °C to 70 °C (non-freezing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Ambient humidity - Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 %RH to 80 %RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Ambient humidity - Strage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 %RH to 90 %RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Ambience\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndoors (no direct sunlight); no corrosive gas, inflammable gas, oil mist or dust\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m or less above sea level *6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Vibration resistance *50\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eX: 24.5 m\/s 2 Y: 29.4 m\/s 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eVibration rank\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eV10 *50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSatisfied standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRefer to \" Standards and certifications (by product) Products \" for compliance with global standards and regulations.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePermissible load for the shaft *50 - L [mm]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e79\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePermissible load for the shaft *50 - Radial [N]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2058\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePermissible load for the shaft *50 - Thrust [N]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e980\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMass [kg]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eElectromagnetic Brake *7 - Servo motor model name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHG-SR702B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eElectromagnetic Brake *7 - Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpring actuated type safety brake\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eElectromagnetic Brake *7 - Rated voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC (-10 % to 0 %)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eElectromagnetic Brake *7 - Power consumption [W] at 20 ﾟC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eElectromagnetic Brake *7 - Electromagnetic brake static friction torque [N・m]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e44 or higher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eElectromagnetic Brake *7 - Permissible braking work - Per braking [J]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eElectromagnetic Brake *7 - Permissible braking work - Per hour [J]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eElectromagnetic Brake *7 - Electromagnetic brake life *8 - Number of braking times\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eElectromagnetic Brake *7 - Electromagnetic brake life *8 - Work per braking [J]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eRefer to \" Combinations of Rotary Servo Motors and Servo Amplifiers \" for compatible servo amplifier.\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137180979453,"sku":"HGSR702B","price":1397.56,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/HGSR702B.jpg?v=1742537226"},{"product_id":"hgsr524k","title":"Mitsubishi HGSR524K | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi HG-SR524K\u003c\/h2\u003e\n\u003cp\u003eAC Servos-MELSERVO HG-SR524\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMELSERVO-J4 series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eModel name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHG-SR524\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eCompatible servo amplifier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRefer to \" Combinations of Rotary Servo Motors and Servo Amplifiers \" for compatible servo amplifier.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply capacity [kVA] *50\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eContinuous running duty *1 - Rated output [kW]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eContinuous running duty *1 - Rated torque [N・m] *2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum torque [N・m]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eRated speed [r\/min] *1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum speed [r\/min] *1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePermissible instantaneous speed [r\/min]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3450\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower rate at continuous rated torque [kW\/s]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.85\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eRated current [A]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum current [A]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMoment of inertia J [x 10 -4 kg・m 2 ]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eRecommended load to motor inertia ratio *4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 times or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSpeed・position detector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAbsolute\/incremental 22-bit encoder (resolution: 4194304 pulses\/rev)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePermanent magnet synchronous motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOil seal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone (Servo motors with an oil seal are available. (HG-SR_J))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eThermistor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInsulation class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e155 (F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eStructure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotally enclosed, natural cooling (IP rating: IP67) *5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Ambient temperature - Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C to 40 °C (non-freezing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Ambient temperature - Strage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-15 °C to 70 °C (non-freezing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Ambient humidity - Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 %RH to 80 %RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Ambient humidity - Strage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 %RH to 90 %RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Ambience\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndoors (no direct sunlight); no corrosive gas, inflammable gas, oil mist or dust\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m or less above sea level *6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Vibration resistance *50\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eX: 24.5 m\/s 2 Y: 24.5 m\/s 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eVibration rank\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eV10 *50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSatisfied standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRefer to \" Standards and certifications (by product) Products \" for compliance with global standards and regulations.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePermissible load for the shaft *50 - L [mm]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePermissible load for the shaft *50 - Radial [N]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e980\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePermissible load for the shaft *50 - Thrust [N]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e490\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMass [kg]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eRefer to \" Combinations of Rotary Servo Motors and Servo Amplifiers \" for compatible servo amplifier.\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137181044989,"sku":"HGSR524K","price":956.46,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/HGSR524K.jpg?v=1742537230"},{"product_id":"hgsr152k","title":"Mitsubishi HGSR152K | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi HG-SR152K\u003c\/h2\u003e\n\u003cp\u003eAC Servos-MELSERVO HG-SR152\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMELSERVO-J4 series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eModel name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHG-SR152\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eCompatible servo amplifier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRefer to \" Combinations of Rotary Servo Motors and Servo Amplifiers \" for compatible servo amplifier.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply capacity [kVA] *50\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eContinuous running duty *1 - Rated output [kW]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eContinuous running duty *1 - Rated torque [N・m] *2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum torque [N・m]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eRated speed [r\/min] *1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum speed [r\/min] *1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePermissible instantaneous speed [r\/min]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3450\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower rate at continuous rated torque [kW\/s]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eRated current [A]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum current [A]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e29\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMoment of inertia J [x 10 -4 kg・m 2 ]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eRecommended load to motor inertia ratio *4\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17 times or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSpeed・position detector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAbsolute\/incremental 22-bit encoder (resolution: 4194304 pulses\/rev)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePermanent magnet synchronous motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOil seal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone (Servo motors with an oil seal are available. (HG-SR_J))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eThermistor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInsulation class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e155 (F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eStructure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotally enclosed, natural cooling (IP rating: IP67) *5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Ambient temperature - Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C to 40 °C (non-freezing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Ambient temperature - Strage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-15 °C to 70 °C (non-freezing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Ambient humidity - Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 %RH to 80 %RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Ambient humidity - Strage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 %RH to 90 %RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Ambience\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndoors (no direct sunlight); no corrosive gas, inflammable gas, oil mist or dust\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m or less above sea level *6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Vibration resistance *50\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eX: 24.5 m\/s 2 Y: 24.5 m\/s 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eVibration rank\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eV10 *50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSatisfied standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRefer to \" Standards and certifications (by product) Products \" for compliance with global standards and regulations.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePermissible load for the shaft *50 - L [mm]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePermissible load for the shaft *50 - Radial [N]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e980\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePermissible load for the shaft *50 - Thrust [N]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e490\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMass [kg]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eRefer to \" Combinations of Rotary Servo Motors and Servo Amplifiers \" for compatible servo amplifier.\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137181110525,"sku":"HGSR152K","price":416.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/HGSR152K.jpg?v=1742537232"},{"product_id":"fx3g60mres","title":"FX3G-60MR\/ES Mitsubishi Electric","description":"\u003ch2\u003eMitsubishi FX3G60MRES\u003c\/h2\u003e \u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e FX3G60MRES\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eMitsubishi FX Series PLC\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eMitsubishi Electric industrial automation product. Japanese quality, designed for reliable motion control and factory automation applications.\u003c\/p\u003e \u003ch3\u003eSpecifications:\u003c\/h3\u003e \u003ctable\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eType:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eCompact Programmable Logic Controller\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eProduct Category:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003ePLCs\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eProduct Series:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eMitsubishi FX1N\/FX3G\/FX3U\/FX5U Series\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eFunctions:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eProgrammable Logic Control, I\/O Processing\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eCommunication Protocols:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eRS-422, RS-485, Ethernet, CC-Link\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eI\/O Capacity:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eUp to 256 I\/O points (model dependent)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003ePower Source:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eAC 100-240V \/ 24V DC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eRecommended Use:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eSmall-Medium Automation, Machine Control\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eSuitable Space:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eControl Cabinet, Machine Panel\u003c\/td\u003e \u003c\/tr\u003e \u003c\/table\u003e \u003ch3\u003eCompatibility:\u003c\/h3\u003e \u003cp\u003eMitsubishi products support MELSEC PLC platforms (FX, Q, iQ-R series) and MELSERVO servo systems. Compatible with CC-Link, CC-Link IE, EtherNet\/IP, and SSCNET networks.\u003c\/p\u003e","brand":"Mitsubishi Electric","offers":[{"title":"New","offer_id":46137181372669,"sku":"FX3G60MRES","price":193.01,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/FX3G60MRES.jpg?v=1742537241"},{"product_id":"hf-kp23jk-s11","title":"Mitsubishi HF-KP23JK-S11 | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi HF-KP23JK-S11\u003c\/h2\u003e \u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e HF-KP23JK-S11\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eMitsubishi Servo Motor\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eMitsubishi Electric industrial automation product. Japanese quality, designed for reliable motion control and factory automation applications.\u003c\/p\u003e \u003ch3\u003eSpecifications:\u003c\/h3\u003e \u003ctable\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eType:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eAC Servo Motor\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eProduct Category:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eServo Motors\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eProduct Series:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eMitsubishi HC\/HF\/HG Series\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eFunctions:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eHigh-Precision Motion Control, Positioning\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eControl Method:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eClosed-Loop Vector Control\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eEncoder Type:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eAbsolute \/ Incremental Encoder\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eRated Speed:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e1500-6000 rpm (model dependent)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eRecommended Use:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eIndustrial Automation, CNC Machines, Robotics, Packaging\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eSuitable Space:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eFactory Floor, Production Line\u003c\/td\u003e \u003c\/tr\u003e \u003c\/table\u003e \u003ch3\u003eCompatibility:\u003c\/h3\u003e \u003cp\u003eMitsubishi products support MELSEC PLC platforms (FX, Q, iQ-R series) and MELSERVO servo systems. Compatible with CC-Link, CC-Link IE, EtherNet\/IP, and SSCNET networks.\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137181503741,"sku":"HF-KP23JK-S11","price":150.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/HF-KP23JK-S11.jpg?v=1784944181"},{"product_id":"hc352s","title":"Mitsubishi HC352S | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi HC352S\u003c\/h2\u003e \u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e HC352S\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eMitsubishi Servo Motor\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eMitsubishi Electric industrial automation product. Japanese quality, designed for reliable motion control and factory automation applications.\u003c\/p\u003e \u003ch3\u003eSpecifications:\u003c\/h3\u003e \u003ctable\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eType:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eAC Servo Motor\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eProduct Category:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eServo Motors\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eProduct Series:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eMitsubishi HC\/HF\/HG Series\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eFunctions:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eHigh-Precision Motion Control, Positioning\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eControl Method:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eClosed-Loop Vector Control\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eEncoder Type:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eAbsolute \/ Incremental Encoder\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eRated Speed:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e1500-6000 rpm (model dependent)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eRecommended Use:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eIndustrial Automation, CNC Machines, Robotics, Packaging\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eSuitable Space:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eFactory Floor, Production Line\u003c\/td\u003e \u003c\/tr\u003e \u003c\/table\u003e \u003ch3\u003eCompatibility:\u003c\/h3\u003e \u003cp\u003eMitsubishi products support MELSEC PLC platforms (FX, Q, iQ-R series) and MELSERVO servo systems. Compatible with CC-Link, CC-Link IE, EtherNet\/IP, and SSCNET networks.\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137181569277,"sku":"HC352S","price":619.63,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/HC352S.jpg?v=1784944188"},{"product_id":"hg-sn102j-s100","title":"Mitsubishi HG-SN102J-S100 | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi HG-SN102J-S100\u003c\/h2\u003e \u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e HG-SN102J-S100\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eMitsubishi Servo Motor\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eMitsubishi Electric industrial automation product. Japanese quality, designed for reliable motion control and factory automation applications.\u003c\/p\u003e \u003ch3\u003eSpecifications:\u003c\/h3\u003e \u003ctable\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eType:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eAC Servo Motor\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eProduct Category:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eServo Motors\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eProduct Series:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eMitsubishi HC\/HF\/HG Series\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eFunctions:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eHigh-Precision Motion Control, Positioning\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eControl Method:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eClosed-Loop Vector Control\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eEncoder Type:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eAbsolute \/ Incremental Encoder\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eRated Speed:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e1500-6000 rpm (model dependent)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eRecommended Use:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eIndustrial Automation, CNC Machines, Robotics, Packaging\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eSuitable Space:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eFactory Floor, Production Line\u003c\/td\u003e \u003c\/tr\u003e \u003c\/table\u003e \u003ch3\u003eCompatibility:\u003c\/h3\u003e \u003cp\u003eMitsubishi products support MELSEC PLC platforms (FX, Q, iQ-R series) and MELSERVO servo systems. Compatible with CC-Link, CC-Link IE, EtherNet\/IP, and SSCNET networks.\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137181634813,"sku":"HG-SN102J-S100","price":263.19,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/HG-SN102J-S100.jpg?v=1784944196"},{"product_id":"hg-kr43","title":"Mitsubishi HG-KR43 | Industrial Automation Component","description":"\u003ch2\u003eMitsubishi HG-KR43\u003c\/h2\u003e\n\u003cp\u003eAC Servos-MELSERVO HG-KR43\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"4\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMELSERVO-J4 series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eModel name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHG-KR43\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eCompatible servo amplifier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRefer to \" Combinations of Rotary Servo Motors and Servo Amplifiers \" for compatible servo amplifier.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower supply capacity [kVA] *50\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eContinuous running duty *1 - Rated output [kW]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eContinuous running duty *1 - Rated torque [N・m] *2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum torque [N・m]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eRated speed [r\/min] *1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum speed [r\/min] *1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePermissible instantaneous speed [r\/min]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePower rate at continuous rated torque [kW\/s]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e43.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eRated current [A]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMaximum current [A]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMoment of inertia J [x 10 -4 kg・m 2 ]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.371\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eRecommended load to motor inertia ratio *3\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 times or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSpeed・position detector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAbsolute\/incremental 22-bit encoder (resolution: 4194304 pulses\/rev)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePermanent magnet synchronous motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eOil seal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone (Servo motors with an oil seal are available. (HG-KR_J))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eThermistor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eInsulation class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130 (B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eStructure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotally enclosed, natural cooling (IP rating: IP65) *4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Ambient temperature - Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 °C to 40 °C (non-freezing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Ambient temperature - Strage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-15 °C to 70 °C (non-freezing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Ambient humidity - Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 %RH to 80 %RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Ambient humidity - Strage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 %RH to 90 %RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Ambience\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndoors (no direct sunlight); no corrosive gas, inflammable gas, oil mist or dust\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Altitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m or less above sea level *5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eEnvironment *50 - Vibration resistance *50\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eX: 49 m\/s 2 Y: 49 m\/s 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eVibration rank\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eV10 *50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eSatisfied standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRefer to \" Standards and certifications (by product) Products \" for compliance with global standards and regulations.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePermissible load for the shaft *50 - L [mm]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePermissible load for the shaft *50 - Radial [N]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e245\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003ePermissible load for the shaft *50 - Thrust [N]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e98\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#f0f0f0;\"\u003e\u003cstrong\u003eMass [kg]\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eRefer to \" Combinations of Rotary Servo Motors and Servo Amplifiers \" for compatible servo amplifier.\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"New","offer_id":46137181733117,"sku":"HG-KR43","price":37.11,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/HG-KR43.jpg?v=1784944206"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/collections\/logo_dda748df-d8b9-4734-8804-0bf64a7c3381.png?v=1782955901","url":"https:\/\/shly-plc.com\/collections\/mitsubishi.oembed?page=9","provider":"Lianyou PLC","version":"1.0","type":"link"}