{"title":"B\u0026R","description":"\u003cp\u003eShop B\u0026amp;R industrial automation products including X20 I\/O modules, Power Panel HMI devices, ACOPOS servo drives, and automation controllers. Quality B\u0026amp;R spare parts with worldwide shipping from Shanghai.\u003c\/p\u003e","products":[{"product_id":"x20bc1083","title":"B\u0026R X20BC1083 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e I\/O systems \u0026gt; X20 System \u0026gt; Expandable bus controllers\u003c\/p\u003e\n\u003cp\u003ePOWERLINK I\/O configuration and firmware update via the fieldbus Integrated hub for efficient cabling Up to 2 slots for interface modules The bus controller makes it possible to connect X2X Link I\/O nodes to POWERLINK.\u003c\/p\u003e\n\u003cp\u003eIt is also possible to operate the X2X Link cycle synchronously 1:1 or synchronous to POWERLINK using a prescaler.\u003c\/p\u003e\n\u003cp\u003ePOWERLINK is a standard protocol for Fast Ethernet equipped with hard real-time characteristics.\u003c\/p\u003e\n\u003cp\u003eThe POWERLINK Standardization Group (EPSG) ensures that the standard remains open and is continually developed:: www.ethernet-powerlink.org .\u003c\/p\u003e\n\u003cp\u003eThe bus modules expanded to the left allow connection of up to 2 interface modules in addition to the bus controller.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eShort description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBus controller = POWERLINK (V1\/V2) controlled node with up to 2 slots for interface modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDiagnostics\u003c\/li\u003e\n\u003cli\u003eModule status = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003eBus function = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003eSupport\u003c\/li\u003e\n\u003cli\u003eDynamic node allocation (DNA) = Yes\u003c\/li\u003e\n\u003cli\u003ePower consumption\u003c\/li\u003e\n\u003cli\u003eBus = 2 W\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = In preparation\u003c\/li\u003e\n\u003cli\u003eATEX = Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X\u003c\/li\u003e\n\u003cli\u003eUL = cULus E115267 Industrial control equipment\u003c\/li\u003e\n\u003cli\u003eHazLoc = cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5\u003c\/li\u003e\n\u003cli\u003eDNV = Temperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck)\u003c\/li\u003e\n\u003cli\u003eCCS = Yes\u003c\/li\u003e\n\u003cli\u003eLR = ENV1\u003c\/li\u003e\n\u003cli\u003eKR = Yes\u003c\/li\u003e\n\u003cli\u003eABS = Yes\u003c\/li\u003e\n\u003cli\u003eBV = EC33B Temperature: 5 - 55°C Vibration: 4 g EMC: Bridge and open deck\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0x2268\u003c\/li\u003e\n\u003cli\u003eStatus indicators = Module status, bus function\u003c\/li\u003e\n\u003cli\u003eAdditional power dissipation caused by actuators (resistive) [W] = -\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInterfaces\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTransfer\u003c\/li\u003e\n\u003cli\u003ePhysical layer = 100BASE-TX\u003c\/li\u003e\n\u003cli\u003eHalf-duplex = Yes\u003c\/li\u003e\n\u003cli\u003eFull-duplex = No\u003c\/li\u003e\n\u003cli\u003eAutonegotiation = Yes\u003c\/li\u003e\n\u003cli\u003eAuto-MDI\/MDIX = Yes\u003c\/li\u003e\n\u003cli\u003eMin. cycle time\u003c\/li\u003e\n\u003cli\u003eFieldbus = 200 μs\u003c\/li\u003e\n\u003cli\u003eX2X Link = 200 μs\u003c\/li\u003e\n\u003cli\u003eCyclic data\u003c\/li\u003e\n\u003cli\u003eInput data = Max. 1488 bytes\u003c\/li\u003e\n\u003cli\u003eOutput data = Max. 1488 bytes\u003c\/li\u003e\n\u003cli\u003eFieldbus = POWERLINK (V1\/V2) controlled node\u003c\/li\u003e\n\u003cli\u003eType = Type 2\u003c\/li\u003e\n\u003cli\u003eVariant = 2x shielded RJ45 (hub)\u003c\/li\u003e\n\u003cli\u003eLine length = Max. 100 m between 2 stations (segment length)\u003c\/li\u003e\n\u003cli\u003eTransfer rate = 100 Mbit\/s\u003c\/li\u003e\n\u003cli\u003eHub propagation delay = 0.96 to 1 µs\u003c\/li\u003e\n\u003cli\u003eSynchronization between bus systems possible = Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation = POWERLINK isolated from bus and I\/O\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperating conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMounting orientation\u003c\/li\u003e\n\u003cli\u003eHorizontal = Yes\u003c\/li\u003e\n\u003cli\u003eVertical = Yes\u003c\/li\u003e\n\u003cli\u003eInstallation elevation above sea level\u003c\/li\u003e\n\u003cli\u003e0 to 2000 m = No limitation\u003c\/li\u003e\n\u003cli\u003e\u0026gt;2000 m = Reduction of ambient temperature by 0.5°C per 100 m\u003c\/li\u003e\n\u003cli\u003eDegree of protection per EN 60529 = IP20\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature\u003c\/li\u003e\n\u003cli\u003eOperation\u003c\/li\u003e\n\u003cli\u003eHorizontal mounting orientation = -25 to 60°C\u003c\/li\u003e\n\u003cli\u003eVertical mounting orientation = -25 to 50°C\u003c\/li\u003e\n\u003cli\u003eDerating = -\u003c\/li\u003e\n\u003cli\u003eStorage = -40 to 85°C\u003c\/li\u003e\n\u003cli\u003eTransport = -40 to 85°C\u003c\/li\u003e\n\u003cli\u003eRelative humidity\u003c\/li\u003e\n\u003cli\u003eOperation = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003cli\u003eStorage = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003cli\u003eTransport = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePitch\u003c\/li\u003e\n\u003cli\u003eX20BB81 = 62.5 +0.2 mm\u003c\/li\u003e\n\u003cli\u003eX20BB82 = 87.5 +0.2 mm\u003c\/li\u003e\n\u003cli\u003eNote = Order 1x terminal block X20TB12 separately. Order 1x power supply module X20PS9400 or X20PS9402 separately. Order 1x bus base X20BB81 or X20BB82 separately.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"Never Used Surplus","offer_id":70984800043261,"sku":"X20BC1083","price":954.64,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/X20BC1083.jpg?v=1785724433"},{"product_id":"x20bb80","title":"B\u0026R X20BB80 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e I\/O systems \u0026gt; X20 System \u0026gt; System modules for bus controllers\u003c\/p\u003e\n\u003cp\u003eBus base The following modules are used on the bus module: Base module (BC, HB, etc.) Supply module The left and right end cover plates are included in delivery.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eShort description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBus module = Bus base - Backplane for bus controller fieldbus interface and bus controller power supply module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower consumption\u003c\/li\u003e\n\u003cli\u003eBus = 0.25 W\u003c\/li\u003e\n\u003cli\u003eInternal I\/O = -\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = In preparation\u003c\/li\u003e\n\u003cli\u003eATEX = Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X\u003c\/li\u003e\n\u003cli\u003eUL = cULus E115267 Industrial control equipment\u003c\/li\u003e\n\u003cli\u003eHazLoc = cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5\u003c\/li\u003e\n\u003cli\u003eDNV = Temperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck)\u003c\/li\u003e\n\u003cli\u003eCCS = Yes\u003c\/li\u003e\n\u003cli\u003eLR = ENV1\u003c\/li\u003e\n\u003cli\u003eKR = Yes\u003c\/li\u003e\n\u003cli\u003eABS = Yes\u003c\/li\u003e\n\u003cli\u003eBV = EC33B Temperature: 5 - 55°C Vibration: 4 g EMC: Bridge and open deck\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eAdditional power dissipation caused by actuators (resistive) [W] = -\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eI\/O power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNominal voltage = 24 VDC\u003c\/li\u003e\n\u003cli\u003ePermissible contact load = 10 A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperating conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMounting orientation\u003c\/li\u003e\n\u003cli\u003eHorizontal = Yes\u003c\/li\u003e\n\u003cli\u003eVertical = Yes\u003c\/li\u003e\n\u003cli\u003eInstallation elevation above sea level\u003c\/li\u003e\n\u003cli\u003e0 to 2000 m = No limitation\u003c\/li\u003e\n\u003cli\u003e\u0026gt;2000 m = Reduction of ambient temperature by 0.5°C per 100 m\u003c\/li\u003e\n\u003cli\u003eMaximum = 4000 m\u003c\/li\u003e\n\u003cli\u003eDegree of protection per EN 60529 = IP20\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature\u003c\/li\u003e\n\u003cli\u003eOperation\u003c\/li\u003e\n\u003cli\u003eHorizontal mounting orientation = -25 to 60°C\u003c\/li\u003e\n\u003cli\u003eVertical mounting orientation = -25 to 50°C\u003c\/li\u003e\n\u003cli\u003eDerating = -\u003c\/li\u003e\n\u003cli\u003eStorage = -40 to 85°C\u003c\/li\u003e\n\u003cli\u003eTransport = -40 to 85°C\u003c\/li\u003e\n\u003cli\u003eRelative humidity\u003c\/li\u003e\n\u003cli\u003eOperation = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003cli\u003eStorage = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003cli\u003eTransport = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNote = Left and right X20 end cover plates included in delivery\u003c\/li\u003e\n\u003cli\u003ePitch = 37.5 +0.2 mm\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"Never Used Surplus","offer_id":70984800567549,"sku":"X20BB80","price":333.64,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/X20BB80.jpg?v=1785724425"},{"product_id":"x20dif371","title":"B\u0026R X20DIF371 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e I\/O systems \u0026gt; X20 System \u0026gt; Digital inputs\u003c\/p\u003e\n\u003cp\u003e16 digital inputs Sink connection 1-wire connections Software input filter can be configured for entire module The module is equipped with 16 inputs for 1-wire connections.\u003c\/p\u003e\n\u003cp\u003eThe module is designed for sink input wiring.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eShort description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eI\/O module = 16 digital inputs 24 VDC for 1-wire connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDiagnostics\u003c\/li\u003e\n\u003cli\u003eModule run\/error = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003ePower consumption\u003c\/li\u003e\n\u003cli\u003eBus = 0.18 W\u003c\/li\u003e\n\u003cli\u003eInternal I\/O = 1.47 W\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = In preparation\u003c\/li\u003e\n\u003cli\u003eATEX = Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X\u003c\/li\u003e\n\u003cli\u003eUL = cULus E115267 Industrial control equipment\u003c\/li\u003e\n\u003cli\u003eHazLoc = cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5\u003c\/li\u003e\n\u003cli\u003eDNV = Temperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck)\u003c\/li\u003e\n\u003cli\u003eCCS = Yes\u003c\/li\u003e\n\u003cli\u003eLR = ENV1\u003c\/li\u003e\n\u003cli\u003eKR = Yes\u003c\/li\u003e\n\u003cli\u003eABS = Yes\u003c\/li\u003e\n\u003cli\u003eBV = EC33B Temperature: 5 - 55°C Vibration: 4 g EMC: Bridge and open deck\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0xC0E8\u003c\/li\u003e\n\u003cli\u003eStatus indicators = I\/O function per channel, operating state, module status\u003c\/li\u003e\n\u003cli\u003eAdditional power dissipation caused by actuators (resistive) [W] = -\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput filter\u003c\/li\u003e\n\u003cli\u003eHardware = ≤100 μs\u003c\/li\u003e\n\u003cli\u003eSoftware = Default 1 ms, configurable between 0 and 25 ms in 0.2 ms increments\u003c\/li\u003e\n\u003cli\u003eSimultaneity\u003c\/li\u003e\n\u003cli\u003eWith 24 V I\/O power supply = 100% (16 channels)\u003c\/li\u003e\n\u003cli\u003eWith 28.8 V I\/O power supply = 75% (12 channels)\u003c\/li\u003e\n\u003cli\u003eSwitching threshold\u003c\/li\u003e\n\u003cli\u003eLow = \u0026lt;5 VDC\u003c\/li\u003e\n\u003cli\u003eHigh = \u0026gt;15 VDC\u003c\/li\u003e\n\u003cli\u003eNominal voltage = 24 VDC\u003c\/li\u003e\n\u003cli\u003eInput characteristics per EN 61131-2 = Type 1\u003c\/li\u003e\n\u003cli\u003eInput voltage = 24 VDC -15% \/ +20%\u003c\/li\u003e\n\u003cli\u003eInput current at 24 VDC = Typ. 2.68 mA\u003c\/li\u003e\n\u003cli\u003eInput circuit = Sink\u003c\/li\u003e\n\u003cli\u003eConnection type = 1-wire connections\u003c\/li\u003e\n\u003cli\u003eInput resistance = Typ. 8.9 kΩ\u003c\/li\u003e\n\u003cli\u003eInsulation voltage between channel and bus = 500 V eff\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation = Channel isolated from bus Channel not isolated from channel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperating conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMounting orientation\u003c\/li\u003e\n\u003cli\u003eHorizontal = Yes\u003c\/li\u003e\n\u003cli\u003eVertical = Yes\u003c\/li\u003e\n\u003cli\u003eInstallation elevation above sea level\u003c\/li\u003e\n\u003cli\u003e0 to 2000 m = No limitation\u003c\/li\u003e\n\u003cli\u003e\u0026gt;2000 m = Reduction of ambient temperature by 0.5°C per 100 m\u003c\/li\u003e\n\u003cli\u003eDegree of protection per EN 60529 = IP20\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature\u003c\/li\u003e\n\u003cli\u003eOperation\u003c\/li\u003e\n\u003cli\u003eHorizontal mounting orientation = -25 to 60°C\u003c\/li\u003e\n\u003cli\u003eVertical mounting orientation = -25 to 50°C\u003c\/li\u003e\n\u003cli\u003eDerating = See section \"Derating\".\u003c\/li\u003e\n\u003cli\u003eStorage = -40 to 85°C\u003c\/li\u003e\n\u003cli\u003eTransport = -40 to 85°C\u003c\/li\u003e\n\u003cli\u003eRelative humidity\u003c\/li\u003e\n\u003cli\u003eOperation = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003cli\u003eStorage = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003cli\u003eTransport = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNote = Order 1x terminal block X20TB1F separately. Order 1x bus module X20BM11 separately.\u003c\/li\u003e\n\u003cli\u003ePitch = 12.5 +0.2 mm\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160950460669,"sku":"X20DIF371","price":371.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/X20DIF371.jpg?v=1785723968"},{"product_id":"x20ps9400","title":"B\u0026R X20PS9400 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e I\/O systems \u0026gt; X20 System \u0026gt; System modules for bus controllers\u003c\/p\u003e\n\u003cp\u003eSupply for the bus controller, X2X Link and internal I\/O supply Feed and bus controller \/ X2X Link supply electrically isolated Redundancy of bus controller \/ X2X Link supply possible by operating multiple supply modules simultaneously Service interface (RS232) The supply module is used together with an X20 bus controller.\u003c\/p\u003e\n\u003cp\u003eIt is equipped with a feed for the bus controller, the X2X Link and the internal I\/O supply.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eShort description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower supply module = 24 VDC supply module for bus controller, X2X Link power supply and I\/O\u003c\/li\u003e\n\u003cli\u003eInterfaces = 1x RS232 service interface\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDiagnostics\u003c\/li\u003e\n\u003cli\u003eModule run\/error = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003eRS232 data transfer = Yes, using LED status indicator\u003c\/li\u003e\n\u003cli\u003eOverload = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003ePower consumption\u003c\/li\u003e\n\u003cli\u003eInternal I\/O = 0.6 W\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = In preparation\u003c\/li\u003e\n\u003cli\u003eATEX = Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X\u003c\/li\u003e\n\u003cli\u003eUL = cULus E115267 Industrial control equipment\u003c\/li\u003e\n\u003cli\u003eHazLoc = cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5\u003c\/li\u003e\n\u003cli\u003eDNV = Temperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck)\u003c\/li\u003e\n\u003cli\u003eCCS = Yes\u003c\/li\u003e\n\u003cli\u003eLR = ENV1\u003c\/li\u003e\n\u003cli\u003eKR = Yes\u003c\/li\u003e\n\u003cli\u003eABS = Yes\u003c\/li\u003e\n\u003cli\u003eBV = EC33B Temperature: 5 - 55°C Vibration: 4 g EMC: Bridge and open deck\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0x1F8C\u003c\/li\u003e\n\u003cli\u003eStatus indicators = Overload, operating status, module status, RS232\u003c\/li\u003e\n\u003cli\u003ePower consumption for X2X Link power supply = 1.42 W\u003c\/li\u003e\n\u003cli\u003eAdditional power dissipation caused by actuators (resistive) [W] = -\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBus controller \/ X2X Link power supply input\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput voltage = 24 VDC -15% \/ +20%\u003c\/li\u003e\n\u003cli\u003eInput current = Max. 0.7 A\u003c\/li\u003e\n\u003cli\u003eFuse = Integrated, cannot be replaced\u003c\/li\u003e\n\u003cli\u003eReverse polarity protection = Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBus controller \/ X2X Link power supply output\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNominal output power = 7 W\u003c\/li\u003e\n\u003cli\u003eParallel connection = Yes\u003c\/li\u003e\n\u003cli\u003eRedundant operation = Yes\u003c\/li\u003e\n\u003cli\u003eOverload characteristics = Short-circuit proof, temporary overload\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInput I\/O power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput voltage = 24 VDC -15% \/ +20%\u003c\/li\u003e\n\u003cli\u003eFuse = Required line fuse: Max. 10 A, slow-blow\u003c\/li\u003e\n\u003cli\u003eReverse polarity protection = No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOutput I\/O power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNominal output voltage = 24 VDC\u003c\/li\u003e\n\u003cli\u003eBehavior on short circuit = Required line fuse\u003c\/li\u003e\n\u003cli\u003ePermissible contact load = 10 A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInterfaces\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eService interface\u003c\/li\u003e\n\u003cli\u003eSignal = RS232\u003c\/li\u003e\n\u003cli\u003eVariant = Connection made using 12-pin terminal block X20TB12\u003c\/li\u003e\n\u003cli\u003eMax. transfer rate = 115.2 kbit\/s\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation = BC\/X2X Link supply isolated from BC\/X2X Link power supply I\/O supply not isolated from I\/O power supply, and RS232 not isolated from bus\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperating conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMounting orientation\u003c\/li\u003e\n\u003cli\u003eHorizontal = Yes\u003c\/li\u003e\n\u003cli\u003eVertical = Yes\u003c\/li\u003e\n\u003cli\u003eInstallation elevation above sea level\u003c\/li\u003e\n\u003cli\u003e0 to 2000 m = No limitation\u003c\/li\u003e\n\u003cli\u003e\u0026gt;2000 m = Reduction of ambient temperature by 0.5°C per 100 m\u003c\/li\u003e\n\u003cli\u003eDegree of protection per EN 60529 = IP20\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature\u003c\/li\u003e\n\u003cli\u003eOperation\u003c\/li\u003e\n\u003cli\u003eHorizontal mounting orientation = -25 to 60°C\u003c\/li\u003e\n\u003cli\u003eVertical mounting orientation = -25 to 50°C\u003c\/li\u003e\n\u003cli\u003eDerating = See section \"Derating\".\u003c\/li\u003e\n\u003cli\u003eStorage = -40 to 85°C\u003c\/li\u003e\n\u003cli\u003eTransport = -40 to 85°C\u003c\/li\u003e\n\u003cli\u003eRelative humidity\u003c\/li\u003e\n\u003cli\u003eOperation = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003cli\u003eStorage = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003cli\u003eTransport = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNote = Order 1x terminal block X20TB12 separately. Order 1x bus base X20BB8x separately.\u003c\/li\u003e\n\u003cli\u003ePitch = 12.5 +0.2 mm\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160951378173,"sku":"X20PS9400","price":387.59,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/X20PS9400.jpg?v=1785724235"},{"product_id":"x20cp1586","title":"B\u0026R X20CP1586 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e PLC systems \u0026gt; X20 System \u0026gt; X20 PLC\u003c\/p\u003e\n\u003cp\u003eIntel Atom 1.6 GHz processor with an additional I\/O processor Onboard Ethernet, POWERLINK with poll response chaining and USB 1 slot for modular interface expansion CompactFlash as removable application memory 512 MB DDR2 SDRAM Fanless The X20CP1586 is a powerful controller for the X20 system.\u003c\/p\u003e\n\u003cp\u003eThis controller is especially useful for applications that require short cycle times, have to process very large amounts of data or carry out floating point operations.\u003c\/p\u003e\n\u003cp\u003eIt is clocked at 1.6 GHz and equipped with 512 MB DDR2 SDRAM.\u003c\/p\u003e\n\u003cp\u003eUSB, Ethernet, POWERLINK and removable CompactFlash are all included as standard features.\u003c\/p\u003e\n\u003cp\u003eThe standard Ethernet interface is capable of handling communication in the gigabit range.\u003c\/p\u003e\n\u003cp\u003eFor even more real-time network performance, the onboard POWERLINK interface supports poll response chaining mode (PRC).\u003c\/p\u003e\n\u003cp\u003eThe controller is equipped with one slot available for X20 communication modules.\u003c\/p\u003e\n\u003cp\u003eVarious bus and network systems can easily be integrated into the X20 system through the use of communication modules.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eShort description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInterfaces = 1x RS232, 1x Ethernet, 1x POWERLINK (V1\/V2), 2x USB, 1x X2X Link\u003c\/li\u003e\n\u003cli\u003eSystem module = Controller\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDiagnostics\u003c\/li\u003e\n\u003cli\u003eBattery = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003eCPU function = Yes, using LED status indicator\u003c\/li\u003e\n\u003cli\u003eCompactFlash = Yes, using LED status indicator\u003c\/li\u003e\n\u003cli\u003eEthernet = Yes, using LED status indicator\u003c\/li\u003e\n\u003cli\u003ePOWERLINK = Yes, using LED status indicator\u003c\/li\u003e\n\u003cli\u003eTemperature = Yes, using software register\u003c\/li\u003e\n\u003cli\u003eSupport\u003c\/li\u003e\n\u003cli\u003eController redundancy = No\u003c\/li\u003e\n\u003cli\u003eStorage health data support = Yes\u003c\/li\u003e\n\u003cli\u003eACOPOS support = Yes\u003c\/li\u003e\n\u003cli\u003eVisual Components support = Yes\u003c\/li\u003e\n\u003cli\u003ePower consumption\u003c\/li\u003e\n\u003cli\u003eInternal I\/O = 0.6 W\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = Non-compliant\u003c\/li\u003e\n\u003cli\u003eATEX = Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X\u003c\/li\u003e\n\u003cli\u003eUL = cULus E115267 Industrial control equipment\u003c\/li\u003e\n\u003cli\u003eHazLoc = cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5\u003c\/li\u003e\n\u003cli\u003eDNV = Temperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck)\u003c\/li\u003e\n\u003cli\u003eCCS = Yes\u003c\/li\u003e\n\u003cli\u003eLR = ENV1\u003c\/li\u003e\n\u003cli\u003eKR = Yes\u003c\/li\u003e\n\u003cli\u003eABS = Yes\u003c\/li\u003e\n\u003cli\u003eBV = EC33B Temperature: 5 - 55°C Vibration: 4 g EMC: Bridge and open deck\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0xC3B0\u003c\/li\u003e\n\u003cli\u003eCooling = Fanless\u003c\/li\u003e\n\u003cli\u003eStatus indicators = CPU function, Ethernet, POWERLINK, CompactFlash, battery\u003c\/li\u003e\n\u003cli\u003ePower consumption without interface module and USB = 9.7 W\u003c\/li\u003e\n\u003cli\u003ePower consumption for X2X Link power supply = 1.42 W\u003c\/li\u003e\n\u003cli\u003eAdditional power dissipation caused by actuators (resistive) [W] = -\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCPU and X2X Link power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput voltage = 24 VDC -15% \/ +20%\u003c\/li\u003e\n\u003cli\u003eInput current = Max. 1.5 A\u003c\/li\u003e\n\u003cli\u003eFuse = Integrated, cannot be replaced\u003c\/li\u003e\n\u003cli\u003eReverse polarity protection = Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eX2X Link power supply output\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNominal output power = 7 W\u003c\/li\u003e\n\u003cli\u003eParallel connection = Yes\u003c\/li\u003e\n\u003cli\u003eRedundant operation = Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInput I\/O power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput voltage = 24 VDC -15% \/ +20%\u003c\/li\u003e\n\u003cli\u003eFuse = Required line fuse: Max. 10 A, slow-blow\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOutput I\/O power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNominal output voltage = 24 VDC\u003c\/li\u003e\n\u003cli\u003ePermissible contact load = 10 A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePower supply - General information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDiagnostics\u003c\/li\u003e\n\u003cli\u003eRS232 data transfer = Yes, using LED status indicator\u003c\/li\u003e\n\u003cli\u003eModule run\/error = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003eOverload = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eI\/O supply - I\/O power supply = No\u003c\/li\u003e\n\u003cli\u003eCPU\/X2X Link supply - CPU\/X2X Link power supply = Yes\u003c\/li\u003e\n\u003cli\u003eStatus indicators = Overload, operating status, module status, RS232 data transfer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eController\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProcessor\u003c\/li\u003e\n\u003cli\u003eL1 cache\u003c\/li\u003e\n\u003cli\u003eData code = 24 kB\u003c\/li\u003e\n\u003cli\u003eProgram code = 32 kB\u003c\/li\u003e\n\u003cli\u003eType = Atom E680T\u003c\/li\u003e\n\u003cli\u003eClock frequency = 1.6 GHz\u003c\/li\u003e\n\u003cli\u003eL2 cache = 512 kB\u003c\/li\u003e\n\u003cli\u003eData buffering\u003c\/li\u003e\n\u003cli\u003eBattery monitoring = Yes\u003c\/li\u003e\n\u003cli\u003eLithium battery = Min. 2 years at 23°C ambient temperature\u003c\/li\u003e\n\u003cli\u003eStandard memory\u003c\/li\u003e\n\u003cli\u003eRAM = 512 MB DDR2 SDRAM\u003c\/li\u003e\n\u003cli\u003eUser RAM = 1 MB SRAM\u003c\/li\u003e\n\u003cli\u003eCompactFlash slot = 1\u003c\/li\u003e\n\u003cli\u003eReal-time clock = Nonvolatile, resolution 1 s, -10 to 10 ppm accuracy at 25°C\u003c\/li\u003e\n\u003cli\u003eFloating point unit (FPU) = Yes\u003c\/li\u003e\n\u003cli\u003eIntegrated I\/O processor = Processes I\/O data points in the background\u003c\/li\u003e\n\u003cli\u003eModular interface slots = 1\u003c\/li\u003e\n\u003cli\u003eRemanent variables = Max. 1 MB\u003c\/li\u003e\n\u003cli\u003eShortest task class cycle time = 100 µs\u003c\/li\u003e\n\u003cli\u003eTypical instruction cycle time = 0.0027 µs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInterfaces\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInterface IF1\u003c\/li\u003e\n\u003cli\u003eSignal = RS232\u003c\/li\u003e\n\u003cli\u003eVariant = Connection made using 12-pin terminal block X20TB12\u003c\/li\u003e\n\u003cli\u003eMax. distance = 900 m\u003c\/li\u003e\n\u003cli\u003eTransfer rate = Max. 115.2 kbit\/s\u003c\/li\u003e\n\u003cli\u003eInterface IF2\u003c\/li\u003e\n\u003cli\u003eTransfer\u003c\/li\u003e\n\u003cli\u003ePhysical layer = 10BASE-T\/100BASE-TX\/1000BASE-T\u003c\/li\u003e\n\u003cli\u003eHalf-duplex = Yes\u003c\/li\u003e\n\u003cli\u003eFull-duplex = Yes\u003c\/li\u003e\n\u003cli\u003eAutonegotiation = Yes\u003c\/li\u003e\n\u003cli\u003eAuto-MDI\/MDIX = Yes\u003c\/li\u003e\n\u003cli\u003eSignal = Ethernet\u003c\/li\u003e\n\u003cli\u003eVariant = 1x RJ45 shielded\u003c\/li\u003e\n\u003cli\u003eLine length = Max. 100 m between 2 stations (segment length)\u003c\/li\u003e\n\u003cli\u003eTransfer rate = 10\/100\/1000 Mbit\/s\u003c\/li\u003e\n\u003cli\u003eInterface IF3\u003c\/li\u003e\n\u003cli\u003ePhysical layer = 100BASE-TX\u003c\/li\u003e\n\u003cli\u003eFull-duplex = POWERLINK mode: No \/ Ethernet mode: Yes\u003c\/li\u003e\n\u003cli\u003eFieldbus = POWERLINK (V1\/V2) managing or controlled node\u003c\/li\u003e\n\u003cli\u003eType = Type 4\u003c\/li\u003e\n\u003cli\u003eTransfer rate = 100 Mbit\/s\u003c\/li\u003e\n\u003cli\u003eInterface IF4\u003c\/li\u003e\n\u003cli\u003eType = USB 1.1\/2.0\u003c\/li\u003e\n\u003cli\u003eVariant = Type A\u003c\/li\u003e\n\u003cli\u003eMax. output current = 0.5 A\u003c\/li\u003e\n\u003cli\u003eInterface IF5\u003c\/li\u003e\n\u003cli\u003eInterface IF6\u003c\/li\u003e\n\u003cli\u003eFieldbus = X2X Link master\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"Never Used Surplus","offer_id":70984801321213,"sku":"X20CP1586","price":3377.77,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/X20CP1586.jpg?v=1785724460"},{"product_id":"x20if1082","title":"B\u0026R X20IF1082 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e I\/O systems \u0026gt; X20 System \u0026gt; X20 interface module communication\u003c\/p\u003e\n\u003cp\u003ePOWERLINK for real-time Ethernet communication Integrated hub for efficient cabling Configurable ring redundancy The interface module is used for application-specific expansion of the X20 controllers.\u003c\/p\u003e\n\u003cp\u003eIt is equipped with a POWERLINK interface. The interface has two RJ45 sockets. Both connections lead to an integrated hub.\u003c\/p\u003e\n\u003cp\u003eThis makes it easy to create daisy-chain connections using POWERLINK.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eShort description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCommunication module = 1x POWERLINK (V1\/V2) managing or controlled node\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDiagnostics\u003c\/li\u003e\n\u003cli\u003eModule status = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003eBus function = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = In preparation\u003c\/li\u003e\n\u003cli\u003eATEX = Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X\u003c\/li\u003e\n\u003cli\u003eUL = cULus E115267 Industrial control equipment\u003c\/li\u003e\n\u003cli\u003eHazLoc = cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5\u003c\/li\u003e\n\u003cli\u003eDNV = Temperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck)\u003c\/li\u003e\n\u003cli\u003eCCS = Yes\u003c\/li\u003e\n\u003cli\u003eLR = ENV1\u003c\/li\u003e\n\u003cli\u003eKR = Yes\u003c\/li\u003e\n\u003cli\u003eABS = Yes\u003c\/li\u003e\n\u003cli\u003eBV = EC33B Temperature: 5 - 55°C Vibration: 4 g EMC: Bridge and open deck\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0x1F1F\u003c\/li\u003e\n\u003cli\u003eStatus indicators = Module status, bus function\u003c\/li\u003e\n\u003cli\u003ePower consumption = 2 W\u003c\/li\u003e\n\u003cli\u003eAdditional power dissipation caused by actuators (resistive) [W] = -\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInterfaces\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTransfer\u003c\/li\u003e\n\u003cli\u003ePhysical layer = 100BASE-TX\u003c\/li\u003e\n\u003cli\u003eHalf-duplex = Yes\u003c\/li\u003e\n\u003cli\u003eFull-duplex = No\u003c\/li\u003e\n\u003cli\u003eAutonegotiation = Yes\u003c\/li\u003e\n\u003cli\u003eAuto-MDI\/MDIX = Yes\u003c\/li\u003e\n\u003cli\u003eFieldbus = POWERLINK (V1\/V2) managing or controlled node\u003c\/li\u003e\n\u003cli\u003eType = Type 3\u003c\/li\u003e\n\u003cli\u003eVariant = 2x shielded RJ45 (hub)\u003c\/li\u003e\n\u003cli\u003eLine length = Max. 100 m between 2 stations (segment length)\u003c\/li\u003e\n\u003cli\u003eTransfer rate = 100 Mbit\/s\u003c\/li\u003e\n\u003cli\u003eHub propagation delay = 0.96 to 1 µs\u003c\/li\u003e\n\u003cli\u003eController = POWERLINK MAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation = PLC isolated from POWERLINK (X1 and X2)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperating conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMounting orientation\u003c\/li\u003e\n\u003cli\u003eHorizontal = Yes\u003c\/li\u003e\n\u003cli\u003eVertical = Yes\u003c\/li\u003e\n\u003cli\u003eInstallation elevation above sea level\u003c\/li\u003e\n\u003cli\u003e0 to 2000 m = No limitation\u003c\/li\u003e\n\u003cli\u003e\u0026gt;2000 m = Reduction of ambient temperature by 0.5°C per 100 m\u003c\/li\u003e\n\u003cli\u003eDegree of protection per EN 60529 = IP20\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature\u003c\/li\u003e\n\u003cli\u003eOperation\u003c\/li\u003e\n\u003cli\u003eHorizontal mounting orientation = -25 to 60°C\u003c\/li\u003e\n\u003cli\u003eVertical mounting orientation = -25 to 50°C\u003c\/li\u003e\n\u003cli\u003eDerating = -\u003c\/li\u003e\n\u003cli\u003eStorage = -40 to 85°C\u003c\/li\u003e\n\u003cli\u003eTransport = -40 to 85°C\u003c\/li\u003e\n\u003cli\u003eRelative humidity\u003c\/li\u003e\n\u003cli\u003eOperation = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003cli\u003eStorage = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003cli\u003eTransport = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSlot = In the X20 PLC\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160952131837,"sku":"X20IF1082","price":710.74,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/X20IF1082.jpg?v=1785730788"},{"product_id":"x20-x20di9371","title":"B\u0026R X20-X20DI9371 | B\u0026R","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e To Confirm\u003c\/p\u003e\n\u003cp\u003eTo Confirm.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eTo Confirm\u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Never Used Surplus","offer_id":70984802107645,"sku":"X20-X20DI9371","price":212.69,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/X20-X20DI9371.jpg?v=1785724417"},{"product_id":"x20ps9400br","title":"B\u0026R X20PS9400BR | B\u0026R","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e To Confirm\u003c\/p\u003e\n\u003cp\u003eTo Confirm.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eTo Confirm\u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Never Used Surplus","offer_id":70984802599165,"sku":"X20PS9400BR","price":331.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/X20PS9400BR.jpg?v=1785724502"},{"product_id":"x20do9322-c01","title":"B\u0026R X20DO9322-C01 | B\u0026R","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e To Confirm\u003c\/p\u003e\n\u003cp\u003eTo Confirm.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eTo Confirm\u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Never Used Surplus","offer_id":70984803451133,"sku":"X20DO9322-C01","price":203.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/X20DO9322-C01.jpg?v=1785724478"},{"product_id":"x20cs2770-c01-rev-e0","title":"B\u0026R X20CS2770-C01-REV-E0 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e To Confirm\u003c\/p\u003e\n\u003cp\u003eTo Confirm.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eTo Confirm\u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160954425597,"sku":"X20CS2770-C01-REV-E0","price":3437.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/X20CS2770-C01-REV-E0.jpg?v=1785723867"},{"product_id":"x20do8332","title":"B\u0026R X20DO8332 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e I\/O systems \u0026gt; X20 System \u0026gt; Digital outputs\u003c\/p\u003e\n\u003cp\u003e8 digital outputs with 2 A Source connection 1-wire connections Power feed integrated in the module Integrated output protection This module is equipped with 8 outputs for 1-wire connections.\u003c\/p\u003e\n\u003cp\u003eThe outputs are designed for a source circuit. The nominal output current is 2 A.\u003c\/p\u003e\n\u003cp\u003eThe output supply is fed directly to the module. An additional supply module is not needed.\u003c\/p\u003e\n\u003cp\u003eThere is no connection between the module and the I\/O supply potential on the bus module.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eShort description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eI\/O module = 8 digital outputs 24 VDC for 1-wire connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDiagnostics\u003c\/li\u003e\n\u003cli\u003eModule run\/error = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003eOutputs = Yes, using LED status indicator and software (output error status)\u003c\/li\u003e\n\u003cli\u003eSupply voltage monitoring = Yes, using software\u003c\/li\u003e\n\u003cli\u003ePower consumption\u003c\/li\u003e\n\u003cli\u003eBus = 0.22 W\u003c\/li\u003e\n\u003cli\u003eInternal I\/O = -\u003c\/li\u003e\n\u003cli\u003eExternal I\/O = 0.92 W\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = In preparation\u003c\/li\u003e\n\u003cli\u003eATEX = Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X\u003c\/li\u003e\n\u003cli\u003eUL = cULus E115267 Industrial control equipment\u003c\/li\u003e\n\u003cli\u003eHazLoc = cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5\u003c\/li\u003e\n\u003cli\u003eDNV = Temperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck)\u003c\/li\u003e\n\u003cli\u003eCCS = Yes\u003c\/li\u003e\n\u003cli\u003eLR = ENV1\u003c\/li\u003e\n\u003cli\u003eKR = Yes\u003c\/li\u003e\n\u003cli\u003eABS = Yes\u003c\/li\u003e\n\u003cli\u003eBV = EC33B Temperature: 5 - 55°C Vibration: 4 g EMC: Bridge and open deck\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0x1B9D\u003c\/li\u003e\n\u003cli\u003eStatus indicators = I\/O function per channel, operating state, module status\u003c\/li\u003e\n\u003cli\u003eAdditional power dissipation caused by actuators (resistive) [W] = +2.24\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital outputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTotal nominal current\u003c\/li\u003e\n\u003cli\u003ePer group = 4 A\u003c\/li\u003e\n\u003cli\u003ePer module = 8 A\u003c\/li\u003e\n\u003cli\u003eActuator power supply\u003c\/li\u003e\n\u003cli\u003eSupply = External\u003c\/li\u003e\n\u003cli\u003eFuse = Required line fuse: Max. 10 A, slow-blow\u003c\/li\u003e\n\u003cli\u003eSwitching delay\u003c\/li\u003e\n\u003cli\u003e0 → 1 = \u0026lt;300 µs\u003c\/li\u003e\n\u003cli\u003e1 → 0 = \u0026lt;300 µs\u003c\/li\u003e\n\u003cli\u003eSwitching frequency\u003c\/li\u003e\n\u003cli\u003eResistive load = Max. 500 Hz\u003c\/li\u003e\n\u003cli\u003eInductive load = See section \"Switching inductive loads\".\u003c\/li\u003e\n\u003cli\u003eVariant = Current-sourcing FET\u003c\/li\u003e\n\u003cli\u003eNumber of output groups = 2\u003c\/li\u003e\n\u003cli\u003eNominal voltage = 24 VDC\u003c\/li\u003e\n\u003cli\u003eSwitching voltage = 24 VDC -15% \/ +20%\u003c\/li\u003e\n\u003cli\u003eNominal output current = 2 A\u003c\/li\u003e\n\u003cli\u003eConnection type = 1-wire connections\u003c\/li\u003e\n\u003cli\u003eOutput circuit = Source\u003c\/li\u003e\n\u003cli\u003eOutput protection = Thermal shutdown in the event of overcurrent or short circuit (see value \"Short-circuit peak current\") Internal freewheeling diode for switching inductive loads (see section \"Switching inductive loads\") Reverse polarity protection of supply voltage\u003c\/li\u003e\n\u003cli\u003eDiagnostic status = Output monitoring with 10 ms delay\u003c\/li\u003e\n\u003cli\u003eLeakage current when the output is switched off = 5 µA\u003c\/li\u003e\n\u003cli\u003eR DS(on) = 140 mΩ\u003c\/li\u003e\n\u003cli\u003ePeak short-circuit current = \u0026lt;12 A\u003c\/li\u003e\n\u003cli\u003eSwitch-on in the event of overload shutdown or short-circuit shutdown = Approx. 10 ms (depends on the module temperature)\u003c\/li\u003e\n\u003cli\u003eBraking voltage when switching off inductive loads = Typ. 50 VDC\u003c\/li\u003e\n\u003cli\u003eInsulation voltage between channel and bus = 500 V eff\u003c\/li\u003e\n\u003cli\u003eAdditional functions = Outputs can be connected in parallel to increase the output current.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation = Channel isolated from bus and I\/O power supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperating conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMounting orientation\u003c\/li\u003e\n\u003cli\u003eHorizontal = Yes\u003c\/li\u003e\n\u003cli\u003eVertical = Yes\u003c\/li\u003e\n\u003cli\u003eInstallation elevation above sea level\u003c\/li\u003e\n\u003cli\u003e0 to 2000 m = No limitation\u003c\/li\u003e\n\u003cli\u003e\u0026gt;2000 m = Reduction of ambient temperature by 0.5°C per 100 m\u003c\/li\u003e\n\u003cli\u003eDegree of protection per EN 60529 = IP20\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature\u003c\/li\u003e\n\u003cli\u003eOperation\u003c\/li\u003e\n\u003cli\u003eHorizontal mounting orientation = -25 to 60°C\u003c\/li\u003e\n\u003cli\u003eVertical mounting orientation = -25 to 50°C\u003c\/li\u003e\n\u003cli\u003eDerating = See section \"Derating\".\u003c\/li\u003e\n\u003cli\u003eStorage = -40 to 85°C\u003c\/li\u003e\n\u003cli\u003eTransport = -40 to 85°C\u003c\/li\u003e\n\u003cli\u003eRelative humidity\u003c\/li\u003e\n\u003cli\u003eOperation = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003cli\u003eStorage = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003cli\u003eTransport = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNote = Order 1x terminal block X20TB12 separately. Order 1x bus module X20BM11 separately.\u003c\/li\u003e\n\u003cli\u003ePitch = 12.5 +0.2 mm\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160954949885,"sku":"X20DO8332","price":607.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/X20DO8332.jpg?v=1785724026"},{"product_id":"x20cp3485-1","title":"B\u0026R X20CP3485-1 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e PLC systems \u0026gt; X20 System \u0026gt; X20 PLC\u003c\/p\u003e\n\u003cp\u003eIntel Celeron 400 Performance with additional I\/O processor Ethernet, POWERLINK and USB onboard 3 slots for modular interface expansion CompactFlash as removable application memory Fan-free Extremely compact The X20CP3485-1 is a powerful CPU for the X20 System.\u003c\/p\u003e\n\u003cp\u003eThis CPU is especially useful for applications that require short cycle times, have to process very large amounts of data, or carry out floating point operations.\u003c\/p\u003e\n\u003cp\u003eEthernet and USB are onboard. In addition, the CPU has a POWERLINK connection for real-time communication.\u003c\/p\u003e\n\u003cp\u003eThere are also three multi-purpose slots for additional interface modules.\u003c\/p\u003e\n\u003cp\u003eThe CPU models X20CP3485 and X20CP3485-1 differ only by SDRAM size.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eShort description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInterfaces = 1x RS232, 1x Ethernet, 1x POWERLINK V1\/V2, 2x USB, 1x X2X Link\u003c\/li\u003e\n\u003cli\u003eSystem module = CPU\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDiagnostics\u003c\/li\u003e\n\u003cli\u003eBattery = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003eCPU function = Yes, using LED status indicator\u003c\/li\u003e\n\u003cli\u003eCompactFlash = Yes, using LED status indicator\u003c\/li\u003e\n\u003cli\u003eEthernet = Yes, using LED status indicator\u003c\/li\u003e\n\u003cli\u003ePOWERLINK = Yes, using LED status indicator\u003c\/li\u003e\n\u003cli\u003eOvertemperature = Yes, using LED status indicator\u003c\/li\u003e\n\u003cli\u003eSupport\u003c\/li\u003e\n\u003cli\u003eACOPOS support = Yes\u003c\/li\u003e\n\u003cli\u003eVisual Components support = Yes\u003c\/li\u003e\n\u003cli\u003eInternal power consumption of X2X Link and I\/O power supply\u003c\/li\u003e\n\u003cli\u003eBus = 1.42 W\u003c\/li\u003e\n\u003cli\u003eInternal I\/O = 0.6 W\u003c\/li\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eIF1 - IF2 = Yes\u003c\/li\u003e\n\u003cli\u003eIF1 - IF3 = Yes\u003c\/li\u003e\n\u003cli\u003eIF1 - IF4 = No\u003c\/li\u003e\n\u003cli\u003eIF1 - IF5 = No\u003c\/li\u003e\n\u003cli\u003eIF1 - IF6 = Yes\u003c\/li\u003e\n\u003cli\u003eIF2 - IF4 = Yes\u003c\/li\u003e\n\u003cli\u003eIF2 - IF5 = Yes\u003c\/li\u003e\n\u003cli\u003eIF3 - IF4 = Yes\u003c\/li\u003e\n\u003cli\u003eIF3 - IF5 = Yes\u003c\/li\u003e\n\u003cli\u003eIF4 - IF5 = No\u003c\/li\u003e\n\u003cli\u003eIF4 - IF6 = Yes\u003c\/li\u003e\n\u003cli\u003eIF5 - IF6 = Yes\u003c\/li\u003e\n\u003cli\u003ePLC - IF1 = No\u003c\/li\u003e\n\u003cli\u003ePLC - IF2 = Yes\u003c\/li\u003e\n\u003cli\u003ePLC - IF3 = Yes\u003c\/li\u003e\n\u003cli\u003ePLC - IF4 = No\u003c\/li\u003e\n\u003cli\u003ePLC - IF5 = No\u003c\/li\u003e\n\u003cli\u003ePLC - IF6 = Yes\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eATEX = Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X\u003c\/li\u003e\n\u003cli\u003eUL = cULus E115267 Industrial control equipment\u003c\/li\u003e\n\u003cli\u003eHazLoc = cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5\u003c\/li\u003e\n\u003cli\u003eDNV = Temperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck)\u003c\/li\u003e\n\u003cli\u003eCCS = Yes\u003c\/li\u003e\n\u003cli\u003eLR = ENV1\u003c\/li\u003e\n\u003cli\u003eKR = Yes\u003c\/li\u003e\n\u003cli\u003eABS = Yes\u003c\/li\u003e\n\u003cli\u003eBV = EC33B Temperature: 5 - 55°C Vibration: 4 g EMC: Bridge and open deck\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0xA2AC\u003c\/li\u003e\n\u003cli\u003eCooling = Fanless\u003c\/li\u003e\n\u003cli\u003eStatus indicators = CPU function, overtemperature, Ethernet, POWERLINK, CompactFlash, battery\u003c\/li\u003e\n\u003cli\u003eDiagnostics - Fan = -\u003c\/li\u003e\n\u003cli\u003ePower consumption without memory card, interface module and USB = 10.5 W\u003c\/li\u003e\n\u003cli\u003eAdditional power dissipation caused by actuators (resistive) [W] = -\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCPU and X2X Link power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput voltage = 24 VDC -15% \/ +20%\u003c\/li\u003e\n\u003cli\u003eInput current = Max. 2.2 A\u003c\/li\u003e\n\u003cli\u003eFuse = Integrated, cannot be replaced\u003c\/li\u003e\n\u003cli\u003eReverse polarity protection = Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eX2X Link power supply output\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNominal output power = 7 W\u003c\/li\u003e\n\u003cli\u003eParallel connection = Yes\u003c\/li\u003e\n\u003cli\u003eRedundant operation = Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInput I\/O power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput voltage = 24 VDC -15% \/ +20%\u003c\/li\u003e\n\u003cli\u003eFuse = Required line fuse: Max. 10 A, slow-blow\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOutput I\/O power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNominal output voltage = 24 VDC\u003c\/li\u003e\n\u003cli\u003ePermissible contact load = 10 A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePower supply - General information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDiagnostics\u003c\/li\u003e\n\u003cli\u003eRS232 data transfer = Yes, using LED status indicator\u003c\/li\u003e\n\u003cli\u003eModule run\/error = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003eOverload = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eI\/O supply - I\/O power supply = No\u003c\/li\u003e\n\u003cli\u003eCPU\/X2X Link supply - CPU\/X2X Link power supply = Yes\u003c\/li\u003e\n\u003cli\u003eStatus indicators = Overload, operating status, module status, RS232 data transfer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eController\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProcessor\u003c\/li\u003e\n\u003cli\u003eType = Celeron 400\u003c\/li\u003e\n\u003cli\u003eL2 cache = 256 kB\u003c\/li\u003e\n\u003cli\u003eL1 cache for data and program code = 2x 16 kB\u003c\/li\u003e\n\u003cli\u003eData buffering\u003c\/li\u003e\n\u003cli\u003eBattery monitoring = Yes\u003c\/li\u003e\n\u003cli\u003eLithium battery = At least 3 years\u003c\/li\u003e\n\u003cli\u003eStandard memory\u003c\/li\u003e\n\u003cli\u003eRAM = 64 MB SDRAM\u003c\/li\u003e\n\u003cli\u003eUser RAM = 1 MB SRAM\u003c\/li\u003e\n\u003cli\u003eCompactFlash slot = 1\u003c\/li\u003e\n\u003cli\u003eReal-time clock = Nonvolatile, resolution 1 s, -20 to 20 ppm accuracy at 25°C\u003c\/li\u003e\n\u003cli\u003eFPU = Yes\u003c\/li\u003e\n\u003cli\u003eIntegrated I\/O processor = Processes I\/O data points in the background\u003c\/li\u003e\n\u003cli\u003eModular interface slots = 3\u003c\/li\u003e\n\u003cli\u003eRemanent variables = Max. 256 kB\u003c\/li\u003e\n\u003cli\u003eShortest task class cycle time = 400 µs\u003c\/li\u003e\n\u003cli\u003eTypical instruction cycle time = 0.0055 µs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInterfaces\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInterface IF1\u003c\/li\u003e\n\u003cli\u003eType = RS232\u003c\/li\u003e\n\u003cli\u003eVariant = Connection via 12-pin terminal block TB12\u003c\/li\u003e\n\u003cli\u003eTransfer rate = Max. 115.2 kbit\/s\u003c\/li\u003e\n\u003cli\u003eInterface IF2\u003c\/li\u003e\n\u003cli\u003eType = Ethernet\u003c\/li\u003e\n\u003cli\u003eVariant = Shielded RJ45\u003c\/li\u003e\n\u003cli\u003eLine length = Max. 100 m between 2 stations (segment length)\u003c\/li\u003e\n\u003cli\u003eTransfer rate = 10\/100 Mbit\/s\u003c\/li\u003e\n\u003cli\u003eInterface IF3\u003c\/li\u003e\n\u003cli\u003eFieldbus = POWERLINK V1\/V2\u003c\/li\u003e\n\u003cli\u003eType = 100BASE-T (ANSI\/IEEE 802.3)\u003c\/li\u003e\n\u003cli\u003eTransfer rate = 100 Mbit\/s\u003c\/li\u003e\n\u003cli\u003eInterface IF4\u003c\/li\u003e\n\u003cli\u003eType = USB 1.1\u003c\/li\u003e\n\u003cli\u003eVariant = Type A\u003c\/li\u003e\n\u003cli\u003eMax. output current = 0.5 A\u003c\/li\u003e\n\u003cli\u003eInterface IF5\u003c\/li\u003e\n\u003cli\u003eInterface IF6\u003c\/li\u003e\n\u003cli\u003eType = X2X Link master\u003c\/li\u003e\n\u003cli\u003eQuantity = 1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160955506941,"sku":"X20CP3485-1","price":6720.06,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/X20CP3485-1.jpg?v=1785723781"},{"product_id":"x20br9300-2","title":"B\u0026R X20BR9300-2 | B\u0026R","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e To Confirm\u003c\/p\u003e\n\u003cp\u003eTo Confirm.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eTo Confirm\u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Never Used Surplus","offer_id":70984804499709,"sku":"X20BR9300-2","price":331.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/X20BR9300-2.jpg?v=1785724451"},{"product_id":"x20bc0143-10","title":"B\u0026R X20BC0143-10 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e I\/O systems \u0026gt; X20 System \u0026gt; Bus controllers\u003c\/p\u003e\n\u003cp\u003eFieldbus: CANopen Auto-configuration of I\/O modules I\/O configuration via the fieldbus Constant response times even with large amounts of data (max.\u003c\/p\u003e\n\u003cp\u003e32 Rx and 32 Tx PDOs) Configurable I\/O cycle (0.5 to 4 ms) Possible to configure the transfer rate or have it detected automatically Heartbeat consumer and producer Emergency producer 2x SDO server, NMT slave Simple bootup (autostart) Terminal access via the serial interface on the X20PS9400 Controller Area Network (CAN) is widespread in automation technology.\u003c\/p\u003e\n\u003cp\u003eCAN topology is based on a line structure and uses twisted wire pairs for data transfer.\u003c\/p\u003e\n\u003cp\u003eCANopen is a higher-layer protocol based on CAN. The standardized protocol offers very flexible configuration options.\u003c\/p\u003e\n\u003cp\u003eThis bus controller makes it possible to connect up to 253 X2X Link I\/O modules to CANopen.\u003c\/p\u003e\n\u003cp\u003eA transition between IP20 and IP67 protection is possible by directly connecting X20, X67 or XV modules to one another at distances of up to 100 m each across control cabinet boundaries as required.\u003c\/p\u003e\n\u003cp\u003eAll CANopen operating modes such as synchronous, event and polling are supported as well as PDO linking, life\/node guarding, heartbeat, emergency objects and much more.\u003c\/p\u003e\n\u003cp\u003eWith multifunction modules, the bus controller supports only the default function model in the event of automatic configuration by the bus controller (see the respective module description).\u003c\/p\u003e\n\u003cp\u003eAutomation Studio V4.3 or later can be used to easily create configuration files (e.g. DCF files).\u003c\/p\u003e\n\u003cp\u003eAll other function models are also supported by transferring configuration data to the bus controller (e.g.\u003c\/p\u003e\n\u003cp\u003evia the master environment with an SDO download).\u003c\/p\u003e\n\u003cp\u003eAutomation Studio can be downloaded at no cost from the B\u0026amp;R website ( www.br-automation.com ).\u003c\/p\u003e\n\u003cp\u003eThe evaluation license is permitted to be used to create complete configurations for fieldbus bus controllers at no cost.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eShort description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBus controller = CANopen slave\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDiagnostics\u003c\/li\u003e\n\u003cli\u003eModule status = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003eBus function = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003eData transfer = Yes, using LED status indicator\u003c\/li\u003e\n\u003cli\u003ePower consumption\u003c\/li\u003e\n\u003cli\u003eBus = 2 W\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = In preparation\u003c\/li\u003e\n\u003cli\u003eATEX = Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X\u003c\/li\u003e\n\u003cli\u003eUL = cULus E115267 Industrial control equipment\u003c\/li\u003e\n\u003cli\u003eHazLoc = cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5\u003c\/li\u003e\n\u003cli\u003eDNV = Temperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck)\u003c\/li\u003e\n\u003cli\u003eCCS = Yes\u003c\/li\u003e\n\u003cli\u003eLR = ENV1\u003c\/li\u003e\n\u003cli\u003eKR = Yes\u003c\/li\u003e\n\u003cli\u003eABS = Yes\u003c\/li\u003e\n\u003cli\u003eBV = EC33B Temperature: 5 - 55°C Vibration: 4 g EMC: Bridge and open deck\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0xAD3E\u003c\/li\u003e\n\u003cli\u003eStatus indicators = Module status, bus function, data transfer\u003c\/li\u003e\n\u003cli\u003eAdditional power dissipation caused by actuators (resistive) [W] = -\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInterfaces\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMin. cycle time\u003c\/li\u003e\n\u003cli\u003eFieldbus = No limitation\u003c\/li\u003e\n\u003cli\u003eX2X Link = 500 μs\u003c\/li\u003e\n\u003cli\u003eFieldbus = CANopen slave\u003c\/li\u003e\n\u003cli\u003eVariant = 9-pin male DSUB connector\u003c\/li\u003e\n\u003cli\u003eMax. distance = 1000 m\u003c\/li\u003e\n\u003cli\u003eTransfer rate = Max. 1 Mbit\/s\u003c\/li\u003e\n\u003cli\u003eDefault transfer rate = Automatic transfer rate detection or fixed setting\u003c\/li\u003e\n\u003cli\u003eSynchronization between bus systems possible = No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation = CANopen isolated from I\/O CANopen not isolated from bus\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperating conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMounting orientation\u003c\/li\u003e\n\u003cli\u003eHorizontal = Yes\u003c\/li\u003e\n\u003cli\u003eVertical = Yes\u003c\/li\u003e\n\u003cli\u003eInstallation elevation above sea level\u003c\/li\u003e\n\u003cli\u003e0 to 2000 m = No limitation\u003c\/li\u003e\n\u003cli\u003e\u0026gt;2000 m = Reduction of ambient temperature by 0.5°C per 100 m\u003c\/li\u003e\n\u003cli\u003eDegree of protection per EN 60529 = IP20\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature\u003c\/li\u003e\n\u003cli\u003eOperation\u003c\/li\u003e\n\u003cli\u003eHorizontal mounting orientation = -25 to 60°C\u003c\/li\u003e\n\u003cli\u003eVertical mounting orientation = -25 to 50°C\u003c\/li\u003e\n\u003cli\u003eDerating = -\u003c\/li\u003e\n\u003cli\u003eStorage = -40 to 85°C\u003c\/li\u003e\n\u003cli\u003eTransport = -40 to 85°C\u003c\/li\u003e\n\u003cli\u003eRelative humidity\u003c\/li\u003e\n\u003cli\u003eOperation = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003cli\u003eStorage = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003cli\u003eTransport = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNote = Order 1x terminal block X20TB12 separately. Order 1x power supply module X20PS9400 or X20PS9402 separately. Order 1x bus base X20BB80 separately.\u003c\/li\u003e\n\u003cli\u003ePitch = 37.5 +0.2 mm\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160956260605,"sku":"X20BC0143-10","price":610.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/X20BC0143-10.jpg?v=1785723563"},{"product_id":"cp1485","title":"B\u0026R CP1485 | Industrial Automation Component","description":"\u003ch2\u003eB\u0026amp;R CP1485\u003c\/h2\u003e \u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e CP1485\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eX20 CPU Controller\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eB\u0026amp;R (Bernecker + Rainer) industrial automation product. high quality, designed for high-performance machine automation.\u003c\/p\u003e \u003ch3\u003eSpecifications:\u003c\/h3\u003e \u003ctable\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eType:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003ePLC CPU Controller\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eProduct Category:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003ePLCs\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eProduct Series:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eB\u0026amp;R X20 System\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eProgramming:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eB\u0026amp;R Automation Studio, IEC 61131-3\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eCommunication Protocols:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003ePOWERLINK, EtherNet\/IP, Modbus TCP, PROFINET\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eControl Method:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eProgrammable Logic\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eNetwork Standards:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003ePOWERLINK (IEC 61158), OPC UA\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003ePower Source:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eDC 24V (via X20 PS module)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eRecommended Use:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eMachine Control, Process Automation, Motion Control\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eSuitable Space:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eControl Cabinet\u003c\/td\u003e \u003c\/tr\u003e \u003c\/table\u003e \u003ch3\u003eCompatibility:\u003c\/h3\u003e \u003cp\u003eThis product is compatible with B\u0026amp;R Automation Studio and the X20\/X67 system ecosystem. For technical documentation, use B\u0026amp;R Automation Studio integrated help.\u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160956686589,"sku":"CP1485","price":1344.06,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/CP1485.jpg?v=1785723334"},{"product_id":"x20ai46223","title":"B\u0026R X20AI46223 | B\u0026R","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e To Confirm\u003c\/p\u003e\n\u003cp\u003eTo Confirm.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eTo Confirm\u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Never Used Surplus","offer_id":70984805187837,"sku":"X20AI46223","price":706.24,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/br_brand_generic_X20AI46223.png?v=1785721181"},{"product_id":"brx20do8332","title":"B\u0026R BRX20DO8332 | B\u0026R","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e To Confirm\u003c\/p\u003e\n\u003cp\u003eTo Confirm.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eTo Confirm\u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Never Used Surplus","offer_id":70984805646589,"sku":"BRX20DO8332","price":561.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/BRX20DO8332.jpg?v=1785724400"},{"product_id":"8v1180-00-2","title":"B\u0026R 8V1180-00-2 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Motion control \u0026gt; ACOPOS \u0026gt; Servo drives\u003c\/p\u003e\n\u003cp\u003eModular mechanical design using plug-in modules Integrated line filter Integrated or optional external braking resistor All connections are made using plug-in connectors Integrated electronic restart inhibit ACOPOS servo drive, 3x 400-480 V, 19 A, 9 kW, integrated line filter, braking resistor, DC bus power supply unit and electronic safe restart interlock.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = Non-compliant\u003c\/li\u003e\n\u003cli\u003eFunctional safety = Yes\u003c\/li\u003e\n\u003cli\u003eUL = cULus E225616 Power conversion equipment\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0x1282\u003c\/li\u003e\n\u003cli\u003eSlots for plug-in modules = 4\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMains connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePermissible network configurations = TT, TN\u003c\/li\u003e\n\u003cli\u003eMains input voltage = 3x 400 VAC to 480 VAC ±10%\u003c\/li\u003e\n\u003cli\u003eFrequency = 50 \/ 60 Hz ±4%\u003c\/li\u003e\n\u003cli\u003eInstalled load = Max. 17 kVA\u003c\/li\u003e\n\u003cli\u003eInrush current at 400 VAC = 13 A\u003c\/li\u003e\n\u003cli\u003eSwitch-on interval = \u0026gt;10 s\u003c\/li\u003e\n\u003cli\u003eIntegrated line filter per EN 61800-3, category C3 = Yes\u003c\/li\u003e\n\u003cli\u003ePower dissipation at device nominal power without braking resistor = Approx. 500 W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDC bus connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDC bus capacitance = 940 µF\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCurrent consumption at 24 VDC\u003c\/li\u003e\n\u003cli\u003eMains input voltage applied = -\u003c\/li\u003e\n\u003cli\u003eMains input voltage not applied = Max. 2.8 A + Current for the motor holding brake + Current on the 24 VDC output\u003c\/li\u003e\n\u003cli\u003eDC bus power supply unit\u003c\/li\u003e\n\u003cli\u003eSwitch-on voltage = 455 VDC\u003c\/li\u003e\n\u003cli\u003eInput voltage = 24 VDC +25% \/ -20%\u003c\/li\u003e\n\u003cli\u003eInput capacitance = 40,000 µF\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC output\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput voltage\u003c\/li\u003e\n\u003cli\u003eMains input voltage applied = 22 to 24 VDC\u003c\/li\u003e\n\u003cli\u003eMains input voltage not applied = 16.7 to 30 VDC\u003c\/li\u003e\n\u003cli\u003eOutput current = Max. 0.5 A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMotor connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReduction of continuous current depending on ambient temperature\u003c\/li\u003e\n\u003cli\u003eMains input voltage: 400 VAC\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz = No reduction\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz = No reduction\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 20 kHz = No reduction\u003c\/li\u003e\n\u003cli\u003eMains input voltage: 480 VAC\u003c\/li\u003e\n\u003cli\u003eReduction of continuous current depending on installation elevation\u003c\/li\u003e\n\u003cli\u003eStarting at 500 m above sea level = 1.9 A eff per 1000 m\u003c\/li\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eOverload protection = Yes\u003c\/li\u003e\n\u003cli\u003eShort-circuit and ground fault protection = Yes\u003c\/li\u003e\n\u003cli\u003eTerminal connection cross section\u003c\/li\u003e\n\u003cli\u003eFlexible and fine-stranded wires\u003c\/li\u003e\n\u003cli\u003eWith wire end sleeve = 0.5 to 6 mm²\u003c\/li\u003e\n\u003cli\u003eApprobation data\u003c\/li\u003e\n\u003cli\u003eUL\/C-UL-US = 20 to 8 AWG\u003c\/li\u003e\n\u003cli\u003eCSA = 20 to 8 AWG\u003c\/li\u003e\n\u003cli\u003eQuantity = 1\u003c\/li\u003e\n\u003cli\u003eContinuous current = 19 A eff\u003c\/li\u003e\n\u003cli\u003ePeak current = 50 A eff\u003c\/li\u003e\n\u003cli\u003eNominal switching frequency = 10 kHz\u003c\/li\u003e\n\u003cli\u003ePossible switching frequencies = 5 \/ 10 \/ 20 kHz\u003c\/li\u003e\n\u003cli\u003eInsulation stress of the connected motor per IEC TS 60034-25:2004 = Limit value curve A\u003c\/li\u003e\n\u003cli\u003eMax. motor line length = 25 m\u003c\/li\u003e\n\u003cli\u003eMax. output frequency = 598 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMotor holding brake connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eResponse threshold for open-circuit monitoring = Approx. 250 mA\u003c\/li\u003e\n\u003cli\u003eMax. output current = 1.5 A\u003c\/li\u003e\n\u003cli\u003eMax. number of switching cycles = Unlimited since implemented electronically\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBraking resistor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePeak power int.\/ext. = 14 \/ 40 kW\u003c\/li\u003e\n\u003cli\u003eContinuous power int.\/ext. = 0.4 \/ 8 kW\u003c\/li\u003e\n\u003cli\u003eMinimum braking resistance (ext.) = 15 Ω\u003c\/li\u003e\n\u003cli\u003eRated current of built-in fuse = 12 A (fast-acting)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLimit switch and reference inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eInput - ACOPOS = Yes\u003c\/li\u003e\n\u003cli\u003eInput - Input = No\u003c\/li\u003e\n\u003cli\u003eInput voltage\u003c\/li\u003e\n\u003cli\u003eNominal = 24 VDC\u003c\/li\u003e\n\u003cli\u003eMaximum = 30 VDC\u003c\/li\u003e\n\u003cli\u003eSwitching threshold\u003c\/li\u003e\n\u003cli\u003eLow = \u0026lt;5 V\u003c\/li\u003e\n\u003cli\u003eHigh = \u0026gt;15 V\u003c\/li\u003e\n\u003cli\u003eQuantity = 3\u003c\/li\u003e\n\u003cli\u003eCircuit = Sink\u003c\/li\u003e\n\u003cli\u003eInput current at nominal voltage = Approx. 4 mA\u003c\/li\u003e\n\u003cli\u003eSwitching delay = Max. 2.0 ms\u003c\/li\u003e\n\u003cli\u003eModulation compared to ground potential = Max. ±38 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnable inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eInput - ACOPOS = Yes\u003c\/li\u003e\n\u003cli\u003eInput voltage\u003c\/li\u003e\n\u003cli\u003eNominal = 24 VDC\u003c\/li\u003e\n\u003cli\u003eMaximum = 30 VDC\u003c\/li\u003e\n\u003cli\u003eSwitching threshold\u003c\/li\u003e\n\u003cli\u003eLow = \u0026lt;5 V\u003c\/li\u003e\n\u003cli\u003eHigh = \u0026gt;15 V\u003c\/li\u003e\n\u003cli\u003eSwitching delay\u003c\/li\u003e\n\u003cli\u003eEnable 0 → 1, ready for PWM = Max. 100 µs\u003c\/li\u003e\n\u003cli\u003eEnable 1 → 0, PWM off = Max. 2.0 ms\u003c\/li\u003e\n\u003cli\u003eQuantity = 1\u003c\/li\u003e\n\u003cli\u003eCircuit = Sink\u003c\/li\u003e\n\u003cli\u003eInput current at nominal voltage = Approx. 30 mA\u003c\/li\u003e\n\u003cli\u003eModulation compared to ground potential = Max. ±38 V\u003c\/li\u003e\n\u003cli\u003eOSSD signal connections = Not permitted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrigger inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eInput - ACOPOS = Yes\u003c\/li\u003e\n\u003cli\u003eInput - Input = No\u003c\/li\u003e\n\u003cli\u003eInput voltage\u003c\/li\u003e\n\u003cli\u003eNominal = 24 VDC\u003c\/li\u003e\n\u003cli\u003eMaximum = 30 VDC\u003c\/li\u003e\n\u003cli\u003eSwitching threshold\u003c\/li\u003e\n\u003cli\u003eLow = \u0026lt;5 V\u003c\/li\u003e\n\u003cli\u003eHigh = \u0026gt;15 V\u003c\/li\u003e\n\u003cli\u003eSwitching delay\u003c\/li\u003e\n\u003cli\u003eRising edge = 52 µs ±0.5 µs (digitally filtered)\u003c\/li\u003e\n\u003cli\u003eFalling edge = 53 µs ±0.5 µs (digitally filtered)\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eCircuit = Sink\u003c\/li\u003e\n\u003cli\u003eInput current at nominal voltage = Approx. 10 mA\u003c\/li\u003e\n\u003cli\u003eModulation compared to ground potential = Max. ±38 V\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160957538557,"sku":"8V1180-00-2","price":9896.58,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/8V1180-00-2.jpg?v=1785723325"},{"product_id":"brx20ps9400","title":"B\u0026R BRX20PS9400 | B\u0026R","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e To Confirm\u003c\/p\u003e\n\u003cp\u003eTo Confirm.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eTo Confirm\u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Never Used Surplus","offer_id":70984806367485,"sku":"BRX20PS9400","price":240.22,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/BRX20PS9400.jpg?v=1785724408"},{"product_id":"8v1022-002","title":"B\u0026R 8V1022-002 | B\u0026R","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Motion control \u0026gt; ACOPOS \u0026gt; Servo drives\u003c\/p\u003e\n\u003cp\u003eModular mechanical design using plug-in modules Integrated line filter Integrated braking resistor All connections are made using plug-in connectors Integrated electronic restart inhibit ACOPOS servo drive, 3x 400-480 V, 2.2 A, 1 kW, integrated line filter, braking resistor and electronic safe restart interlock.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = Non-compliant\u003c\/li\u003e\n\u003cli\u003eFunctional safety = Yes\u003c\/li\u003e\n\u003cli\u003eUL = cULus E225616 Power conversion equipment\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0x1284\u003c\/li\u003e\n\u003cli\u003eSlots for plug-in modules = 4\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMains connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePermissible network configurations = TT, TN\u003c\/li\u003e\n\u003cli\u003eMains input voltage = 3x 400 VAC to 480 VAC ±10% 3x 230 VAC ±10%\u003c\/li\u003e\n\u003cli\u003eFrequency = 50 \/ 60 Hz ±4%\u003c\/li\u003e\n\u003cli\u003eInstalled load = Max. 3 kVA\u003c\/li\u003e\n\u003cli\u003eInrush current at 400 VAC = 4 A\u003c\/li\u003e\n\u003cli\u003eSwitch-on interval = \u0026gt;10 s\u003c\/li\u003e\n\u003cli\u003eIntegrated line filter per EN 61800-3, category C3 = Yes\u003c\/li\u003e\n\u003cli\u003ePower dissipation at device nominal power without braking resistor = Approx. 120 W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDC bus connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDC bus capacitance = 235 µF\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput voltage = 24 VDC ±25%\u003c\/li\u003e\n\u003cli\u003eInput capacitance = 8200 µF\u003c\/li\u003e\n\u003cli\u003eCurrent consumption = Max. 2.5 A + Current for motor holding brake\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMotor connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReduction of continuous current depending on ambient temperature\u003c\/li\u003e\n\u003cli\u003eMains input voltage: 400 VAC\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz = No reduction\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz = No reduction\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 20 kHz = No reduction\u003c\/li\u003e\n\u003cli\u003eMains input voltage: 480 VAC\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 20 kHz = 0.13 A eff per °C (starting at 51°C)\u003c\/li\u003e\n\u003cli\u003eReduction of continuous current depending on installation elevation\u003c\/li\u003e\n\u003cli\u003eStarting at 500 m above sea level = 0.22 A eff per 1000 m\u003c\/li\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eOverload protection = Yes\u003c\/li\u003e\n\u003cli\u003eShort-circuit and ground fault protection = Yes\u003c\/li\u003e\n\u003cli\u003eTerminal connection cross section\u003c\/li\u003e\n\u003cli\u003eFlexible and fine-stranded wires\u003c\/li\u003e\n\u003cli\u003eWith wire end sleeve = 0.25 to 4 mm²\u003c\/li\u003e\n\u003cli\u003eApprobation data\u003c\/li\u003e\n\u003cli\u003eUL\/C-UL-US = 30 to 10 AWG\u003c\/li\u003e\n\u003cli\u003eCSA = 28 to 10 AWG\u003c\/li\u003e\n\u003cli\u003eQuantity = 1\u003c\/li\u003e\n\u003cli\u003eContinuous current = 2.2 A eff\u003c\/li\u003e\n\u003cli\u003ePeak current = 14 A eff\u003c\/li\u003e\n\u003cli\u003eNominal switching frequency = 20 kHz\u003c\/li\u003e\n\u003cli\u003ePossible switching frequencies = 5 \/ 10 \/ 20 kHz\u003c\/li\u003e\n\u003cli\u003eInsulation stress of the connected motor per IEC TS 60034-25:2004 = Limit value curve A\u003c\/li\u003e\n\u003cli\u003eMax. motor line length = 25 m\u003c\/li\u003e\n\u003cli\u003eMax. output frequency = 598 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMotor holding brake connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eResponse threshold for open-circuit monitoring = Approx. 385 mA\u003c\/li\u003e\n\u003cli\u003eMax. output current = 1 A\u003c\/li\u003e\n\u003cli\u003eMax. number of switching cycles = Unlimited since implemented electronically\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBraking resistor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePeak power output = 3.5 kW\u003c\/li\u003e\n\u003cli\u003eContinuous power = 130 W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLimit switch and reference inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eInput - ACOPOS = Yes\u003c\/li\u003e\n\u003cli\u003eInput - Input = No\u003c\/li\u003e\n\u003cli\u003eInput voltage\u003c\/li\u003e\n\u003cli\u003eNominal = 24 VDC\u003c\/li\u003e\n\u003cli\u003eMaximum = 30 VDC\u003c\/li\u003e\n\u003cli\u003eSwitching threshold\u003c\/li\u003e\n\u003cli\u003eLow = \u0026lt;5 V\u003c\/li\u003e\n\u003cli\u003eHigh = \u0026gt;15 V\u003c\/li\u003e\n\u003cli\u003eQuantity = 3\u003c\/li\u003e\n\u003cli\u003eCircuit = Sink\u003c\/li\u003e\n\u003cli\u003eInput current at nominal voltage = Approx. 4 mA\u003c\/li\u003e\n\u003cli\u003eSwitching delay = Max. 2.0 ms\u003c\/li\u003e\n\u003cli\u003eModulation compared to ground potential = Max. ±38 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnable inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eInput - ACOPOS = Yes\u003c\/li\u003e\n\u003cli\u003eInput voltage\u003c\/li\u003e\n\u003cli\u003eNominal = 24 VDC\u003c\/li\u003e\n\u003cli\u003eMaximum = 30 VDC\u003c\/li\u003e\n\u003cli\u003eSwitching threshold\u003c\/li\u003e\n\u003cli\u003eLow = \u0026lt;5 V\u003c\/li\u003e\n\u003cli\u003eHigh = \u0026gt;15 V\u003c\/li\u003e\n\u003cli\u003eSwitching delay\u003c\/li\u003e\n\u003cli\u003eEnable 0 → 1, ready for PWM = Max. 100 µs\u003c\/li\u003e\n\u003cli\u003eEnable 1 → 0, PWM off = Max. 2.0 ms\u003c\/li\u003e\n\u003cli\u003eQuantity = 1\u003c\/li\u003e\n\u003cli\u003eCircuit = Sink\u003c\/li\u003e\n\u003cli\u003eInput current at nominal voltage = Approx. 30 mA\u003c\/li\u003e\n\u003cli\u003eModulation compared to ground potential = Max. ±38 V\u003c\/li\u003e\n\u003cli\u003eOSSD signal connections = Not permitted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrigger inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eInput - ACOPOS = Yes\u003c\/li\u003e\n\u003cli\u003eInput - Input = No\u003c\/li\u003e\n\u003cli\u003eInput voltage\u003c\/li\u003e\n\u003cli\u003eNominal = 24 VDC\u003c\/li\u003e\n\u003cli\u003eMaximum = 30 VDC\u003c\/li\u003e\n\u003cli\u003eSwitching threshold\u003c\/li\u003e\n\u003cli\u003eLow = \u0026lt;5 V\u003c\/li\u003e\n\u003cli\u003eHigh = \u0026gt;15 V\u003c\/li\u003e\n\u003cli\u003eSwitching delay\u003c\/li\u003e\n\u003cli\u003eRising edge = 52 µs ±0.5 µs (digitally filtered)\u003c\/li\u003e\n\u003cli\u003eFalling edge = 53 µs ±0.5 µs (digitally filtered)\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eCircuit = Sink\u003c\/li\u003e\n\u003cli\u003eInput current at nominal voltage = Approx. 10 mA\u003c\/li\u003e\n\u003cli\u003eModulation compared to ground potential = Max. ±38 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEnergy efficiency (IE classification)\u003c\/li\u003e\n\u003cli\u003ePower dissipation relative to continuous apparent power = IE2 (10,25) 3.8% IE2 (50,25) 3.8% IE2 (10,50) 4% IE2 (50,50) 4% IE2 (90,50) 4.1% IE2 (10,100) 4.3% IE2 (50,100) 4.4% IE2 (90,100) 4.7%\u003c\/li\u003e\n\u003cli\u003eNominal losses in standby mode = 13.2 W\u003c\/li\u003e\n\u003cli\u003eDischarge capacitance = 660 nF\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"Never Used Surplus","offer_id":70984806957309,"sku":"8V1022-002","price":6310.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/8V1022-002.jpg?v=1785722943"},{"product_id":"8v1016-001-2","title":"B\u0026R 8V1016-001-2 | B\u0026R","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Motion control \u0026gt; ACOPOS \u0026gt; Servo drives\u003c\/p\u003e\n\u003cp\u003eModular mechanical design using plug-in modules Integrated line filter Integrated braking resistor Integrated electronic restart inhibit Partially-coated circuit boards - more robust in regard to environmental influences ACOPOS servo drive, 3x 400-480 V, 1.6 A, 0.7 kW, coated, integrated line filter, braking resistor and electronic safe restart interlock.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = Non-compliant\u003c\/li\u003e\n\u003cli\u003eFunctional safety = Yes\u003c\/li\u003e\n\u003cli\u003eUL = cULus E225616 Power conversion equipment\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eNote = Variant with partially coated printed circuit boards\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0xA6D6\u003c\/li\u003e\n\u003cli\u003eSlots for plug-in modules = 3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMains connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePermissible network configurations = TT, TN\u003c\/li\u003e\n\u003cli\u003eMains input voltage = 3x 400 VAC to 480 VAC ±10% 3x 230 VAC ±10%\u003c\/li\u003e\n\u003cli\u003eFrequency = 50 \/ 60 Hz ±4%\u003c\/li\u003e\n\u003cli\u003eInstalled load = Max. 2.1 kVA\u003c\/li\u003e\n\u003cli\u003eInrush current = 2 A (at 400 VAC)\u003c\/li\u003e\n\u003cli\u003eSwitch-on interval = \u0026gt;10 s\u003c\/li\u003e\n\u003cli\u003eIntegrated line filter per EN 61800-3, category C3 = Yes\u003c\/li\u003e\n\u003cli\u003ePower dissipation at device nominal power without braking resistor = 110 W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDC bus connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDC bus capacitance = 165 µF\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput voltage = 24 VDC +25% \/ -20%\u003c\/li\u003e\n\u003cli\u003eInput capacitance = 5600 µF\u003c\/li\u003e\n\u003cli\u003eCurrent consumption = Max. 1.47 A + Current for motor holding brake\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMotor connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReduction of continuous current depending on ambient temperature\u003c\/li\u003e\n\u003cli\u003eMains input voltage: 400 VAC\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz = No reduction\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz = No reduction\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 20 kHz = No reduction\u003c\/li\u003e\n\u003cli\u003eMains input voltage: 480 VAC\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 20 kHz = 0.13 A eff per °C (starting at 40°C)\u003c\/li\u003e\n\u003cli\u003eReduction of continuous current depending on installation elevation\u003c\/li\u003e\n\u003cli\u003eStarting at 500 m above sea level = 0.16 A eff per 1000 m\u003c\/li\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eOverload protection = Yes\u003c\/li\u003e\n\u003cli\u003eShort-circuit and ground fault protection = Yes\u003c\/li\u003e\n\u003cli\u003eTerminal connection cross section\u003c\/li\u003e\n\u003cli\u003eFlexible and fine-stranded wires\u003c\/li\u003e\n\u003cli\u003eWith wire end sleeve = 0.25 to 4 mm²\u003c\/li\u003e\n\u003cli\u003eApprobation data\u003c\/li\u003e\n\u003cli\u003eUL\/C-UL-US = 30 to 10 AWG\u003c\/li\u003e\n\u003cli\u003eCSA = 28 to 10 AWG\u003c\/li\u003e\n\u003cli\u003eQuantity = 1\u003c\/li\u003e\n\u003cli\u003eContinuous current = 1.6 A eff\u003c\/li\u003e\n\u003cli\u003ePeak current = 5 A eff\u003c\/li\u003e\n\u003cli\u003eNominal switching frequency = 10 kHz\u003c\/li\u003e\n\u003cli\u003ePossible switching frequencies = 5 \/ 10 \/ 20 kHz\u003c\/li\u003e\n\u003cli\u003eInsulation stress of the connected motor per IEC TS 60034-25:2004 = Limit value curve A\u003c\/li\u003e\n\u003cli\u003eMax. motor line length = 15 m\u003c\/li\u003e\n\u003cli\u003eMax. output frequency = 598 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMotor holding brake connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eResponse threshold for open-circuit monitoring = Approx. 245 mA\u003c\/li\u003e\n\u003cli\u003eMax. output current = 1.3 A\u003c\/li\u003e\n\u003cli\u003eMax. number of switching cycles = Unlimited since implemented electronically\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBraking resistor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePeak power output = 2 kW\u003c\/li\u003e\n\u003cli\u003eContinuous power = 130 W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLimit switch and reference inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eInput - ACOPOS = Yes\u003c\/li\u003e\n\u003cli\u003eInput - Input = No\u003c\/li\u003e\n\u003cli\u003eInput voltage\u003c\/li\u003e\n\u003cli\u003eNominal = 24 VDC\u003c\/li\u003e\n\u003cli\u003eMaximum = 30 VDC\u003c\/li\u003e\n\u003cli\u003eSwitching threshold\u003c\/li\u003e\n\u003cli\u003eLow = \u0026lt;5 V\u003c\/li\u003e\n\u003cli\u003eHigh = \u0026gt;15 V\u003c\/li\u003e\n\u003cli\u003eQuantity = 3\u003c\/li\u003e\n\u003cli\u003eCircuit = Sink\u003c\/li\u003e\n\u003cli\u003eInput current at nominal voltage = Approx. 4 mA\u003c\/li\u003e\n\u003cli\u003eSwitching delay = Max. 2.0 ms\u003c\/li\u003e\n\u003cli\u003eModulation compared to ground potential = Max. ±38 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnable inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eInput - ACOPOS = Yes\u003c\/li\u003e\n\u003cli\u003eInput voltage\u003c\/li\u003e\n\u003cli\u003eNominal = 24 VDC\u003c\/li\u003e\n\u003cli\u003eMaximum = 30 VDC\u003c\/li\u003e\n\u003cli\u003eSwitching threshold\u003c\/li\u003e\n\u003cli\u003eLow = \u0026lt;5 V\u003c\/li\u003e\n\u003cli\u003eHigh = \u0026gt;15 V\u003c\/li\u003e\n\u003cli\u003eSwitching delay\u003c\/li\u003e\n\u003cli\u003eEnable 0 → 1, ready for PWM = Max. 100 µs\u003c\/li\u003e\n\u003cli\u003eEnable 1 → 0, PWM off = Max. 2.0 ms\u003c\/li\u003e\n\u003cli\u003eQuantity = 1\u003c\/li\u003e\n\u003cli\u003eCircuit = Sink\u003c\/li\u003e\n\u003cli\u003eInput current at nominal voltage = Approx. 30 mA\u003c\/li\u003e\n\u003cli\u003eModulation compared to ground potential = Max. ±38 V\u003c\/li\u003e\n\u003cli\u003eOSSD signal connections = Not permitted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrigger inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eInput - ACOPOS = Yes\u003c\/li\u003e\n\u003cli\u003eInput - Input = No\u003c\/li\u003e\n\u003cli\u003eInput voltage\u003c\/li\u003e\n\u003cli\u003eNominal = 24 VDC\u003c\/li\u003e\n\u003cli\u003eMaximum = 30 VDC\u003c\/li\u003e\n\u003cli\u003eSwitching threshold\u003c\/li\u003e\n\u003cli\u003eLow = \u0026lt;5 V\u003c\/li\u003e\n\u003cli\u003eHigh = \u0026gt;15 V\u003c\/li\u003e\n\u003cli\u003eSwitching delay\u003c\/li\u003e\n\u003cli\u003eRising edge = 52 µs ±0.5 µs (digitally filtered)\u003c\/li\u003e\n\u003cli\u003eFalling edge = 53 µs ±0.5 µs (digitally filtered)\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eCircuit = Sink\u003c\/li\u003e\n\u003cli\u003eInput current at nominal voltage = Approx. 10 mA\u003c\/li\u003e\n\u003cli\u003eModulation compared to ground potential = Max. ±38 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEnergy efficiency (IE classification)\u003c\/li\u003e\n\u003cli\u003ePower dissipation relative to continuous apparent power = IE2 (10,25) 4.6% IE2 (50,25) 4.6% IE2 (10,50) 4.6% IE2 (50,50) 4.6% IE2 (90,50) 4.7% IE2 (10,100) 4.8% IE2 (50,100) 5% IE2 (90,100) 5.2%\u003c\/li\u003e\n\u003cli\u003eNominal losses in standby mode = 12.5 W\u003c\/li\u003e\n\u003cli\u003eDischarge capacitance = 550 nF\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"Never Used Surplus","offer_id":70984807874813,"sku":"8V1016-001-2","price":5616.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/8V1016-001-2.jpg?v=1785722936"},{"product_id":"8v1045-00-2","title":"B\u0026R 8V1045-00-2 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Motion control \u0026gt; ACOPOS \u0026gt; Servo drives\u003c\/p\u003e\n\u003cp\u003eModular mechanical design using plug-in modules Integrated line filter Integrated braking resistor All connections are made using plug-in connectors Integrated electronic restart inhibit ACOPOS servo drive, 3x 400-480 V, 4.4 A, 2 kW, integrated line filter, braking resistor and electronic safe restart interlock.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = Non-compliant\u003c\/li\u003e\n\u003cli\u003eFunctional safety = Yes\u003c\/li\u003e\n\u003cli\u003eUL = cULus E225616 Power conversion equipment\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0x12C7\u003c\/li\u003e\n\u003cli\u003eSlots for plug-in modules = 4\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMains connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePermissible network configurations = TT, TN\u003c\/li\u003e\n\u003cli\u003eMains input voltage = 3x 400 VAC to 480 VAC ±10% 3x 230 VAC ±10%\u003c\/li\u003e\n\u003cli\u003eFrequency = 50 \/ 60 Hz ±4%\u003c\/li\u003e\n\u003cli\u003eInstalled load = Max. 5 kVA\u003c\/li\u003e\n\u003cli\u003eInrush current at 400 VAC = 7 A\u003c\/li\u003e\n\u003cli\u003eSwitch-on interval = \u0026gt;10 s\u003c\/li\u003e\n\u003cli\u003eIntegrated line filter per EN 61800-3, category C3 = Yes\u003c\/li\u003e\n\u003cli\u003ePower dissipation at device nominal power without braking resistor = Approx. 180 W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDC bus connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDC bus capacitance = 235 µF\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput voltage = 24 VDC ±25%\u003c\/li\u003e\n\u003cli\u003eInput capacitance = 8200 µF\u003c\/li\u003e\n\u003cli\u003eCurrent consumption = Max. 2.5 A + Current for motor holding brake\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMotor connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReduction of continuous current depending on ambient temperature\u003c\/li\u003e\n\u003cli\u003eMains input voltage: 400 VAC\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz = No reduction\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz = No reduction\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 20 kHz = 0.13 A eff per °C (starting at 45°C)\u003c\/li\u003e\n\u003cli\u003eMains input voltage: 480 VAC\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 20 kHz = 0.13 A eff per °C (starting at 35°C)\u003c\/li\u003e\n\u003cli\u003eReduction of continuous current depending on installation elevation\u003c\/li\u003e\n\u003cli\u003eStarting at 500 m above sea level = 0.44 A eff per 1000 m\u003c\/li\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eOverload protection = Yes\u003c\/li\u003e\n\u003cli\u003eShort-circuit and ground fault protection = Yes\u003c\/li\u003e\n\u003cli\u003eTerminal connection cross section\u003c\/li\u003e\n\u003cli\u003eFlexible and fine-stranded wires\u003c\/li\u003e\n\u003cli\u003eWith wire end sleeve = 0.25 to 4 mm²\u003c\/li\u003e\n\u003cli\u003eApprobation data\u003c\/li\u003e\n\u003cli\u003eUL\/C-UL-US = 30 to 10 AWG\u003c\/li\u003e\n\u003cli\u003eCSA = 28 to 10 AWG\u003c\/li\u003e\n\u003cli\u003eQuantity = 1\u003c\/li\u003e\n\u003cli\u003eContinuous current = 4.4 A eff\u003c\/li\u003e\n\u003cli\u003ePeak current = 24 A eff\u003c\/li\u003e\n\u003cli\u003eNominal switching frequency = 20 kHz\u003c\/li\u003e\n\u003cli\u003ePossible switching frequencies = 5 \/ 10 \/ 20 kHz\u003c\/li\u003e\n\u003cli\u003eInsulation stress of the connected motor per IEC TS 60034-25:2004 = Limit value curve A\u003c\/li\u003e\n\u003cli\u003eMax. motor line length = 25 m\u003c\/li\u003e\n\u003cli\u003eMax. output frequency = 598 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMotor holding brake connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eResponse threshold for open-circuit monitoring = Approx. 385 mA\u003c\/li\u003e\n\u003cli\u003eMax. output current = 1 A\u003c\/li\u003e\n\u003cli\u003eMax. number of switching cycles = Unlimited since implemented electronically\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBraking resistor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePeak power output = 7 kW\u003c\/li\u003e\n\u003cli\u003eContinuous power = 200 W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLimit switch and reference inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eInput - ACOPOS = Yes\u003c\/li\u003e\n\u003cli\u003eInput - Input = No\u003c\/li\u003e\n\u003cli\u003eInput voltage\u003c\/li\u003e\n\u003cli\u003eNominal = 24 VDC\u003c\/li\u003e\n\u003cli\u003eMaximum = 30 VDC\u003c\/li\u003e\n\u003cli\u003eSwitching threshold\u003c\/li\u003e\n\u003cli\u003eLow = \u0026lt;5 V\u003c\/li\u003e\n\u003cli\u003eHigh = \u0026gt;15 V\u003c\/li\u003e\n\u003cli\u003eQuantity = 3\u003c\/li\u003e\n\u003cli\u003eCircuit = Sink\u003c\/li\u003e\n\u003cli\u003eInput current at nominal voltage = Approx. 4 mA\u003c\/li\u003e\n\u003cli\u003eSwitching delay = Max. 2.0 ms\u003c\/li\u003e\n\u003cli\u003eModulation compared to ground potential = Max. ±38 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnable inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eInput - ACOPOS = Yes\u003c\/li\u003e\n\u003cli\u003eInput voltage\u003c\/li\u003e\n\u003cli\u003eNominal = 24 VDC\u003c\/li\u003e\n\u003cli\u003eMaximum = 30 VDC\u003c\/li\u003e\n\u003cli\u003eSwitching threshold\u003c\/li\u003e\n\u003cli\u003eLow = \u0026lt;5 V\u003c\/li\u003e\n\u003cli\u003eHigh = \u0026gt;15 V\u003c\/li\u003e\n\u003cli\u003eSwitching delay\u003c\/li\u003e\n\u003cli\u003eEnable 0 → 1, ready for PWM = Max. 100 µs\u003c\/li\u003e\n\u003cli\u003eEnable 1 → 0, PWM off = Max. 2.0 ms\u003c\/li\u003e\n\u003cli\u003eQuantity = 1\u003c\/li\u003e\n\u003cli\u003eCircuit = Sink\u003c\/li\u003e\n\u003cli\u003eInput current at nominal voltage = Approx. 30 mA\u003c\/li\u003e\n\u003cli\u003eModulation compared to ground potential = Max. ±38 V\u003c\/li\u003e\n\u003cli\u003eOSSD signal connections = Not permitted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrigger inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eInput - ACOPOS = Yes\u003c\/li\u003e\n\u003cli\u003eInput - Input = No\u003c\/li\u003e\n\u003cli\u003eInput voltage\u003c\/li\u003e\n\u003cli\u003eNominal = 24 VDC\u003c\/li\u003e\n\u003cli\u003eMaximum = 30 VDC\u003c\/li\u003e\n\u003cli\u003eSwitching threshold\u003c\/li\u003e\n\u003cli\u003eLow = \u0026lt;5 V\u003c\/li\u003e\n\u003cli\u003eHigh = \u0026gt;15 V\u003c\/li\u003e\n\u003cli\u003eSwitching delay\u003c\/li\u003e\n\u003cli\u003eRising edge = 52 µs ±0.5 µs (digitally filtered)\u003c\/li\u003e\n\u003cli\u003eFalling edge = 53 µs ±0.5 µs (digitally filtered)\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eCircuit = Sink\u003c\/li\u003e\n\u003cli\u003eInput current at nominal voltage = Approx. 10 mA\u003c\/li\u003e\n\u003cli\u003eModulation compared to ground potential = Max. ±38 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEnergy efficiency (IE classification)\u003c\/li\u003e\n\u003cli\u003ePower dissipation relative to continuous apparent power = IE2 (10,25) 2.2% IE2 (50,25) 2.2% IE2 (10,50) 2.4% IE2 (50,50) 2.4% IE2 (90,50) 2.6% IE2 (10,100) 2.7% IE2 (50,100) 2.9% IE2 (90,100) 3.3%\u003c\/li\u003e\n\u003cli\u003eNominal losses in standby mode = 13.2 W\u003c\/li\u003e\n\u003cli\u003eDischarge capacitance = 660 nF\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160958849277,"sku":"8V1045-00-2","price":6749.46,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/8V1045-00-2.jpg?v=1785723317"},{"product_id":"8lsa35-ea030d000-3","title":"B\u0026R 8LSA35-EA030D000-3 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e To Confirm\u003c\/p\u003e\n\u003cp\u003eSynchronous motor 8LS, self-cooling, construction type A, 400 VAC - Number of pole pairs: 4 - Nominal speed: 3000 rpm - Nominal torque: 2.100 Nm - Stall torque: 2.300 Nm - Centering diameter: 80.00 mm, j6 fit - Flange square dimension: 91.30 mm - Brake holding torque: 0.00 Nm - Smooth shaft d=14.00 k6x30.00 mm, without oil seal - ECI 1319 ENDAT01, S: 1 - 00: No special option - Efficiency: 91.0.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = In preparation\u003c\/li\u003e\n\u003cli\u003eUL = cURus E360421 Servo and stepper motors - Component\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMotor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNominal speed n N [rpm] = 3000\u003c\/li\u003e\n\u003cli\u003eNumber of pole pairs = 4\u003c\/li\u003e\n\u003cli\u003eNominal torque M n [Nm] = 2.1\u003c\/li\u003e\n\u003cli\u003eNominal power P N [W] = 660\u003c\/li\u003e\n\u003cli\u003eNominal current I N [A] = 1.4\u003c\/li\u003e\n\u003cli\u003eStall torque M 0 [Nm] = 2.3\u003c\/li\u003e\n\u003cli\u003eStall current I 0 [A] = 1.6\u003c\/li\u003e\n\u003cli\u003eMaximum torque M max [Nm] = 9.2\u003c\/li\u003e\n\u003cli\u003eMaximum current I max [A] = 6.8\u003c\/li\u003e\n\u003cli\u003eMaximum speed n max [rpm] = 9000\u003c\/li\u003e\n\u003cli\u003eTorque constant K T [Nm\/A] = 1.45\u003c\/li\u003e\n\u003cli\u003eVoltage constant K E [V\/1000 rpm] = 87.96\u003c\/li\u003e\n\u003cli\u003eStator resistance R 2ph [Ω] = 12.22\u003c\/li\u003e\n\u003cli\u003eStator inductance L 2ph [mH] = 63\u003c\/li\u003e\n\u003cli\u003eElectrical time constant t el [ms] = 5.2\u003c\/li\u003e\n\u003cli\u003eThermal time constant t therm [min] = 34\u003c\/li\u003e\n\u003cli\u003eMoment of inertia J [kgcm 2 ] = 0.9\u003c\/li\u003e\n\u003cli\u003eWeight without brake m [kg] = 4.4\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eHolding brake\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHolding torque of brake M Br [Nm] = 0\u003c\/li\u003e\n\u003cli\u003eMass of brake [kg] = 1.09\u003c\/li\u003e\n\u003cli\u003eMoment of inertia of brake J Br [kgcm 2 ] = 0.38\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRecommendations\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eACOPOS 8Vxxxx.xx... = 1022\u003c\/li\u003e\n\u003cli\u003eACOPOSmulti 8BVIxxxx... = 0014\u003c\/li\u003e\n\u003cli\u003eACOPOS P3 8EIxxxx... = 2X2X\u003c\/li\u003e\n\u003cli\u003eCross section for B\u0026amp;R motor cables [mm 2 ] = 0.75\u003c\/li\u003e\n\u003cli\u003eConnector size = 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConnection type = Connector (ytec system)\u003c\/li\u003e\n\u003cli\u003eConnection direction = Angled (swivel)\u003c\/li\u003e\n\u003cli\u003eEncoder = EA inductive 32-line single-turn V2\u003c\/li\u003e\n\u003cli\u003eShaft end = Smooth shaft\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160959308029,"sku":"8LSA35-EA030D000-3","price":6083.34,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/8LSA35-EA030D000-3_brand_generic.png?v=1785730172"},{"product_id":"8bvp0880hc00-004-1","title":"B\u0026R 8BVP0880HC00-004-1 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Motion control \u0026gt; ACOPOSmulti \u0026gt; Power supply modules \u0026gt; Cold plate or feed-through mounting\u003c\/p\u003e\n\u003cp\u003eExtensive input voltage range Capable of regeneration Integrated connection for temperature sensors 2 slots for ACOPOSmulti plug-in modules ACOPOSmulti power supply module, 88 A, AS, cold plate or pass-through mounting.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupport\u003c\/li\u003e\n\u003cli\u003eDynamic node allocation (DNA) = Yes\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eUL = cULus E225616 Power conversion equipment\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0xA6A1\u003c\/li\u003e\n\u003cli\u003eCooling and mounting type = Cold plate or pass-through mounting\u003c\/li\u003e\n\u003cli\u003eSlots for plug-in modules = 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMains connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMax. chargeable DC bus capacitance depending on mains voltage\u003c\/li\u003e\n\u003cli\u003e230 VAC = 34.8 mF\u003c\/li\u003e\n\u003cli\u003e400 VAC = 11.5 mF\u003c\/li\u003e\n\u003cli\u003e480 VAC = 8 mF\u003c\/li\u003e\n\u003cli\u003eVariant\u003c\/li\u003e\n\u003cli\u003eL1, L2, L3, PE = M8 threaded bolts\u003c\/li\u003e\n\u003cli\u003eShield connection = Yes\u003c\/li\u003e\n\u003cli\u003eConnection cross section range\u003c\/li\u003e\n\u003cli\u003eFlexible and fine-stranded wires = ---\u003c\/li\u003e\n\u003cli\u003eNetwork configurations = TT, TN-S, TN-C-S\u003c\/li\u003e\n\u003cli\u003eMains input voltage = 3x 220 to 3x 480 VAC ±10%\u003c\/li\u003e\n\u003cli\u003eFrequency = 50 \/ 60 Hz ±4%\u003c\/li\u003e\n\u003cli\u003eTotal harmonic distortion current (THDi) = \u0026lt;0.2%\u003c\/li\u003e\n\u003cli\u003eTotal harmonic distortion voltage (THDu) = \u0026lt;1%\u003c\/li\u003e\n\u003cli\u003eInstalled load = Max. 62 kW\u003c\/li\u003e\n\u003cli\u003eInrush current at 400 VAC = Max. 133 A\u003c\/li\u003e\n\u003cli\u003eSwitch-on interval = \u0026gt;300 s\u003c\/li\u003e\n\u003cli\u003eNominal switching frequency = 5 kHz\u003c\/li\u003e\n\u003cli\u003ePossible switching frequencies = 5 \/ 10 kHz\u003c\/li\u003e\n\u003cli\u003eIntegrated line filter per EN 61800-3, category C3 = No\u003c\/li\u003e\n\u003cli\u003eIntegrated regeneration choke = No\u003c\/li\u003e\n\u003cli\u003eRegenerative = Yes\u003c\/li\u003e\n\u003cli\u003ePower factor correction (PFC) = Yes\u003c\/li\u003e\n\u003cli\u003eLine fuse = Max. 264 A (gG fuses per IEC 60269-1 or Class CC, J, T) Max. 220 A (circuit breaker per EN 60947-2 or UL 489)\u003c\/li\u003e\n\u003cli\u003eTerminal cable cross section dimension of shield connection = 32 to 50 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDC bus connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage\u003c\/li\u003e\n\u003cli\u003eNominal = 750 VDC\u003c\/li\u003e\n\u003cli\u003eReduction of continuous power depending on mains input voltage\u003c\/li\u003e\n\u003cli\u003eMains input voltage \u0026lt;3x 400 VAC = 150 W\/V * (400 V - Mains input voltage)\u003c\/li\u003e\n\u003cli\u003eReduction of continuous power depending on DC bus voltage (U DC )\u003c\/li\u003e\n\u003cli\u003eU DC \u0026lt;750 VDC = 0.08 kW\/V\u003c\/li\u003e\n\u003cli\u003eReduction of continuous power depending on switching frequency and mounting type\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz\u003c\/li\u003e\n\u003cli\u003eCold plate mounting = 1.3 kW\/K (starting at 58°C)\u003c\/li\u003e\n\u003cli\u003ePass-through mounting = In preparation\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz\u003c\/li\u003e\n\u003cli\u003eCold plate mounting = 0.95 kW\/K (starting at 27°C)\u003c\/li\u003e\n\u003cli\u003eReduction of continuous power depending on installation elevation\u003c\/li\u003e\n\u003cli\u003eStarting at 500 m above sea level = 6 kW per 1000 m\u003c\/li\u003e\n\u003cli\u003ePower dissipation depending on switching frequency\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz = [0.065*P²+11.4*P+90] W\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz = [0.22*P²+16.1*P+185] W\u003c\/li\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eOverload protection = Yes\u003c\/li\u003e\n\u003cli\u003eShort-circuit and ground fault protection = No\u003c\/li\u003e\n\u003cli\u003eContinuous power (supply and regeneration) = 60 kW\u003c\/li\u003e\n\u003cli\u003ePeak power (supply and regeneration) = 120 kW\u003c\/li\u003e\n\u003cli\u003eDC bus capacitance = 1650 µF\u003c\/li\u003e\n\u003cli\u003eVariant = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput voltage = 25 VDC ±1.6%\u003c\/li\u003e\n\u003cli\u003eInput capacitance = 4.7 µF\u003c\/li\u003e\n\u003cli\u003eMax. power consumption = 27 W + P SLOT1 + P SLOT2 + P 24 V Out + P Fan8BVF...\u003c\/li\u003e\n\u003cli\u003eVariant = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC Out\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput voltage\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 260 to 315 VDC = 25 VDC * (U DC \/ 315)\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 315 to 800 VDC = 24 VDC ±6%\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eFuse protection = 250 mA (slow-blow) electronic, automatic reset\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFilter fan connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eOverload protection = No\u003c\/li\u003e\n\u003cli\u003eShort-circuit proof = Yes\u003c\/li\u003e\n\u003cli\u003eOpen-circuit monitoring = No\u003c\/li\u003e\n\u003cli\u003eUndervoltage monitoring = No\u003c\/li\u003e\n\u003cli\u003eOutput voltage = 24 V +5.8% \/ -0.1%\u003c\/li\u003e\n\u003cli\u003eContinuous current = 4.2 A\u003c\/li\u003e\n\u003cli\u003eMax. overcurrent limiting = 10 A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrigger inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eInput - Power supply module = Yes\u003c\/li\u003e\n\u003cli\u003eInput - Input = Yes\u003c\/li\u003e\n\u003cli\u003eInput voltage\u003c\/li\u003e\n\u003cli\u003eNominal = 24 VDC\u003c\/li\u003e\n\u003cli\u003eMaximum = 30 VDC\u003c\/li\u003e\n\u003cli\u003eSwitching threshold\u003c\/li\u003e\n\u003cli\u003eLow = \u0026lt;5 V\u003c\/li\u003e\n\u003cli\u003eHigh = \u0026gt;15 V\u003c\/li\u003e\n\u003cli\u003eSwitching delay\u003c\/li\u003e\n\u003cli\u003eRising edge = 52 μs ±0.5 μs (digitally filtered)\u003c\/li\u003e\n\u003cli\u003eFalling edge = 53 μs ±0.5 μs (digitally filtered)\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eCircuit = Sink\u003c\/li\u003e\n\u003cli\u003eInput current at nominal voltage = Approx. 10 mA\u003c\/li\u003e\n\u003cli\u003eModulation compared to ground potential = Max. ±38 V\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160959799549,"sku":"8BVP0880HC00-004-1","price":13877.73,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/8BVP0880HC00-004-1.jpg?v=1785723297"},{"product_id":"8bvi0110hws0-000-1","title":"B\u0026R 8BVI0110HWS0-000-1 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Motion control \u0026gt; ACOPOSmulti \u0026gt; Inverter modules (single-axis modules) \u0026gt; Wall mounting\u003c\/p\u003e\n\u003cp\u003eACOPOSmulti inverter module, 15.1 A, AS, wall mounting.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupport\u003c\/li\u003e\n\u003cli\u003eDynamic node allocation (DNA) = Yes\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = Evaluation ongoing\u003c\/li\u003e\n\u003cli\u003eFunctional safety = Yes\u003c\/li\u003e\n\u003cli\u003eUL = cULus E225616 Power conversion equipment\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0x270E\u003c\/li\u003e\n\u003cli\u003eCooling and mounting type = Wall mounting\u003c\/li\u003e\n\u003cli\u003eSlots for plug-in modules = 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDC bus connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage\u003c\/li\u003e\n\u003cli\u003eNominal = 750 VDC\u003c\/li\u003e\n\u003cli\u003ePower dissipation depending on switching frequency\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz = [0.16 * I M ² + 5.6 * I M + 55] W\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz = [0.49 * I M ² + 4.7 * I M + 95] W\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 20 kHz = [0.87 * I M ² + 10 * I M + 200] W\u003c\/li\u003e\n\u003cli\u003eContinuous power consumption = 11.2 kW\u003c\/li\u003e\n\u003cli\u003eDC bus capacitance = 330 µF\u003c\/li\u003e\n\u003cli\u003eExecution = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput voltage = 25 VDC ±1.6%\u003c\/li\u003e\n\u003cli\u003eInput capacitance = 23.5 µF\u003c\/li\u003e\n\u003cli\u003eMax. power consumption = 12 W + P SLOT1 + P SLOT2 + P 24 V Out + P HoldingBrake\u003c\/li\u003e\n\u003cli\u003eExecution = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC output\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput voltage\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 260 to 315 VDC = 25 VDC * (U DC \/315)\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 315 to 800 VDC = 24 VDC ±6%\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eFuse protection = 250 mA (slow-blow) electronic, automatic reset\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMotor connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReduction of continuous current depending on switching frequency\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz = No reduction\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz = 0.26 A\/K (starting at 33°C)\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 20 kHz = 0.15 A\/K (starting at -28°C)\u003c\/li\u003e\n\u003cli\u003eReduction of continuous current depending on installation elevation\u003c\/li\u003e\n\u003cli\u003eStarting at 500 m above sea level = 1.51 A eff per 1000 m\u003c\/li\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eOverload protection = Yes\u003c\/li\u003e\n\u003cli\u003eShort-circuit and ground fault protection = Yes\u003c\/li\u003e\n\u003cli\u003eExecution\u003c\/li\u003e\n\u003cli\u003eU, V, W, PE = Connector\u003c\/li\u003e\n\u003cli\u003eShield connection = Yes\u003c\/li\u003e\n\u003cli\u003eTerminal connection cross section\u003c\/li\u003e\n\u003cli\u003eFlexible and fine-stranded wires\u003c\/li\u003e\n\u003cli\u003eWith wire end sleeve = 0.25 to 6 mm²\u003c\/li\u003e\n\u003cli\u003eApprobation data\u003c\/li\u003e\n\u003cli\u003eUL\/C-UL-US = 30 to 10 AWG\u003c\/li\u003e\n\u003cli\u003eCSA = 28 to 10 AWG\u003c\/li\u003e\n\u003cli\u003eMax. motor line length depending on switching frequency\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz = 25 m\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz = 25 m\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 20 kHz = 10 m\u003c\/li\u003e\n\u003cli\u003eQuantity = 1\u003c\/li\u003e\n\u003cli\u003eContinuous power per motor connection = 11 kW\u003c\/li\u003e\n\u003cli\u003eContinuous current per motor connection = 15.1 A eff\u003c\/li\u003e\n\u003cli\u003ePeak current = 37.7 A eff\u003c\/li\u003e\n\u003cli\u003eNominal switching frequency = 5 kHz\u003c\/li\u003e\n\u003cli\u003ePossible switching frequencies = 5 \/ 10 \/ 20 kHz\u003c\/li\u003e\n\u003cli\u003eInsulation stress of the connected motor per IEC TS 60034-25:2004 = Limit value curve A\u003c\/li\u003e\n\u003cli\u003eMax. output frequency = 598 Hz\u003c\/li\u003e\n\u003cli\u003eTerminal cable cross section dimension of shield connection = 12 to 22 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMotor holding brake connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eOverload and short-circuit protection = Yes\u003c\/li\u003e\n\u003cli\u003eOpen-circuit monitoring = Yes\u003c\/li\u003e\n\u003cli\u003eUndervoltage monitoring = Yes\u003c\/li\u003e\n\u003cli\u003eQuantity = 1\u003c\/li\u003e\n\u003cli\u003eOutput voltage = 24 VDC +5.8% \/ -0%\u003c\/li\u003e\n\u003cli\u003eContinuous current per connection = 2.1 A\u003c\/li\u003e\n\u003cli\u003eMax. internal resistance = 0.3 Ω\u003c\/li\u003e\n\u003cli\u003eExtinction potential = Approx. 30 V\u003c\/li\u003e\n\u003cli\u003eMax. extinction energy per switching operation = 3 Ws\u003c\/li\u003e\n\u003cli\u003eMax. switching frequency = 0.5 Hz\u003c\/li\u003e\n\u003cli\u003eResponse threshold for open-circuit monitoring = Approx. 0.5 A\u003c\/li\u003e\n\u003cli\u003eResponse threshold for undervoltage monitoring = 24 VDC +0% \/ -4%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnable inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eInput - Inverter module = Yes\u003c\/li\u003e\n\u003cli\u003eInput - Input = Yes\u003c\/li\u003e\n\u003cli\u003eInput voltage\u003c\/li\u003e\n\u003cli\u003eNominal = 24 VDC\u003c\/li\u003e\n\u003cli\u003eMaximum = 30 VDC\u003c\/li\u003e\n\u003cli\u003eSwitching threshold\u003c\/li\u003e\n\u003cli\u003eLow = \u0026lt;5 V\u003c\/li\u003e\n\u003cli\u003eHigh = \u0026gt;15 V\u003c\/li\u003e\n\u003cli\u003eSwitching delay at nominal input voltage\u003c\/li\u003e\n\u003cli\u003eEnable 1 → 0, PWM off = Max. 20.5 ms\u003c\/li\u003e\n\u003cli\u003eEnable 0 → 1, ready for PWM = Max. 100 µs\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eCircuit = Sink\u003c\/li\u003e\n\u003cli\u003eInput current at nominal voltage = Approx. 30 mA\u003c\/li\u003e\n\u003cli\u003eModulation compared to ground potential = Max. ±38 V\u003c\/li\u003e\n\u003cli\u003eOSSD signal connections = Permitted Max. test pulse length: 500 µs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrigger inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eInput - Inverter module = Yes\u003c\/li\u003e\n\u003cli\u003eInput - Input = Yes\u003c\/li\u003e\n\u003cli\u003eInput voltage\u003c\/li\u003e\n\u003cli\u003eNominal = 24 VDC\u003c\/li\u003e\n\u003cli\u003eMaximum = 30 VDC\u003c\/li\u003e\n\u003cli\u003eSwitching threshold\u003c\/li\u003e\n\u003cli\u003eLow = \u0026lt;5 V\u003c\/li\u003e\n\u003cli\u003eHigh = \u0026gt;15 V\u003c\/li\u003e\n\u003cli\u003eSwitching delay\u003c\/li\u003e\n\u003cli\u003eRising edge = 52 µs ±0.5 µs (digitally filtered)\u003c\/li\u003e\n\u003cli\u003eFalling edge = 53 µs ±0.5 µs (digitally filtered)\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eCircuit = Sink\u003c\/li\u003e\n\u003cli\u003eInput current at nominal voltage = Approx. 10 mA\u003c\/li\u003e\n\u003cli\u003eModulation compared to ground potential = Max. ±38 V\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160960585981,"sku":"8BVI0110HWS0-000-1","price":2848.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/8BVI0110HWS0-000-1.jpg?v=1785723256"},{"product_id":"8bvp0220hw00-0001","title":"B\u0026R 8BVP0220HW00-0001 | B\u0026R","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Motion control \u0026gt; ACOPOSmulti \u0026gt; Power supply modules \u0026gt; Wall mounting\u003c\/p\u003e\n\u003cp\u003eWide input voltage range Capable of regeneration Integrated connection for temperature sensors 2 slots for ACOPOSmulti plug-in modules ACOPOSmulti power supply module, 22 A, AS, wall mounting.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupport\u003c\/li\u003e\n\u003cli\u003eDynamic node allocation (DNA) = Yes\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = Evaluation ongoing\u003c\/li\u003e\n\u003cli\u003eUL = cULus E225616 Power conversion equipment\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0xA7CF\u003c\/li\u003e\n\u003cli\u003eCooling and mounting type = Wall mounting\u003c\/li\u003e\n\u003cli\u003eSlots for plug-in modules = 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMains connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMax. chargeable DC bus capacitance depending on mains voltage\u003c\/li\u003e\n\u003cli\u003e230 VAC = 17.4 mF\u003c\/li\u003e\n\u003cli\u003e400 VAC = 5.8 mF\u003c\/li\u003e\n\u003cli\u003e480 VAC = 4 mF\u003c\/li\u003e\n\u003cli\u003eVariant\u003c\/li\u003e\n\u003cli\u003eL1, L2, L3, PE = Connector\u003c\/li\u003e\n\u003cli\u003ePE = M5 threaded bolt\u003c\/li\u003e\n\u003cli\u003eShield connection = Yes\u003c\/li\u003e\n\u003cli\u003eTerminal connection cross section\u003c\/li\u003e\n\u003cli\u003eFlexible and fine-stranded wires\u003c\/li\u003e\n\u003cli\u003eWith wire end sleeve = 0.5 to 16 mm²\u003c\/li\u003e\n\u003cli\u003eApprobation data\u003c\/li\u003e\n\u003cli\u003eUL\/C-UL-US = 20 to 6 AWG\u003c\/li\u003e\n\u003cli\u003eCSA = 20 to 6 AWG\u003c\/li\u003e\n\u003cli\u003eNetwork configurations = TT, TN-S, TN-C-S\u003c\/li\u003e\n\u003cli\u003eMains input voltage = 3x 220 to 3x 480 VAC ±10%\u003c\/li\u003e\n\u003cli\u003eFrequency = 50 \/ 60 Hz ±4%\u003c\/li\u003e\n\u003cli\u003eInstalled load = Max. 15.6 kW\u003c\/li\u003e\n\u003cli\u003eInrush current at 400 VAC = Max. 67 A\u003c\/li\u003e\n\u003cli\u003eSwitch-on interval = \u0026gt;300 s\u003c\/li\u003e\n\u003cli\u003eNominal switching frequency = 5 kHz\u003c\/li\u003e\n\u003cli\u003ePossible switching frequencies = 5 \/ 10 kHz\u003c\/li\u003e\n\u003cli\u003eIntegrated line filter per EN 61800-3, category C3 = No\u003c\/li\u003e\n\u003cli\u003eIntegrated regeneration choke = No\u003c\/li\u003e\n\u003cli\u003eRegenerative = Yes\u003c\/li\u003e\n\u003cli\u003ePower factor correction (PFC) = Yes\u003c\/li\u003e\n\u003cli\u003eLine fuse = Max. 66 A (gG fuses per IEC 60269-1 or Class CC, J, T) Max. 55 A (circuit breaker per EN 60947-2 or UL 489)\u003c\/li\u003e\n\u003cli\u003eTerminal cable cross section dimension of shield connection = 23 to 35 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDC bus connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage\u003c\/li\u003e\n\u003cli\u003eNominal = 750 VDC\u003c\/li\u003e\n\u003cli\u003eReduction of continuous power depending on mains input voltage\u003c\/li\u003e\n\u003cli\u003eMains input voltage \u0026lt;3x 400 VAC = 37.5 W\/V * (400 V - Mains input voltage)\u003c\/li\u003e\n\u003cli\u003eReduction of continuous power depending on DC bus voltage (U DC )\u003c\/li\u003e\n\u003cli\u003eU DC \u0026lt;750 VDC = P * (1 - U DC \/750)\u003c\/li\u003e\n\u003cli\u003eReduction of continuous power depending on switching frequency\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz = No reduction\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz = 0.27 kW\/K (starting at 31°C)\u003c\/li\u003e\n\u003cli\u003eReduction of continuous power depending on installation elevation\u003c\/li\u003e\n\u003cli\u003eStarting at 500 m above sea level = 1.5 kW per 1000 m\u003c\/li\u003e\n\u003cli\u003eReduction of peak power depending on mains input voltage\u003c\/li\u003e\n\u003cli\u003eMains input voltage \u0026lt;3x 400 VAC = 94 W\/V * (400 V - Mains input voltage)\u003c\/li\u003e\n\u003cli\u003ePower dissipation depending on switching frequency\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz = [0.28*P²+7.9*P+40] W\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz = [0.9*P²+5.3*P+110] W\u003c\/li\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eOverload protection = Yes\u003c\/li\u003e\n\u003cli\u003eShort-circuit and ground fault protection = No\u003c\/li\u003e\n\u003cli\u003eContinuous power (supply and regeneration) = 15 kW\u003c\/li\u003e\n\u003cli\u003ePeak power (supply and regeneration) = 37.5 kW\u003c\/li\u003e\n\u003cli\u003eDC bus capacitance = 495 µF\u003c\/li\u003e\n\u003cli\u003eVariant = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput voltage = 25 VDC ±1.6%\u003c\/li\u003e\n\u003cli\u003eInput capacitance = 4.7 µF\u003c\/li\u003e\n\u003cli\u003eMax. power consumption = 27 W + P SLOT1 + P SLOT2 + P 24 V Out + P Fan8BVF...\u003c\/li\u003e\n\u003cli\u003eVariant = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC Out\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput voltage\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 260 to 315 VDC = 25 VDC * (U DC \/ 315)\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 315 to 800 VDC = 24 VDC ±6%\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eFuse protection = 250 mA (slow-blow) electronic, automatic reset\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFilter fan connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eOverload protection = No\u003c\/li\u003e\n\u003cli\u003eShort-circuit proof = Yes\u003c\/li\u003e\n\u003cli\u003eOpen-circuit monitoring = No\u003c\/li\u003e\n\u003cli\u003eUndervoltage monitoring = No\u003c\/li\u003e\n\u003cli\u003eOutput voltage = 24 V +5.8% \/ -0.1%\u003c\/li\u003e\n\u003cli\u003eContinuous current = 4.2 A\u003c\/li\u003e\n\u003cli\u003eMax. overcurrent limiting = 10 A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrigger inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eInput - Power supply module = Yes\u003c\/li\u003e\n\u003cli\u003eInput - Input = Yes\u003c\/li\u003e\n\u003cli\u003eInput voltage\u003c\/li\u003e\n\u003cli\u003eNominal = 24 VDC\u003c\/li\u003e\n\u003cli\u003eMaximum = 30 VDC\u003c\/li\u003e\n\u003cli\u003eSwitching threshold\u003c\/li\u003e\n\u003cli\u003eLow = \u0026lt;5 V\u003c\/li\u003e\n\u003cli\u003eHigh = \u0026gt;15 V\u003c\/li\u003e\n\u003cli\u003eSwitching delay\u003c\/li\u003e\n\u003cli\u003eRising edge = 52 μs ±0.5 μs (digitally filtered)\u003c\/li\u003e\n\u003cli\u003eFalling edge = 53 μs ±0.5 μs (digitally filtered)\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eCircuit = Sink\u003c\/li\u003e\n\u003cli\u003eInput current at nominal voltage = Approx. 10 mA\u003c\/li\u003e\n\u003cli\u003eModulation compared to ground potential = Max. ±38 V\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"Never Used Surplus","offer_id":70984808464637,"sku":"8BVP0220HW00-0001","price":12541.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/8BVP0220HW00-0001.jpg?v=1785722917"},{"product_id":"8bvi0110hwd0-0001","title":"B\u0026R 8BVI0110HWD0-0001 | B\u0026R","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Motion control \u0026gt; ACOPOSmulti \u0026gt; Inverter modules (two-axis modules) \u0026gt; Wall mounting\u003c\/p\u003e\n\u003cp\u003eIntegrated uncontrolled standstill and safe stop Integrated connection for motor holding brake and temperature sensor 2 slots for ACOPOSmulti plug-in modules Two fully independent power inverters in one inverter module contained in 2-axis modules ACOPOSmulti inverter module, 15.1 A, AS, wall mounting, 2 axes.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupport\u003c\/li\u003e\n\u003cli\u003eDynamic node allocation (DNA) = Yes\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = Evaluation ongoing\u003c\/li\u003e\n\u003cli\u003eFunctional safety = Yes\u003c\/li\u003e\n\u003cli\u003eUL = cULus E225616 Power conversion equipment\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0xA8E5\u003c\/li\u003e\n\u003cli\u003eCooling and mounting type = Wall mounting\u003c\/li\u003e\n\u003cli\u003eSlots for plug-in modules = 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDC bus connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage\u003c\/li\u003e\n\u003cli\u003eNominal = 750 VDC\u003c\/li\u003e\n\u003cli\u003ePower dissipation depending on switching frequency\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz = [0.33 * I M ² + 11 * I M + 90] W\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz = [0.97 * I M ² + 9.5 * I M + 170] W\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 20 kHz = [1.66 * I M ² + 21 * I M + 380] W\u003c\/li\u003e\n\u003cli\u003eContinuous power consumption = 22.3 kW\u003c\/li\u003e\n\u003cli\u003eDC bus capacitance = 660 µF\u003c\/li\u003e\n\u003cli\u003eExecution = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput voltage = 25 VDC ±1.6%\u003c\/li\u003e\n\u003cli\u003eInput capacitance = 23.5 µF\u003c\/li\u003e\n\u003cli\u003eMax. power consumption = 20 W + P SLOT1 + P SLOT2 + P 24 V Out + P HoldingBrake(s)\u003c\/li\u003e\n\u003cli\u003eExecution = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC output\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput voltage\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 260 to 315 VDC = 25 VDC * (U DC \/315)\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 315 to 800 VDC = 24 VDC ±6%\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eFuse protection = 250 mA (slow-blow) electronic, automatic reset\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMotor connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReduction of continuous current depending on switching frequency\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz = No reduction\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz = 0.19 A\/K (starting at 29°C)\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 20 kHz = 0.15 A\/K (starting at -38°C)\u003c\/li\u003e\n\u003cli\u003eReduction of continuous current depending on installation elevation\u003c\/li\u003e\n\u003cli\u003eStarting at 500 m above sea level = 1.51 A eff per 1000 m\u003c\/li\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eOverload protection = Yes\u003c\/li\u003e\n\u003cli\u003eShort-circuit and ground fault protection = Yes\u003c\/li\u003e\n\u003cli\u003eExecution\u003c\/li\u003e\n\u003cli\u003eU, V, W, PE = Connector\u003c\/li\u003e\n\u003cli\u003eShield connection = Yes\u003c\/li\u003e\n\u003cli\u003eTerminal connection cross section\u003c\/li\u003e\n\u003cli\u003eFlexible and fine-stranded wires\u003c\/li\u003e\n\u003cli\u003eWith wire end sleeve = 0.25 to 6 mm²\u003c\/li\u003e\n\u003cli\u003eApprobation data\u003c\/li\u003e\n\u003cli\u003eUL\/C-UL-US = 30 to 10 AWG\u003c\/li\u003e\n\u003cli\u003eCSA = 28 to 10 AWG\u003c\/li\u003e\n\u003cli\u003eMax. motor line length depending on switching frequency\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz = 25 m\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz = 25 m\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 20 kHz = 10 m\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eContinuous power per motor connection = 11 kW\u003c\/li\u003e\n\u003cli\u003eContinuous current per motor connection = 15.1 A eff\u003c\/li\u003e\n\u003cli\u003ePeak current per motor connection = 37.7 A eff\u003c\/li\u003e\n\u003cli\u003eNominal switching frequency = 5 kHz\u003c\/li\u003e\n\u003cli\u003ePossible switching frequencies = 5 \/ 10 \/ 20 kHz\u003c\/li\u003e\n\u003cli\u003eInsulation stress of the connected motor per IEC TS 60034-25:2004 = Limit value curve A\u003c\/li\u003e\n\u003cli\u003eMax. output frequency = 598 Hz\u003c\/li\u003e\n\u003cli\u003eTerminal cable cross section dimension of shield connection = 12 to 22 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMotor holding brake connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eOverload and short-circuit protection = Yes\u003c\/li\u003e\n\u003cli\u003eOpen-circuit monitoring = Yes\u003c\/li\u003e\n\u003cli\u003eUndervoltage monitoring = Yes\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eOutput voltage = 24 VDC +5.8% \/ -0%\u003c\/li\u003e\n\u003cli\u003eContinuous current per connection = 2.1 A\u003c\/li\u003e\n\u003cli\u003eMax. internal resistance = 0.3 Ω\u003c\/li\u003e\n\u003cli\u003eExtinction potential = Approx. 30 V\u003c\/li\u003e\n\u003cli\u003eMax. extinction energy per switching operation = 3 Ws\u003c\/li\u003e\n\u003cli\u003eMax. switching frequency = 0.5 Hz\u003c\/li\u003e\n\u003cli\u003eResponse threshold for open-circuit monitoring = Approx. 0.5 A\u003c\/li\u003e\n\u003cli\u003eResponse threshold for undervoltage monitoring = 24 VDC +0% \/ -4%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnable inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eInput - Inverter module = Yes\u003c\/li\u003e\n\u003cli\u003eInput - Input = Yes\u003c\/li\u003e\n\u003cli\u003eInput voltage\u003c\/li\u003e\n\u003cli\u003eNominal = 24 VDC\u003c\/li\u003e\n\u003cli\u003eMaximum = 30 VDC\u003c\/li\u003e\n\u003cli\u003eSwitching threshold\u003c\/li\u003e\n\u003cli\u003eLow = \u0026lt;5 V\u003c\/li\u003e\n\u003cli\u003eHigh = \u0026gt;15 V\u003c\/li\u003e\n\u003cli\u003eSwitching delay at nominal input voltage\u003c\/li\u003e\n\u003cli\u003eEnable 1 → 0, PWM off = Max. 20.5 ms\u003c\/li\u003e\n\u003cli\u003eEnable 0 → 1, ready for PWM = Max. 100 µs\u003c\/li\u003e\n\u003cli\u003eQuantity = 4 (2 per axis)\u003c\/li\u003e\n\u003cli\u003eCircuit = Sink\u003c\/li\u003e\n\u003cli\u003eInput current at nominal voltage = Approx. 30 mA\u003c\/li\u003e\n\u003cli\u003eModulation compared to ground potential = Max. ±38 V\u003c\/li\u003e\n\u003cli\u003eOSSD signal connections = Permitted Max. test pulse length: 500 µs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"Never Used Surplus","offer_id":70984809185533,"sku":"8BVI0110HWD0-0001","price":10250.36,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/8BVI0110HWD0-0001.jpg?v=1785722900"},{"product_id":"8bvi0330hws0-000-1","title":"B\u0026R 8BVI0330HWS0-000-1 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Motion control \u0026gt; ACOPOSmulti \u0026gt; Inverter modules (single-axis modules) \u0026gt; Wall mounting\u003c\/p\u003e\n\u003cp\u003eUncontrolled stops and safe stop integrated Integrated connection for motor motor holding brake and temperature sensor 2 slots for ACOPOSmulti plug-in modules ACOPOSmulti inverter module, 33 A, AS, wall mounting.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupport\u003c\/li\u003e\n\u003cli\u003eDynamic node allocation (DNA) = Yes\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = Evaluation ongoing\u003c\/li\u003e\n\u003cli\u003eFunctional safety = Yes\u003c\/li\u003e\n\u003cli\u003eUL = cULus E225616 Power conversion equipment\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0xAD78\u003c\/li\u003e\n\u003cli\u003eCooling and mounting type = Wall mounting\u003c\/li\u003e\n\u003cli\u003eSlots for plug-in modules = 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDC bus connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage\u003c\/li\u003e\n\u003cli\u003eNominal = 750 VDC\u003c\/li\u003e\n\u003cli\u003ePower dissipation depending on switching frequency\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz = [0.07 * I M ² + 7.3 * I M + 40] W\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz = [0.2 * I M ² + 11.1 * I M + 130] W\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 20 kHz = [1.85 * I M ² + 3.8 * I M + 300] W\u003c\/li\u003e\n\u003cli\u003eContinuous power consumption = 24.4 kW\u003c\/li\u003e\n\u003cli\u003eDC bus capacitance = 990 µF\u003c\/li\u003e\n\u003cli\u003eVariant = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput voltage = 25 VDC ±1.6%\u003c\/li\u003e\n\u003cli\u003eInput capacitance = 32.9 µF\u003c\/li\u003e\n\u003cli\u003eMax. power consumption = 25 W + P SLOT1 + P SLOT2 + P 24 V Out + P HoldingBrake\u003c\/li\u003e\n\u003cli\u003eVariant = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC output\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput voltage\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 260 to 315 VDC = 25 VDC * (U DC \/315)\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 315 to 800 VDC = 24 VDC ±6%\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eFuse protection = 250 mA (slow-blow) electronic, automatic reset\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMotor connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReduction of continuous current depending on switching frequency\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz = 1.57 A\/K (starting at 40°C)\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz = 0.5 A\/K (starting at -10°C)\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 20 kHz = 0.36 A\/K (starting at -77°C)\u003c\/li\u003e\n\u003cli\u003eReduction of continuous current depending on installation elevation\u003c\/li\u003e\n\u003cli\u003eStarting at 500 m above sea level = 3.3 A eff per 1000 m\u003c\/li\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eOverload protection = Yes\u003c\/li\u003e\n\u003cli\u003eShort-circuit and ground fault protection = Yes\u003c\/li\u003e\n\u003cli\u003eVariant\u003c\/li\u003e\n\u003cli\u003eU, V, W, PE = Connector\u003c\/li\u003e\n\u003cli\u003eShield connection = Yes\u003c\/li\u003e\n\u003cli\u003eTerminal connection cross section\u003c\/li\u003e\n\u003cli\u003eFlexible and fine-stranded wires\u003c\/li\u003e\n\u003cli\u003eWith wire end sleeve = 0.5 to 16 mm²\u003c\/li\u003e\n\u003cli\u003eApprobation data\u003c\/li\u003e\n\u003cli\u003eUL\/C-UL-US = 20 to 6 AWG\u003c\/li\u003e\n\u003cli\u003eCSA = 20 to 6 AWG\u003c\/li\u003e\n\u003cli\u003eMax. motor line length depending on switching frequency\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz = 25 m\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz = 25 m\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 20 kHz = 25 m\u003c\/li\u003e\n\u003cli\u003eQuantity = 1\u003c\/li\u003e\n\u003cli\u003eContinuous power per motor connection = 24 kW\u003c\/li\u003e\n\u003cli\u003eContinuous current per motor connection = 33 A eff\u003c\/li\u003e\n\u003cli\u003ePeak current = 83 A eff\u003c\/li\u003e\n\u003cli\u003eNominal switching frequency = 5 kHz\u003c\/li\u003e\n\u003cli\u003ePossible switching frequencies = 5 \/ 10 \/ 20 kHz\u003c\/li\u003e\n\u003cli\u003eInsulation stress of the connected motor per IEC TS 60034-25:2004 = Limit value curve A\u003c\/li\u003e\n\u003cli\u003eMax. output frequency = 598 Hz\u003c\/li\u003e\n\u003cli\u003eTerminal cable cross section dimension of shield connection = 23 to 35 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMotor holding brake connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eOverload and short-circuit protection = Yes\u003c\/li\u003e\n\u003cli\u003eOpen-circuit monitoring = Yes\u003c\/li\u003e\n\u003cli\u003eUndervoltage monitoring = Yes\u003c\/li\u003e\n\u003cli\u003eQuantity = 1\u003c\/li\u003e\n\u003cli\u003eOutput voltage = 24 VDC +5.8% \/ -0%\u003c\/li\u003e\n\u003cli\u003eContinuous current per connection = 4.2 A\u003c\/li\u003e\n\u003cli\u003eMax. internal resistance = 0.15 Ω\u003c\/li\u003e\n\u003cli\u003eExtinction potential = Approx. 30 V\u003c\/li\u003e\n\u003cli\u003eMax. extinction energy per switching operation = 3 Ws\u003c\/li\u003e\n\u003cli\u003eMax. switching frequency = 0.5 Hz\u003c\/li\u003e\n\u003cli\u003eResponse threshold for open-circuit monitoring = Approx. 0.5 A\u003c\/li\u003e\n\u003cli\u003eResponse threshold for undervoltage monitoring = 24 VDC +0% \/ -4%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnable inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eInput - Inverter module = Yes\u003c\/li\u003e\n\u003cli\u003eInput - Input = Yes\u003c\/li\u003e\n\u003cli\u003eInput voltage\u003c\/li\u003e\n\u003cli\u003eNominal = 24 VDC\u003c\/li\u003e\n\u003cli\u003eMaximum = 30 VDC\u003c\/li\u003e\n\u003cli\u003eSwitching threshold\u003c\/li\u003e\n\u003cli\u003eLow = \u0026lt;5 V\u003c\/li\u003e\n\u003cli\u003eHigh = \u0026gt;15 V\u003c\/li\u003e\n\u003cli\u003eSwitching delay at nominal input voltage\u003c\/li\u003e\n\u003cli\u003eEnable 1 → 0, PWM off = Max. 20.5 ms\u003c\/li\u003e\n\u003cli\u003eEnable 0 → 1, ready for PWM = Max. 100 µs\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eCircuit = Sink\u003c\/li\u003e\n\u003cli\u003eInput current at nominal voltage = Approx. 30 mA\u003c\/li\u003e\n\u003cli\u003eModulation compared to ground potential = Max. ±38 V\u003c\/li\u003e\n\u003cli\u003eOSSD signal connections = Permitted Max. test pulse length: 500 µs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrigger inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eInput - Inverter module = Yes\u003c\/li\u003e\n\u003cli\u003eInput - Input = Yes\u003c\/li\u003e\n\u003cli\u003eInput voltage\u003c\/li\u003e\n\u003cli\u003eNominal = 24 VDC\u003c\/li\u003e\n\u003cli\u003eMaximum = 30 VDC\u003c\/li\u003e\n\u003cli\u003eSwitching threshold\u003c\/li\u003e\n\u003cli\u003eLow = \u0026lt;5 V\u003c\/li\u003e\n\u003cli\u003eHigh = \u0026gt;15 V\u003c\/li\u003e\n\u003cli\u003eSwitching delay\u003c\/li\u003e\n\u003cli\u003eRising edge = 52 µs ±0.5 µs (digitally filtered)\u003c\/li\u003e\n\u003cli\u003eFalling edge = 53 µs ±0.5 µs (digitally filtered)\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eCircuit = Sink\u003c\/li\u003e\n\u003cli\u003eInput current at nominal voltage = Approx. 10 mA\u003c\/li\u003e\n\u003cli\u003eModulation compared to ground potential = Max. ±38 V\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160961437949,"sku":"8BVI0330HWS0-000-1","price":8189.47,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/8BVI0330HWS0-000-1.jpg?v=1785723283"},{"product_id":"8bvi0055hwd0-000-1","title":"B\u0026R 8BVI0055HWD0-000-1 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Motion control \u0026gt; ACOPOSmulti \u0026gt; Inverter modules (two-axis modules) \u0026gt; Wall mounting\u003c\/p\u003e\n\u003cp\u003eIntegrated uncontrolled standstill and safe stop Integrated connection for motor holding brake and temperature sensor 2 slots for ACOPOSmulti plug-in modules Two fully independent power inverters in one inverter module contained in 2-axis modules ACOPOSmulti inverter module, 7.6 A, AS, wall mounting, 2 axes.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupport\u003c\/li\u003e\n\u003cli\u003eDynamic node allocation (DNA) = Yes\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = Evaluation ongoing\u003c\/li\u003e\n\u003cli\u003eFunctional safety = Yes\u003c\/li\u003e\n\u003cli\u003eUL = cULus E225616 Power conversion equipment\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0x20B5\u003c\/li\u003e\n\u003cli\u003eCooling and mounting type = Wall mounting\u003c\/li\u003e\n\u003cli\u003eSlots for plug-in modules = 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDC bus connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage\u003c\/li\u003e\n\u003cli\u003eNominal = 750 VDC\u003c\/li\u003e\n\u003cli\u003ePower dissipation depending on switching frequency\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz = [1.2 * I M ² + 2.62 * I M + 100] W\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz = [2.56 * I M ² + 2.8 * I M + 200] W\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 20 kHz = [6 * I M ² - 9.4 * I M + 430] W\u003c\/li\u003e\n\u003cli\u003eContinuous power consumption = 11.19 kW\u003c\/li\u003e\n\u003cli\u003eDC bus capacitance = 330 µF\u003c\/li\u003e\n\u003cli\u003eVariant = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput voltage = 25 VDC ±1.6%\u003c\/li\u003e\n\u003cli\u003eInput capacitance = 23.5 µF\u003c\/li\u003e\n\u003cli\u003eMax. power consumption = 16 W + P SLOT1 + P SLOT2 + P 24 V Out + P HoldingBrake(s)\u003c\/li\u003e\n\u003cli\u003eVariant = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC output\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput voltage\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 260 to 315 VDC = 25 VDC * (U DC \/315)\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 315 to 800 VDC = 24 VDC ±6%\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eFuse protection = 250 mA (slow-blow) electronic, automatic reset\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMotor connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReduction of continuous current depending on switching frequency\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz = No reduction\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz = 0.22 A\/K (starting at 43°C)\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 20 kHz = 0.15 A\/K (starting at -14°C)\u003c\/li\u003e\n\u003cli\u003eReduction of continuous current depending on installation elevation\u003c\/li\u003e\n\u003cli\u003eStarting at 500 m above sea level = 0.76 A eff per 1000 m\u003c\/li\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eOverload protection = Yes\u003c\/li\u003e\n\u003cli\u003eShort-circuit and ground fault protection = Yes\u003c\/li\u003e\n\u003cli\u003eVariant\u003c\/li\u003e\n\u003cli\u003eU, V, W, PE = Connector\u003c\/li\u003e\n\u003cli\u003eShield connection = Yes\u003c\/li\u003e\n\u003cli\u003eTerminal connection cross section\u003c\/li\u003e\n\u003cli\u003eFlexible and fine-stranded wires\u003c\/li\u003e\n\u003cli\u003eWith wire end sleeve = 0.25 to 6 mm²\u003c\/li\u003e\n\u003cli\u003eApprobation data\u003c\/li\u003e\n\u003cli\u003eUL\/C-UL-US = 30 to 10 AWG\u003c\/li\u003e\n\u003cli\u003eCSA = 28 to 10 AWG\u003c\/li\u003e\n\u003cli\u003eMax. motor line length depending on switching frequency\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz = 25 m\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz = 25 m\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 20 kHz = 10 m\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eContinuous power per motor connection = 5.5 kW\u003c\/li\u003e\n\u003cli\u003eContinuous current per motor connection = 7.6 A eff\u003c\/li\u003e\n\u003cli\u003ePeak current per motor connection = 18.9 A eff\u003c\/li\u003e\n\u003cli\u003eNominal switching frequency = 5 kHz\u003c\/li\u003e\n\u003cli\u003ePossible switching frequencies = 5 \/ 10 \/ 20 kHz\u003c\/li\u003e\n\u003cli\u003eInsulation stress of the connected motor per IEC TS 60034-25:2004 = Limit value curve A\u003c\/li\u003e\n\u003cli\u003eMax. output frequency = 598 Hz\u003c\/li\u003e\n\u003cli\u003eTerminal cable cross section dimension of shield connection = 12 to 22 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMotor holding brake connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eOverload and short-circuit protection = Yes\u003c\/li\u003e\n\u003cli\u003eOpen-circuit monitoring = Yes\u003c\/li\u003e\n\u003cli\u003eUndervoltage monitoring = Yes\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eOutput voltage = 24 VDC +5.8% \/ -0%\u003c\/li\u003e\n\u003cli\u003eContinuous current per connection = 1.1 A\u003c\/li\u003e\n\u003cli\u003eMax. internal resistance = 0.5 Ω\u003c\/li\u003e\n\u003cli\u003eExtinction potential = Approx. 30 V\u003c\/li\u003e\n\u003cli\u003eMax. extinction energy per switching operation = 1.5 Ws\u003c\/li\u003e\n\u003cli\u003eMax. switching frequency = 0.5 Hz\u003c\/li\u003e\n\u003cli\u003eResponse threshold for open-circuit monitoring = Approx. 0.25 A\u003c\/li\u003e\n\u003cli\u003eResponse threshold for undervoltage monitoring = 24 VDC +0% \/ -4%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnable inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eInput - Inverter module = Yes\u003c\/li\u003e\n\u003cli\u003eInput - Input = Yes\u003c\/li\u003e\n\u003cli\u003eInput voltage\u003c\/li\u003e\n\u003cli\u003eNominal = 24 VDC\u003c\/li\u003e\n\u003cli\u003eMaximum = 30 VDC\u003c\/li\u003e\n\u003cli\u003eSwitching threshold\u003c\/li\u003e\n\u003cli\u003eLow = \u0026lt;5 V\u003c\/li\u003e\n\u003cli\u003eHigh = \u0026gt;15 V\u003c\/li\u003e\n\u003cli\u003eSwitching delay at nominal input voltage\u003c\/li\u003e\n\u003cli\u003eEnable 1 → 0, PWM off = Max. 20.5 ms\u003c\/li\u003e\n\u003cli\u003eEnable 0 → 1, ready for PWM = Max. 100 µs\u003c\/li\u003e\n\u003cli\u003eQuantity = 4 (2 per axis)\u003c\/li\u003e\n\u003cli\u003eCircuit = Sink\u003c\/li\u003e\n\u003cli\u003eInput current at nominal voltage = Approx. 30 mA\u003c\/li\u003e\n\u003cli\u003eModulation compared to ground potential = Max. ±38 V\u003c\/li\u003e\n\u003cli\u003eOSSD signal connections = Permitted Max. test pulse length: 500 µs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160961667325,"sku":"8BVI0055HWD0-000-1","price":6930.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/8BVI0055HWD0.jpg?v=1785731011"},{"product_id":"8bvi0055hcd0-0001","title":"B\u0026R 8BVI0055HCD0-0001 | B\u0026R","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Motion control \u0026gt; ACOPOSmulti \u0026gt; Inverter modules (two-axis modules) \u0026gt; Cold plate or feed-through mounting\u003c\/p\u003e\n\u003cp\u003eIntegrated uncontrolled standstill and safe stop Integrated connection for motor holding brake and temperature sensor 2 slots for ACOPOSmulti plug-in modules Two fully independent power inverters in one inverter module contained in 2-axis modules ACOPOSmulti inverter module, 7.6 A, AS, cold plate or pass-through mounting, 2 axes.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupport\u003c\/li\u003e\n\u003cli\u003eDynamic node allocation (DNA) = Yes\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = Evaluation ongoing\u003c\/li\u003e\n\u003cli\u003eFunctional safety = Yes\u003c\/li\u003e\n\u003cli\u003eUL = cULus E225616 Power conversion equipment\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0x200D\u003c\/li\u003e\n\u003cli\u003eCooling and mounting type = Cold plate or pass-through mounting\u003c\/li\u003e\n\u003cli\u003eSlots for plug-in modules = 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDC bus connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage\u003c\/li\u003e\n\u003cli\u003eNominal = 750 VDC\u003c\/li\u003e\n\u003cli\u003ePower dissipation depending on switching frequency\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz = [1.2 * I M ² + 2.62 * I M + 100] W\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz = [2.56 * I M ² + 2.8 * I M + 200] W\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 20 kHz = [6 * I M ² - 9.4 * I M + 430] W\u003c\/li\u003e\n\u003cli\u003eContinuous power consumption = 11.19 kW\u003c\/li\u003e\n\u003cli\u003eDC bus capacitance = 330 µF\u003c\/li\u003e\n\u003cli\u003eVariant = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput voltage = 25 VDC ±1.6%\u003c\/li\u003e\n\u003cli\u003eInput capacitance = 23.5 µF\u003c\/li\u003e\n\u003cli\u003eMax. power consumption = 16 W + P SLOT1 + P SLOT2 + P 24 V Out + P HoldingBrake(s)\u003c\/li\u003e\n\u003cli\u003eVariant = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC output\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput voltage\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 260 to 315 VDC = 25 VDC * (U DC \/315)\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 315 to 800 VDC = 24 VDC ±6%\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eFuse protection = 250 mA (slow-blow) electronic, automatic reset\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMotor connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReduction of continuous current depending on switching frequency and mounting type\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz\u003c\/li\u003e\n\u003cli\u003eCold plate mounting = 0.72 A\/K (starting at 56°C)\u003c\/li\u003e\n\u003cli\u003ePass-through mounting = No reduction\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz\u003c\/li\u003e\n\u003cli\u003eCold plate mounting = 0.28 A\/K (starting at 43°C)\u003c\/li\u003e\n\u003cli\u003ePass-through mounting = 0.17 A\/K (starting at 23°C)\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 20 kHz\u003c\/li\u003e\n\u003cli\u003eCold plate mounting = 0.13 A\/K (starting at 3°C)\u003c\/li\u003e\n\u003cli\u003ePass-through mounting = 0.12 A\/K (starting at -21°C)\u003c\/li\u003e\n\u003cli\u003eReduction of continuous current depending on installation elevation\u003c\/li\u003e\n\u003cli\u003eStarting at 500 m above sea level = 0.76 A eff per 1000 m\u003c\/li\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eOverload protection = Yes\u003c\/li\u003e\n\u003cli\u003eShort-circuit and ground fault protection = Yes\u003c\/li\u003e\n\u003cli\u003eVariant\u003c\/li\u003e\n\u003cli\u003eU, V, W, PE = Connector\u003c\/li\u003e\n\u003cli\u003eShield connection = Yes\u003c\/li\u003e\n\u003cli\u003eTerminal connection cross section\u003c\/li\u003e\n\u003cli\u003eFlexible and fine-stranded wires\u003c\/li\u003e\n\u003cli\u003eWith wire end sleeve = 0.25 to 6 mm²\u003c\/li\u003e\n\u003cli\u003eApprobation data\u003c\/li\u003e\n\u003cli\u003eUL\/C-UL-US = 30 to 10 AWG\u003c\/li\u003e\n\u003cli\u003eCSA = 28 to 10 AWG\u003c\/li\u003e\n\u003cli\u003eMax. motor line length depending on switching frequency\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz = 25 m\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz = 25 m\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 20 kHz = 10 m\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eContinuous power per motor connection = 5.5 kW\u003c\/li\u003e\n\u003cli\u003eContinuous current per motor connection = 7.6 A eff\u003c\/li\u003e\n\u003cli\u003ePeak current per motor connection = 18.9 A eff\u003c\/li\u003e\n\u003cli\u003eNominal switching frequency = 5 kHz\u003c\/li\u003e\n\u003cli\u003ePossible switching frequencies = 5 \/ 10 \/ 20 kHz\u003c\/li\u003e\n\u003cli\u003eInsulation stress of the connected motor per IEC TS 60034-25:2004 = Limit value curve A\u003c\/li\u003e\n\u003cli\u003eMax. output frequency = 598 Hz\u003c\/li\u003e\n\u003cli\u003eTerminal cable cross section dimension of shield connection = 12 to 22 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMotor holding brake connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eOverload and short-circuit protection = Yes\u003c\/li\u003e\n\u003cli\u003eOpen-circuit monitoring = Yes\u003c\/li\u003e\n\u003cli\u003eUndervoltage monitoring = Yes\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eOutput voltage = 24 VDC +5.8% \/ -0%\u003c\/li\u003e\n\u003cli\u003eContinuous current per connection = 1.1 A\u003c\/li\u003e\n\u003cli\u003eMax. internal resistance = 0.5 Ω\u003c\/li\u003e\n\u003cli\u003eExtinction potential = Approx. 30 V\u003c\/li\u003e\n\u003cli\u003eMax. extinction energy per switching operation = 1.5 Ws\u003c\/li\u003e\n\u003cli\u003eMax. switching frequency = 0.5 Hz\u003c\/li\u003e\n\u003cli\u003eResponse threshold for open-circuit monitoring = Approx. 0.25 A\u003c\/li\u003e\n\u003cli\u003eResponse threshold for undervoltage monitoring = 24 VDC +0% \/ -4%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnable inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eInput - Inverter module = Yes\u003c\/li\u003e\n\u003cli\u003eInput - Input = Yes\u003c\/li\u003e\n\u003cli\u003eInput voltage\u003c\/li\u003e\n\u003cli\u003eNominal = 24 VDC\u003c\/li\u003e\n\u003cli\u003eMaximum = 30 VDC\u003c\/li\u003e\n\u003cli\u003eSwitching threshold\u003c\/li\u003e\n\u003cli\u003eLow = \u0026lt;5 V\u003c\/li\u003e\n\u003cli\u003eHigh = \u0026gt;15 V\u003c\/li\u003e\n\u003cli\u003eSwitching delay at nominal input voltage\u003c\/li\u003e\n\u003cli\u003eEnable 1 → 0, PWM off = Max. 20.5 ms\u003c\/li\u003e\n\u003cli\u003eEnable 0 → 1, ready for PWM = Max. 100 µs\u003c\/li\u003e\n\u003cli\u003eQuantity = 4 (2 per axis)\u003c\/li\u003e\n\u003cli\u003eCircuit = Sink\u003c\/li\u003e\n\u003cli\u003eInput current at nominal voltage = Approx. 30 mA\u003c\/li\u003e\n\u003cli\u003eModulation compared to ground potential = Max. ±38 V\u003c\/li\u003e\n\u003cli\u003eOSSD signal connections = Permitted Max. test pulse length: 500 µs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"Never Used Surplus","offer_id":70984810135805,"sku":"8BVI0055HCD0-0001","price":13953.21,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/8BVI0055HCD0-0001.jpg?v=1785722890"},{"product_id":"8bvi0055hwdo-000-1","title":"B\u0026R 8BVI0055HWDO-000-1 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e To Confirm\u003c\/p\u003e\n\u003cp\u003eTo Confirm.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eTo Confirm\u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160961962237,"sku":"8BVI0055HWDO-000-1","price":6251.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/8BVI0055HWDO-000-1.jpg?v=1785723248"},{"product_id":"8bvi0028hwss-000-1","title":"B\u0026R 8BVI0028HWSS-000-1 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Motion control \u0026gt; ACOPOSmulti \u0026gt; Inverter modules, SafeMOTION (single-axis modules) \u0026gt; Wall mounting\u003c\/p\u003e\n\u003cp\u003eClearly structured, straightforward implementation via network-based safety technology Modular expandability through virtual wiring Immediate triggering of safety function due to short cycle times Easy implementation with transparent control and status information, even in the standard application Compact design ACOPOSmulti SafeMOTION EnDat 2.2 inverter module, 3.8 A, AS, wall mounting.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupport\u003c\/li\u003e\n\u003cli\u003eDynamic node allocation (DNA) = Yes\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = Evaluation ongoing\u003c\/li\u003e\n\u003cli\u003eFunctional safety = Yes (openSAFETY)\u003c\/li\u003e\n\u003cli\u003eUL = cULus E225616 Power conversion equipment\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0xAA12\u003c\/li\u003e\n\u003cli\u003eCooling and mounting type = Wall mounting\u003c\/li\u003e\n\u003cli\u003eSlots for plug-in modules = 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDC bus connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage\u003c\/li\u003e\n\u003cli\u003eNominal = 750 VDC\u003c\/li\u003e\n\u003cli\u003ePower dissipation depending on switching frequency\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz = [0.6 * I M ² + 1.3 * I M + 60] W\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz = [0.97 * I M ² + 0.5 * I M + 110] W\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 20 kHz = [1.7 * I M ² - 0.7 * I M + 225] W\u003c\/li\u003e\n\u003cli\u003eContinuous power consumption = 2.87 kW\u003c\/li\u003e\n\u003cli\u003eDC bus capacitance = 165 µF\u003c\/li\u003e\n\u003cli\u003eVariant = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput voltage = 25 VDC ±1.6%\u003c\/li\u003e\n\u003cli\u003eInput capacitance = 23.5 µF\u003c\/li\u003e\n\u003cli\u003eMax. power consumption = 18 W + P SMC1 + P SLOT2 + P 24 V Out + P HoldingBrake\u003c\/li\u003e\n\u003cli\u003eVariant = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC output\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput voltage\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 260 to 315 VDC = 25 VDC * (U DC \/315)\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 315 to 800 VDC = 24 VDC ±6%\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eFuse protection = 250 mA (slow-blow) electronic, automatic reset\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMotor connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReduction of continuous current depending on switching frequency\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz = No reduction\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz = No reduction\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 20 kHz = 0.12 A\/K (starting at 33°C)\u003c\/li\u003e\n\u003cli\u003eReduction of continuous current depending on installation elevation\u003c\/li\u003e\n\u003cli\u003eStarting at 500 m above sea level = 0.38 A eff per 1000 m\u003c\/li\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eOverload protection = Yes\u003c\/li\u003e\n\u003cli\u003eShort-circuit and ground fault protection = Yes\u003c\/li\u003e\n\u003cli\u003eVariant\u003c\/li\u003e\n\u003cli\u003eU, V, W, PE = Connector\u003c\/li\u003e\n\u003cli\u003eShield connection = Yes\u003c\/li\u003e\n\u003cli\u003eTerminal connection cross section\u003c\/li\u003e\n\u003cli\u003eFlexible and fine-stranded wires\u003c\/li\u003e\n\u003cli\u003eWith wire end sleeve = 0.25 to 4 mm²\u003c\/li\u003e\n\u003cli\u003eApprobation data\u003c\/li\u003e\n\u003cli\u003eUL\/C-UL-US = 30 to 10\u003c\/li\u003e\n\u003cli\u003eCSA = 28 to 10\u003c\/li\u003e\n\u003cli\u003eMax. motor line length depending on switching frequency\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz = 25 m\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz = 25 m\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 20 kHz = 10 m\u003c\/li\u003e\n\u003cli\u003eQuantity = 1\u003c\/li\u003e\n\u003cli\u003eContinuous power per motor connection = 2.8 kW\u003c\/li\u003e\n\u003cli\u003eContinuous current per motor connection = 3.8 A eff\u003c\/li\u003e\n\u003cli\u003ePeak current = 9.5 A eff\u003c\/li\u003e\n\u003cli\u003eNominal switching frequency = 5 kHz\u003c\/li\u003e\n\u003cli\u003ePossible switching frequencies = 5 \/ 10 \/ 20 kHz\u003c\/li\u003e\n\u003cli\u003eInsulation stress of the connected motor per IEC TS 60034-25:2004 = Limit value curve A\u003c\/li\u003e\n\u003cli\u003eMax. output frequency = 598 Hz\u003c\/li\u003e\n\u003cli\u003eTerminal cable cross section dimension of shield connection = 12 to 22 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMotor holding brake connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eOverload and short-circuit protection = Yes\u003c\/li\u003e\n\u003cli\u003eOpen-circuit monitoring = Yes\u003c\/li\u003e\n\u003cli\u003eUndervoltage monitoring = Yes\u003c\/li\u003e\n\u003cli\u003eQuantity = 1\u003c\/li\u003e\n\u003cli\u003eOutput voltage = 24 VDC +5.8% \/ -0%\u003c\/li\u003e\n\u003cli\u003eContinuous current per connection = 1.1 A\u003c\/li\u003e\n\u003cli\u003eMax. internal resistance = 0.5 Ω\u003c\/li\u003e\n\u003cli\u003eExtinction potential = Approx. 30 V\u003c\/li\u003e\n\u003cli\u003eMax. extinction energy per switching operation = 1.5 Ws\u003c\/li\u003e\n\u003cli\u003eMax. switching frequency = 0.5 Hz\u003c\/li\u003e\n\u003cli\u003eResponse threshold for open-circuit monitoring = Approx. 0.25 A\u003c\/li\u003e\n\u003cli\u003eResponse threshold for undervoltage monitoring = 24 VDC -2% \/ -4%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEncoder interfaces\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eEncoder - ACOPOSmulti = No\u003c\/li\u003e\n\u003cli\u003eEncoder power supply\u003c\/li\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eShort-circuit proof = Yes\u003c\/li\u003e\n\u003cli\u003eOverload-proof = Yes\u003c\/li\u003e\n\u003cli\u003eOutput voltage = Typ. 12.5 V\u003c\/li\u003e\n\u003cli\u003eLoad capacity = 350 mA\u003c\/li\u003e\n\u003cli\u003eSynchronous serial interface\u003c\/li\u003e\n\u003cli\u003eSignal transmission = RS485\u003c\/li\u003e\n\u003cli\u003eData transfer rate = 6.25 Mbit\/s\u003c\/li\u003e\n\u003cli\u003eQuantity = 1\u003c\/li\u003e\n\u003cli\u003eType = EnDat 2.2\u003c\/li\u003e\n\u003cli\u003eConnections = 9-pin female DSUB connector\u003c\/li\u003e\n\u003cli\u003eStatus indicators = UP\/DN LEDs\u003c\/li\u003e\n\u003cli\u003eEncoder monitoring = Yes\u003c\/li\u003e\n\u003cli\u003eMax. encoder cable length = 100 m Depends on the cross section of the power supply wires in the encoder cable\u003c\/li\u003e\n\u003cli\u003eMax. power consumption per encoder interface = P SMC [W] = 19 V * I Encoder [A]\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160962093309,"sku":"8BVI0028HWSS-000-1","price":12910.16,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/8BVI0028HWSS-000-1.jpg?v=1785723234"},{"product_id":"8bvi0028hwdo-000-1","title":"B\u0026R 8BVI0028HWDO-000-1 | B\u0026R","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e To Confirm\u003c\/p\u003e\n\u003cp\u003eTo Confirm.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eTo Confirm\u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"Never Used Surplus","offer_id":70984811086077,"sku":"8BVI0028HWDO-000-1","price":6060.94,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/8BVI0028HWDO-000-1.jpg?v=1785722880"},{"product_id":"8bvi0014hwdo-000-1","title":"B\u0026R 8BVI0014HWDO-000-1 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e To Confirm\u003c\/p\u003e\n\u003cp\u003eTo Confirm.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eTo Confirm\u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160962388221,"sku":"8BVI0014HWDO-000-1","price":5182.32,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/8BVI0014HWDO-000-1.jpg?v=1785723200"},{"product_id":"8bvi0028hws0-000-1","title":"B\u0026R 8BVI0028HWS0-000-1 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Motion control \u0026gt; ACOPOSmulti \u0026gt; Inverter modules (single-axis modules) \u0026gt; Wall mounting\u003c\/p\u003e\n\u003cp\u003eACOPOSmulti inverter module, 3.8 A, AS, wall mounting.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupport\u003c\/li\u003e\n\u003cli\u003eDynamic node allocation (DNA) = Yes\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = Evaluation ongoing\u003c\/li\u003e\n\u003cli\u003eFunctional safety = Yes\u003c\/li\u003e\n\u003cli\u003eUL = cULus E225616 Power conversion equipment\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0x26E0\u003c\/li\u003e\n\u003cli\u003eCooling and mounting type = Wall mounting\u003c\/li\u003e\n\u003cli\u003eSlots for plug-in modules = 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDC bus connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage\u003c\/li\u003e\n\u003cli\u003eNominal = 750 VDC\u003c\/li\u003e\n\u003cli\u003ePower dissipation depending on switching frequency\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz = [0.6 * I M ² + 1.3 * I M + 60] W\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz = [0.97 * I M ² + 0.5 * I M + 110] W\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 20 kHz = [1.7 * I M ² - 0.7 * I M + 225] W\u003c\/li\u003e\n\u003cli\u003eContinuous power consumption = 2.87 kW\u003c\/li\u003e\n\u003cli\u003eDC bus capacitance = 165 µF\u003c\/li\u003e\n\u003cli\u003eExecution = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput voltage = 25 VDC ±1.6%\u003c\/li\u003e\n\u003cli\u003eInput capacitance = 23.5 µF\u003c\/li\u003e\n\u003cli\u003eMax. power consumption = 12 W + P SLOT1 + P SLOT2 + P 24 V Out + P HoldingBrake\u003c\/li\u003e\n\u003cli\u003eExecution = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC output\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput voltage\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 260 to 315 VDC = 25 VDC * (U DC \/315)\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 315 to 800 VDC = 24 VDC ±6%\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eFuse protection = 250 mA (slow-blow) electronic, automatic reset\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMotor connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReduction of continuous current depending on switching frequency\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz = No reduction\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz = No reduction\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 20 kHz = 0.12 A\/K (starting at 33°C)\u003c\/li\u003e\n\u003cli\u003eReduction of continuous current depending on installation elevation\u003c\/li\u003e\n\u003cli\u003eStarting at 500 m above sea level = 0.38 A eff per 1000 m\u003c\/li\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eOverload protection = Yes\u003c\/li\u003e\n\u003cli\u003eShort-circuit and ground fault protection = Yes\u003c\/li\u003e\n\u003cli\u003eExecution\u003c\/li\u003e\n\u003cli\u003eU, V, W, PE = Connector\u003c\/li\u003e\n\u003cli\u003eShield connection = Yes\u003c\/li\u003e\n\u003cli\u003eTerminal connection cross section\u003c\/li\u003e\n\u003cli\u003eFlexible and fine-stranded wires\u003c\/li\u003e\n\u003cli\u003eWith wire end sleeve = 0.25 to 6 mm²\u003c\/li\u003e\n\u003cli\u003eApprobation data\u003c\/li\u003e\n\u003cli\u003eUL\/C-UL-US = 30 to 10 AWG\u003c\/li\u003e\n\u003cli\u003eCSA = 28 to 10 AWG\u003c\/li\u003e\n\u003cli\u003eMax. motor line length depending on switching frequency\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz = 25 m\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz = 25 m\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 20 kHz = 10 m\u003c\/li\u003e\n\u003cli\u003eQuantity = 1\u003c\/li\u003e\n\u003cli\u003eContinuous power per motor connection = 2.8 kW\u003c\/li\u003e\n\u003cli\u003eContinuous current per motor connection = 3.8 A eff\u003c\/li\u003e\n\u003cli\u003ePeak current = 9.5 A eff\u003c\/li\u003e\n\u003cli\u003eNominal switching frequency = 5 kHz\u003c\/li\u003e\n\u003cli\u003ePossible switching frequencies = 5 \/ 10 \/ 20 kHz\u003c\/li\u003e\n\u003cli\u003eInsulation stress of the connected motor per IEC TS 60034-25:2004 = Limit value curve A\u003c\/li\u003e\n\u003cli\u003eMax. output frequency = 598 Hz\u003c\/li\u003e\n\u003cli\u003eTerminal cable cross section dimension of shield connection = 12 to 22 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMotor holding brake connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eOverload and short-circuit protection = Yes\u003c\/li\u003e\n\u003cli\u003eOpen-circuit monitoring = Yes\u003c\/li\u003e\n\u003cli\u003eUndervoltage monitoring = Yes\u003c\/li\u003e\n\u003cli\u003eQuantity = 1\u003c\/li\u003e\n\u003cli\u003eOutput voltage = 24 VDC +5.8% \/ -0%\u003c\/li\u003e\n\u003cli\u003eContinuous current per connection = 1.1 A\u003c\/li\u003e\n\u003cli\u003eMax. internal resistance = 0.5 Ω\u003c\/li\u003e\n\u003cli\u003eExtinction potential = Approx. 30 V\u003c\/li\u003e\n\u003cli\u003eMax. extinction energy per switching operation = 1.5 Ws\u003c\/li\u003e\n\u003cli\u003eMax. switching frequency = 0.5 Hz\u003c\/li\u003e\n\u003cli\u003eResponse threshold for open-circuit monitoring = Approx. 0.25 A\u003c\/li\u003e\n\u003cli\u003eResponse threshold for undervoltage monitoring = 24 VDC +0% \/ -4%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnable inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eInput - Inverter module = Yes\u003c\/li\u003e\n\u003cli\u003eInput - Input = Yes\u003c\/li\u003e\n\u003cli\u003eInput voltage\u003c\/li\u003e\n\u003cli\u003eNominal = 24 VDC\u003c\/li\u003e\n\u003cli\u003eMaximum = 30 VDC\u003c\/li\u003e\n\u003cli\u003eSwitching threshold\u003c\/li\u003e\n\u003cli\u003eLow = \u0026lt;5 V\u003c\/li\u003e\n\u003cli\u003eHigh = \u0026gt;15 V\u003c\/li\u003e\n\u003cli\u003eSwitching delay at nominal input voltage\u003c\/li\u003e\n\u003cli\u003eEnable 1 → 0, PWM off = Max. 20.5 ms\u003c\/li\u003e\n\u003cli\u003eEnable 0 → 1, ready for PWM = Max. 100 µs\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eCircuit = Sink\u003c\/li\u003e\n\u003cli\u003eInput current at nominal voltage = Approx. 30 mA\u003c\/li\u003e\n\u003cli\u003eModulation compared to ground potential = Max. ±38 V\u003c\/li\u003e\n\u003cli\u003eOSSD signal connections = Permitted Max. test pulse length: 500 µs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrigger inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eInput - Inverter module = Yes\u003c\/li\u003e\n\u003cli\u003eInput - Input = Yes\u003c\/li\u003e\n\u003cli\u003eInput voltage\u003c\/li\u003e\n\u003cli\u003eNominal = 24 VDC\u003c\/li\u003e\n\u003cli\u003eMaximum = 30 VDC\u003c\/li\u003e\n\u003cli\u003eSwitching threshold\u003c\/li\u003e\n\u003cli\u003eLow = \u0026lt;5 V\u003c\/li\u003e\n\u003cli\u003eHigh = \u0026gt;15 V\u003c\/li\u003e\n\u003cli\u003eSwitching delay\u003c\/li\u003e\n\u003cli\u003eRising edge = 52 µs ±0.5 µs (digitally filtered)\u003c\/li\u003e\n\u003cli\u003eFalling edge = 53 µs ±0.5 µs (digitally filtered)\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eCircuit = Sink\u003c\/li\u003e\n\u003cli\u003eInput current at nominal voltage = Approx. 10 mA\u003c\/li\u003e\n\u003cli\u003eModulation compared to ground potential = Max. ±38 V\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160962453757,"sku":"8BVI0028HWS0-000-1","price":4892.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/8BVI0028HWS0-000-1.jpg?v=1785723215"},{"product_id":"8bvi0014hws0-000-1","title":"B\u0026R 8BVI0014HWS0-000-1 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Motion control \u0026gt; ACOPOSmulti \u0026gt; Inverter modules (single-axis modules) \u0026gt; Wall mounting\u003c\/p\u003e\n\u003cp\u003eIntegrated uncontrolled standstill and safe stop Integrated connection for motor holding brake and temperature sensor 2 slots for ACOPOSmulti plug-in modules ACOPOSmulti inverter module, 1.9 A, AS, wall mounting.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupport\u003c\/li\u003e\n\u003cli\u003eDynamic node allocation (DNA) = Yes\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = Evaluation ongoing\u003c\/li\u003e\n\u003cli\u003eFunctional safety = Yes\u003c\/li\u003e\n\u003cli\u003eUL = cULus E225616 Power conversion equipment\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0x26DE\u003c\/li\u003e\n\u003cli\u003eCooling and mounting type = Wall mounting\u003c\/li\u003e\n\u003cli\u003eSlots for plug-in modules = 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDC bus connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage\u003c\/li\u003e\n\u003cli\u003eNominal = 750 VDC\u003c\/li\u003e\n\u003cli\u003ePower dissipation depending on switching frequency\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz = [0.6 * I M ² + 1.3 * I M + 60] W\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz = [0.97 * I M ² + 0.5 * I M + 110] W\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 20 kHz = [1.7 * I M ² - 0.7 * I M + 225] W\u003c\/li\u003e\n\u003cli\u003eContinuous power consumption = 1.46 kW\u003c\/li\u003e\n\u003cli\u003eDC bus capacitance = 165 µF\u003c\/li\u003e\n\u003cli\u003eVariant = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput voltage = 25 VDC ±1.6%\u003c\/li\u003e\n\u003cli\u003eInput capacitance = 23.5 µF\u003c\/li\u003e\n\u003cli\u003eMax. power consumption = 12 W + P SLOT1 + P SLOT2 + P 24 V Out + P HoldingBrake\u003c\/li\u003e\n\u003cli\u003eVariant = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC output\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput voltage\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 260 to 315 VDC = 25 VDC * (U DC \/315)\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 315 to 800 VDC = 24 VDC ±6%\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eFuse protection = 250 mA (slow-blow) electronic, automatic reset\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMotor connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReduction of continuous current depending on switching frequency\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz = No reduction\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz = No reduction\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 20 kHz = 0.11 A\/K (starting at 33°C)\u003c\/li\u003e\n\u003cli\u003eReduction of continuous current depending on installation elevation\u003c\/li\u003e\n\u003cli\u003eStarting at 500 m above sea level = 0.19 A eff per 1000 m\u003c\/li\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eOverload protection = Yes\u003c\/li\u003e\n\u003cli\u003eShort-circuit and ground fault protection = Yes\u003c\/li\u003e\n\u003cli\u003eVariant\u003c\/li\u003e\n\u003cli\u003eU, V, W, PE = Connector\u003c\/li\u003e\n\u003cli\u003eShield connection = Yes\u003c\/li\u003e\n\u003cli\u003eTerminal connection cross section\u003c\/li\u003e\n\u003cli\u003eFlexible and fine-stranded wires\u003c\/li\u003e\n\u003cli\u003eWith wire end sleeve = 0.25 to 6 mm²\u003c\/li\u003e\n\u003cli\u003eApprobation data\u003c\/li\u003e\n\u003cli\u003eUL\/C-UL-US = 30 to 10 AWG\u003c\/li\u003e\n\u003cli\u003eCSA = 28 to 10 AWG\u003c\/li\u003e\n\u003cli\u003eMax. motor line length depending on switching frequency\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz = 25 m\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz = 25 m\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 20 kHz = 10 m\u003c\/li\u003e\n\u003cli\u003eQuantity = 1\u003c\/li\u003e\n\u003cli\u003eContinuous power per motor connection = 1.4 kW\u003c\/li\u003e\n\u003cli\u003eContinuous current per motor connection = 1.9 A eff\u003c\/li\u003e\n\u003cli\u003ePeak current = 4.7 A eff\u003c\/li\u003e\n\u003cli\u003eNominal switching frequency = 5 kHz\u003c\/li\u003e\n\u003cli\u003ePossible switching frequencies = 5 \/ 10 \/ 20 kHz\u003c\/li\u003e\n\u003cli\u003eInsulation stress of the connected motor per IEC TS 60034-25:2004 = Limit value curve A\u003c\/li\u003e\n\u003cli\u003eMax. output frequency = 598 Hz\u003c\/li\u003e\n\u003cli\u003eTerminal cable cross section dimension of shield connection = 12 to 22 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMotor holding brake connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eOverload and short-circuit protection = Yes\u003c\/li\u003e\n\u003cli\u003eOpen-circuit monitoring = Yes\u003c\/li\u003e\n\u003cli\u003eUndervoltage monitoring = Yes\u003c\/li\u003e\n\u003cli\u003eQuantity = 1\u003c\/li\u003e\n\u003cli\u003eOutput voltage = 24 VDC +5.8% \/ -0%\u003c\/li\u003e\n\u003cli\u003eContinuous current per connection = 1.1 A\u003c\/li\u003e\n\u003cli\u003eMax. internal resistance = 0.5 Ω\u003c\/li\u003e\n\u003cli\u003eExtinction potential = Approx. 30 V\u003c\/li\u003e\n\u003cli\u003eMax. extinction energy per switching operation = 1.5 Ws\u003c\/li\u003e\n\u003cli\u003eMax. switching frequency = 0.5 Hz\u003c\/li\u003e\n\u003cli\u003eResponse threshold for open-circuit monitoring = Approx. 0.25 A\u003c\/li\u003e\n\u003cli\u003eResponse threshold for undervoltage monitoring = 24 VDC +0% \/ -4%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnable inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eInput - Inverter module = Yes\u003c\/li\u003e\n\u003cli\u003eInput - Input = Yes\u003c\/li\u003e\n\u003cli\u003eInput voltage\u003c\/li\u003e\n\u003cli\u003eNominal = 24 VDC\u003c\/li\u003e\n\u003cli\u003eMaximum = 30 VDC\u003c\/li\u003e\n\u003cli\u003eSwitching threshold\u003c\/li\u003e\n\u003cli\u003eLow = \u0026lt;5 V\u003c\/li\u003e\n\u003cli\u003eHigh = \u0026gt;15 V\u003c\/li\u003e\n\u003cli\u003eSwitching delay at nominal input voltage\u003c\/li\u003e\n\u003cli\u003eEnable 1 → 0, PWM off = Max. 20.5 ms\u003c\/li\u003e\n\u003cli\u003eEnable 0 → 1, ready for PWM = Max. 100 µs\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eCircuit = Sink\u003c\/li\u003e\n\u003cli\u003eInput current at nominal voltage = Approx. 30 mA\u003c\/li\u003e\n\u003cli\u003eModulation compared to ground potential = Max. ±38 V\u003c\/li\u003e\n\u003cli\u003eOSSD signal connections = Permitted Max. test pulse length: 500 µs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrigger inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eInput - Inverter module = Yes\u003c\/li\u003e\n\u003cli\u003eInput - Input = Yes\u003c\/li\u003e\n\u003cli\u003eInput voltage\u003c\/li\u003e\n\u003cli\u003eNominal = 24 VDC\u003c\/li\u003e\n\u003cli\u003eMaximum = 30 VDC\u003c\/li\u003e\n\u003cli\u003eSwitching threshold\u003c\/li\u003e\n\u003cli\u003eLow = \u0026lt;5 V\u003c\/li\u003e\n\u003cli\u003eHigh = \u0026gt;15 V\u003c\/li\u003e\n\u003cli\u003eSwitching delay\u003c\/li\u003e\n\u003cli\u003eRising edge = 52 µs ±0.5 µs (digitally filtered)\u003c\/li\u003e\n\u003cli\u003eFalling edge = 53 µs ±0.5 µs (digitally filtered)\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eCircuit = Sink\u003c\/li\u003e\n\u003cli\u003eInput current at nominal voltage = Approx. 10 mA\u003c\/li\u003e\n\u003cli\u003eModulation compared to ground potential = Max. ±38 V\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160962519293,"sku":"8BVI0014HWS0-000-1","price":5568.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/8BVI0014HWS0-000-1.jpg?v=1785723208"},{"product_id":"8bvi0028hwd0-0001","title":"B\u0026R 8BVI0028HWD0-0001 | B\u0026R","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Motion control \u0026gt; ACOPOSmulti \u0026gt; Inverter modules (two-axis modules) \u0026gt; Wall mounting\u003c\/p\u003e\n\u003cp\u003eIntegrated uncontrolled standstill and safe stop Integrated connection for motor holding brake and temperature sensor 2 slots for ACOPOSmulti plug-in modules Two fully independent power inverters in one inverter module contained in 2-axis modules ACOPOSmulti inverter module, 3.8 A, AS, wall mounting, 2 axes.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupport\u003c\/li\u003e\n\u003cli\u003eDynamic node allocation (DNA) = Yes\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = Evaluation ongoing\u003c\/li\u003e\n\u003cli\u003eFunctional safety = Yes\u003c\/li\u003e\n\u003cli\u003eUL = cULus E225616 Power conversion equipment\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0x26E1\u003c\/li\u003e\n\u003cli\u003eCooling and mounting type = Wall mounting\u003c\/li\u003e\n\u003cli\u003eSlots for plug-in modules = 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDC bus connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage\u003c\/li\u003e\n\u003cli\u003eNominal = 750 VDC\u003c\/li\u003e\n\u003cli\u003ePower dissipation depending on switching frequency\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz = [1.2 * I M ² + 2.62 * I M + 100] W\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz = [2.56 * I M ² + 2.8 * I M + 200] W\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 20 kHz = [6 * I M ² - 9.4 * I M + 430] W\u003c\/li\u003e\n\u003cli\u003eContinuous power consumption = 5.73 kW\u003c\/li\u003e\n\u003cli\u003eDC bus capacitance = 165 µF\u003c\/li\u003e\n\u003cli\u003eVariant = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput voltage = 25 VDC ±1.6%\u003c\/li\u003e\n\u003cli\u003eInput capacitance = 23.5 µF\u003c\/li\u003e\n\u003cli\u003eMax. power consumption = 16 W + P SLOT1 + P SLOT2 + P 24 V Out + P HoldingBrake(s)\u003c\/li\u003e\n\u003cli\u003eVariant = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC output\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput voltage\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 260 to 315 VDC = 25 VDC * (U DC \/315)\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 315 to 800 VDC = 24 VDC ±6%\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eFuse protection = 250 mA (slow-blow) electronic, automatic reset\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMotor connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReduction of continuous current depending on switching frequency\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz = No reduction\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz = No reduction\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 20 kHz = 0.12 A\/K (starting at 13°C)\u003c\/li\u003e\n\u003cli\u003eReduction of continuous current depending on installation elevation\u003c\/li\u003e\n\u003cli\u003eStarting at 500 m above sea level = 0.38 A eff per 1000 m\u003c\/li\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eOverload protection = Yes\u003c\/li\u003e\n\u003cli\u003eShort-circuit and ground fault protection = Yes\u003c\/li\u003e\n\u003cli\u003eVariant\u003c\/li\u003e\n\u003cli\u003eU, V, W, PE = Connector\u003c\/li\u003e\n\u003cli\u003eShield connection = Yes\u003c\/li\u003e\n\u003cli\u003eTerminal connection cross section\u003c\/li\u003e\n\u003cli\u003eFlexible and fine-stranded wires\u003c\/li\u003e\n\u003cli\u003eWith wire end sleeve = 0.25 to 6 mm²\u003c\/li\u003e\n\u003cli\u003eApprobation data\u003c\/li\u003e\n\u003cli\u003eUL\/C-UL-US = 30 to 10 AWG\u003c\/li\u003e\n\u003cli\u003eCSA = 28 to 10 AWG\u003c\/li\u003e\n\u003cli\u003eMax. motor line length depending on switching frequency\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz = 25 m\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz = 25 m\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 20 kHz = 10 m\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eContinuous power per motor connection = 2.8 kW\u003c\/li\u003e\n\u003cli\u003eContinuous current per motor connection = 3.8 A eff\u003c\/li\u003e\n\u003cli\u003ePeak current per motor connection = 9.5 A eff\u003c\/li\u003e\n\u003cli\u003eNominal switching frequency = 5 kHz\u003c\/li\u003e\n\u003cli\u003ePossible switching frequencies = 5 \/ 10 \/ 20 kHz\u003c\/li\u003e\n\u003cli\u003eInsulation stress of the connected motor per IEC TS 60034-25:2004 = Limit value curve A\u003c\/li\u003e\n\u003cli\u003eMax. output frequency = 598 Hz\u003c\/li\u003e\n\u003cli\u003eTerminal cable cross section dimension of shield connection = 12 to 22 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMotor holding brake connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eOverload and short-circuit protection = Yes\u003c\/li\u003e\n\u003cli\u003eOpen-circuit monitoring = Yes\u003c\/li\u003e\n\u003cli\u003eUndervoltage monitoring = Yes\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eOutput voltage = 24 VDC +5.8% \/ -0%\u003c\/li\u003e\n\u003cli\u003eContinuous current per connection = 1.1 A\u003c\/li\u003e\n\u003cli\u003eMax. internal resistance = 0.5 Ω\u003c\/li\u003e\n\u003cli\u003eExtinction potential = Approx. 30 V\u003c\/li\u003e\n\u003cli\u003eMax. extinction energy per switching operation = 1.5 Ws\u003c\/li\u003e\n\u003cli\u003eMax. switching frequency = 0.5 Hz\u003c\/li\u003e\n\u003cli\u003eResponse threshold for open-circuit monitoring = Approx. 0.25 A\u003c\/li\u003e\n\u003cli\u003eResponse threshold for undervoltage monitoring = 24 VDC +0% \/ -4%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnable inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eInput - Inverter module = Yes\u003c\/li\u003e\n\u003cli\u003eInput - Input = Yes\u003c\/li\u003e\n\u003cli\u003eInput voltage\u003c\/li\u003e\n\u003cli\u003eNominal = 24 VDC\u003c\/li\u003e\n\u003cli\u003eMaximum = 30 VDC\u003c\/li\u003e\n\u003cli\u003eSwitching threshold\u003c\/li\u003e\n\u003cli\u003eLow = \u0026lt;5 V\u003c\/li\u003e\n\u003cli\u003eHigh = \u0026gt;15 V\u003c\/li\u003e\n\u003cli\u003eSwitching delay at nominal input voltage\u003c\/li\u003e\n\u003cli\u003eEnable 1 → 0, PWM off = Max. 20.5 ms\u003c\/li\u003e\n\u003cli\u003eEnable 0 → 1, ready for PWM = Max. 100 µs\u003c\/li\u003e\n\u003cli\u003eQuantity = 4 (2 per axis)\u003c\/li\u003e\n\u003cli\u003eCircuit = Sink\u003c\/li\u003e\n\u003cli\u003eInput current at nominal voltage = Approx. 30 mA\u003c\/li\u003e\n\u003cli\u003eModulation compared to ground potential = Max. ±38 V\u003c\/li\u003e\n\u003cli\u003eOSSD signal connections = Permitted Max. test pulse length: 500 µs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrigger inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eInput - Inverter module = Yes\u003c\/li\u003e\n\u003cli\u003eInput - Input = Yes\u003c\/li\u003e\n\u003cli\u003eInput voltage\u003c\/li\u003e\n\u003cli\u003eNominal = 24 VDC\u003c\/li\u003e\n\u003cli\u003eMaximum = 30 VDC\u003c\/li\u003e\n\u003cli\u003eSwitching threshold\u003c\/li\u003e\n\u003cli\u003eLow = \u0026lt;5 V\u003c\/li\u003e\n\u003cli\u003eHigh = \u0026gt;15 V\u003c\/li\u003e\n\u003cli\u003eSwitching delay\u003c\/li\u003e\n\u003cli\u003eRising edge = 52 µs ±0.5 µs (digitally filtered)\u003c\/li\u003e\n\u003cli\u003eFalling edge = 53 µs ±0.5 µs (digitally filtered)\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eCircuit = Sink\u003c\/li\u003e\n\u003cli\u003eInput current at nominal voltage = Approx. 10 mA\u003c\/li\u003e\n\u003cli\u003eModulation compared to ground potential = Max. ±38 V\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"Never Used Surplus","offer_id":70984812560637,"sku":"8BVI0028HWD0-0001","price":10944.64,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/8BVI0028HWD0-0001.jpg?v=1785722872"},{"product_id":"8bve0500hc00-000-1","title":"B\u0026R 8BVE0500HC00-000-1 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Motion control \u0026gt; ACOPOSmulti \u0026gt; Expansion modules \u0026gt; Cold plate or feed-through mounting\u003c\/p\u003e\n\u003cp\u003eFor distributing the DC bus power supply and 24 VDC auxiliary supply to multiple mounting plates For setting up decentralized units in the ACOPOSmulti drive system Output for overload protection ACOPOSmulti expansion module 40 A, AS, cold plate or pass-through mounting.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = Not applicable\u003c\/li\u003e\n\u003cli\u003eUL = cULus E225616 Power conversion equipment\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eCooling and mounting type = Cold plate or pass-through mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDC bus connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage\u003c\/li\u003e\n\u003cli\u003eNominal = 750 VDC\u003c\/li\u003e\n\u003cli\u003eContinuous power depending on fuse\u003c\/li\u003e\n\u003cli\u003e10 A = 6 kW\u003c\/li\u003e\n\u003cli\u003e20 A = 12 kW\u003c\/li\u003e\n\u003cli\u003e50 A = 30 kW\u003c\/li\u003e\n\u003cli\u003eContinuous current depending on fuse\u003c\/li\u003e\n\u003cli\u003e10 A = 8 A eff\u003c\/li\u003e\n\u003cli\u003e20 A = 16 A eff\u003c\/li\u003e\n\u003cli\u003e50 A = 40 A eff\u003c\/li\u003e\n\u003cli\u003eReduction of continuous power depending on installation elevation\u003c\/li\u003e\n\u003cli\u003eStarting at 500 m above sea level = 10% per 1000 m\u003c\/li\u003e\n\u003cli\u003ePeak current depending on fuse\u003c\/li\u003e\n\u003cli\u003e10 A = 20 A\u003c\/li\u003e\n\u003cli\u003e20 A = 40 A\u003c\/li\u003e\n\u003cli\u003e50 A = 100 A\u003c\/li\u003e\n\u003cli\u003eReduction of continuous power at ambient temperatures starting at 40°C = 1.25% per °Kelvin\u003c\/li\u003e\n\u003cli\u003eReduction of continuous power depending on cooling method = No reduction\u003c\/li\u003e\n\u003cli\u003ePower dissipation with continuous power = 200 W\u003c\/li\u003e\n\u003cli\u003eVariant = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous power depending on fuse\u003c\/li\u003e\n\u003cli\u003e12 A = 240 W\u003c\/li\u003e\n\u003cli\u003e20 A = 400 W\u003c\/li\u003e\n\u003cli\u003e30 A = 600 W\u003c\/li\u003e\n\u003cli\u003eInput voltage = 25 VDC ±1.6%\u003c\/li\u003e\n\u003cli\u003eMax. power consumption = 5 W\u003c\/li\u003e\n\u003cli\u003eReduction of continuous power at ambient temperatures starting at 40°C = 1.25% per °Kelvin\u003c\/li\u003e\n\u003cli\u003eVariant = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDC bus cable outlet\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFuse protection\u003c\/li\u003e\n\u003cli\u003eType = 2x melting fuse ø 14 x 51 mm\u003c\/li\u003e\n\u003cli\u003eTripping characteristic = Ultra fast-acting\u003c\/li\u003e\n\u003cli\u003eRated current = 10 \/ 20 \/ 25 \/ 50 A\u003c\/li\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eFuse-dependent overload protection\u003c\/li\u003e\n\u003cli\u003e10 A = No (overload indicated via LED, dry alarm contacts present)\u003c\/li\u003e\n\u003cli\u003e20 A = No (overload indicated via LED, dry alarm contacts present)\u003c\/li\u003e\n\u003cli\u003e50 A = No (overload indicated via LED, dry alarm contacts present)\u003c\/li\u003e\n\u003cli\u003eShort-circuit and ground fault protection = Yes\u003c\/li\u003e\n\u003cli\u003eVariant\u003c\/li\u003e\n\u003cli\u003eDC+, DC-, PE = Connector\u003c\/li\u003e\n\u003cli\u003eShield connection = Yes\u003c\/li\u003e\n\u003cli\u003eTerminal connection cross section\u003c\/li\u003e\n\u003cli\u003eFlexible and fine-stranded wires\u003c\/li\u003e\n\u003cli\u003eWith wire end sleeve = 0.5 to 16 mm²\u003c\/li\u003e\n\u003cli\u003eApprobation data\u003c\/li\u003e\n\u003cli\u003eUL\/C-UL-US = 20 to 6 AWG\u003c\/li\u003e\n\u003cli\u003eCSA = 20 to 6 AWG\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eMax. line length between two expansion modules = 5 m\u003c\/li\u003e\n\u003cli\u003eTerminal cable cross section dimension of shield connection = 12 to 22 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC auxiliary supply cable outlet\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput voltage\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 260 to 315 VDC = 25 VDC * (DC bus voltage \/ 315)\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 315 to 800 VDC = 24 VDC ±6%\u003c\/li\u003e\n\u003cli\u003eFuse protection\u003c\/li\u003e\n\u003cli\u003eType = Melting fuse ø 10 x 38 mm\u003c\/li\u003e\n\u003cli\u003eTripping characteristic = Fast-acting\u003c\/li\u003e\n\u003cli\u003eRated current = 12 \/ 30 A\u003c\/li\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eOverload protection = Yes\u003c\/li\u003e\n\u003cli\u003eShort-circuit proof = Yes\u003c\/li\u003e\n\u003cli\u003eVariant\u003c\/li\u003e\n\u003cli\u003e24 VDC, COM = Connector\u003c\/li\u003e\n\u003cli\u003eShield connection = No\u003c\/li\u003e\n\u003cli\u003eTerminal connection cross section\u003c\/li\u003e\n\u003cli\u003eFlexible and fine-stranded wires\u003c\/li\u003e\n\u003cli\u003eWith wire end sleeve = 0.25 to 6 mm²\u003c\/li\u003e\n\u003cli\u003eApprobation data\u003c\/li\u003e\n\u003cli\u003eUL\/C-UL-US = 22 to 10 AWG\u003c\/li\u003e\n\u003cli\u003eCSA = 22 to 10 AWG\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eMax. line length between two expansion modules = 5 m\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAlarm contacts\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eType\u003c\/li\u003e\n\u003cli\u003eAlarm contact 1 = Normally closed contact\u003c\/li\u003e\n\u003cli\u003eAlarm contact 2 = Normally open contact\u003c\/li\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eAlarm contact - ACOPOSmulti module = Yes\u003c\/li\u003e\n\u003cli\u003eAlarm contact - Alarm contact = Yes\u003c\/li\u003e\n\u003cli\u003eProtection\u003c\/li\u003e\n\u003cli\u003eOverload-proof = No\u003c\/li\u003e\n\u003cli\u003eShort-circuit proof = No\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eNominal voltage = 30 VDC\u003c\/li\u003e\n\u003cli\u003eMaximum current = 1 A\u003c\/li\u003e\n\u003cli\u003eSwitching delay = 3 ms\u003c\/li\u003e\n\u003cli\u003eMax. number of switching cycles = 100,000\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperating conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePermissible mounting orientations\u003c\/li\u003e\n\u003cli\u003eHanging vertically = Yes\u003c\/li\u003e\n\u003cli\u003eHorizontal, face up = Yes\u003c\/li\u003e\n\u003cli\u003eStanding horizontally = No\u003c\/li\u003e\n\u003cli\u003eInstallation elevation above sea level\u003c\/li\u003e\n\u003cli\u003eNominal = 0 to 500 m\u003c\/li\u003e\n\u003cli\u003eMaximum = 4000 m\u003c\/li\u003e\n\u003cli\u003ePollution degree per EN 61800-5-1 = 2 (non-conductive pollution)\u003c\/li\u003e\n\u003cli\u003eOvervoltage category per EN 61800-5-1 = III\u003c\/li\u003e\n\u003cli\u003eDegree of protection per EN 60529 = IP20\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature\u003c\/li\u003e\n\u003cli\u003eOperation\u003c\/li\u003e\n\u003cli\u003eNominal = 5 to 40°C\u003c\/li\u003e\n\u003cli\u003eMaximum = 55°C\u003c\/li\u003e\n\u003cli\u003eStorage = -25 to 55°C\u003c\/li\u003e\n\u003cli\u003eTransport = -25 to 70°C\u003c\/li\u003e\n\u003cli\u003eRelative humidity\u003c\/li\u003e\n\u003cli\u003eOperation = 5 to 85%\u003c\/li\u003e\n\u003cli\u003eStorage = 5 to 95%\u003c\/li\u003e\n\u003cli\u003eTransport = Max. 95% at 40°C\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160963141885,"sku":"8BVE0500HC00-000-1","price":6013.35,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/8BVE0500HC00-000-1.jpg?v=1785723171"},{"product_id":"8bvi0014hwd0-000-1","title":"B\u0026R 8BVI0014HWD0-000-1 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Motion control \u0026gt; ACOPOSmulti \u0026gt; Inverter modules (two-axis modules) \u0026gt; Wall mounting\u003c\/p\u003e\n\u003cp\u003eUncontrolled stops and safe stop integrated Integrated connection for motor motor holding brake and temperature sensor 2 slots for ACOPOSmulti plug-in modules Double axis modules contain two complete standalone inverters in an inverter module ACOPOSmulti inverter module, 1.9 A, AS, wall mounting, 2 axes.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupport\u003c\/li\u003e\n\u003cli\u003eDynamic node allocation (DNA) = Yes\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = Evaluation ongoing\u003c\/li\u003e\n\u003cli\u003eFunctional safety = Yes\u003c\/li\u003e\n\u003cli\u003eUL = cULus E225616 Power conversion equipment\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0x26DF\u003c\/li\u003e\n\u003cli\u003eCooling and mounting type = Wall mounting\u003c\/li\u003e\n\u003cli\u003eSlots for plug-in modules = 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDC bus connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage\u003c\/li\u003e\n\u003cli\u003eNominal = 750 VDC\u003c\/li\u003e\n\u003cli\u003ePower dissipation depending on switching frequency\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz = [1.2 * I M ² + 2.62 * I M + 100] W\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz = [2.56 * I M ² + 2.8 * I M + 200] W\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 20 kHz = [6 * I M ² - 9.4 * I M + 430] W\u003c\/li\u003e\n\u003cli\u003eContinuous power consumption = 2.91 kW\u003c\/li\u003e\n\u003cli\u003eDC bus capacitance = 165 µF\u003c\/li\u003e\n\u003cli\u003eVariant = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput voltage = 25 VDC ±1.6%\u003c\/li\u003e\n\u003cli\u003eInput capacitance = 23.5 µF\u003c\/li\u003e\n\u003cli\u003eMax. power consumption = 16 W + P SLOT1 + P SLOT2 + P 24 V Out + P HoldingBrake(s)\u003c\/li\u003e\n\u003cli\u003eVariant = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC output\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput voltage\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 260 to 315 VDC = 25 VDC * (U DC \/315)\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 315 to 800 VDC = 24 VDC ±6%\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eFuse protection = 250 mA (slow-blow) electronic, automatic reset\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMotor connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReduction of continuous current depending on switching frequency\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz = No reduction\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz = No reduction\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 20 kHz = 0.11 A\/K (starting at 15°C)\u003c\/li\u003e\n\u003cli\u003eReduction of continuous current depending on installation elevation\u003c\/li\u003e\n\u003cli\u003eStarting at 500 m above sea level = 0.19 A eff per 1000 m\u003c\/li\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eOverload protection = Yes\u003c\/li\u003e\n\u003cli\u003eShort-circuit and ground fault protection = Yes\u003c\/li\u003e\n\u003cli\u003eVariant\u003c\/li\u003e\n\u003cli\u003eU, V, W, PE = Connector\u003c\/li\u003e\n\u003cli\u003eShield connection = Yes\u003c\/li\u003e\n\u003cli\u003eTerminal connection cross section\u003c\/li\u003e\n\u003cli\u003eFlexible and fine-stranded wires\u003c\/li\u003e\n\u003cli\u003eWith wire end sleeve = 0.25 to 6 mm²\u003c\/li\u003e\n\u003cli\u003eApprobation data\u003c\/li\u003e\n\u003cli\u003eUL\/C-UL-US = 30 to 10 AWG\u003c\/li\u003e\n\u003cli\u003eCSA = 28 to 10 AWG\u003c\/li\u003e\n\u003cli\u003eMax. motor line length depending on switching frequency\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz = 25 m\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz = 25 m\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 20 kHz = 10 m\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eContinuous power per motor connection = 1.4 kW\u003c\/li\u003e\n\u003cli\u003eContinuous current per motor connection = 1.9 A eff\u003c\/li\u003e\n\u003cli\u003ePeak current per motor connection = 4.7 A eff\u003c\/li\u003e\n\u003cli\u003eNominal switching frequency = 5 kHz\u003c\/li\u003e\n\u003cli\u003ePossible switching frequencies = 5 \/ 10 \/ 20 kHz\u003c\/li\u003e\n\u003cli\u003eInsulation stress of the connected motor per IEC TS 60034-25:2004 = Limit value curve A\u003c\/li\u003e\n\u003cli\u003eMax. output frequency = 598 Hz\u003c\/li\u003e\n\u003cli\u003eTerminal cable cross section dimension of shield connection = 12 to 22 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMotor holding brake connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eOverload and short-circuit protection = Yes\u003c\/li\u003e\n\u003cli\u003eOpen-circuit monitoring = Yes\u003c\/li\u003e\n\u003cli\u003eUndervoltage monitoring = Yes\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eOutput voltage = 24 VDC +5.8% \/ -0%\u003c\/li\u003e\n\u003cli\u003eContinuous current per connection = 1.1 A\u003c\/li\u003e\n\u003cli\u003eMax. internal resistance = 0.5 Ω\u003c\/li\u003e\n\u003cli\u003eExtinction potential = Approx. 30 V\u003c\/li\u003e\n\u003cli\u003eMax. extinction energy per switching operation = 1.5 Ws\u003c\/li\u003e\n\u003cli\u003eMax. switching frequency = 0.5 Hz\u003c\/li\u003e\n\u003cli\u003eResponse threshold for open-circuit monitoring = Approx. 0.25 A\u003c\/li\u003e\n\u003cli\u003eResponse threshold for undervoltage monitoring = 24 VDC +0% \/ -4%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnable inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eInput - Inverter module = Yes\u003c\/li\u003e\n\u003cli\u003eInput - Input = Yes\u003c\/li\u003e\n\u003cli\u003eInput voltage\u003c\/li\u003e\n\u003cli\u003eNominal = 24 VDC\u003c\/li\u003e\n\u003cli\u003eMaximum = 30 VDC\u003c\/li\u003e\n\u003cli\u003eSwitching threshold\u003c\/li\u003e\n\u003cli\u003eLow = \u0026lt;5 V\u003c\/li\u003e\n\u003cli\u003eHigh = \u0026gt;15 V\u003c\/li\u003e\n\u003cli\u003eSwitching delay at nominal input voltage\u003c\/li\u003e\n\u003cli\u003eEnable 1 → 0, PWM off = Max. 20.5 ms\u003c\/li\u003e\n\u003cli\u003eEnable 0 → 1, ready for PWM = Max. 100 µs\u003c\/li\u003e\n\u003cli\u003eQuantity = 4 (2 per axis)\u003c\/li\u003e\n\u003cli\u003eCircuit = Sink\u003c\/li\u003e\n\u003cli\u003eInput current at nominal voltage = Approx. 30 mA\u003c\/li\u003e\n\u003cli\u003eModulation compared to ground potential = Max. ±38 V\u003c\/li\u003e\n\u003cli\u003eOSSD signal connections = Permitted Max. test pulse length: 500 µs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTrigger inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eInput - Inverter module = Yes\u003c\/li\u003e\n\u003cli\u003eInput - Input = Yes\u003c\/li\u003e\n\u003cli\u003eInput voltage\u003c\/li\u003e\n\u003cli\u003eNominal = 24 VDC\u003c\/li\u003e\n\u003cli\u003eMaximum = 30 VDC\u003c\/li\u003e\n\u003cli\u003eSwitching threshold\u003c\/li\u003e\n\u003cli\u003eLow = \u0026lt;5 V\u003c\/li\u003e\n\u003cli\u003eHigh = \u0026gt;15 V\u003c\/li\u003e\n\u003cli\u003eSwitching delay\u003c\/li\u003e\n\u003cli\u003eRising edge = 52 µs ±0.5 µs (digitally filtered)\u003c\/li\u003e\n\u003cli\u003eFalling edge = 53 µs ±0.5 µs (digitally filtered)\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eCircuit = Sink\u003c\/li\u003e\n\u003cli\u003eInput current at nominal voltage = Approx. 10 mA\u003c\/li\u003e\n\u003cli\u003eModulation compared to ground potential = Max. ±38 V\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160963305725,"sku":"8BVI0014HWD0-000-1","price":4892.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/8BVI0014HWD0-000-1.jpg?v=1785723187"},{"product_id":"8bvi0014hcd0-000-1","title":"B\u0026R 8BVI0014HCD0-000-1 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Motion control \u0026gt; ACOPOSmulti \u0026gt; Inverter modules (two-axis modules) \u0026gt; Cold plate or feed-through mounting\u003c\/p\u003e\n\u003cp\u003eIntegrated uncontrolled standstill and safe stop Integrated connection for motor holding brake and temperature sensor 2 slots for ACOPOSmulti plug-in modules Two fully independent power inverters in one inverter module contained in 2-axis modules ACOPOSmulti inverter module, 1.9 A, AS, cold plate or pass-through mounting, 2 axes.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupport\u003c\/li\u003e\n\u003cli\u003eDynamic node allocation (DNA) = Yes\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = Evaluation ongoing\u003c\/li\u003e\n\u003cli\u003eFunctional safety = Yes\u003c\/li\u003e\n\u003cli\u003eUL = cULus E225616 Power conversion equipment\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0x253C\u003c\/li\u003e\n\u003cli\u003eCooling and mounting type = Cold plate or pass-through mounting\u003c\/li\u003e\n\u003cli\u003eSlots for plug-in modules = 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDC bus connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage\u003c\/li\u003e\n\u003cli\u003eNominal = 750 VDC\u003c\/li\u003e\n\u003cli\u003ePower dissipation depending on switching frequency\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz = [1.2 * I M ² + 2.62 * I M + 100] W\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz = [2.56 * I M ² + 2.8 * I M + 200] W\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 20 kHz = [6 * I M ² - 9.4 * I M + 430] W\u003c\/li\u003e\n\u003cli\u003eContinuous power consumption = 2.91 kW\u003c\/li\u003e\n\u003cli\u003eDC bus capacitance = 165 µF\u003c\/li\u003e\n\u003cli\u003eVariant = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput voltage = 25 VDC ±1.6%\u003c\/li\u003e\n\u003cli\u003eInput capacitance = 23.5 µF\u003c\/li\u003e\n\u003cli\u003eMax. power consumption = 16 W + P SLOT1 + P SLOT2 + P 24 V Out + P HoldingBrake(s)\u003c\/li\u003e\n\u003cli\u003eVariant = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC output\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput voltage\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 260 to 315 VDC = 25 VDC * (U DC \/315)\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 315 to 800 VDC = 24 VDC ±6%\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eFuse protection = 250 mA (slow-blow) electronic, automatic reset\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMotor connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReduction of continuous current depending on switching frequency and mounting type\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz\u003c\/li\u003e\n\u003cli\u003eCold plate mounting = No reduction\u003c\/li\u003e\n\u003cli\u003ePass-through mounting = No reduction\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 20 kHz\u003c\/li\u003e\n\u003cli\u003eCold plate mounting = 0.13 A\/K (starting at 45°C)\u003c\/li\u003e\n\u003cli\u003ePass-through mounting = 0.14 A\/K (starting at 32°C)\u003c\/li\u003e\n\u003cli\u003eReduction of continuous current depending on installation elevation\u003c\/li\u003e\n\u003cli\u003eStarting at 500 m above sea level = 0.19 A eff per 1000 m\u003c\/li\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eOverload protection = Yes\u003c\/li\u003e\n\u003cli\u003eShort-circuit and ground fault protection = Yes\u003c\/li\u003e\n\u003cli\u003eVariant\u003c\/li\u003e\n\u003cli\u003eU, V, W, PE = Connector\u003c\/li\u003e\n\u003cli\u003eShield connection = Yes\u003c\/li\u003e\n\u003cli\u003eTerminal connection cross section\u003c\/li\u003e\n\u003cli\u003eFlexible and fine-stranded wires\u003c\/li\u003e\n\u003cli\u003eWith wire end sleeve = 0.25 to 6 mm²\u003c\/li\u003e\n\u003cli\u003eApprobation data\u003c\/li\u003e\n\u003cli\u003eUL\/C-UL-US = 30 to 10 AWG\u003c\/li\u003e\n\u003cli\u003eCSA = 28 to 10 AWG\u003c\/li\u003e\n\u003cli\u003eMax. motor line length depending on switching frequency\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 5 kHz = 25 m\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 10 kHz = 25 m\u003c\/li\u003e\n\u003cli\u003eSwitching frequency 20 kHz = 10 m\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eContinuous power per motor connection = 1.4 kW\u003c\/li\u003e\n\u003cli\u003eContinuous current per motor connection = 1.9 A eff\u003c\/li\u003e\n\u003cli\u003ePeak current per motor connection = 4.7 A eff\u003c\/li\u003e\n\u003cli\u003eNominal switching frequency = 5 kHz\u003c\/li\u003e\n\u003cli\u003ePossible switching frequencies = 5 \/ 10 \/ 20 kHz\u003c\/li\u003e\n\u003cli\u003eInsulation stress of the connected motor per IEC TS 60034-25:2004 = Limit value curve A\u003c\/li\u003e\n\u003cli\u003eMax. output frequency = 598 Hz\u003c\/li\u003e\n\u003cli\u003eTerminal cable cross section dimension of shield connection = 12 to 22 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMotor holding brake connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eOverload and short-circuit protection = Yes\u003c\/li\u003e\n\u003cli\u003eOpen-circuit monitoring = Yes\u003c\/li\u003e\n\u003cli\u003eUndervoltage monitoring = Yes\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eOutput voltage = 24 VDC +5.8% \/ -0%\u003c\/li\u003e\n\u003cli\u003eContinuous current per connection = 1.1 A\u003c\/li\u003e\n\u003cli\u003eMax. internal resistance = 0.5 Ω\u003c\/li\u003e\n\u003cli\u003eExtinction potential = Approx. 30 V\u003c\/li\u003e\n\u003cli\u003eMax. extinction energy per switching operation = 1.5 Ws\u003c\/li\u003e\n\u003cli\u003eMax. switching frequency = 0.5 Hz\u003c\/li\u003e\n\u003cli\u003eResponse threshold for open-circuit monitoring = Approx. 0.25 A\u003c\/li\u003e\n\u003cli\u003eResponse threshold for undervoltage monitoring = 24 VDC +0% \/ -4%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnable inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eInput - Inverter module = Yes\u003c\/li\u003e\n\u003cli\u003eInput - Input = Yes\u003c\/li\u003e\n\u003cli\u003eInput voltage\u003c\/li\u003e\n\u003cli\u003eNominal = 24 VDC\u003c\/li\u003e\n\u003cli\u003eMaximum = 30 VDC\u003c\/li\u003e\n\u003cli\u003eSwitching threshold\u003c\/li\u003e\n\u003cli\u003eLow = \u0026lt;5 V\u003c\/li\u003e\n\u003cli\u003eHigh = \u0026gt;15 V\u003c\/li\u003e\n\u003cli\u003eSwitching delay at nominal input voltage\u003c\/li\u003e\n\u003cli\u003eEnable 1 → 0, PWM off = Max. 20.5 ms\u003c\/li\u003e\n\u003cli\u003eEnable 0 → 1, ready for PWM = Max. 100 µs\u003c\/li\u003e\n\u003cli\u003eQuantity = 4 (2 per axis)\u003c\/li\u003e\n\u003cli\u003eCircuit = Sink\u003c\/li\u003e\n\u003cli\u003eInput current at nominal voltage = Approx. 30 mA\u003c\/li\u003e\n\u003cli\u003eModulation compared to ground potential = Max. ±38 V\u003c\/li\u003e\n\u003cli\u003eOSSD signal connections = Permitted Max. test pulse length: 500 µs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160963830013,"sku":"8BVI0014HCD0-000-1","price":2598.08,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/8BVI0014HCD0-000-1.jpg?v=1785723181"},{"product_id":"8b0p0440hw00-0001","title":"B\u0026R 8B0P0440HW00-0001 | B\u0026R","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Motion control \u0026gt; ACOPOSmulti \u0026gt; Passive power supply modules \u0026gt; Wall mounting\u003c\/p\u003e\n\u003cp\u003eExtensive input voltage range Integrated connection for external braking resistor ACOPOSmulti power supply module passive, 44 A, AS, wall mounting.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupport\u003c\/li\u003e\n\u003cli\u003eDynamic node allocation (DNA) = Yes\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = In preparation\u003c\/li\u003e\n\u003cli\u003eUL = cULus E225616 Power conversion equipment\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0xA8EA\u003c\/li\u003e\n\u003cli\u003eCooling and mounting type = Wall mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMains connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMax. chargeable DC bus capacitance depending on mains voltage\u003c\/li\u003e\n\u003cli\u003e400 VAC = 14.4 mF\u003c\/li\u003e\n\u003cli\u003e480 VAC = 10 mF\u003c\/li\u003e\n\u003cli\u003eExecution\u003c\/li\u003e\n\u003cli\u003eL1, L2, L3, PE = Connector\u003c\/li\u003e\n\u003cli\u003ePE = M5 threaded bolt\u003c\/li\u003e\n\u003cli\u003eShield connection = Yes\u003c\/li\u003e\n\u003cli\u003eTerminal connection cross section\u003c\/li\u003e\n\u003cli\u003eFlexible and fine-stranded wires\u003c\/li\u003e\n\u003cli\u003eWith wire end sleeve = 0.5 to 16 mm²\u003c\/li\u003e\n\u003cli\u003eApprobation data\u003c\/li\u003e\n\u003cli\u003eUL\/C-UL-US = 20 to 6 AWG\u003c\/li\u003e\n\u003cli\u003eCSA = 20 to 6 AWG\u003c\/li\u003e\n\u003cli\u003eNetwork configurations = TT, TN-S, TN-C-S\u003c\/li\u003e\n\u003cli\u003eMains input voltage = 3x 380 to 3x 500 VAC ±10%\u003c\/li\u003e\n\u003cli\u003eFrequency = 50 \/ 60 Hz ±4%\u003c\/li\u003e\n\u003cli\u003eInstalled load = Max. 30.4 kVA\u003c\/li\u003e\n\u003cli\u003ePower dissipation with continuous power = Approx. 300 W\u003c\/li\u003e\n\u003cli\u003eInrush current at 400 VAC = 10 A\u003c\/li\u003e\n\u003cli\u003eSwitch-on interval = \u0026gt;120 s\u003c\/li\u003e\n\u003cli\u003eIntegrated line filter per EN 61800-3, category C3 = No\u003c\/li\u003e\n\u003cli\u003eIntegrated regeneration choke = No\u003c\/li\u003e\n\u003cli\u003eRegenerative = No\u003c\/li\u003e\n\u003cli\u003ePower factor correction (PFC) = No\u003c\/li\u003e\n\u003cli\u003eLine fuse = Max. 132 A (gG fuses per IEC 60269-1 or Class CC, J, T) Max. 110 A (circuit breaker per EN 60947-2 or UL 489)\u003c\/li\u003e\n\u003cli\u003eTerminal cable cross section dimension of shield connection = 23 to 35 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDC bus connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage\u003c\/li\u003e\n\u003cli\u003eNominal = 537 to 707 VDC\u003c\/li\u003e\n\u003cli\u003eReduction of continuous power depending on mains input voltage\u003c\/li\u003e\n\u003cli\u003eMains input voltage \u0026lt;3x 400 VAC = 40 W\/V * (400 V - Mains input voltage)\u003c\/li\u003e\n\u003cli\u003eReduction of continuous power depending on installation elevation\u003c\/li\u003e\n\u003cli\u003eStarting at 500 m above sea level = 1.6 kW per 1000 m\u003c\/li\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eOverload protection = Yes\u003c\/li\u003e\n\u003cli\u003eShort-circuit and ground fault protection = No\u003c\/li\u003e\n\u003cli\u003eContinuous power = 16 kW\u003c\/li\u003e\n\u003cli\u003eReduction of continuous power depending on cooling method = In preparation\u003c\/li\u003e\n\u003cli\u003ePeak power output (supply) = 48 kW\u003c\/li\u003e\n\u003cli\u003ePower dissipation with continuous power = In preparation\u003c\/li\u003e\n\u003cli\u003eDC bus capacitance = 1320 µF\u003c\/li\u003e\n\u003cli\u003eExecution = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput voltage = 25 VDC ±1.6%\u003c\/li\u003e\n\u003cli\u003eInput capacitance = 23.5 µF\u003c\/li\u003e\n\u003cli\u003eMax. power consumption = 12 W\u003c\/li\u003e\n\u003cli\u003eExecution = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMotor holding brake connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTerminal connection cross section\u003c\/li\u003e\n\u003cli\u003eFlexible and fine-stranded wires\u003c\/li\u003e\n\u003cli\u003eWith wire end sleeve = 0.5 to 6 mm²\u003c\/li\u003e\n\u003cli\u003eApprobation data\u003c\/li\u003e\n\u003cli\u003eUL\/C-UL-US = 20 to 8 AWG\u003c\/li\u003e\n\u003cli\u003eCSA = 20 to 8 AWG\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBraking resistor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExecution\u003c\/li\u003e\n\u003cli\u003eRB+, RB-, PE = Connector\u003c\/li\u003e\n\u003cli\u003eShield connection = Yes\u003c\/li\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eOverload protection = Yes\u003c\/li\u003e\n\u003cli\u003eShort-circuit and ground fault protection = Yes (with RB+ by externally replaceable melting fuse)\u003c\/li\u003e\n\u003cli\u003ePeak power output = 65 kW (max. 1 s)\u003c\/li\u003e\n\u003cli\u003eContinuous power = 3 kW\u003c\/li\u003e\n\u003cli\u003eMin. braking resistance = 7.5 Ω\u003c\/li\u003e\n\u003cli\u003eRated current of built-in fuse = 30 A (fast-acting)\u003c\/li\u003e\n\u003cli\u003eTerminal cable cross section dimension of shield connection = 23 to 35 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEnergy efficiency (IE classification)\u003c\/li\u003e\n\u003cli\u003ePower dissipation relative to continuous apparent power = IE2 (10;25) 0.2% IE2 (50;25) 0.3% IE2 (10;50) 0.2% IE2 (50;50) 0.3% IE2 (90;50) 0.6% IE2 (10;100) 0.3% IE2 (50;100) 0.6% IE2 (90;100) 1.3%\u003c\/li\u003e\n\u003cli\u003eNominal losses in standby mode = 6 W\u003c\/li\u003e\n\u003cli\u003eDischarge capacitance = 0.9 µF\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperating conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePermissible mounting orientations\u003c\/li\u003e\n\u003cli\u003eHanging vertically = Yes\u003c\/li\u003e\n\u003cli\u003eHorizontal, face up = Yes\u003c\/li\u003e\n\u003cli\u003eStanding horizontally = No\u003c\/li\u003e\n\u003cli\u003eInstallation elevation above sea level\u003c\/li\u003e\n\u003cli\u003eNominal = 0 to 500 m\u003c\/li\u003e\n\u003cli\u003eMaximum = 4000 m\u003c\/li\u003e\n\u003cli\u003ePollution degree per EN 61800-5-1 = 2 (non-conductive pollution)\u003c\/li\u003e\n\u003cli\u003eOvervoltage category per EN 61800-5-1 = III\u003c\/li\u003e\n\u003cli\u003eDegree of protection per EN 60529 = IP20\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature\u003c\/li\u003e\n\u003cli\u003eOperation\u003c\/li\u003e\n\u003cli\u003eNominal = 5 to 40°C\u003c\/li\u003e\n\u003cli\u003eMaximum = 55°C\u003c\/li\u003e\n\u003cli\u003eStorage = -25 to 55°C\u003c\/li\u003e\n\u003cli\u003eTransport = -25 to 70°C\u003c\/li\u003e\n\u003cli\u003eRelative humidity\u003c\/li\u003e\n\u003cli\u003eOperation = 5 to 85%\u003c\/li\u003e\n\u003cli\u003eStorage = 5 to 95%\u003c\/li\u003e\n\u003cli\u003eTransport = Max. 95% at 40°C\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"Never Used Surplus","offer_id":70984813215997,"sku":"8B0P0440HW00-0001","price":6871.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/8B0P0440HW00-0001.jpg?v=1785722819"},{"product_id":"8b0p0220hw00-0011","title":"B\u0026R 8B0P0220HW00-0011 | B\u0026R","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Motion control \u0026gt; ACOPOSmulti \u0026gt; Passive power supply modules \u0026gt; Wall mounting\u003c\/p\u003e\n\u003cp\u003eWide input voltage range Integrated connection for external braking resistor Passive motor short circuit brake A motor with a hanging load is connected to an ACOPOSmulti drive system with passive power supply module 8B0P with passive motor short circuit brake.\u003c\/p\u003e\n\u003cp\u003eIf the power supply to the drive system is disconnected and the hanging load begins sinking (due to failure of the motor holding brake, for example), then the motor axis rotates and the DC bus voltage increases.\u003c\/p\u003e\n\u003cp\u003eIf the DC bus voltage overshoots a value of 15 VDC, then the DC bus is shorted via a thyristor.\u003c\/p\u003e\n\u003cp\u003eThis limits the speed at which the hanging load sinks.\u003c\/p\u003e\n\u003cp\u003eThe passive motor short circuit brake is designed for up to 25 kW of power.\u003c\/p\u003e\n\u003cp\u003eOne fault event is permitted to occur maximum once every 15 minutes for this amount of power.\u003c\/p\u003e\n\u003cp\u003eThe passive motor short circuit brake is always active and cannot be influenced by the user! The passive motor short circuit brake works without current limiting.\u003c\/p\u003e\n\u003cp\u003eAs a result, irreparable damage to drive system components (passive power supply module 8B0P, motor, etc.) is possible at excessively high power values.\u003c\/p\u003e\n\u003cp\u003eThe passive motor short circuit brake is not monitored.\u003c\/p\u003e\n\u003cp\u003eIt therefore has no effect in the event of component failure! ACOPOSmulti power supply module passive, 22 A, AS, wall mounting, passive motor short circuit brake.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupport\u003c\/li\u003e\n\u003cli\u003eDynamic node allocation (DNA) = Yes\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = In preparation\u003c\/li\u003e\n\u003cli\u003eUL = cULus E225616 Power conversion equipment\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eNote = Integrated passive motor short circuit brake\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0xA988\u003c\/li\u003e\n\u003cli\u003eCooling and mounting type = Wall mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMains connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMax. chargeable DC bus capacitance depending on mains voltage\u003c\/li\u003e\n\u003cli\u003e400 VAC = 14.4 mF\u003c\/li\u003e\n\u003cli\u003e480 VAC = 10 mF\u003c\/li\u003e\n\u003cli\u003eExecution\u003c\/li\u003e\n\u003cli\u003eL1, L2, L3, PE = Connector\u003c\/li\u003e\n\u003cli\u003ePE = M5 threaded bolt\u003c\/li\u003e\n\u003cli\u003eShield connection = Yes\u003c\/li\u003e\n\u003cli\u003eTerminal connection cross section\u003c\/li\u003e\n\u003cli\u003eFlexible and fine-stranded wires\u003c\/li\u003e\n\u003cli\u003eWith wire end sleeve = 0.5 to 16 mm²\u003c\/li\u003e\n\u003cli\u003eApprobation data\u003c\/li\u003e\n\u003cli\u003eUL\/C-UL-US = 20 to 6 AWG\u003c\/li\u003e\n\u003cli\u003eCSA = 20 to 6 AWG\u003c\/li\u003e\n\u003cli\u003eNetwork configurations = TT, TN-S, TN-C-S\u003c\/li\u003e\n\u003cli\u003eMains input voltage = 3x 380 to 3x 500 VAC ±10%\u003c\/li\u003e\n\u003cli\u003eFrequency = 50 \/ 60 Hz ±4%\u003c\/li\u003e\n\u003cli\u003eInstalled load = Max. 15.6 kVA\u003c\/li\u003e\n\u003cli\u003ePower dissipation with continuous power = Approx. 130 W\u003c\/li\u003e\n\u003cli\u003eInrush current at 400 VAC = 10 A\u003c\/li\u003e\n\u003cli\u003eSwitch-on interval = \u0026gt;120 s\u003c\/li\u003e\n\u003cli\u003eIntegrated line filter per EN 61800-3, category C3 = No\u003c\/li\u003e\n\u003cli\u003eIntegrated regeneration choke = No\u003c\/li\u003e\n\u003cli\u003eRegenerative = No\u003c\/li\u003e\n\u003cli\u003ePower factor correction (PFC) = No\u003c\/li\u003e\n\u003cli\u003eLine fuse = Max. 66 A (gG fuses per IEC 60269-1 or Class CC, J, T) Max. 55 A (circuit breaker per EN 60947-2 or UL 489)\u003c\/li\u003e\n\u003cli\u003eTerminal cable cross section dimension of shield connection = 23 to 35 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDC bus connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage\u003c\/li\u003e\n\u003cli\u003eNominal = 537 to 707 VDC\u003c\/li\u003e\n\u003cli\u003eReduction of continuous power depending on mains input voltage\u003c\/li\u003e\n\u003cli\u003eMains input voltage \u0026lt;3x 400 VAC = 20 W\/V * (400 V - Mains input voltage)\u003c\/li\u003e\n\u003cli\u003eReduction of continuous power depending on installation elevation\u003c\/li\u003e\n\u003cli\u003eStarting at 500 m above sea level = 0.8 kW per 1000 m\u003c\/li\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eOverload protection = Yes\u003c\/li\u003e\n\u003cli\u003eShort-circuit and ground fault protection = No\u003c\/li\u003e\n\u003cli\u003eContinuous power = 8 kW\u003c\/li\u003e\n\u003cli\u003eReduction of continuous power depending on cooling method = In preparation\u003c\/li\u003e\n\u003cli\u003ePeak power output (supply) = 24 kW\u003c\/li\u003e\n\u003cli\u003ePower dissipation with continuous power = In preparation\u003c\/li\u003e\n\u003cli\u003eDC bus capacitance = 660 µF\u003c\/li\u003e\n\u003cli\u003eExecution = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput voltage = 25 VDC ±1.6%\u003c\/li\u003e\n\u003cli\u003eInput capacitance = 23.5 µF\u003c\/li\u003e\n\u003cli\u003eMax. power consumption = 12 W\u003c\/li\u003e\n\u003cli\u003eExecution = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMotor holding brake connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTerminal connection cross section\u003c\/li\u003e\n\u003cli\u003eFlexible and fine-stranded wires\u003c\/li\u003e\n\u003cli\u003eWith wire end sleeve = 0.5 to 6 mm²\u003c\/li\u003e\n\u003cli\u003eApprobation data\u003c\/li\u003e\n\u003cli\u003eUL\/C-UL-US = 20 to 6 AWG\u003c\/li\u003e\n\u003cli\u003eCSA = 20 to 6 AWG\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eBraking resistor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExecution\u003c\/li\u003e\n\u003cli\u003eRB+, RB-, PE = Connector\u003c\/li\u003e\n\u003cli\u003eShield connection = Yes\u003c\/li\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eOverload protection = Yes\u003c\/li\u003e\n\u003cli\u003eShort-circuit and ground fault protection = Yes (with RB+ by externally replaceable melting fuse)\u003c\/li\u003e\n\u003cli\u003ePeak power output = 40 kW (max. 1 s)\u003c\/li\u003e\n\u003cli\u003eContinuous power = 3 kW\u003c\/li\u003e\n\u003cli\u003eMin. braking resistance = 12 Ω\u003c\/li\u003e\n\u003cli\u003eRated current of built-in fuse = 30 A (fast-acting)\u003c\/li\u003e\n\u003cli\u003eTerminal cable cross section dimension of shield connection = 23 to 35 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEnergy efficiency (IE classification)\u003c\/li\u003e\n\u003cli\u003ePower dissipation relative to continuous apparent power = IE2 (10;25) 0.4% IE2 (50;25) 0.5% IE2 (10;50) 0.4% IE2 (50;50) 0.6% IE2 (90;50) 0.8% IE2 (10;100) 0.5% IE2 (50;100) 0.8% IE2 (90;100) 1.5%\u003c\/li\u003e\n\u003cli\u003eNominal losses in standby mode = 6 W\u003c\/li\u003e\n\u003cli\u003eDischarge capacitance = 0.9 µF\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperating conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePermissible mounting orientations\u003c\/li\u003e\n\u003cli\u003eHanging vertically = Yes\u003c\/li\u003e\n\u003cli\u003eHorizontal, face up = Yes\u003c\/li\u003e\n\u003cli\u003eStanding horizontally = No\u003c\/li\u003e\n\u003cli\u003eInstallation elevation above sea level\u003c\/li\u003e\n\u003cli\u003eNominal = 0 to 500 m\u003c\/li\u003e\n\u003cli\u003eMaximum = 4000 m\u003c\/li\u003e\n\u003cli\u003ePollution degree per EN 61800-5-1 = 2 (non-conductive pollution)\u003c\/li\u003e\n\u003cli\u003eOvervoltage category per EN 61800-5-1 = III\u003c\/li\u003e\n\u003cli\u003eDegree of protection per EN 60529 = IP20\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature\u003c\/li\u003e\n\u003cli\u003eOperation\u003c\/li\u003e\n\u003cli\u003eNominal = 5 to 40°C\u003c\/li\u003e\n\u003cli\u003eMaximum = 55°C\u003c\/li\u003e\n\u003cli\u003eStorage = -25 to 55°C\u003c\/li\u003e\n\u003cli\u003eTransport = -25 to 70°C\u003c\/li\u003e\n\u003cli\u003eRelative humidity\u003c\/li\u003e\n\u003cli\u003eOperation = 5 to 85%\u003c\/li\u003e\n\u003cli\u003eStorage = 5 to 95%\u003c\/li\u003e\n\u003cli\u003eTransport = Max. 95% at 40°C\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"Never Used Surplus","offer_id":70984813838589,"sku":"8B0P0220HW00-0011","price":7749.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/8B0P0220HW00-0011.jpg?v=1785722811"},{"product_id":"8b0f0550h000-000-1","title":"B\u0026R 8B0F0550H000-000-1 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Motion control \u0026gt; ACOPOS P3 \u0026gt; Passive line filter\u003c\/p\u003e\n\u003cp\u003eWide mains input voltage range Optimally suited for ACOPOSmulti 8B0P power supply modules Compliance with limit values per CISPR11, group 2, class A Line filter, passive, 55 A, 3x 520 VAC, 50\/60 Hz, IP20.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = Not applicable\u003c\/li\u003e\n\u003cli\u003eUL = cULus E225616 Power conversion equipment\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eCooling and mounting type = Wall mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMains connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReduction of continuous current depending on ambient temperature\u003c\/li\u003e\n\u003cli\u003eStarting at 50°C = 0.565 A\/K\u003c\/li\u003e\n\u003cli\u003eReduction of continuous current depending on installation elevation\u003c\/li\u003e\n\u003cli\u003eStarting at 1000 m above sea level = 2.75 A eff per 1000 m\u003c\/li\u003e\n\u003cli\u003eVariant\u003c\/li\u003e\n\u003cli\u003eShield connection\u003c\/li\u003e\n\u003cli\u003eOn mains = No\u003c\/li\u003e\n\u003cli\u003eOn device = No\u003c\/li\u003e\n\u003cli\u003eL1, L2, L3 and L1´, L2´, L3´ = Terminals\u003c\/li\u003e\n\u003cli\u003ePE = M6 threaded bolt\u003c\/li\u003e\n\u003cli\u003eTerminal connection cross section\u003c\/li\u003e\n\u003cli\u003eFlexible and fine-stranded wires\u003c\/li\u003e\n\u003cli\u003eWith wire end sleeve = Max. 16 mm²\u003c\/li\u003e\n\u003cli\u003eApprobation data\u003c\/li\u003e\n\u003cli\u003eUL\/C-UL-US = 4 AWG\u003c\/li\u003e\n\u003cli\u003eCSA = 4 AWG\u003c\/li\u003e\n\u003cli\u003ePermissible network configurations = TT, TN\u003c\/li\u003e\n\u003cli\u003eMains input voltage = Max. 3x 520 VAC\u003c\/li\u003e\n\u003cli\u003eFrequency = Max. 60 Hz\u003c\/li\u003e\n\u003cli\u003eContinuous current = 55 A eff\u003c\/li\u003e\n\u003cli\u003ePeak current = 82.5 A eff (\u0026lt;1 min), 1x\/h\u003c\/li\u003e\n\u003cli\u003ePower dissipation = 25.9 W\u003c\/li\u003e\n\u003cli\u003eLine filter per EN 61800-3, category C3 = Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDischarge capacitance = 0.4 µF\u003c\/li\u003e\n\u003cli\u003eLeakage current = 33 mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperating conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePermissible mounting orientations\u003c\/li\u003e\n\u003cli\u003eHanging vertically = Yes\u003c\/li\u003e\n\u003cli\u003eHorizontal, face up = Yes\u003c\/li\u003e\n\u003cli\u003eStanding horizontally = No\u003c\/li\u003e\n\u003cli\u003eInstallation elevation above sea level\u003c\/li\u003e\n\u003cli\u003eNominal = 0 to 1000 m\u003c\/li\u003e\n\u003cli\u003eMaximum = 4000 m\u003c\/li\u003e\n\u003cli\u003ePollution degree per EN 61800-5-1 = In preparation\u003c\/li\u003e\n\u003cli\u003eOvervoltage category per IEC 60950 = II\u003c\/li\u003e\n\u003cli\u003eDegree of protection per EN 60529 = IP20\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature\u003c\/li\u003e\n\u003cli\u003eOperation\u003c\/li\u003e\n\u003cli\u003eNominal = 5 to 40°C\u003c\/li\u003e\n\u003cli\u003eMaximum = 55°C\u003c\/li\u003e\n\u003cli\u003eStorage = -25 to 55°C\u003c\/li\u003e\n\u003cli\u003eTransport = -25 to 70°C\u003c\/li\u003e\n\u003cli\u003eRelative humidity\u003c\/li\u003e\n\u003cli\u003eOperation = 5 to 85%\u003c\/li\u003e\n\u003cli\u003eStorage = 5 to 95%\u003c\/li\u003e\n\u003cli\u003eTransport = Max. 95% at 40°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDimensions\u003c\/li\u003e\n\u003cli\u003eWidth = 85 mm\u003c\/li\u003e\n\u003cli\u003eHeight = 250 mm\u003c\/li\u003e\n\u003cli\u003eDepth = 90 mm\u003c\/li\u003e\n\u003cli\u003eVibration and shock = 3M4 per IEC 60721-3-3\u003c\/li\u003e\n\u003cli\u003eWeight = 2 kg\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160964452605,"sku":"8B0F0550H000-000-1","price":992.69,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/8B0F0550H000-000-1.jpg?v=1785723163"},{"product_id":"8b0c0320hw00-002-1","title":"B\u0026R 8B0C0320HW00-002-1 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Motion control \u0026gt; ACOPOSmulti \u0026gt; Auxiliary supply modules 800W \u0026gt; Wall mounting\u003c\/p\u003e\n\u003cp\u003eConnections for supplying external 24 V devices Extensive protective measures ACOPOSmulti auxiliary supply module, 32 A, AS, wall mounting, 24 VOut 1x 32 A, 1x 5 A.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = In preparation\u003c\/li\u003e\n\u003cli\u003eUL = cULus E225616 Power conversion equipment\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eCooling and mounting type = Wall mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDC bus connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage\u003c\/li\u003e\n\u003cli\u003eNominal = 750 VDC\u003c\/li\u003e\n\u003cli\u003eOperating range in continuous operation = 260 to 800 VDC\u003c\/li\u003e\n\u003cli\u003eFull continuous power = 315 to 800 VDC\u003c\/li\u003e\n\u003cli\u003eContinuous power consumption = Max. 880 W\u003c\/li\u003e\n\u003cli\u003ePower dissipation with continuous power = 22 W (0% continuous power) 35 W (50% continuous power) 80 W (100% continuous power)\u003c\/li\u003e\n\u003cli\u003eDC bus capacitance = 220 nF\u003c\/li\u003e\n\u003cli\u003eVariant = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC output\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput voltage\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 260 to 315 VDC = 25 VDC * (U DC \/ 315)\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 315 to 800 VDC = 24 VDC ±6%\u003c\/li\u003e\n\u003cli\u003eReduction of continuous power depending on installation elevation\u003c\/li\u003e\n\u003cli\u003eStarting at 500 m above sea level = 80 W per 1000 m\u003c\/li\u003e\n\u003cli\u003eContinuous power = 800 W\u003c\/li\u003e\n\u003cli\u003eContinuous current = 32 ADC\u003c\/li\u003e\n\u003cli\u003eReduction of continuous power at ambient temperatures starting at 40°C = No reduction\u003c\/li\u003e\n\u003cli\u003eReduction of continuous power depending on cooling method = No reduction\u003c\/li\u003e\n\u003cli\u003eStartup delay = Max. 1 s\u003c\/li\u003e\n\u003cli\u003eStartup time = Approx. 5 to 20 ms\u003c\/li\u003e\n\u003cli\u003eResidual ripple = Typ. 50 mV SS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC internal system power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePeak current (\u0026lt;4 s)\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 350 to 800 VDC = 42 ADC\u003c\/li\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eNo-load proof = Yes\u003c\/li\u003e\n\u003cli\u003eOverload-proof = Yes\u003c\/li\u003e\n\u003cli\u003eShort-circuit proof = Yes\u003c\/li\u003e\n\u003cli\u003eFeedback protection = Max. 26 VDC (also when the power is switched off)\u003c\/li\u003e\n\u003cli\u003eOvertemperature protection = Yes\u003c\/li\u003e\n\u003cli\u003eDielectric strength to ground = ±50 VDC\u003c\/li\u003e\n\u003cli\u003eOutput\/Input isolation = SELV \/ PELV requirements\u003c\/li\u003e\n\u003cli\u003eOutput voltage = 25 VDC ±1.6%\u003c\/li\u003e\n\u003cli\u003eVariant = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC Out\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput voltage\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 260 to 315 VDC = 25 VDC * (U DC \/ 315)\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 315 to 800 VDC = 24 VDC ±6%\u003c\/li\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eNo-load proof = Yes\u003c\/li\u003e\n\u003cli\u003eOverload-proof = Yes\u003c\/li\u003e\n\u003cli\u003eShort-circuit proof = Yes\u003c\/li\u003e\n\u003cli\u003eFeedback protection = Max. 35 VDC (also when the power is switched off)\u003c\/li\u003e\n\u003cli\u003eOvertemperature protection = Yes\u003c\/li\u003e\n\u003cli\u003eDielectric strength to ground = ±50 VDC\u003c\/li\u003e\n\u003cli\u003eOutput\/Input isolation = SELV \/ PELV requirements\u003c\/li\u003e\n\u003cli\u003eVariant\u003c\/li\u003e\n\u003cli\u003e24 VDC, COM = Connector\u003c\/li\u003e\n\u003cli\u003eTerminal connection cross section of 24 VDC Out 1 output\u003c\/li\u003e\n\u003cli\u003eFlexible and fine-stranded wires\u003c\/li\u003e\n\u003cli\u003eWith wire end sleeve = 0.25 to 6 mm²\u003c\/li\u003e\n\u003cli\u003eApprobation data\u003c\/li\u003e\n\u003cli\u003eUL\/C-UL-US = 22 to 10 AWG\u003c\/li\u003e\n\u003cli\u003eCSA = 22 to 10 AWG\u003c\/li\u003e\n\u003cli\u003eTerminal connection cross section of 24 VDC Out 2 output\u003c\/li\u003e\n\u003cli\u003eWith wire end sleeve = 0.25 to 2.5 mm²\u003c\/li\u003e\n\u003cli\u003eUL\/C-UL-US = 22 to 12 AWG\u003c\/li\u003e\n\u003cli\u003eCSA = 22 to 12 AWG\u003c\/li\u003e\n\u003cli\u003eProtection of 24 VDC Out 1 output = 32 A (slow-blow) electronic, automatic reset\u003c\/li\u003e\n\u003cli\u003eProtection of 24 VDC Out 2 output = 5 A (slow-blow) electronic, automatic reset\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC Out 1 controller input\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eInput - 24 VDC = Yes\u003c\/li\u003e\n\u003cli\u003eInput voltage\u003c\/li\u003e\n\u003cli\u003eNominal = 24 VDC\u003c\/li\u003e\n\u003cli\u003eMaximum = 30 VDC\u003c\/li\u003e\n\u003cli\u003eSwitching threshold\u003c\/li\u003e\n\u003cli\u003eLow (24 VDC Out 1 is switched on) = \u0026lt;5 V\u003c\/li\u003e\n\u003cli\u003eHigh (24 VDC Out 1 is switched off) = \u0026gt;15 V\u003c\/li\u003e\n\u003cli\u003eSwitching delay\u003c\/li\u003e\n\u003cli\u003eON (24 VDC Out 1 is switched on) = Max. 25 ms\u003c\/li\u003e\n\u003cli\u003eOFF (24 VDC Out 1 is switched off) = Max. 0.25 ms\u003c\/li\u003e\n\u003cli\u003eTerminal connection cross sections\u003c\/li\u003e\n\u003cli\u003eFlexible and fine-stranded wires\u003c\/li\u003e\n\u003cli\u003eWith wire end sleeve = 0.25 to 2.5 mm²\u003c\/li\u003e\n\u003cli\u003eApprobation data\u003c\/li\u003e\n\u003cli\u003eUL\/C-UL-US = 30 to 12 AWG\u003c\/li\u003e\n\u003cli\u003eCSA = 22 to 12 AWG\u003c\/li\u003e\n\u003cli\u003eCircuit = Sink\u003c\/li\u003e\n\u003cli\u003eModulation compared to ground potential = Max. ±50 V\u003c\/li\u003e\n\u003cli\u003eInput current at nominal voltage = Approx. 10 mA\u003c\/li\u003e\n\u003cli\u003eVariant = Connector\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperating conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePermissible mounting orientations\u003c\/li\u003e\n\u003cli\u003eHanging vertically = Yes\u003c\/li\u003e\n\u003cli\u003eHorizontal, face up = Yes\u003c\/li\u003e\n\u003cli\u003eStanding horizontally = No\u003c\/li\u003e\n\u003cli\u003eInstallation elevation above sea level\u003c\/li\u003e\n\u003cli\u003eNominal = 0 to 500 m\u003c\/li\u003e\n\u003cli\u003eMaximum = 4000 m\u003c\/li\u003e\n\u003cli\u003ePollution degree per EN 61800-5-1 = 2 (non-conductive pollution)\u003c\/li\u003e\n\u003cli\u003eOvervoltage category per EN 61800-5-1 = III\u003c\/li\u003e\n\u003cli\u003eDegree of protection per EN 60529 = IP20\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160964780285,"sku":"8B0C0320HW00-002-1","price":5830.01,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/8B0C0320HW00-002-1.jpg?v=1785723154"},{"product_id":"8b0c0160hw00-0011","title":"B\u0026R 8B0C0160HW00-0011 | B\u0026R","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Motion control \u0026gt; ACOPOSmulti \u0026gt; Auxiliary supply modules 400W \u0026gt; Wall mounting\u003c\/p\u003e\n\u003cp\u003eConnections for supplying external 24 V devices Extensive protective measures ACOPOSmulti auxiliary supply module, 16 A, AS, wall mounting, 24 VOut 1x 16 A, 1x 5 A.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = In preparation\u003c\/li\u003e\n\u003cli\u003eUL = cULus E225616 Power conversion equipment\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eCooling and mounting type = Wall mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDC bus connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage\u003c\/li\u003e\n\u003cli\u003eNominal = 750 VDC\u003c\/li\u003e\n\u003cli\u003eOperating range in continuous operation = 260 to 800 VDC\u003c\/li\u003e\n\u003cli\u003eFull continuous power = 315 to 800 VDC\u003c\/li\u003e\n\u003cli\u003eContinuous power consumption = Max. 445 W\u003c\/li\u003e\n\u003cli\u003ePower dissipation with continuous power = 22 W (0% continuous power) 27 W (50% continuous power) 45 W (100% continuous power)\u003c\/li\u003e\n\u003cli\u003eDC bus capacitance = 220 nF\u003c\/li\u003e\n\u003cli\u003eVariant = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC output\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput voltage\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 260 to 315 VDC = 25 VDC * (U DC \/ 315)\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 315 to 800 VDC = 24 VDC ±6%\u003c\/li\u003e\n\u003cli\u003eReduction of continuous power depending on installation elevation\u003c\/li\u003e\n\u003cli\u003eStarting at 500 m above sea level = 40 W per 1000 m\u003c\/li\u003e\n\u003cli\u003eTerminal connection cross section of 24 VDC Out 1 output\u003c\/li\u003e\n\u003cli\u003eFlexible and fine-stranded wires\u003c\/li\u003e\n\u003cli\u003eWith wire end sleeve = 0.5 to 6 mm²\u003c\/li\u003e\n\u003cli\u003eApprobation data\u003c\/li\u003e\n\u003cli\u003eUL\/C-UL-US = 22 to 10 AWG\u003c\/li\u003e\n\u003cli\u003eCSA = 22 to 10 AWG\u003c\/li\u003e\n\u003cli\u003eTerminal connection cross section of 24 VDC Out 2 output\u003c\/li\u003e\n\u003cli\u003eWith wire end sleeve = 0.2 to 2.5 mm²\u003c\/li\u003e\n\u003cli\u003eUL\/C-UL-US = 22 to 12 AWG\u003c\/li\u003e\n\u003cli\u003eCSA = 22 to 12 AWG\u003c\/li\u003e\n\u003cli\u003eContinuous power = 400 W\u003c\/li\u003e\n\u003cli\u003eContinuous current = 16 ADC\u003c\/li\u003e\n\u003cli\u003eReduction of continuous power at ambient temperatures starting at 40°C = No reduction\u003c\/li\u003e\n\u003cli\u003eReduction of continuous power depending on cooling method = No reduction\u003c\/li\u003e\n\u003cli\u003eStartup delay = Max. 1 s\u003c\/li\u003e\n\u003cli\u003eStartup time = Approx. 5 to 20 ms\u003c\/li\u003e\n\u003cli\u003eResidual ripple = Typ. 50 mV SS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC internal system power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePeak current (\u0026lt;4 s)\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 350 to 800 VDC = 21 ADC\u003c\/li\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eNo-load proof = Yes\u003c\/li\u003e\n\u003cli\u003eOverload-proof = Yes\u003c\/li\u003e\n\u003cli\u003eShort-circuit proof = Yes\u003c\/li\u003e\n\u003cli\u003eFeedback protection = Max. 26 VDC (also when the power is switched off)\u003c\/li\u003e\n\u003cli\u003eOvertemperature protection = Yes\u003c\/li\u003e\n\u003cli\u003eDielectric strength to ground = ±50 VDC\u003c\/li\u003e\n\u003cli\u003eOutput\/Input isolation = SELV \/ PELV requirements\u003c\/li\u003e\n\u003cli\u003eOutput voltage = 25 VDC ±1.6%\u003c\/li\u003e\n\u003cli\u003eVariant = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC Out\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput voltage\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 260 to 315 VDC = 25 VDC * (U DC \/ 315)\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 315 to 800 VDC = 24 VDC ±6%\u003c\/li\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eNo-load proof = Yes\u003c\/li\u003e\n\u003cli\u003eOverload-proof = Yes\u003c\/li\u003e\n\u003cli\u003eShort-circuit proof = Yes\u003c\/li\u003e\n\u003cli\u003eFeedback protection = Max. 35 VDC (also when the power is switched off)\u003c\/li\u003e\n\u003cli\u003eOvertemperature protection = Yes\u003c\/li\u003e\n\u003cli\u003eDielectric strength to ground = ±50 VDC\u003c\/li\u003e\n\u003cli\u003eOutput\/Input isolation = SELV \/ PELV requirements\u003c\/li\u003e\n\u003cli\u003eVariant\u003c\/li\u003e\n\u003cli\u003e24 VDC, COM = Connector\u003c\/li\u003e\n\u003cli\u003eProtection of 24 VDC Out 1 output = 16 A (slow-blow) electronic, automatic reset\u003c\/li\u003e\n\u003cli\u003eProtection of 24 VDC Out 2 output = 5 A (slow-blow) electronic, automatic reset\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC Out 1 controller input\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eInput - 24 VDC = Yes\u003c\/li\u003e\n\u003cli\u003eInput voltage\u003c\/li\u003e\n\u003cli\u003eNominal = 24 VDC\u003c\/li\u003e\n\u003cli\u003eMaximum = 30 VDC\u003c\/li\u003e\n\u003cli\u003eSwitching threshold\u003c\/li\u003e\n\u003cli\u003eLow (24 VDC Out 1 is switched on) = \u0026lt;5 V\u003c\/li\u003e\n\u003cli\u003eHigh (24 VDC Out 1 is switched off) = \u0026gt;15 V\u003c\/li\u003e\n\u003cli\u003eSwitching delay\u003c\/li\u003e\n\u003cli\u003eON (24 VDC Out 1 is switched on) = Max. 25 ms\u003c\/li\u003e\n\u003cli\u003eOFF (24 VDC Out 1 is switched off) = Max. 0.25 ms\u003c\/li\u003e\n\u003cli\u003eTerminal connection cross sections\u003c\/li\u003e\n\u003cli\u003eFlexible and fine-stranded wires\u003c\/li\u003e\n\u003cli\u003eWith wire end sleeve = 0.2 to 2.5 mm²\u003c\/li\u003e\n\u003cli\u003eApprobation data\u003c\/li\u003e\n\u003cli\u003eUL\/C-UL-US = 30 to 12 AWG\u003c\/li\u003e\n\u003cli\u003eCSA = 22 to 12 AWG\u003c\/li\u003e\n\u003cli\u003eCircuit = Sink\u003c\/li\u003e\n\u003cli\u003eModulation compared to ground potential = Max. ±50 V\u003c\/li\u003e\n\u003cli\u003eInput current at nominal voltage = Approx. 10 mA\u003c\/li\u003e\n\u003cli\u003eVariant = Connector\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperating conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePermissible mounting orientations\u003c\/li\u003e\n\u003cli\u003eHanging vertically = Yes\u003c\/li\u003e\n\u003cli\u003eHorizontal, face up = Yes\u003c\/li\u003e\n\u003cli\u003eStanding horizontally = No\u003c\/li\u003e\n\u003cli\u003eInstallation elevation above sea level\u003c\/li\u003e\n\u003cli\u003eNominal = 0 to 500 m\u003c\/li\u003e\n\u003cli\u003eMaximum = 4000 m\u003c\/li\u003e\n\u003cli\u003ePollution degree per EN 61800-5-1 = 2 (non-conductive pollution)\u003c\/li\u003e\n\u003cli\u003eOvervoltage category per EN 61800-5-1 = III\u003c\/li\u003e\n\u003cli\u003eDegree of protection per EN 60529 = IP20\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"Never Used Surplus","offer_id":70984814297341,"sku":"8B0C0160HW00-0011","price":4845.28,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/8B0C0160HW00-0011.jpg?v=1785722789"},{"product_id":"8b0c0320hw00-000-1","title":"B\u0026R 8B0C0320HW00-000-1 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Motion control \u0026gt; ACOPOSmulti \u0026gt; Auxiliary supply modules 800W \u0026gt; Wall mounting\u003c\/p\u003e\n\u003cp\u003eExtensive protective measures ACOPOSmulti auxiliary supply module, 32 A, AS, wall mounting.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = In preparation\u003c\/li\u003e\n\u003cli\u003eUL = cULus E225616 Power conversion equipment\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eCooling and mounting type = Wall mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDC bus connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage\u003c\/li\u003e\n\u003cli\u003eNominal = 750 VDC\u003c\/li\u003e\n\u003cli\u003eOperating range in continuous operation = 260 to 800 VDC\u003c\/li\u003e\n\u003cli\u003eFull continuous power = 315 to 800 VDC\u003c\/li\u003e\n\u003cli\u003eContinuous power consumption = Max. 880 W\u003c\/li\u003e\n\u003cli\u003ePower dissipation with continuous power = 22 W (0% continuous power) 35 W (50% continuous power) 80 W (100% continuous power)\u003c\/li\u003e\n\u003cli\u003eDC bus capacitance = 220 nF\u003c\/li\u003e\n\u003cli\u003eVariant = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC output\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput voltage\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 260 to 315 VDC = 25 VDC * (U DC \/ 315)\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 315 to 800 VDC = 24 VDC ±6%\u003c\/li\u003e\n\u003cli\u003eReduction of continuous power depending on installation elevation\u003c\/li\u003e\n\u003cli\u003eStarting at 500 m above sea level = 80 W per 1000 m\u003c\/li\u003e\n\u003cli\u003eContinuous power = 800 W\u003c\/li\u003e\n\u003cli\u003eContinuous current = 32 ADC\u003c\/li\u003e\n\u003cli\u003eReduction of continuous power at ambient temperatures starting at 40°C = No reduction\u003c\/li\u003e\n\u003cli\u003eReduction of continuous power depending on cooling method = No reduction\u003c\/li\u003e\n\u003cli\u003eStartup delay = Max. 1 s\u003c\/li\u003e\n\u003cli\u003eStartup time = Approx. 5 to 20 ms\u003c\/li\u003e\n\u003cli\u003eResidual ripple = Typ. 50 mV SS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e24 VDC internal system power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePeak current (\u0026lt;4 s)\u003c\/li\u003e\n\u003cli\u003eDC bus voltage (U DC ): 350 to 800 VDC = 42 ADC\u003c\/li\u003e\n\u003cli\u003eProtective measures\u003c\/li\u003e\n\u003cli\u003eNo-load proof = Yes\u003c\/li\u003e\n\u003cli\u003eOverload-proof = Yes\u003c\/li\u003e\n\u003cli\u003eShort-circuit proof = Yes\u003c\/li\u003e\n\u003cli\u003eFeedback protection = Max. 26 VDC (also when the power is switched off)\u003c\/li\u003e\n\u003cli\u003eOvertemperature protection = Yes\u003c\/li\u003e\n\u003cli\u003eDielectric strength to ground = ±50 VDC\u003c\/li\u003e\n\u003cli\u003eOutput\/Input isolation = SELV \/ PELV requirements\u003c\/li\u003e\n\u003cli\u003eOutput voltage = 25 VDC ±1.6%\u003c\/li\u003e\n\u003cli\u003eVariant = ACOPOSmulti backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperating conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePermissible mounting orientations\u003c\/li\u003e\n\u003cli\u003eHanging vertically = Yes\u003c\/li\u003e\n\u003cli\u003eHorizontal, face up = Yes\u003c\/li\u003e\n\u003cli\u003eStanding horizontally = No\u003c\/li\u003e\n\u003cli\u003eInstallation elevation above sea level\u003c\/li\u003e\n\u003cli\u003eNominal = 0 to 500 m\u003c\/li\u003e\n\u003cli\u003eMaximum = 4000 m\u003c\/li\u003e\n\u003cli\u003ePollution degree per EN 61800-5-1 = 2 (non-conductive pollution)\u003c\/li\u003e\n\u003cli\u003eOvervoltage category per EN 61800-5-1 = III\u003c\/li\u003e\n\u003cli\u003eDegree of protection per EN 60529 = IP20\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature\u003c\/li\u003e\n\u003cli\u003eOperation\u003c\/li\u003e\n\u003cli\u003eNominal = 5 to 40°C\u003c\/li\u003e\n\u003cli\u003eMaximum = 55°C\u003c\/li\u003e\n\u003cli\u003eStorage = -25 to 55°C\u003c\/li\u003e\n\u003cli\u003eTransport = -25 to 70°C\u003c\/li\u003e\n\u003cli\u003eRelative humidity\u003c\/li\u003e\n\u003cli\u003eOperation = 5 to 85%\u003c\/li\u003e\n\u003cli\u003eStorage = 5 to 95%\u003c\/li\u003e\n\u003cli\u003eTransport = Max. 95% at 40°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDimensions\u003c\/li\u003e\n\u003cli\u003eDepth\u003c\/li\u003e\n\u003cli\u003eWall mounting = 263 mm\u003c\/li\u003e\n\u003cli\u003eWidth = 53 mm\u003c\/li\u003e\n\u003cli\u003eHeight = 317 mm\u003c\/li\u003e\n\u003cli\u003eWeight = Approx. 3 kg\u003c\/li\u003e\n\u003cli\u003eModule width = 1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160964911357,"sku":"8B0C0320HW00-000-1","price":3927.55,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/8B0C0320HW00-000-1.jpg?v=1785723144"},{"product_id":"8ac123-60-1","title":"B\u0026R 8AC123-60-1 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Motion control \u0026gt; ACOPOS \u0026gt; Plug-in modules\u003c\/p\u003e\n\u003cp\u003eIncremental encoder and SSI absolute encoder interface for installation in ACOPOS servo drives Monitors encoder input signals Encoder supply voltage of 5V or 15V Compensates for a voltage drop at 5 V encoder voltage supply ACOPOS plug-in module, incremental encoder and SSI absolute encoder interface.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = Non-compliant\u003c\/li\u003e\n\u003cli\u003eUL = cULus E225616 Power conversion equipment\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eModule type = ACOPOS plug-in module\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0x1067\u003c\/li\u003e\n\u003cli\u003eSlot = Slots 2, 3 and 4\u003c\/li\u003e\n\u003cli\u003ePower consumption = Max. 7.5 W Depends on the current consumption of the connected encoder\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEncoder inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eEncoder - ACOPOS = Yes\u003c\/li\u003e\n\u003cli\u003eQuantity = 1\u003c\/li\u003e\n\u003cli\u003eSignal transmission = Differential signal transfer\u003c\/li\u003e\n\u003cli\u003eModule-side connection = 15-pin female DSUB\u003c\/li\u003e\n\u003cli\u003eStatus indicators = UP\/DN LEDs\u003c\/li\u003e\n\u003cli\u003eEncoder monitoring = Yes\u003c\/li\u003e\n\u003cli\u003eMax. encoder cable length = 50 m\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEncoder power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLoad capacity\u003c\/li\u003e\n\u003cli\u003e5 VDC = 350 mA\u003c\/li\u003e\n\u003cli\u003e15 VDC = 350 mA\u003c\/li\u003e\n\u003cli\u003eSense lines\u003c\/li\u003e\n\u003cli\u003eFor 5 VDC = Yes, 2, compensation of max. 2 V\u003c\/li\u003e\n\u003cli\u003eFor 15 VDC = No\u003c\/li\u003e\n\u003cli\u003eSupply voltages = Internal, optionally 5 V \/ 15 V\u003c\/li\u003e\n\u003cli\u003eShort-circuit proof, overload protection = Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIncremental encoders\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDifferential voltage inputs A, B, R\u003c\/li\u003e\n\u003cli\u003eMinimum = 2.5 V\u003c\/li\u003e\n\u003cli\u003eMaximum = 6 V\u003c\/li\u003e\n\u003cli\u003eCounter size = 32-bit\u003c\/li\u003e\n\u003cli\u003eInput frequency = Max. 200 kHz\u003c\/li\u003e\n\u003cli\u003eEvaluation = 4x\u003c\/li\u003e\n\u003cli\u003eSignal form = Square wave pulse\u003c\/li\u003e\n\u003cli\u003eCounter frequency = Max. 800 kHz\u003c\/li\u003e\n\u003cli\u003eReference frequency = Max. 200 kHz\u003c\/li\u003e\n\u003cli\u003eDistance between edges = Min. 0.6 µs\u003c\/li\u003e\n\u003cli\u003eInputs = A, A\\, B, B\\, R, R\\\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSSI absolute encoder\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDifferential voltage clock output - 120 Ω\u003c\/li\u003e\n\u003cli\u003eMinimum = 2.5 V\u003c\/li\u003e\n\u003cli\u003eMaximum = 5 V\u003c\/li\u003e\n\u003cli\u003eDifferential voltage data input\u003c\/li\u003e\n\u003cli\u003eMaximum = 6 V\u003c\/li\u003e\n\u003cli\u003eCoding = Gray, binary\u003c\/li\u003e\n\u003cli\u003eBaud rate = 200 kbit\/s\u003c\/li\u003e\n\u003cli\u003eWord size = Max. 31-bit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature\u003c\/li\u003e\n\u003cli\u003eOperation\u003c\/li\u003e\n\u003cli\u003eNominal = 5 to 40°C\u003c\/li\u003e\n\u003cli\u003eMaximum = 55°C\u003c\/li\u003e\n\u003cli\u003eStorage = -25 to 55°C\u003c\/li\u003e\n\u003cli\u003eTransport = -25 to 70°C\u003c\/li\u003e\n\u003cli\u003eRelative humidity\u003c\/li\u003e\n\u003cli\u003eOperation = 5 to 85%\u003c\/li\u003e\n\u003cli\u003eStorage = 5 to 95%\u003c\/li\u003e\n\u003cli\u003eTransport = Max. 95% at 40°C\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160965075197,"sku":"8AC123-60-1","price":827.69,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/8AC123-60-1.jpg?v=1785723137"},{"product_id":"8ac122-60-2","title":"B\u0026R 8AC122-60-2 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Motion control \u0026gt; ACOPOS \u0026gt; Plug-in modules\u003c\/p\u003e\n\u003cp\u003eTo Confirm.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eTo Confirm\u003c\/p\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160965468413,"sku":"8AC122-60-2","price":1082.58,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/8AC122-60-2.jpg?v=1785723115"},{"product_id":"8ac120-60-1","title":"B\u0026R 8AC120-60-1 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Motion control \u0026gt; ACOPOS \u0026gt; Plug-in modules\u003c\/p\u003e\n\u003cp\u003eEnDat 2.1 encoder interface for installation in ACOPOS servo drives Encoder monitoring Also suitable for evaluating simple incremental encoders with sinusoidal input signal ACOPOS plug-in module, EnDat encoder and sine incremental encoder interface.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower consumption\u003c\/li\u003e\n\u003cli\u003eDepends on connected encoder = Yes\u003c\/li\u003e\n\u003cli\u003eE0 ... EnDat single-turn, 512 lines = Max. 2.3 W\u003c\/li\u003e\n\u003cli\u003eE1 ... EnDat multi-turn, 512 lines = Max. 3.1 W\u003c\/li\u003e\n\u003cli\u003eE2 ... EnDat single-turn, 32 lines (inductive) = Max. 3.1 W\u003c\/li\u003e\n\u003cli\u003eE3 ... EnDat multi-turn, 32 lines (inductive) = Max. 3.1 W\u003c\/li\u003e\n\u003cli\u003eE4 ... EnDat single-turn, 512 lines = Max. 2.4 W\u003c\/li\u003e\n\u003cli\u003eE5 ... EnDat multi-turn, 512 lines = Max. 2.7 W\u003c\/li\u003e\n\u003cli\u003eE8 ... EnDat single-turn, 16 lines (inductive) = Max. 2.9 W\u003c\/li\u003e\n\u003cli\u003eE9 ... EnDat multi-turn, 16 lines (inductive) = Max. 3.1 W\u003c\/li\u003e\n\u003cli\u003eEA ... EnDat single-turn, 32 lines (inductive) = Max. 2.7 W\u003c\/li\u003e\n\u003cli\u003eEB ... EnDat multi-turn, 32 lines (inductive) = Max. 3.0 W\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = Non-compliant\u003c\/li\u003e\n\u003cli\u003eUL = cULus E225616 Power conversion equipment\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eModule type = ACOPOS plug-in module\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0x0FCC\u003c\/li\u003e\n\u003cli\u003eSlot = Slots 2, 3 and 4\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEncoder inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eEncoder - ACOPOS = No\u003c\/li\u003e\n\u003cli\u003eEncoder power supply\u003c\/li\u003e\n\u003cli\u003eOutput voltage = Typ. 5 V\u003c\/li\u003e\n\u003cli\u003eLoad capacity = 250 mA\u003c\/li\u003e\n\u003cli\u003eSense lines = 2, compensation of max. 2x 0.7 V\u003c\/li\u003e\n\u003cli\u003eSine\/Cosine inputs\u003c\/li\u003e\n\u003cli\u003eSignal transmission = Differential signals, symmetrical\u003c\/li\u003e\n\u003cli\u003eSignal frequency (-3 dB) = DC up to 300 kHz\u003c\/li\u003e\n\u003cli\u003eSignal frequency (-5 dB) = DC up to 400 kHz\u003c\/li\u003e\n\u003cli\u003eDifferential voltage = 0.5 to 1.25 V ss\u003c\/li\u003e\n\u003cli\u003eCommon-mode voltage = Max. ±7 V\u003c\/li\u003e\n\u003cli\u003eTerminating resistor = 120 Ω\u003c\/li\u003e\n\u003cli\u003eResolution = 16384 * Number of encoder lines\u003c\/li\u003e\n\u003cli\u003eAccuracy = -\u003c\/li\u003e\n\u003cli\u003eReference input\u003c\/li\u003e\n\u003cli\u003eSignal transmission = Differential signal, symmetrical\u003c\/li\u003e\n\u003cli\u003eDifferential voltage for low = ≤-0.2 V\u003c\/li\u003e\n\u003cli\u003eDifferential voltage for high = ≥+0.2 V\u003c\/li\u003e\n\u003cli\u003eSerial interface\u003c\/li\u003e\n\u003cli\u003eSignal transmission = Synchronous\u003c\/li\u003e\n\u003cli\u003eProtocol = RS485\u003c\/li\u003e\n\u003cli\u003eBaud rate = 625 kbaud\u003c\/li\u003e\n\u003cli\u003eQuantity = 1\u003c\/li\u003e\n\u003cli\u003eModule-side connection = 15-pin female DSUB\u003c\/li\u003e\n\u003cli\u003eStatus indicators = UP\/DN LEDs\u003c\/li\u003e\n\u003cli\u003eEncoder monitoring = Yes\u003c\/li\u003e\n\u003cli\u003eMax. encoder cable length = 50 m\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature\u003c\/li\u003e\n\u003cli\u003eOperation\u003c\/li\u003e\n\u003cli\u003eNominal = 5 to 40°C\u003c\/li\u003e\n\u003cli\u003eMaximum = 55°C\u003c\/li\u003e\n\u003cli\u003eStorage = -25 to 55°C\u003c\/li\u003e\n\u003cli\u003eTransport = -25 to 70°C\u003c\/li\u003e\n\u003cli\u003eRelative humidity\u003c\/li\u003e\n\u003cli\u003eOperation = 5 to 85%\u003c\/li\u003e\n\u003cli\u003eStorage = 5 to 95%\u003c\/li\u003e\n\u003cli\u003eTransport = Max. 95% at 40°C\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160965533949,"sku":"8AC120-60-1","price":700.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/8AC120-60-1.jpg?v=1785723106"},{"product_id":"8ac114-602","title":"B\u0026R 8AC114-602 | B\u0026R","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Motion control \u0026gt; ACOPOS \u0026gt; Plug-in modules\u003c\/p\u003e\n\u003cp\u003ePOWERLINK interface for installation in ACOPOS servo drives Integrated 2-port hub for easy wiring For communication and configuration of ACOPOS servo drives in complex and time-critical applications Node number configurable using switch ACOPOS plug-in module, POWERLINK V2 interface.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupport\u003c\/li\u003e\n\u003cli\u003eDynamic node allocation (DNA) = No\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = Non-compliant\u003c\/li\u003e\n\u003cli\u003eUL = cULus E225616 Power conversion equipment\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eModule type = ACOPOS plug-in module\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0xA5C1\u003c\/li\u003e\n\u003cli\u003eSlot = Slot 1\u003c\/li\u003e\n\u003cli\u003ePower consumption = Max. 3 W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInterfaces\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePOWERLINK\u003c\/li\u003e\n\u003cli\u003eWatchdog functionality\u003c\/li\u003e\n\u003cli\u003eHardware = Yes (via ACOPOS servo drive)\u003c\/li\u003e\n\u003cli\u003eSoftware = Yes (via ACOPOS servo drive)\u003c\/li\u003e\n\u003cli\u003eQuantity = 1\u003c\/li\u003e\n\u003cli\u003eModule-side connection = 2x RJ45 port\u003c\/li\u003e\n\u003cli\u003eStatus indicators = Status LED + 2x Link LED\u003c\/li\u003e\n\u003cli\u003eTransfer rate = 100 Mbit\/s\u003c\/li\u003e\n\u003cli\u003e2-port hub = Yes\u003c\/li\u003e\n\u003cli\u003ePossible station operating modes = Synchronous to the POWERLINK cycle\u003c\/li\u003e\n\u003cli\u003eElectrical isolation = Yes\u003c\/li\u003e\n\u003cli\u003eCabling topology = Star or tree with level 2 hubs\u003c\/li\u003e\n\u003cli\u003eMaximum number of hub levels = 10\u003c\/li\u003e\n\u003cli\u003eLine length = Max. 100 m between two stations (segment length)\u003c\/li\u003e\n\u003cli\u003eNetwork-capable = Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature\u003c\/li\u003e\n\u003cli\u003eOperation\u003c\/li\u003e\n\u003cli\u003eNominal = 5 to 40°C\u003c\/li\u003e\n\u003cli\u003eMaximum = 55°C\u003c\/li\u003e\n\u003cli\u003eStorage = -25 to 55°C\u003c\/li\u003e\n\u003cli\u003eTransport = -25 to 70°C\u003c\/li\u003e\n\u003cli\u003eRelative humidity\u003c\/li\u003e\n\u003cli\u003eOperation = 5 to 85%\u003c\/li\u003e\n\u003cli\u003eStorage = 5 to 95%\u003c\/li\u003e\n\u003cli\u003eTransport = Max. 95% at 40°C\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"Never Used Surplus","offer_id":70984815051005,"sku":"8AC114-602","price":1116.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/8AC114-602.jpg?v=1785722772"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/collections\/B_R_LOGO.png?v=1782955341","url":"https:\/\/shly-plc.com\/collections\/b-r.oembed?page=4","provider":"Lianyou PLC","version":"1.0","type":"link"}